Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Article in English | MEDLINE | ID: mdl-38782593

ABSTRACT

BACKGROUND AND PURPOSE: DSC-MRI can be used to generate fractional tumor burden (FTB) maps, via application of relative CBV thresholds, to spatially differentiate glioblastoma recurrence from post treatment radiation effects (PTRE). Image-localized histopathology was previously used to validate FTB maps derived from a reference DSC-MRI protocol using preload, a moderate flip angle (MFA, 60°) and post-processing leakage correction. Recently, a DSC-MRI protocol with a low flip angle (LFA, 30°) with no preload was shown to provide leakage-corrected RCBV equivalent to the reference protocol. This study aims to identify the RCBV thresholds for the LFA protocol that generate the most accurate FTB maps, concordant with those obtained from the reference MFA protocol. MATERIALS AND METHODS: Fifty-two patients with grade IV GBM who had prior surgical resection and received chemotherapy and radiotherapy were included in the study. Two sets of DSC-MRI data were collected sequentially first using LFA protocol with no preload, which served as the preload for the subsequent MFA protocol. Standardized relative CBV maps (sRCBV) were obtained for each patient and co-registered with the anatomical post-contrast T1-weighted images. The reference MFA-based FTB maps were computed using previously published sRCBV thresholds (1.0 and 1.56). An ROC analysis was conducted to identify the optimal, voxelwise LFA sRCBV thresholds, and the sensitivity, specificity, and accuracy of the LFA-based FTB maps were computed with respect to the MFA-based reference. RESULTS: The mean sRCBV values of tumors across patients exhibited strong agreement (CCC = 0.99) between the two protocols. Using the ROC analysis, the optimal lower LFA threshold that accurately distinguishes PTRE from tumor recurrence was found to be 1.0 (sensitivity: 87.77%; specificity: 90.22%), equivalent to the ground truth. To identify aggressive tumor regions, the ROC analysis identified an upper LFA threshold of 1.37 (sensitivity: 90.87%; specificity: 91.10%) for the reference MFA threshold of 1.56. CONCLUSION: For LFA-based FTB maps, a sRCBV threshold of 1.0 and 1.37 can differentiate PTRE from recurrent tumor. FTB maps aids in surgical planning, guiding pathological diagnosis and treatment strategies in the recurrent setting. This study further confirms the reliability of single-dose LFA-based DSC-MRI. ABBREVIATIONS: LFA = low flip angle; MFA = moderate flip angle; sRCBV = standardized relative cerebral blood volume; FTB = fractional tumor burden; PTRE = post treatment radiation effects; ROC = receiver operating characteristics; CCC = concordance correlation coefficient.

4.
Magn Reson Med ; 91(5): 1761-1773, 2024 May.
Article in English | MEDLINE | ID: mdl-37831600

ABSTRACT

This manuscript describes the ISMRM OSIPI (Open Science Initiative for Perfusion Imaging) lexicon for dynamic contrast-enhanced and dynamic susceptibility-contrast MRI. The lexicon was developed by Taskforce 4.2 of OSIPI to provide standardized definitions of commonly used quantities, models, and analysis processes with the aim of reducing reporting variability. The taskforce was established in February 2020 and consists of medical physicists, engineers, clinicians, data and computer scientists, and DICOM (Digital Imaging and Communications in Medicine) standard experts. Members of the taskforce collaborated via a slack channel and quarterly virtual meetings. Members participated by defining lexicon items and reporting formats that were reviewed by at least two other members of the taskforce. Version 1.0.0 of the lexicon was subject to open review from the wider perfusion imaging community between January and March 2022, and endorsed by the Perfusion Study Group of the ISMRM in the summer of 2022. The initial scope of the lexicon was set by the taskforce and defined such that it contained a basic set of quantities, processes, and models to enable users to report an end-to-end analysis pipeline including kinetic model fitting. We also provide guidance on how to easily incorporate lexicon items and definitions into free-text descriptions (e.g., in manuscripts and other documentation) and introduce an XML-based pipeline encoding format to encode analyses using lexicon definitions in standardized and extensible machine-readable code. The lexicon is designed to be open-source and extendable, enabling ongoing expansion of its content. We hope that widespread adoption of lexicon terminology and reporting formats described herein will increase reproducibility within the field.


Subject(s)
Contrast Media , Magnetic Resonance Imaging , Reproducibility of Results , Magnetic Resonance Imaging/methods , Perfusion , Perfusion Imaging
5.
Front Oncol ; 13: 1046629, 2023.
Article in English | MEDLINE | ID: mdl-36733305

ABSTRACT

Background: Relative cerebral blood volume (rCBV) obtained from dynamic susceptibility contrast (DSC) MRI is widely used to distinguish high grade glioma recurrence from post treatment radiation effects (PTRE). Application of rCBV thresholds yield maps to distinguish between regional tumor burden and PTRE, a biomarker termed the fractional tumor burden (FTB). FTB is generally measured using conventional double-dose, single-echo DSC-MRI protocols; recently, a single-dose, dual-echo DSC-MRI protocol was clinically validated by direct comparison to the conventional double-dose, single-echo protocol. As the single-dose, dual-echo acquisition enables reduction in the contrast agent dose and provides greater pulse sequence parameter flexibility, there is a compelling need to establish dual-echo DSC-MRI based FTB mapping. In this study, we determine the optimum standardized rCBV threshold for the single-dose, dual-echo protocol to generate FTB maps that best match those derived from the reference standard, double-dose, single-echo protocol. Methods: The study consisted of 23 high grade glioma patients undergoing perfusion scans to confirm suspected tumor recurrence. We sequentially acquired single dose, dual-echo and double dose, single-echo DSC-MRI data. For both protocols, we generated leakage-corrected standardized rCBV maps. Standardized rCBV (sRCBV) thresholds of 1.0 and 1.75 were used to compute single-echo FTB maps as the reference for delineating PTRE (sRCBV < 1.0), tumor with moderate angiogenesis (1.0 < sRCBV < 1.75), and tumor with high angiogenesis (sRCBV > 1.75) regions. To assess the sRCBV agreement between acquisition protocols, the concordance correlation coefficient (CCC) was computed between the mean tumor sRCBV values across the patients. A receiver operating characteristics (ROC) analysis was performed to determine the optimum dual-echo sRCBV threshold. The sensitivity, specificity, and accuracy were compared between the obtained optimized threshold (1.64) and the standard reference threshold (1.75) for the dual-echo sRCBV threshold. Results: The mean tumor sRCBV values across the patients showed a strong correlation (CCC = 0.96) between the two protocols. The ROC analysis showed maximum accuracy at thresholds of 1.0 (delineate PTRE from tumor) and 1.64 (differentiate aggressive tumors). The reference threshold (1.75) and the obtained optimized threshold (1.64) yielded similar accuracy, with slight differences in sensitivity and specificity which were not statistically significant (1.75 threshold: Sensitivity = 81.94%; Specificity: 87.23%; Accuracy: 84.58% and 1.64 threshold: Sensitivity = 84.48%; Specificity: 84.97%; Accuracy: 84.73%). Conclusions: The optimal sRCBV threshold for single-dose, dual-echo protocol was found to be 1.0 and 1.64 for distinguishing tumor recurrence from PTRE; however, minimal differences were observed when using the standard threshold (1.75) as the upper threshold, suggesting that the standard threshold could be used for both protocols. While the prior study validated the agreement of the mean sRCBV values between the protocols, this study confirmed that their voxel-wise agreement is suitable for reliable FTB mapping. Dual-echo DSC-MRI acquisitions enable robust single-dose sRCBV and FTB mapping, provide pulse sequence parameter flexibility and should improve reproducibility by mitigating variations in preload dose and incubation time.

6.
J Neurotrauma ; 39(19-20): 1429-1441, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35593008

ABSTRACT

Severe traumatic brain injury (TBI) results in cognitive dysfunction in part due to vascular perturbations. In contrast, the long-term vasculo-cognitive pathophysiology of mild TBI (mTBI) remains unknown. We evaluated mTBI effects on chronic cognitive and cerebrovascular function and assessed their interrelationships. Sprague-Dawley rats received midline fluid percussion injury (n = 20) or sham (n = 21). Cognitive function was assessed (3- and 6-month novel object recognition [NOR], novel object location [NOL], and temporal order object recognition [TOR]). Six-month cerebral blood flow (CBF) and cerebral blood volume (CBV) using contrast magnetic resonance imaging (MRI) and ex vivo circle of Willis artery endothelial and smooth muscle-dependent function were measured. mTBI rats showed significantly impaired NOR, with similar trends (non-significant) in NOL/TOR. Regional CBF and CBV were similar in sham and mTBI. NOR correlated with CBF in lateral hippocampus, medial hippocampus, and primary somatosensory barrel cortex, whereas it inversely correlated with arterial smooth muscle-dependent dilation. Six-month baseline endothelial and smooth muscle-dependent arterial function were similar among mTBI and sham, but post-angiotensin 2 stimulation, mTBI showed no change in smooth muscle-dependent dilation from baseline response, unlike the reduction in sham. mTBI led to chronic cognitive dysfunction and altered angiotensin 2-stimulated smooth muscle-dependent vasoreactivity. The findings of persistent pathophysiological consequences of mTBI in this animal model add to the broader understanding of chronic pathophysiological sequelae in human mild TBI.


Subject(s)
Brain Concussion , Cerebrovascular Circulation , Cognition , Animals , Humans , Rats , Angiotensins , Brain Concussion/complications , Brain Concussion/pathology , Rats, Sprague-Dawley
7.
Magn Reson Imaging ; 85: 217-221, 2022 01.
Article in English | MEDLINE | ID: mdl-34715291

ABSTRACT

T2⁎ relaxivity contrast imaging may serve as a potential imaging biomarker for amyotrophic lateral sclerosis (ALS) by noninvasively quantifying the tissue microstructure. In this preliminary longitudinal study, we investigated the Transverse Relaxivity at Tracer Equilibrium (TRATE) in three muscle groups between SOD1-G93A (ALS model) rat and a control population at two different timepoints. The control group was time matched to the ALS group such that the second timepoint was the onset of disease. We observed a statistically significant decrease in TRATE over time in the gastrocnemius, tibialis, and digital flexor muscles in the SOD1-G93A model (p-value = 0.003, 0.008, 0.005; respectively), whereas TRATE did not change over time in the control group (p-value = 0.4777, 0.6837, 0.9682; respectively). Immunofluorescent staining revealed a decrease in minimum fiber area and cell density in the SOD1-G93A model when compared to the control group (p-value = 6.043E-10 and 2.265E-10, respectively). These microstructural changes observed from histology align with the theorized biophysical properties of TRATE. We demonstrate that TRATE can longitudinally differentiate disease associated atrophy from healthy muscle and has potential to serve as a biomarker for disease progression and ultimately therapy response in patients with ALS.


Subject(s)
Amyotrophic Lateral Sclerosis , Amyotrophic Lateral Sclerosis/complications , Amyotrophic Lateral Sclerosis/diagnostic imaging , Amyotrophic Lateral Sclerosis/pathology , Animals , Disease Models, Animal , Disease Progression , Humans , Longitudinal Studies , Mice , Mice, Transgenic , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/pathology , Rats
8.
J Magn Reson Imaging ; 55(6): 1745-1758, 2022 06.
Article in English | MEDLINE | ID: mdl-34767682

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI) is commonly used to detect prostate cancer, and a major clinical challenge is differentiating aggressive from indolent disease. PURPOSE: To compare 14 site-specific parametric fitting implementations applied to the same dataset of whole-mount pathologically validated DWI to test the hypothesis that cancer differentiation varies with different fitting algorithms. STUDY TYPE: Prospective. POPULATION: Thirty-three patients prospectively imaged prior to prostatectomy. FIELD STRENGTH/SEQUENCE: 3 T, field-of-view optimized and constrained undistorted single-shot DWI sequence. ASSESSMENT: Datasets, including a noise-free digital reference object (DRO), were distributed to the 14 teams, where locally implemented DWI parameter maps were calculated, including mono-exponential apparent diffusion coefficient (MEADC), kurtosis (K), diffusion kurtosis (DK), bi-exponential diffusion (BID), pseudo-diffusion (BID*), and perfusion fraction (F). The resulting parametric maps were centrally analyzed, where differentiation of benign from cancerous tissue was compared between DWI parameters and the fitting algorithms with a receiver operating characteristic area under the curve (ROC AUC). STATISTICAL TEST: Levene's test, P < 0.05 corrected for multiple comparisons was considered statistically significant. RESULTS: The DRO results indicated minimal discordance between sites. Comparison across sites indicated that K, DK, and MEADC had significantly higher prostate cancer detection capability (AUC range = 0.72-0.76, 0.76-0.81, and 0.76-0.80 respectively) as compared to bi-exponential parameters (BID, BID*, F) which had lower AUC and greater between site variation (AUC range = 0.53-0.80, 0.51-0.81, and 0.52-0.80 respectively). Post-processing parameters also affected the resulting AUC, moving from, for example, 0.75 to 0.87 for MEADC varying cluster size. DATA CONCLUSION: We found that conventional diffusion models had consistent performance at differentiating prostate cancer from benign tissue. Our results also indicated that post-processing decisions on DWI data can affect sensitivity and specificity when applied to radiological-pathological studies in prostate cancer. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.


Subject(s)
Diffusion Magnetic Resonance Imaging , Prostatic Neoplasms , Diffusion Magnetic Resonance Imaging/methods , Humans , Male , Prospective Studies , Prostatic Neoplasms/diagnostic imaging , ROC Curve , Retrospective Studies , Sensitivity and Specificity
9.
J Cereb Blood Flow Metab ; 41(12): 3378-3390, 2021 12.
Article in English | MEDLINE | ID: mdl-34415211

ABSTRACT

Relative cerebral blood volume (rCBV) obtained from dynamic susceptibility contrast (DSC) MRI is adversely impacted by contrast agent leakage in brain tumors. Using simulations, we previously demonstrated that multi-echo DSC-MRI protocols provide improvements in contrast agent dosing, pulse sequence flexibility, and rCBV accuracy. The purpose of this study is to assess the in-vivo performance of dual-echo acquisitions in patients with brain tumors (n = 59). To verify pulse sequence flexibility, four single-dose dual-echo acquisitions were tested with variations in contrast agent dose, flip angle, and repetition time, and the resulting dual-echo rCBV was compared to standard single-echo rCBV obtained with preload (double-dose). Dual-echo rCBV was comparable to standard double-dose single-echo protocols (mean (standard deviation) tumor rCBV 2.17 (1.28) vs. 2.06 (1.20), respectively). High rCBV similarity was observed (CCC = 0.96), which was maintained across both flip angle (CCC = 0.98) and repetition time (CCC = 0.96) permutations, demonstrating that dual-echo acquisitions provide flexibility in acquisition parameters. Furthermore, a single dual-echo acquisition was shown to enable quantification of both perfusion and permeability metrics. In conclusion, single-dose dual-echo acquisitions provide similar rCBV to standard double-dose single-echo acquisitions, suggesting contrast agent dose can be reduced while providing significant pulse sequence flexibility and complementary tumor perfusion and permeability metrics.


Subject(s)
Brain Neoplasms , Cerebral Blood Volume , Cerebrovascular Circulation , Contrast Media/administration & dosage , Magnetic Resonance Imaging , Adult , Aged , Aged, 80 and over , Brain Neoplasms/blood supply , Brain Neoplasms/diagnostic imaging , Female , Humans , Male , Middle Aged , Retrospective Studies
10.
Magn Reson Med ; 86(6): 3082-3095, 2021 12.
Article in English | MEDLINE | ID: mdl-34288112

ABSTRACT

PURPOSE: The purpose of this study was to develop a spiral-based combined spin- and gradient-echo (spiral-SAGE) method for simultaneous dynamic contrast-enhanced (DCE-MRI) and dynamic susceptibility contrast MRI (DSC-MRI). METHODS: Using this sequence, we obtained gradient-echo TEs of 1.69 and 26 ms, a SE TE of 87.72 ms, with a TR of 1663 ms. Using an iterative SENSE reconstruction followed by deblurring, spiral-induced image artifacts were minimized. Healthy volunteer images are shown to demonstrate image quality using the optimized reconstruction, as well as for comparison with EPI-based SAGE. A bioreactor phantom was used to compare dynamic-contrast time courses with both spiral-SAGE and EPI-SAGE. A proof-of-concept cohort of patients with brain tumors shows the range of hemodynamic maps available using spiral-SAGE. RESULTS: Comparison of spiral-SAGE images with conventional EPI-SAGE images illustrates substantial reductions of image distortion and artifactual image intensity variations. Bioreactor phantom data show similar dynamic contrast time courses between standard EPI-SAGE and spiral-SAGE for the second and third echoes, whereas first-echo data show improvements in quantifying T1 changes with shorter echo times. In a cohort of patients with brain tumors, spiral-SAGE-based perfusion and permeability maps are shown with comparison with the standard single-echo EPI perfusion map. CONCLUSION: Spiral-SAGE provides a substantial improvement for the assessment of perfusion and permeability by mitigating artifacts typically encountered with EPI and by providing a shorter echo time for improved characterization of permeability. Spiral-SAGE enables quantification of perfusion, permeability, and vessel architectural parameters, as demonstrated in brain tumors.


Subject(s)
Brain Neoplasms , Contrast Media , Brain/diagnostic imaging , Brain Neoplasms/diagnostic imaging , Echo-Planar Imaging , Humans , Magnetic Resonance Imaging , Neuroimaging
11.
Tomography ; 7(2): 169-179, 2021 05 05.
Article in English | MEDLINE | ID: mdl-34062974

ABSTRACT

(1) Background: This work characterizes the sensitivity of magnetic resonance-based Relaxivity Contrast Imaging (RCI) to Amyotrophic Lateral Sclerosis (ALS)-induced changes in myofiber microstructure. Transverse Relaxivity at Tracer Equilibrium (TRATE), an RCI-based parameter, was evaluated in the lower extremities of ALS patients and healthy subjects. (2) Methods: In this IRB-approved study, 23 subjects (12 ALS patients and 11 healthy controls) were scanned at 3T (Philips, The Netherlands). RCI data were obtained during injection of a gadolinium-based contrast agent. TRATE, fat fraction and T2 measures, were compared in five muscle groups of the calf muscle, between ALS and control populations. TRATE was also evaluated longitudinally (baseline and 6 months) and was compared to clinical measures, namely ALS Functional Rating Scale (ALSFRS-R) and Hand-Held Dynamometry (HHD), in a subset of the ALS population. (3) Results: TRATE was significantly lower (p < 0.001) in ALS-affected muscle than in healthy muscle in all muscle groups. Fat fraction differences between ALS and healthy muscle were statistically significant for the tibialis anterior (p = 0.01), tibialis posterior (p = 0.004), and peroneus longus (p = 0.02) muscle groups but were not statistically significant for the medial (p = 0.07) and lateral gastrocnemius (p = 0.06) muscles. T2 differences between ALS and healthy muscle were statistically significant for the tibialis anterior (p = 0.004), peroneus longus (p = 0.004) and lateral gastrocnemius (p = 0.03) muscle groups but were not statistically significant for the tibialis posterior (p = 0.06) and medial gastrocnemius (p = 0.07) muscles. Longitudinally, TRATE, averaged over all patients, decreased by 28 ± 16% in the tibialis anterior, 47 ± 18% in the peroneus longus, 25 ± 19% in the tibialis posterior, 29 ± 14% in the medial gastrocnemius and 35 ± 18% in the lateral gastrocnemius muscles between two timepoints. ALSFRS-R scores were stable in two of four ALS patients. HHD scores decreased in three of four ALS patients. (4) Conclusion: RCI-based TRATE was shown to consistently differentiate ALS-affected muscle from healthy muscle and also provide a quantitative measure of longitudinal muscle degeneration.


Subject(s)
Amyotrophic Lateral Sclerosis , Amyotrophic Lateral Sclerosis/diagnostic imaging , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Muscle, Skeletal/diagnostic imaging , Netherlands
12.
Tomography ; 6(2): 203-208, 2020 06.
Article in English | MEDLINE | ID: mdl-32548297

ABSTRACT

We have previously characterized the reproducibility of brain tumor relative cerebral blood volume (rCBV) using a dynamic susceptibility contrast magnetic resonance imaging digital reference object across 12 sites using a range of imaging protocols and software platforms. As expected, reproducibility was highest when imaging protocols and software were consistent, but decreased when they were variable. Our goal in this study was to determine the impact of rCBV reproducibility for tumor grade and treatment response classification. We found that varying imaging protocols and software platforms produced a range of optimal thresholds for both tumor grading and treatment response, but the performance of these thresholds was similar. These findings further underscore the importance of standardizing acquisition and analysis protocols across sites and software benchmarking.


Subject(s)
Brain Neoplasms , Cerebral Blood Volume , Brain Neoplasms/blood supply , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/pathology , Contrast Media , Humans , Magnetic Resonance Imaging , Neoplasm Grading , Reference Values , Reproducibility of Results , Retrospective Studies
13.
J Magn Reson Imaging ; 51(2): 547-553, 2020 02.
Article in English | MEDLINE | ID: mdl-31206948

ABSTRACT

BACKGROUND: Dynamic susceptibility contrast (DSC)-MRI analysis pipelines differ across studies and sites, potentially confounding the clinical value and use of the derived biomarkers. PURPOSE/HYPOTHESIS: To investigate how postprocessing steps for computation of cerebral blood volume (CBV) and residue function dependent parameters (cerebral blood flow [CBF], mean transit time [MTT], capillary transit heterogeneity [CTH]) impact glioma grading. STUDY TYPE: Retrospective study from The Cancer Imaging Archive (TCIA). POPULATION: Forty-nine subjects with low- and high-grade gliomas. FIELD STRENGTH/SEQUENCE: 1.5 and 3.0T clinical systems using a single-echo echo planar imaging (EPI) acquisition. ASSESSMENT: Manual regions of interest (ROIs) were provided by TCIA and automatically segmented ROIs were generated by k-means clustering. CBV was calculated based on conventional equations. Residue function dependent biomarkers (CBF, MTT, CTH) were found by two deconvolution methods: circular discretization followed by a signal-to-noise ratio (SNR)-adapted eigenvalue thresholding (Method 1) and Volterra discretization with L-curve-based Tikhonov regularization (Method 2). STATISTICAL TESTS: Analysis of variance, receiver operating characteristics (ROC), and logistic regression tests. RESULTS: MTT alone was unable to statistically differentiate glioma grade (P > 0.139). When normalized, tumor CBF, CTH, and CBV did not differ across field strengths (P > 0.141). Biomarkers normalized to automatically segmented regions performed equally (rCTH AUROC is 0.73 compared with 0.74) or better (rCBF AUROC increases from 0.74-0.84; rCBV AUROC increases 0.78-0.86) than manually drawn ROIs. By updating the current deconvolution steps (Method 2), rCTH can act as a classifier for glioma grade (P < 0.007), but not if processed by current conventional DSC methods (Method 1) (P > 0.577). Lastly, higher-order biomarkers (eg, rCBF and rCTH) along with rCBV increases AUROC to 0.92 for differentiating tumor grade as compared with 0.78 and 0.86 (manual and automatic reference regions, respectively) for rCBV alone. DATA CONCLUSION: With optimized analysis pipelines, higher-order perfusion biomarkers (rCBF and rCTH) improve glioma grading as compared with CBV alone. Additionally, postprocessing steps impact thresholds needed for glioma grading. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:547-553.


Subject(s)
Brain Neoplasms , Glioma , Biomarkers , Brain Neoplasms/diagnostic imaging , Cerebrovascular Circulation , Contrast Media , Glioma/diagnostic imaging , Humans , Magnetic Resonance Imaging , Neoplasm Grading , Retrospective Studies
14.
Magn Reson Med ; 83(1): 109-123, 2020 01.
Article in English | MEDLINE | ID: mdl-31400035

ABSTRACT

PURPOSE: Brain tumor dynamic susceptibility contrast (DSC) MRI is adversely impacted by T1 and T2∗ contrast agent leakage effects that result in inaccurate hemodynamic metrics. While multi-echo acquisitions remove T1 leakage effects, there is no consensus on the optimal set of acquisition parameters. Using a computational approach, we systematically evaluated a wide range of acquisition strategies to determine the optimal multi-echo DSC-MRI perfusion protocol. METHODS: Using a population-based DSC-MRI digital reference object (DRO), we assessed the influence of preload dosing (no preload and full dose preload), field strength (1.5 and 3T), pulse sequence parameters (echo time, repetition time, and flip angle), and leakage correction on relative cerebral blood volume (rCBV) and flow (rCBF) accuracy. We also compared multi-echo DSC-MRI protocols with standard single-echo protocols. RESULTS: Multi-echo DSC-MRI is highly consistent across all protocols, and multi-echo rCBV (with or without use of a preload dose) had higher accuracy than single-echo rCBV. Regression analysis showed that choice of repetition time and flip angle had minimal impact on multi-echo rCBV and rCBV, indicating the potential for significant flexibility in acquisition parameters. The echo time combination had minimal impact on rCBV, though longer echo times should be avoided, particularly at higher field strengths. Leakage correction improved rCBV accuracy in all cases. Multi-echo rCBF was less biased than single-echo rCBF, although rCBF accuracy was reduced overall relative to rCBV. CONCLUSIONS: Multi-echo acquisitions were more robust than single-echo, essentially decoupling both repetition time and flip angle from rCBV accuracy. Multi-echo acquisitions obviate the need for preload dosing, although leakage correction to remove residual T2∗ leakage effects remains compulsory for high rCBV accuracy.


Subject(s)
Brain Neoplasms/diagnostic imaging , Cerebral Blood Volume , Contrast Media/chemistry , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Neuroimaging , White Matter/diagnostic imaging , Algorithms , Cerebrovascular Circulation , Glioblastoma/diagnostic imaging , Humans , Image Interpretation, Computer-Assisted/methods , Perfusion , Reference Values , Reproducibility of Results , Software
15.
Tomography ; 5(1): 110-117, 2019 03.
Article in English | MEDLINE | ID: mdl-30854448

ABSTRACT

Relative cerebral blood volume (rCBV) cannot be used as a response metric in clinical trials, in part, because of variations in biomarker consistency and associated interpretation across sites, stemming from differences in image acquisition and postprocessing methods (PMs). This study leveraged a dynamic susceptibility contrast magnetic resonance imaging digital reference object to characterize rCBV consistency across 12 sites participating in the Quantitative Imaging Network (QIN), specifically focusing on differences in site-specific imaging protocols (IPs; n = 17), and PMs (n = 19) and differences due to site-specific IPs and PMs (n = 25). Thus, high agreement across sites occurs when 1 managing center processes rCBV despite slight variations in the IP. This result is most likely supported by current initiatives to standardize IPs. However, marked intersite disagreement was observed when site-specific software was applied for rCBV measurements. This study's results have important implications for comparing rCBV values across sites and trials, where variability in PMs could confound the comparison of therapeutic effectiveness and/or any attempts to establish thresholds for categorical response to therapy. To overcome these challenges and ensure the successful use of rCBV as a clinical trial biomarker, we recommend the establishment of qualifying and validating site- and trial-specific criteria for scanners and acquisition methods (eg, using a validated phantom) and the software tools used for dynamic susceptibility contrast magnetic resonance imaging analysis (eg, using a digital reference object where the ground truth is known).


Subject(s)
Brain Neoplasms/diagnostic imaging , Cerebral Blood Volume , Glioma/diagnostic imaging , Magnetic Resonance Imaging/standards , Brain Neoplasms/physiopathology , Clinical Protocols , Contrast Media , Glioma/physiopathology , Humans , Image Interpretation, Computer-Assisted/standards , Magnetic Resonance Imaging/methods , Reference Standards , Reproducibility of Results , Software/standards
16.
Neuroimage ; 187: 32-55, 2019 02 15.
Article in English | MEDLINE | ID: mdl-29729392

ABSTRACT

In the context of neurologic disorders, dynamic susceptibility contrast (DSC) and dynamic contrast enhanced (DCE) MRI provide valuable insights into cerebral vascular function, integrity, and architecture. Even after two decades of use, these modalities continue to evolve as their biophysical and kinetic basis is better understood, with improvements in pulse sequences and accelerated imaging techniques and through application of more robust and automated data analysis strategies. Here, we systematically review each of these elements, with a focus on how their integration improves kinetic parameter accuracy and the development of new hemodynamic biomarkers that provide sub-voxel sensitivity (e.g., capillary transit time and flow heterogeneity). Regarding contrast mechanisms, we discuss the dipole-dipole interactions and susceptibility effects that give rise to simultaneous T1, T2 and T2∗ relaxation effects, including their quantification, influence on pulse sequence parameter optimization, and use in methods such as vessel size and vessel architectural imaging. The application of technologic advancements, such as parallel imaging, simultaneous multi-slice, undersampled k-space acquisitions, and sliding window strategies, enables improved spatial and/or temporal resolution of DSC and DCE acquisitions. Such acceleration techniques have also enabled the implementation of, clinically feasible, simultaneous multi-echo spin- and gradient echo acquisitions, providing more comprehensive and quantitative interrogation of T1, T2 and T2∗ changes. Characterizing these relaxation rate changes through different post-processing options allows for the quantification of hemodynamics and vascular permeability. The application of different biophysical models provides insight into traditional hemodynamic parameters (e.g., cerebral blood volume) and more advanced parameters (e.g., capillary transit time heterogeneity). We provide insight into the appropriate selection of biophysical models and the necessary post-processing steps to ensure reliable measurements while minimizing potential sources of error. We show representative examples of advanced DSC- and DCE-MRI methods applied to pathologic conditions affecting the cerebral microcirculation, including brain tumors, stroke, aging, and multiple sclerosis. The maturation and standardization of conventional DSC- and DCE-MRI techniques has enabled their increased integration into clinical practice and use in clinical trials, which has, in turn, spurred renewed interest in their technological and biophysical development, paving the way towards a more comprehensive assessment of cerebral hemodynamics.


Subject(s)
Brain Diseases/diagnostic imaging , Brain/blood supply , Brain/diagnostic imaging , Hemodynamics , Magnetic Resonance Imaging/methods , Capillary Permeability , Contrast Media , Humans , Image Enhancement
17.
J Magn Reson Imaging ; 47(5): 1287-1297, 2018 05.
Article in English | MEDLINE | ID: mdl-29086454

ABSTRACT

BACKGROUND: A previous study demonstrated the feasibility of using 3D radial ultrashort echo time (UTE) oxygen-enhanced MRI (UTE OE-MRI) for functional imaging of healthy human lungs. The repeatability of quantitative measures from UTE OE-MRI needs to be established prior to its application in clinical research. PURPOSE: To evaluate repeatability of obstructive patterns in asthma and cystic fibrosis (CF) with UTE OE-MRI with isotropic spatial resolution and full chest coverage. STUDY TYPE: Volunteer and patient repeatability. POPULATION: Eighteen human subjects (five asthma, six CF, and seven normal subjects). FIELD STRENGTH/SEQUENCE: Respiratory-gated free-breathing 3D radial UTE (80 µs) sequence at 1.5T. ASSESSMENT: Two 3D radial UTE volumes were acquired sequentially under normoxic and hyperoxic conditions. A subset of subjects underwent repeat acquisitions on either the same day or ≤15 days apart. Asthma and CF subjects also underwent spirometry. A workflow including deformable registration and retrospective lung density correction was used to compute 3D isotropic percent signal enhancement (PSE) maps. Median PSE (MPSE) and ventilation defect percent (VDP) of the lung were measured from the PSE map. STATISTICAL TESTS: The relations between MPSE, VDP, and spirometric measures were assessed using Spearman correlations. The test-retest repeatability was evaluated using Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: Ventilation measures in normal subjects (MPSE = 8.0%, VDP = 3.3%) were significantly different from those in asthma (MPSE = 6.0%, P = 0.042; VDP = 21.7%, P = 0.018) and CF group (MPSE = 4.5%, P = 0.0006; VDP = 27.2%, P = 0.002). MPSE correlated significantly with forced expiratory lung volume in 1 second percent predicted (ρ = 0.72, P = 0.017). The ICC of the test-retest VDP and MPSE were both ≥0.90. In all subject groups, an anterior/posterior gradient was observed with higher MPSE and lower VDP in the posterior compared to anterior regions (P ≤ 0.0021 for all comparisons). DATA CONCLUSION: 3D radial UTE OE-MRI supports quantitative differentiation of diseased vs. healthy lungs using either whole lung VDP or MPSE with excellent test-retest repeatability. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1287-1297.


Subject(s)
Asthma/diagnostic imaging , Cystic Fibrosis/diagnostic imaging , Imaging, Three-Dimensional , Lung/diagnostic imaging , Magnetic Resonance Imaging , Oxygen/chemistry , Pulmonary Ventilation , Adult , Deep Learning , Female , Humans , Hyperoxia/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Male , Middle Aged , Reproducibility of Results , Respiration , Respiratory Function Tests , Spirometry , Workflow , Young Adult
18.
Tomography ; 3(2): 89-95, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28825039

ABSTRACT

With DSC-MRI, contrast agent leakage effects in brain tumors can either be leveraged for percent signal recovery (PSR) measurements or be adequately resolved for accurate relative cerebral blood volume (rCBV) measurements. Leakage effects can be dimished by administration of a preload dose before imaging and/or specific postprocessing steps. This study compares the consistency of both PSR and rCBV measurements as a function of varying preload doses in a retrospective analysis of 14 subjects with high-grade gliomas. The scans consisted of 6 DSC-MRI scans during 6 sequential bolus injections (0.05 mmol/kg). Mean PSR was calculated for tumor and normal-appearing white matter regions of interest. DSC-MRI data were corrected for leakage effects before computing mean tumor rCBV. Statistical differences were seen across varying preloads for tumor PSR (P value = 4.57E-24). Tumor rCBV values did not exhibit statistically significant differences across preloads (P value = .14) and were found to be highly consistent for clinically relevant preloads (intraclass correlation coefficient = 0.93). For a 0.05 mmol/kg injection bolus and pulse sequence parameters used, the highest PSR contrast between normal-appearing white matter and tumor occurs when no preload is used. This suggests that studies using PSR as a biomarker should acquire DSC-MRI data without preload. The finding that leakage-corrected rCBV values do not depend on the presence or dose of preload contradicts that of previous studies with dissimilar acquisition protocols. This further confirms the sensitivity of rCBV to preload dosing schemes and pulse sequence parameters and highlights the importance of standardization efforts for achieving multisite rCBV consistency.

19.
Tomography ; 3(1): 41-49, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28584878

ABSTRACT

The standardization and broad-scale integration of dynamic susceptibility contrast (DSC)-magnetic resonance imaging (MRI) have been confounded by a lack of consensus on DSC-MRI methodology for preventing potential relative cerebral blood volume inaccuracies, including the choice of acquisition protocols and postprocessing algorithms. Therefore, we developed a digital reference object (DRO), using physiological and kinetic parameters derived from in vivo data, unique voxel-wise 3-dimensional tissue structures, and a validated MRI signal computational approach, aimed at validating image acquisition and analysis methods for accurately measuring relative cerebral blood volume in glioblastomas. To achieve DSC-MRI signals representative of the temporal characteristics, magnitude, and distribution of contrast agent-induced T1 and changes observed across multiple glioblastomas, the DRO's input parameters were trained using DSC-MRI data from 23 glioblastomas (>40 000 voxels). The DRO's ability to produce reliable signals for combinations of pulse sequence parameters and contrast agent dosing schemes unlike those in the training data set was validated by comparison with in vivo dual-echo DSC-MRI data acquired in a separate cohort of patients with glioblastomas. Representative applications of the DRO are presented, including the selection of DSC-MRI acquisition and postprocessing methods that optimize CBV accuracy, determination of the impact of DSC-MRI methodology choices on sample size requirements, and the assessment of treatment response in clinical glioblastoma trials.

20.
Radiology ; 278(2): 413-21, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26422185

ABSTRACT

PURPOSE: To demonstrate the feasibility of free-breathing three-dimensional (3D) radial ultrashort echo time (UTE) magnetic resonance (MR) imaging in the simultaneous detection of pulmonary embolism (PE) and high-quality evaluation of lung parenchyma. MATERIALS AND METHODS: The institutional animal care committee approved this study. A total of 12 beagles underwent MR imaging and computed tomography (CT) before and after induction of PE with autologous clots. Breath-hold 3D MR angiography and free-breathing 3D radial UTE (1.0-mm isotropic spatial resolution; echo time, 0.08 msec) were performed at 3 T. Two blinded radiologists independently marked and graded all PEs on a four-point scale (1 = low confidence, 4 = absolutely certain) on MR angiographic and UTE images. Image quality of pulmonary arteries and lung parenchyma was scored on a four-point-scale (1 = poor, 4 = excellent). Locations and ratings of emboli were compared with reference standard CT images by using an alternative free-response receiver operating characteristic curve (AFROC) method. Areas under the curve and image quality ratings were compared by using the F test and the Wilcoxon signed-rank test. RESULTS: A total of 48 emboli were detected with CT. Both readers showed higher sensitivity for PE detection with UTE (83% and 79%) than with MR angiography (75% and 71%). The AFROC area under the curve was higher for UTE than for MR angiography (0.95 vs 0.89), with a significant difference in area under the curve of 0.06 (95% confidence interval: 0.01, 0.11; P = .018). UTE image quality exceeded that of MR angiography for subsegmental arteries (3.5 ± 0.7 vs 2.9 ± 0.5, P = .002) and lung parenchyma (3.8 ± 0.5 vs 2.2 ± 0.2, P < .001). The apparent signal-to-noise ratio in pulmonary arteries and lung parenchyma was significantly higher for UTE than for MR angiography (41.0 ± 5.2 vs 24.5 ± 6.2 [P < .001] and 10.2 ± 1.8 vs 3.5 ± 0.8 [P < .001], respectively). The apparent contrast-to-noise ratio between arteries and PEs was higher for UTE than for MR angiography (20.3 ± 5.2 vs 15.4 ± 6.7, P = .055). CONCLUSION: In a canine model, free-breathing 3D radial UTE performs better than breath-hold 3D MR angiography in the detection of PE and yields better image quality for visualization of small vessels and lung parenchyma. Free-breathing 3D radial UTE for detection of PE is feasible and warrants evaluation in human subjects.


Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Angiography/methods , Pulmonary Embolism/diagnosis , Animals , Contrast Media , Disease Models, Animal , Dogs , Gadolinium , Organometallic Compounds , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...