Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Protein Expr Purif ; 205: 106228, 2023 05.
Article in English | MEDLINE | ID: mdl-36587709

ABSTRACT

In recent years, many biological-based products have been developed, representing a significant fraction of income in the pharmaceutical market. Ion exchange chromatography is an important downstream step for the purification of target recombinant proteins present in clarified cell extracts, together with many other unknown impurities. This work develops a robust approach to model and simulate the purification of untagged heterologous proteins, so that the improved conditions to carry out an ion exchange chromatography are identified in a rational basis prior to the real purification run itself. Purification of the pneumococcal surface protein A (PspA4Pro) was used as a case study. This protein is produced by recombinant Escherichia coli and is a candidate for the manufacture of improved pneumococcal vaccines. The developed method combined experimental and computational procedures. Different anion exchange operating conditions were mapped in order to gather a broad range of representative experimental data. The equilibrium dispersive and the steric mass action equations were used to model and simulate the process. A training strategy to fit the model and separately describe the elution profiles of PspA4Pro and other proteins of the cell extract was applied. Based on the simulation results, a reduced ionic strength was applied for PspA4Pro elution, leading to increases of 14.9% and 11.5% for PspA4Pro recovery and purity, respectively, compared to the original elution profile. These results showed the potential of this method, which could be further applied to improve the performance of ion exchange chromatography in the purification of other target proteins under real process conditions.


Subject(s)
Biological Products , Complex Mixtures , Chromatography, Ion Exchange/methods , Recombinant Proteins/chemistry , Complex Mixtures/metabolism , Biological Products/metabolism , Escherichia coli/genetics , Escherichia coli/metabolism
2.
Protein Expr Purif, v. 205, 106228, dez. 2022
Article in English | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: bud-4752

ABSTRACT

In recent years, many biological-based products have been developed, representing a significant fraction of income in the pharmaceutical market. Ion exchange chromatography is an important downstream step for the purification of target recombinant proteins present in clarified cell extracts, together with many other unknown impurities. This work develops a robust approach to model and simulate the purification of untagged heterologous proteins, so that the improved conditions to carry out an ion exchange chromatography are identified in a rational basis prior to the real purification run itself. Purification of the pneumococcal surface protein A (PspA4Pro) was used as a case study. This protein is produced by recombinant Escherichia coli and is a candidate for the manufacture of improved pneumococcal vaccines. The developed method combined experimental and computational procedures. Different anion exchange operating conditions were mapped in order to gather a broad range of representative experimental data. The equilibrium dispersive and the steric mass action equations were used to model and simulate the process. A training strategy to fit the model and separately describe the elution profiles of PspA4Pro and other proteins of the cell extract was applied. Based on the simulation results, a reduced ionic strength was applied for PspA4Pro elution, leading to increases of 14.9% and 11.5% for PspA4Pro recovery and purity, respectively, compared to the original elution profile. These results showed the potential of this method, which could be further applied to improve the performance of ion exchange chromatography in the purification of other target proteins under real process conditions.

3.
J Chromatogr A ; 1613: 460685, 2020 Feb 22.
Article in English | MEDLINE | ID: mdl-31733895

ABSTRACT

Ion exchange chromatography is extensively used in the purification of biological compounds. Reliable mathematical models describing this chromatographic technique are available and can be used to improve the performance of this separation step. However, the use of synthetic mixtures for model development hampers the application of this approach with real cell extracts processed in downstream operations. This work presents an original approach for handling non-synthetic genuine mixtures of proteins, which was applied in the purification of an untagged recombinant pneumococcal surface protein A (PspA4Pro). First, evaluation was made of the efficiency of steric mass action (SMA) and modified Langmuir isotherms, which were separately used together with the equilibrium dispersive model (EDM). The data used for parameter estimation and model validation were obtained from anion exchange chromatography runs (employing Q-Sepharose FF), applied to real cell extracts produced by different cultivation strategies. Simulations showed that the models were able to describe the complex mixtures of unknown proteins. Next, the EDM and SMA approaches were used to separately describe the profile of PspA4Pro and the pool of protein impurities eluted together. The simulations showed that PspA4Pro tended to elute at the beginning of the peak, enabling the establishment of an alternative elution schedule that provided a 34% increase in the purity achieved using the anion exchange chromatography.


Subject(s)
Bacterial Proteins/isolation & purification , Chemistry Techniques, Analytical/methods , Chromatography, Ion Exchange , Complex Mixtures/chemistry , Computer Simulation , Models, Chemical , Anions , Sepharose/chemistry
4.
J. Chromatogr. A ; 1613: 460685, 2020.
Article in English | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: but-ib17550

ABSTRACT

Ion exchange chromatography is extensively used in the purification of biological compounds. Reliable mathematical models describing this chromatographic technique are available and can be used to improve the performance of this separation step. However, the use of synthetic mixtures for model development hampers the application of this approach with real cell extracts processed in downstream operations. This work presents an original approach for handling non-synthetic genuine mixtures of proteins, which was applied in the purification of an untagged recombinant pneumococcal surface protein A (PspA4Pro). First, evaluation was made of the efficiency of steric mass action (SMA) and modified Langmuir isotherms, which were separately used together with the equilibrium dispersive model (EDM). The data used for parameter estimation and model validation were obtained from anion exchange chromatography runs (employing Q-Sepharose FF), applied to real cell extracts produced by different cultivation strategies. Simulations showed that the models were able to describe the complex mixtures of unknown proteins. Next, the EDM and SMA approaches were used to separately describe the profile of PspA4Pro and the pool of protein impurities eluted together. The simulations showed that PspA4Pro tended to elute at the beginning of the peak, enabling the establishment of an alternative elution schedule that provided a 34% increase in the purity achieved using the anion exchange chromatography.

5.
J Chromatogr A, v. 1613, 460685, fev. 2020
Article in English | Sec. Est. Saúde SP, SESSP-IBPROD, Sec. Est. Saúde SP | ID: bud-2980

ABSTRACT

Ion exchange chromatography is extensively used in the purification of biological compounds. Reliable mathematical models describing this chromatographic technique are available and can be used to improve the performance of this separation step. However, the use of synthetic mixtures for model development hampers the application of this approach with real cell extracts processed in downstream operations. This work presents an original approach for handling non-synthetic genuine mixtures of proteins, which was applied in the purification of an untagged recombinant pneumococcal surface protein A (PspA4Pro). First, evaluation was made of the efficiency of steric mass action (SMA) and modified Langmuir isotherms, which were separately used together with the equilibrium dispersive model (EDM). The data used for parameter estimation and model validation were obtained from anion exchange chromatography runs (employing Q-Sepharose FF), applied to real cell extracts produced by different cultivation strategies. Simulations showed that the models were able to describe the complex mixtures of unknown proteins. Next, the EDM and SMA approaches were used to separately describe the profile of PspA4Pro and the pool of protein impurities eluted together. The simulations showed that PspA4Pro tended to elute at the beginning of the peak, enabling the establishment of an alternative elution schedule that provided a 34% increase in the purity achieved using the anion exchange chromatography.

SELECTION OF CITATIONS
SEARCH DETAIL
...