Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
1.
J Am Coll Cardiol ; 84(4): 354-364, 2024 Jul 23.
Article in English | MEDLINE | ID: mdl-39019530

ABSTRACT

BACKGROUND: ARTESiA (Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation) demonstrated that apixaban, compared with aspirin, significantly reduced stroke and systemic embolism (SE) but increased major bleeding in patients with subclinical atrial fibrillation. OBJECTIVES: To help inform decision making, the authors evaluated the efficacy and safety of apixaban according to baseline CHA2DS2-VASc score. METHODS: We performed a subgroup analysis according to baseline CHA2DS2-VASc score and assessed both the relative and absolute differences in stroke/SE and major bleeding. RESULTS: Baseline CHA2DS2-VASc scores were <4 in 1,578 (39.4%) patients, 4 in 1,349 (33.6%), and >4 in 1,085 (27.0%). For patients with CHA2DS2-VASc >4, the rate of stroke was 0.98%/year with apixaban and 2.25%/year with aspirin; compared with aspirin, apixaban prevented 1.28 (95% CI: 0.43-2.12) strokes/SE per 100 patient-years and caused 0.68 (95% CI: -0.23 to 1.57) major bleeds. For CHA2DS2-VASc <4, the stroke/SE rate was 0.85%/year with apixaban and 0.97%/year with aspirin. Apixaban prevented 0.12 (95% CI: -0.38 to 0.62) strokes/SE per 100 patient-years and caused 0.33 (95% CI: -0.27 to 0.92) major bleeds. For patients with CHA2DS2-VASc =4, apixaban prevented 0.32 (95% CI: -0.16 to 0.79) strokes/SE per 100 patient-years and caused 0.28 (95% CI: -0.30 to 0.86) major bleeds. CONCLUSIONS: One in 4 patients in ARTESiA with subclinical atrial fibrillation had a CHA2DS2-VASc score >4 and a stroke/SE risk of 2.2% per year. For these patients, the benefits of treatment with apixaban in preventing stroke/SE are greater than the risks. The opposite is true for patients with CHA2DS2-VASc score <4. A substantial intermediate group (CHA2DS2-VASc =4) exists in which patient preferences will inform treatment decisions. (Apixaban for the Reduction of Thrombo-Embolism in Patients With Device-Detected Sub-Clinical Atrial Fibrillation; NCT01938248).


Subject(s)
Aspirin , Atrial Fibrillation , Factor Xa Inhibitors , Pyrazoles , Pyridones , Stroke , Humans , Atrial Fibrillation/drug therapy , Atrial Fibrillation/complications , Pyrazoles/therapeutic use , Pyridones/therapeutic use , Pyridones/adverse effects , Pyridones/administration & dosage , Aspirin/therapeutic use , Male , Female , Aged , Middle Aged , Stroke/prevention & control , Stroke/etiology , Stroke/epidemiology , Factor Xa Inhibitors/therapeutic use , Risk Assessment/methods , Hemorrhage/chemically induced , Hemorrhage/epidemiology
2.
Europace ; 26(8)2024 Aug 03.
Article in English | MEDLINE | ID: mdl-39056247

ABSTRACT

AIMS: Short-term ambulatory electrocardiogram (ECG) monitoring is often used to assess premature atrial complex (PAC) and premature ventricular complex (PVC) frequency, but the diagnostic reliability is unknown. The objective of this study was to study the day-to-day variability of PAC and PVC frequency. METHODS AND RESULTS: We used 14-day full-disclosure mobile cardiac telemetry recordings without atrial fibrillation in 8245 US patients aged 17-103 years to calculate the diagnostic reliability of shorter ambulatory ECG recordings compared with 14-day averages. Over 14 days, 1853 patients had ≥500 PACs/day, 410 patients had ≥5000 PACs/day, and 197 patients had ≥10 000 PACs/day; 1640 patients had ≥500 PVCs/day, 354 patients had ≥5000 PVCs/day, and 175 patients had ≥10 000 PVCs/day. After 3 days, the estimated daily PAC frequency differed by ≥50% from the 14-day mean in 25% of patients; for PVCs, the corresponding duration was 7 days. Ten days of monitoring were needed to estimate PAC and PVC frequency within ±20% of the overall 14-day frequency in 80% of patients. For daily PAC and PVC frequencies ≥10 000, single-day estimation had a specificity of 99.3% [95% confidence interval (CI) 99.1-99.5] at a sensitivity of 76.6 (95% CI 70.1-80.4%) for PACs and a 99.6% (95% CI 99.4-99.7%) specificity at 79.4 (95% CI 72.7-85.2) sensitivity for PVCs. After 7 days, the sensitivity increased to 88.8% (95% CI 83.6-92.9) for PACs and 86.9% (95% CI 80.9-91.5%) for PVCs. CONCLUSION: While there is substantial daily variability across most PAC and PVC levels, findings of ≥10 000 PACs or PVCs are highly specific and do not need to be confirmed with longer recordings.


Subject(s)
Atrial Premature Complexes , Electrocardiography, Ambulatory , Ventricular Premature Complexes , Humans , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/physiopathology , Middle Aged , Aged , Reproducibility of Results , Female , Atrial Premature Complexes/diagnosis , Atrial Premature Complexes/physiopathology , Electrocardiography, Ambulatory/methods , Adult , Male , Adolescent , Aged, 80 and over , Young Adult , Time Factors , Telemetry , Predictive Value of Tests , Heart Rate
3.
J Cardiovasc Electrophysiol ; 35(6): 1095-1100, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38511484

ABSTRACT

INTRODUCTION: In cryoballoon ablation (CBA) procedures, transseptal access (TSA) is generally achieved using a standard sheath and needle system that is exchanged for the cryoballoon delivery sheath and dilator over a long wire. Sheath exchange has been related with air embolic events. Recently, an integrated dilator-needle system assembled to the cryoballoon sheath was introduced. We aimed to evaluate the efficacy and safety of an integrated TSA tool compared with the traditional approach in atrial fibrillation CBA procedures. METHODS: Patients scheduled for CBA procedures were randomized 1:1 to traditional TSA (t-TSA) or integrated TSA (i-TSA). TSA time was defined as time from superior vena cava to LA insertion of the cryoballoon delivery sheath, after sheath exchange (t-TSA) or directly (i-TSA). RESULTS: Ninety-seven patients (76 males, mean age 59 ± 10 years) were randomized, 48 patients underwent t-TSA, and 49 i-TSA. Mean TSA time was 5 min 59 s ± 5 min 36 s in the t-TSA group and 2 min 59 s ± 2 min 14 s in the i-TSA group (p < .001). Total fluoroscopy time, skin-to-skin procedure time, and LA dwell time were respectively 15 ± 6, 69 ± 16, and 44 ± 12 min in the t-TSA group and 13 ± 6, 65 ± 15, and 43 ± 11 min in the i-TSA group (p = ns). No clinically significant acute complications related to TSA were noted in both cohorts. CONCLUSION: This is the first randomized study comparing both TSA approaches. TSA in CBA procedures using this integrated tool enables a safe and efficient workflow, reducing TSA time and avoiding sheath exchange.


Subject(s)
Atrial Fibrillation , Cryosurgery , Equipment Design , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cryosurgery/instrumentation , Cryosurgery/adverse effects , Male , Female , Middle Aged , Aged , Treatment Outcome , Time Factors , Cardiac Catheters , Operative Time , Needles , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Prospective Studies , Heart Rate , Action Potentials
4.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Article in English | MEDLINE | ID: mdl-37952132

ABSTRACT

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Subject(s)
Anticoagulants , Aspirin , Atrial Fibrillation , Embolism , Stroke , Aged , Aged, 80 and over , Female , Humans , Male , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Aspirin/adverse effects , Aspirin/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Canada , Embolism/etiology , Embolism/prevention & control , Hemorrhage/chemically induced , Pyridones/adverse effects , Stroke/etiology , Stroke/prevention & control , Treatment Outcome , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Double-Blind Method
5.
J Arrhythm ; 39(6): 963-964, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38045470

ABSTRACT

The shoehorn technique is a simple and safe maneuver that can help to solve difficulties in challenging transseptal sheath crossing for atrial fibrillation cryoablation procedures.

7.
J Electrocardiol ; 81: 250-252, 2023.
Article in English | MEDLINE | ID: mdl-37862914

ABSTRACT

We present a case of symptomatic intermittent AV block showing during monitorization alternating bundle branch block. Presuming a high need of pacing, conduction system pacing was considered a more physiological alternative in this patient. Left bundle branch pacing restored a stable atrioventricular synchrony with a paced QRS complex similar to the native one and might be a good alternative in these cases.


Subject(s)
Bundle of His , Bundle-Branch Block , Humans , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial , Electrocardiography , Heart Conduction System
10.
J Electrocardiol ; 61: 137-140, 2020.
Article in English | MEDLINE | ID: mdl-32599292

ABSTRACT

ECG of patients with Wolf Parkinson White (WPW) syndrome may simulate other entities such as myocardial infarction, ventricular premature complexes, ventricular bigeminy, accelerated idioventricular rhythm, intermittent bundle branch block or electrical alternans. On the other hand, the opposite can also occur where these other conditions may simulate WPW. We present the case of a young patient referred for WPW ablation showing an incessant accelerated idioventricular rhythm mimicking preexcitation.


Subject(s)
Accelerated Idioventricular Rhythm , Pre-Excitation Syndromes , Wolff-Parkinson-White Syndrome , Bundle-Branch Block/diagnosis , Electrocardiography , Humans , Pre-Excitation Syndromes/diagnosis , Wolff-Parkinson-White Syndrome/diagnosis
12.
Int J Cardiol ; 278: 104-107, 2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30318293

ABSTRACT

Ictal asystole can appear in patients with focal epilepsy, even in early phases. We present our experience of 7 cases, remarking the electrocardiographic characteristics, the role of apnea, treatment and long-term evolution. Awareness of this entity and collaboration between neurologists and cardiologists are essential for a correct diagnosis and management.


Subject(s)
Electrocardiography/methods , Electroencephalography/methods , Epilepsy/diagnosis , Epilepsy/physiopathology , Heart Arrest/diagnosis , Heart Arrest/physiopathology , Adult , Aged , Cardiology/methods , Epilepsy/epidemiology , Female , Heart Arrest/epidemiology , Humans , Male , Middle Aged , Neurology/methods , Retrospective Studies
14.
J Electrocardiol ; 51(6): 941-944, 2018.
Article in English | MEDLINE | ID: mdl-30497752

ABSTRACT

We report on a case of a 78-years-old patient with a subcutaneous implantable cardioverter defibrillator (S-ICD) and an episode of a sustained ventricular tachycardia (VT) at a rate slower than the programmed shock zone. Because of T-wave oversensing the device interpreted it as fast VT that triggered the delivery of an "inappropriately appropriate shock" that terminated it. The patient had again more VT episodes but after programming the SMART pass algorithm (previously programmed "OFF") the device showed no longer frequent T-wave oversensing and no additional inappropriate shocks occurred.


Subject(s)
Algorithms , Defibrillators, Implantable , Tachycardia, Ventricular/physiopathology , Aged , Equipment Failure , Humans , Male
16.
Article in English | MEDLINE | ID: mdl-29856082

ABSTRACT

BACKGROUND: Heart failure (HF) hospitalizations have a negative impact on quality of life and imply important costs. Intrathoracic impedance (ITI) variations detected by cardiac devices have been hypothesized to predict HF hospitalizations. Although Optivol™ algorithm (Medtronic, Minneapolis, MN, USA) has been widely studied, CorVue™ algorithm's (St. Jude Medical, St. Paul, MN, USA) long-term efficacy has not been systematically evaluated in a "real-life" cohort. METHODS: CorVue™ was activated in implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) patients to store information about ITI measures. Clinical events (new episodes of HF requiring treatment and hospitalizations) and CorVue™ data were recorded every 3 months. Appropriate CorVue™ detection for HF was considered if it occurred in the 4 prior weeks to the clinical event. RESULTS: Fifty-three ICD/CRT-D (26 ICD and 27 CRT-D) patients (67 ± 1 years old, 79% male) were included. Device position was subcutaneous in 28 patients. At inclusion, mean left ventricular ejection fraction was 25 ± 7% and 27 patients (51%) were in New York Heart Association class I, 18 (34%) in class II, and eight (15%) in class III. After a mean follow-up of 17 ± 9 months, 105 ITI drops alarms were detected in 32 patients (60%). Only six alarms were appropriate (true positive) and required hospitalization. Eighteen patients (34%) presented 25 clinical episodes (12 hospitalizations and 13 emergency room/ambulatory treatment modifications). Nineteen of these clinical episodes (76%) remained undetected by the CorVue™ (false negative). Sensitivity of CorVue™ resulted in 24%, specificity was 70%, positive predictive value of 6%, and negative predictive value of 93%. CONCLUSIONS: CorVue™ showed a low sensitivity to predict HF events. Therefore, routinely activation of this algorithm could generate misleading information.

17.
J Thorac Dis ; 10(3): 2048-2051, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29707362

ABSTRACT

Today's pacemakers and defibrillators include diagnostic tools for detecting and treating cardiac arrhythmias like silent atrial fibrillation as atrial high rate episodes (AHREs). This diagnostic capability is crucial to prevent the potential embolic complications this AHREs are related to. However, sometimes data retrieved from diagnostic counters may be misleading reflecting limitations of detection algorithms, which must follow mathematical rules to classify events on a beat-to-beat basis. The incorporation of stored electrograms has been an important milestone in improving the diagnostic capabilities of these devices confirming the arrhythmia diagnosis.

18.
J Electrocardiol ; 51(3): 366-369, 2018.
Article in English | MEDLINE | ID: mdl-29779524

ABSTRACT

We present a case series of five patients reporting abnormal automatic mode switching (AMS) episodes during routinary cardiac defibrillator (ICD) and pacemaker (PM) follow-up. This non-previously described phenomenon was reported to St. Jude Medical (Abbott) Technical Support that confirmed the inappropriate automatic mode switching.


Subject(s)
Cardiac Pacing, Artificial , Defibrillators, Implantable , Long QT Syndrome/therapy , Sick Sinus Syndrome/therapy , Tachycardia, Ventricular/therapy , Adult , Aged , Electrophysiologic Techniques, Cardiac , Female , Humans , Long QT Syndrome/physiopathology , Male , Middle Aged , Sick Sinus Syndrome/physiopathology , Tachycardia, Ventricular/physiopathology
19.
Pacing Clin Electrophysiol ; 41(3): 223-228, 2018 03.
Article in English | MEDLINE | ID: mdl-29327362

ABSTRACT

BACKGROUND: The presence of interatrial block (IAB) is associated with the development of atrial fibrillation (AF). The aim of this study was to determine whether P-wave duration and presence of IAB before the implantation of a cardiac implantable electronic device (CIED) are associated with the presence of atrial high rate episodes (AHRE), during long-term follow-up. METHODS: 380 patients (57% men; 75 ± 10 years) were included. IAB was defined according to the International Consensus Criteria. AHRE was defined as an episode of atrial rate ≥225 beats/min with a minimum duration of 5 minutes. RESULTS: Documented paroxysmal AF before the implantation was present in 24% of the patients; 80% had hypertension and 32% structural heart disease. Mean P-wave duration was 123 ± 23 ms, and 39% of the patients had IAB (32% partial, 7% advanced). After a mean follow-up of 18 ± 12 months, 33% of the patients presented AHRE. Patients with AHRE had a P-wave duration significantly longer (130 ± 24 ms vs 119 ± 21 ms; P < 0.001) and a greater prevalence of IAB (53% vs 32%; P < 0.001). In a multivariate analysis, predictors of AHRE were: IAB (odds ratio [OR] 2.1; 95% confidence interval [CI] [1.3-3.4], P < 0.001) and previous paroxysmal AF (OR 2.6; 95% CI [1.5-4.3], P < 0.001). In patients without previous AF, the presence of IAB was also a significant predictor of AHRE (OR 3.1; 95% CI [1.8-5.5], P < 0.001). CONCLUSIONS: IAB is a strong predictor of AHRE in patients with CIED. This finding is independent of the presence of prior paroxysmal AF.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Cardiac Resynchronization Therapy Devices , Heart Rate/physiology , Interatrial Block/diagnosis , Interatrial Block/physiopathology , Aged , Electrocardiography , Female , Humans , Male , Predictive Value of Tests , Prognosis , Risk Factors
20.
SELECTION OF CITATIONS
SEARCH DETAIL