Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 18(4): e0283251, 2023.
Article in English | MEDLINE | ID: mdl-37074997

ABSTRACT

The utilization or secondary use of technogenic waste is a relevant problem for the current economy. To assess the environmental influence and economic potential, it is necessary to study the elemental content of technogenic objects and to reveal the tendencies of the spatial distribution of elements, components, and indices such as the pollution coefficient. In this study, we performed elemental analysis, and calculation of indicators: average gross content, hazard quotients, concentration coefficients of metals, and total pollution coefficients of ground samples taken from the ash-slag storage of the Aksu ferroalloy plant [Aksu, Pavlodar region, Kazakhstan]. Maps of the spatial distribution of concentrations of elements and total pollution coefficients were created. The territory of the studied ash-slag storage by the level of soil contamination should be considered as an environmental disaster zone. The given statistical data on the number of oncological and respiratory diseases indirectly indicated the negative influence of open storage of ash-slag waste. The studied ground was of chromium-manganese geochemical specialization. The calculated volume of the accumulated waste mass by the approximating method was 1 054 638.0 m3. The calculated approximate weight of the accumulated waste was 23 679 576.0864 tons, including 1 822 972.2 tons of chromium, 1 727 354.0 tons of manganese, and 953 813.3 tons of iron. The large amounts of valuable components retained in the waste mass led us to conclude that the studied technogenic object can be considered as a secondary field to produce various technological products. Moreover, valuable metals can be extracted as metal concentrates.


Subject(s)
Manganese , Metals, Heavy , Manganese/analysis , Kazakhstan , Iron/chemistry , Metals/analysis , Chromium/analysis , Environmental Monitoring/methods , Metals, Heavy/analysis
2.
Article in English | MEDLINE | ID: mdl-36554480

ABSTRACT

Poor air quality inside museums can have a double effect; on the one hand, influencing the integrity of the exhibits and on the other hand, endangering the health of employees and visitors. Both components can be very sensitive to the influence of the internal microclimate, therefore careful monitoring of the physical parameters and pollutants is required in order to maintain them within strict limits and thus to reduce the hazards that can be induced. The current study considers the determination and analysis of 15 indicators of the internal microclimate in an Art Nouveau museum built at the beginning of the 20th century in the Municipality of Oradea, Romania. The monitoring spanned a period of seven months, between September 2021 and March 2022, targeting three rooms of the museum with different characteristics and containing exhibits with a high degree of fragility. The results show that, although there are numerous indicators that have exceeded the thresholds induced by international standards, the possible negative impact on the exhibits and/or on human health remains moderate. This is due to the fact that, most of the time, exceeding the permitted limits are small or only sporadic, the values quickly returning to the permitted limits. Thus, only 22 of the 212 days of monitoring recorded marginal conditions regarding the quality of the indoor air, the rest having acceptable and good conditions. To improve the indoor conditions, a more careful management is needed, especially regarding the values of temperature, humidity, particulate matters, natural and artificial light, volatile organic compounds (VOC) and formaldehyde (HCHO), which during the measurements recorded high values that fluctuated in a wide spectrum. The obtained results can represent the basis for the development and implementation of long-term strategies for stabilizing the microclimatic conditions in the museum in order to preserve the exhibits preventively and to ensure a clean and safe environment for people.


Subject(s)
Air Pollutants , Air Pollution, Indoor , Air Pollution , Humans , Air Pollutants/analysis , Air Pollution, Indoor/analysis , Microclimate , Air Pollution/analysis , Particulate Matter/analysis , Environmental Monitoring
SELECTION OF CITATIONS
SEARCH DETAIL
...