Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
BMC Anesthesiol ; 24(1): 82, 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38413871

ABSTRACT

BACKGROUND: Inadequate intraoperative mechanical ventilation (MV) can lead to ventilator-induced lung injury and increased risk for postoperative pulmonary complications (PPCs). Mechanical power (MP) was shown to be a valuable indicator for MV outcomes in critical care patients. The aim of this study is to assess the association between intraoperative MP in low-risk surgical patients undergoing general anesthesia and PPCs. METHODS: Two-hundred eighteen low-risk surgical patients undergoing general anesthesia for elective surgery were included in the study. Intraoperative mechanical ventilatory support parameters were collected for all patients. Postoperatively, patients were followed throughout their hospital stay and up to seven days post discharge for the occurrence of any PPCs. RESULTS: Out of 218 patients, 35% exhibited PPCs. The average body mass index, tidal volume per ideal body weight, peak inspiratory pressure, and MP were significantly higher in the patients with PPCs than in the patients without PPCs (30.3 ± 8.1 kg/m2 vs. 26.8 ± 4.9 kg.m2, p < 0.001; 9.1 ± 1.9 ml/kg vs. 8.6 ± 1.4 ml/kg, p = 0.02; 20 ± 4.9 cmH2O vs. 18 ± 3.7 cmH2O, p = 0.001; 12.9 ± 4.5 J/min vs. 11.1 ± 3.7 J/min, p = 0.002). A multivariable regression analysis revealed MP as the sole significant predictor for the risk of postoperative pulmonary complications [OR 1.1 (95% CI 1.0-1.2, p = 0.036]. CONCLUSIONS: High intraoperative mechanical power is a risk factor for developing postoperative pulmonary complications. Furthermore, intraoperative mechanical power is superior to other traditional mechanical ventilation variables in identifying surgical patients who are at risk for developing postoperative pulmonary complications. CLINICAL TRIAL REGISTRATION: NCT03551899; 24/02/2017.


Subject(s)
Aftercare , Patient Discharge , Humans , Prospective Studies , Lung , Respiration, Artificial/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Tidal Volume
2.
A A Pract ; 17(9): e01722, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37703136

ABSTRACT

Autonomic dysfunction can lead to unexpected hemodynamic instability during surgery, and best practices for the perioperative care of patients with this condition are not well-defined. We report the case of a 63-year-old woman with Charcot-Marie-Tooth disease who experienced perioperative autonomic dysfunction characterized by severe fluctuations in blood pressure while under spinal anesthesia. However, <1 month later, a second hip surgery performed under general anesthesia with special precautions resulted in an uncomplicated perioperative course, with only mild fluctuations in blood pressure.


Subject(s)
Anesthesia, Spinal , Charcot-Marie-Tooth Disease , Female , Humans , Middle Aged , Charcot-Marie-Tooth Disease/complications , Anesthesia, General , Blood Pressure , Perioperative Care
3.
Anesth Analg ; 136(1): 25-33, 2023 01 01.
Article in English | MEDLINE | ID: mdl-35213484

ABSTRACT

BACKGROUND: The removal of the laryngeal mask airway (LMA®) in children may be associated with respiratory adverse events. The rate of occurrence of these adverse events may be influenced by the type of anesthesia. Studies comparing total intravenous anesthesia (TIVA) with propofol and sevoflurane are limited with conflicting data whether propofol is associated with a lower incidence of respiratory events upon removal of LMA as compared to induction and maintenance with sevoflurane. We hypothesized that TIVA with propofol is superior to sevoflurane in providing optimal conditions and improved patient's safety during emergence. METHODS: In this prospective, randomized, double-blind clinical trial, children aged 6 months to 7 years old were enrolled in 1 of 2 groups: the TIVA group and the sevoflurane group. In both groups, patients were mechanically ventilated. At the end of the procedure, LMAs were removed when patients were physiologically and neurologically recovered to a degree to permit a safe, natural airway. The primary aim of this study was to compare the occurrence of at least 1 respiratory adverse event, the prevalence of individual respiratory adverse events, and the airway hyperreactivity score following emergence from anesthesia between the 2 groups. Secondary outcomes included ease of LMA insertion, quality of anesthesia during the maintenance phase, hemodynamic stability, time to LMA removal, and incidence of emergence agitation. RESULTS: Children receiving TIVA with propofol had a significantly lower incidence (10.8.% vs 36.2%; relative risk, 0.29; 95% CI [0.14-0.64]; P = .001) and lower severity ( P = .01) of respiratory adverse outcomes compared to the patients receiving inhalational anesthesia with sevoflurane. There were no statistically significant differences in secondary outcomes between the 2 groups, except for emergence agitation that occurred more frequently in patients receiving sevoflurane ( P < .001). CONCLUSIONS: Propofol induction and maintenance exerted a protective effect on healthy children with minimal risk factors for developing perioperative respiratory complications, as compared to sevoflurane.


Subject(s)
Anesthetics, Inhalation , Emergence Delirium , Laryngeal Masks , Methyl Ethers , Propofol , Humans , Child , Propofol/adverse effects , Sevoflurane , Laryngeal Masks/adverse effects , Emergence Delirium/etiology , Prospective Studies , Anesthesia, Inhalation/adverse effects , Anesthetics, Intravenous
5.
Int J Artif Organs ; 45(2): 152-154, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33583241

ABSTRACT

The use of left ventricular assist device (LVAD) in patients with mechanical aortic valves may result in thromboembolic events due to blood stasis around the valve and intermittent valve opening. Mechanical aortic valves encountered during LVAD implantation are managed by replacement with a tissue valve, or closure of the valve with a patch. Closure of the valve carries the risk of sudden death in cases of LVAD stoppage. Replacing the whole mechanical valve conduit is time consuming and carries a significant risk of bleeding and right ventricular (RV) failure. We describe an alternative technique of replacing a mechanical aortic valve by breaking its inner leaflets and sewing a tissue valve on top of the mechanical valve ring.


Subject(s)
Aortic Valve Insufficiency , Heart Failure , Heart-Assist Devices , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Humans , Treatment Outcome
7.
Clin Genitourin Cancer ; 15(6): e1029-e1037, 2017 12.
Article in English | MEDLINE | ID: mdl-28669704

ABSTRACT

BACKGROUND: Limited studies examined effects of pneumoperiotneum during robot-assisted radical prostatectomy (RARP) and with AirSeal. The aim of this study was to assess the effect on hemodynamics of a lower pressure pneumoperitoneum (8 mmHg) with AirSeal, during RARP in steep Trendelenburg 45° (ST). MATERIALS AND METHODS: This is an institutional review board-approved, prospective, interventional, single-center study including patients treated with RARP at OLV Hospital by one extremely experienced surgeon (July 2015-February 2016). Intraoperative monitoring included: arterial pressure, central venous pressure, cardiac output, heart rate, stroke volume, systemic vascular resistance, intrathoracic pressure, airways pressures, left ventricular end-diastolic and end-systolic areas/volumes and ejection fraction, by transesophageal echocardiography, an esophageal catheter, and FloTrac/Vigileo system. Measurements were performed after induction of anesthesia with patient in horizontal (T0), 5 minutes after 8 mmHg pneumoperitoneum (TP), 5 minutes after ST (TT1) and every 30 minutes thereafter until the end of surgery (TH). Parameters modification at the prespecified times was assessed by Wilcoxon and Friedman tests, as appropriate. All analyses were performed by SPSS v. 23.0. RESULTS: A total of 53 consecutive patients were enrolled. The mean patients age was 62.6 ± 6.9 years. Comorbidity was relatively limited (51% with Charlson Comorbidity Index as low as 0). Despite the ST, working always at 8 mmHg with AirSeal, only central venous pressure and mean airways pressure showed a statistically significant variation during the operative time. Although other significant hemodynamic/respiratory changes were observed adding pneumoperitoneum and then ST, all variables remained always within limits safely manageable by anesthesiologists. CONCLUSION: The combination of ST, lower pressure pneumoperitoneum and extreme surgeon's experience enables to safely perform RARP.


Subject(s)
Pneumoperitoneum/epidemiology , Prostatectomy/instrumentation , Robotic Surgical Procedures/adverse effects , Aged , Blood Pressure , Hemodynamics , Humans , Male , Middle Aged , Monitoring, Intraoperative , Operative Time , Pneumoperitoneum/etiology , Prospective Studies , Prostatectomy/adverse effects
9.
PLoS One ; 7(11): e49532, 2012.
Article in English | MEDLINE | ID: mdl-23226213

ABSTRACT

Tricuspid Atresia (TA) is a rare form of congenital heart disease (CHD) with usually poor prognosis in humans. It presents as a complete absence of the right atrio-ventricular connection secured normally by the tricuspid valve. Defects in the tricuspid valve are so far not associated with any genetic locus, although mutations in numerous genes were linked to multiple forms of congenital heart disease. In the last decade, Knock-out mice have offered models for cardiologists and geneticists to study the causes of congenital disease. One such model was the Nfatc1(-/-) mice embryos which die at mid-gestation stage due to a complete absence of the valves. NFATC1 belongs to the Rel family of transcription factors members of which were shown to be implicated in gene activation, cell differentiation, and organogenesis. We have previously shown that a tandem repeat in the intronic region of NFATC1 is associated with ventricular septal defects. In this report, we unravel for the first time a potential link between a mutation in NFATC1 and TA. Two heterozygous missense mutations were found in the NFATC1 gene in one indexed-case out of 19 patients with TA. The two amino-acids changes were not found neither in other patients with CHDs, nor in the control healthy population. Moreover, we showed that these mutations alter dramatically the normal function of the protein at the cellular localization, DNA binding and transcriptional levels suggesting they are disease-causing.


Subject(s)
NFATC Transcription Factors/genetics , Polymorphism, Single Nucleotide , Transcription, Genetic , Tricuspid Atresia/genetics , Tricuspid Valve/metabolism , Adolescent , Alleles , Amino Acid Sequence , Base Sequence , Case-Control Studies , Cell Line, Tumor , Genes, Reporter , Genotype , Heterozygote , Humans , Luciferases , Male , Molecular Sequence Data , Mutagenesis, Site-Directed , Phenotype , Sequence Analysis, DNA , Transfection , Tricuspid Atresia/pathology , Tricuspid Valve/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...