Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 91
Filter
Add more filters










Publication year range
1.
Nat Commun ; 15(1): 3973, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38729944

ABSTRACT

Ultra-fast single-photon detectors with high current density and operating temperature can benefit space and ground applications, including quantum optical communication systems, lightweight cryogenics for space crafts, and medical use. Here we demonstrate magnesium diboride (MgB2) thin-film superconducting microwires capable of single-photon detection at 1.55 µm optical wavelength. We used helium ions to alter the properties of MgB2, resulting in microwire-based detectors exhibiting single-photon sensitivity across a broad temperature range of up to 20 K, and detection efficiency saturation for 1 µm wide microwires at 3.7 K. Linearity of detection rate vs incident power was preserved up to at least 100 Mcps. Despite the large active area of up to 400 × 400 µm2, the reset time was found to be as low as ~ 1 ns. Our research provides possibilities for breaking the operating temperature limit and maximum single-pixel count rate, expanding the detector area, and raises inquiries about the fundamental mechanisms of single-photon detection in high-critical-temperature superconductors.

2.
Ultramicroscopy ; 245: 113662, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36521266

ABSTRACT

Scanning electron microscopy (SEM) is a versatile technique used to image samples at the nanoscale. Conventional imaging by this technique relies on finding the average intensity of the signal generated on a detector by secondary electrons (SEs) emitted from the sample and is subject to noise due to variations in the voltage signal from the detector. This noise can result in degradation of the SEM image quality for a given imaging dose. SE count imaging, which uses the direct count of SEs detected from the sample instead of the average signal intensity, would overcome this limitation and lead to improvement in SEM image quality. In this paper, we implement an SE count imaging scheme by synchronously outcoupling the detector and beam scan signals from the microscope and using custom code to count detected SEs. We demonstrate a ∼30% increase in the image signal-to-noise-ratio due to SE counting compared to conventional imaging. The only external hardware requirement for this imaging scheme is an oscilloscope fast enough to accurately sample the detector signal for SE counting, making the scheme easily implementable on any SEM.

3.
Nat Commun ; 13(1): 5429, 2022 Sep 16.
Article in English | MEDLINE | ID: mdl-36114177

ABSTRACT

Controlling thermal transport is important for a range of devices and technologies, from phase change memories to next-generation electronics. This is especially true in nano-scale devices where thermal transport is altered by the influence of surfaces and changes in dimensionality. In superconducting nanowire single-photon detectors, the thermal boundary conductance between the nanowire and the substrate it is fabricated on influences all of the performance metrics that make these detectors attractive for applications. This includes the maximum count rate, latency, jitter, and quantum efficiency. Despite its importance, the study of thermal boundary conductance in superconducting nanowire devices has not been done systematically, primarily due to the lack of a straightforward characterization method. Here, we show that simple electrical measurements can be used to estimate the thermal boundary conductance between nanowires and substrates and that these measurements agree with acoustic mismatch theory across a variety of substrates. Numerical simulations allow us to refine our understanding, however, open questions remain. This work should enable thermal engineering in superconducting nanowire electronics and cryogenic detectors for improved device performance.

4.
Nano Lett ; 22(14): 5667-5673, 2022 07 27.
Article in English | MEDLINE | ID: mdl-35848767

ABSTRACT

The optimization of superconducting thin-films has pushed the sensitivity of superconducting nanowire single-photon detectors (SNSPDs) to the mid-infrared (mid-IR). Earlier demonstrations have shown that straight tungsten silicide nanowires can achieve unity internal detection efficiency (IDE) up to λ = 10 µm. For a high system detection efficiency (SDE), the active area needs to be increased, but material nonuniformity and nanofabrication-induced constrictions make mid-IR large-area meanders challenging to yield. In this work, we improve the sensitivity of superconducting materials and optimize a high-resolution nanofabrication process to demonstrate large-area SNSPDs with unity IDE at 7.4 µm. Our approach yields large-area meanders down to 50 nm width, with average line-width roughness below 10%, and with a lower impact from constrictions compared to previous demonstrations. Our methods pave the way to high-efficiency SNSPDs in the mid-IR band with potential impacts on astronomy, imaging, and physical chemistry.


Subject(s)
Nanowires , Electric Conductivity , Equipment Design , Photometry , Photons
5.
ACS Nano ; 16(8): 12930-12940, 2022 08 23.
Article in English | MEDLINE | ID: mdl-35849731

ABSTRACT

Short-wave infrared (SWIR; 850-1700 nm) upconversion fluorescence enables "autofluorescence-free" imaging with minimal tissue scattering, yet it is rarely explored due to the lack of strongly emissive SWIR upconversion fluorophores. In this work, we apply SWIR upconversion fluorescence for in vivo imaging with exceptional image contrast. Gold nanorods (AuNRs) are used to enhance the SWIR upconversion emission of small organic dyes, forming a AuNR-dye nanocomposite (NC). A maximal enhancement factor of ∼1320, contributed by both excitation and radiative decay rate enhancement, is achieved by varying the dye-to-AuNR ratio. In addition, the upconversion emission intensity of both free dyes and AuNR-dye NCs depends linearly on the excitation power, indicating that the upconversion emission mechanism remains unchanged upon enhancement, and it involves one-photon absorption. Moreover, the SWIR upconversion emission shows a significantly higher signal contrast than downconversion emission in the same emission window in a nonscattering medium. Finally, we apply the surface plasmon enhanced SWIR upconversion fluorescence for in vivo imaging of ovarian cancer, demonstrating high image contrast and low required dosage due to the suppressed autofluorescence.


Subject(s)
Fluorescent Dyes , Ovarian Neoplasms , Humans , Female , Fluorescence , Gold , Diagnostic Imaging , Ovarian Neoplasms/diagnostic imaging
6.
Phys Rev Lett ; 128(23): 231802, 2022 Jun 10.
Article in English | MEDLINE | ID: mdl-35749181

ABSTRACT

Uncovering the nature of dark matter is one of the most important goals of particle physics. Light bosonic particles, such as the dark photon, are well-motivated candidates: they are generally long-lived, weakly interacting, and naturally produced in the early universe. In this work, we report on Light A^{'} Multilayer Periodic Optical SNSPD Target, a proof-of-concept experiment searching for dark photon dark matter in the eV mass range, via coherent absorption in a multilayer dielectric haloscope. Using a superconducting nanowire single-photon detector (SNSPD), we achieve efficient photon detection with a dark count rate of ∼6×10^{-6} counts/s. We find no evidence for dark photon dark matter in the mass range of ∼0.7-0.8 eV with kinetic mixing ε≳10^{-12}, improving existing limits in ε by up to a factor of 2. With future improvements to SNSPDs, our architecture could probe significant new parameter space for dark photon and axion dark matter in the meV to 10 eV mass range.

7.
PLoS One ; 17(6): e0265816, 2022.
Article in English | MEDLINE | ID: mdl-35679278

ABSTRACT

We probed the transmission of COVID-19 by applying an airborne transmission model to five well-documented case studies-a Washington state church choir, a Korean call center, a Korean exercise class, and two different Chinese bus trips. For all events the likely index patients were pre-symptomatic or mildly symptomatic, which is when infective patients are most likely to interact with large groups of people. Applying the model to those events yields results that suggest the following: (1) transmission was airborne; (2) superspreading events do not require an index patient with an unusually high viral load; (3) the viral loads for all of the index patients were of the same order of magnitude and consistent with experimentally measured values for patients at the onset of symptoms, even though viral loads across the population vary by a factor of >108. In particular we used a Wells-Riley exposure model to calculate q, the total average number of infectious quanta inhaled by a person at the event. Given the q value for each event, the simple airborne transmission model was used to determined Sq, the rate at which the index patient exhaled infectious quanta and N0, the characteristic number of COVID-19 virions needed to induce infection. Despite the uncertainties in the values of some parameters of the superspreading events, all five events yielded (N0∼300-2,000 virions), which is similar to published values for influenza. Finally, this work describes the conditions under which similar methods can provide actionable information on the transmission of other viruses.


Subject(s)
COVID-19 , Influenza, Human , COVID-19/epidemiology , Exhalation , Humans , Serologic Tests , Viral Load
8.
Phys Rev Lett ; 128(13): 131801, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35426699

ABSTRACT

We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [10^{-3},1] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry enables enclosure in standard cryostats and high-field solenoids, overcoming limitations of current dish antennas. A pilot 0.7 m^{2} barrel experiment planned at Fermilab is projected to surpass existing dark photon coupling constraints by over a decade with one-day runtime. Axion sensitivity requires <10^{-20} W/sqrt[Hz] sensor noise equivalent power with a 10 T solenoid and 10 m^{2} barrel. We project BREAD sensitivity for various sensor technologies and discuss future prospects.

9.
Phys Rev Lett ; 127(15): 151802, 2021 Oct 08.
Article in English | MEDLINE | ID: mdl-34678036

ABSTRACT

We show that the rate for dark-matter-electron scattering in an arbitrary material is determined by an experimentally measurable quantity, the complex dielectric function, for any dark matter interaction that couples to electron density. This formulation automatically includes many-body effects, eliminates all systematic theoretical uncertainties on the electronic wave functions, and allows a direct calibration of the spectrum by electromagnetic probes such as infrared spectroscopy, x-ray scattering, and electron energy-loss spectroscopy. Our formalism applies for several common benchmark models, including spin-independent interactions through scalar and vector mediators of arbitrary mass. We discuss the consequences for standard semiconductor and superconductor targets and find that the true reach of superconductor detectors for light mediators exceeds previous estimates by several orders of magnitude, with further enhancements possible due to the low-energy tail of the plasmon. Using a heavy-fermion superconductor as an example, we show how our formulation allows a rapid and systematic investigation of novel electron scattering targets.

11.
Rev Sci Instrum ; 92(7): 074704, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34340436

ABSTRACT

In this work, we report the use of commercial gallium nitride (GaN) power electronics to precisely switch complex distributed loads, such as electron lenses and deflectors. This was accomplished by taking advantage of the small form-factor, low-power dissipation, and high temperature compatibility of GaN field effect transistors (GaNFETs) to integrate pulsers directly into the loads to be switched, even under vacuum. This integration reduces parasitics to allow for faster switching and removes the requirement to impedance match the load to a transmission line by allowing for a lumped element approximation of the load even with subnanosecond switching. Depending on the chosen GaNFET and driver, these GaN pulsers are capable of generating pulses ranging from 100 to 650 V and 5 to 60 A in 0.25-8 ns using simple designs with easy control, few-nanosecond propagation delays, and MHz repetition rates. We experimentally demonstrate a simple 250 ps, 100 V pulser measured by using a directly coupled 2 GHz oscilloscope. By introducing resistive dampening, we can eliminate ringing to allow for precise 100 V transitions that complete a -10 to -90 V transition in 1.5 ns, limited primarily by the inductance of the oscilloscope measurement path. The performance of the pulser attached to various load structures is simulated, demonstrating the possibility of even faster switching of internal fields in these loads. We test these circuits under vacuum and up to 120 °C to demonstrate their flexibility. We expect these GaN pulsers to have broad application in fields such as optics, nuclear sciences, charged particle optics, and atomic physics that require nanosecond, high-voltage transitions.

12.
Ultramicroscopy ; 226: 113304, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33964613

ABSTRACT

The use of electron mirrors in aberration correction and surface-sensitive microscopy techniques such as low-energy electron microscopy has been established. However, in this work, by implementing an easy to construct, fully electrostatic electron mirror system under a sample in a conventional scanning electron microscope (SEM), we present a new imaging scheme which allows us to form scanned images of the top and bottom surfaces of the sample simultaneously. We believe that this imaging scheme could be of great value to the field of in-situ SEM which has been limited to observation of dynamic changes such as crack propagation and other surface phenomena on one side of samples at a time. We analyze the image properties when using a flat versus a concave electron mirror system and discuss two different regimes of operation. In addition to in-situ SEM, we foresee that our imaging scheme could open up avenues towards spherical aberration correction by the use of electron mirrors in SEMs without the need for complex beam separators.

13.
Ultramicroscopy ; 224: 113238, 2021 May.
Article in English | MEDLINE | ID: mdl-33706085

ABSTRACT

Scanning electron microscopy is a powerful tool for nanoscale imaging of organic and inorganic materials. An important metric for characterizing the limits of performance of these microscopes is the Detective Quantum Efficiency (DQE), which measures the fraction of emitted secondary electrons (SEs) that are detected by the SE detector. However, common techniques for measuring DQE approximate the SE emission process to be Poisson distributed, which can lead to incorrect DQE values. In this paper, we introduce a technique for measuring DQE in which we directly count the mean number of secondary electrons detected from a sample using image histograms. This technique does not assume Poisson distribution of SEs and makes it possible to accurately measure DQE for a wider range of imaging conditions. As a demonstration of our technique, we map the variation of DQE as a function of working distance in the microscope.

14.
Nano Lett ; 21(1): 91-98, 2021 Jan 13.
Article in English | MEDLINE | ID: mdl-33347300

ABSTRACT

The field confinement of plasmonic systems enables spectral tunability under structural variations or environmental perturbations, which is the principle for various applications including nanorulers, sensors, and color displays. Here, we propose and demonstrate that materials with anomalous dispersion, such as Ge in the visible, improve spectral tunability. We introduce our proposal with a semianalytical guided mode picture. Using Ge-based film (Ag/Au)-coupled gap plasmon resonators, we implement two architectures and demonstrate the improved tunability with single-particle dark-field scattering, ensemble reflection, and color generation. We observe three-fold enhancement of tunability with Ge nanodisks compared with that of Si, a normal-dispersion material in the visible. The structural color generation of large array systems, made of inversely fabricated Ge-Ag resonators, exhibits a wide gamut. Our results introduce anomalous material dispersion as an extra degree of freedom to engineer the spectral tunability of plasmonic systems, especially relevant for actively tunable plasmonics and metasurfaces.

15.
Opt Express ; 28(19): 27405-27414, 2020 Sep 14.
Article in English | MEDLINE | ID: mdl-32988035

ABSTRACT

We theoretically investigated electron energy loss spectroscopy (EELS) of ultraviolet surface plasmon modes in aluminum nanodisks. Using full-wave Maxell electromagnetic simulations, we studied the impact of the diameter on the resonant modes of the nanodisks. We found that the mode behavior can be separately classified for two distinct cases: (1) flat nanodisks where the diameter is much larger than the thickness and (2) thick nanodisks where the diameter is comparable to the thickness. While the multipolar edge modes and breathing modes of flat nanostructures have previously been interpreted using intuitive, analytical models based on surface plasmon polariton (SPP) modes of a thin-film stack, it has been found that the true dispersion relation of the multipolar edge modes deviates significantly from the SPP dispersion relation. Here, we developed a modified intuitive model that uses effective wavelength theory to accurately model this dispersion relation with significantly less computational overhead compared to full-wave Maxwell electromagnetic simulations. However, for the case of thick nanodisks, this effective wavelength theory breaks down, and such intuitive models are no longer viable. We found that this is because some modes of the thick nanodisks carry a polar (i.e., out of the substrate plane or along the electron beam direction) dependence and cannot be simply categorized as radial breathing modes or angular (azimuthal) multipolar edge modes. This polar dependence leads to radiative losses, motivating the use of simultaneous EELS and cathodoluminescence measurements when experimentally investigating the complex mode behavior of thick nanostructures.

16.
Ultramicroscopy ; 217: 113053, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32623205

ABSTRACT

Electron beams can acquire designed phase modulations by passing through nanostructured material phase plates. These phase modulations enable electron wavefront shaping and benefit electron microscopy, spectroscopy, lithography, and interferometry. However, in the fabrication of electron phase plates, the typically used focused-ion-beam-milling method limits the fabrication throughput and hence the active area of the phase plates. Here, we fabricated large-area electron phase plates with electron-beam lithography and reactive-ion-etching. The phase plates are characterized by electron diffraction in transmission electron microscopes with various electron energies, as well as diffractive imaging in a scanning electron microscope. We found the phase plates could produce a null in the center of the bright-field based on coherent interference of diffractive beams. Our work adds capabilities to the fabrication of electron phase plates. The nullification of the direct beam and the tunable diffraction efficiency demonstrated here also paves the way towards novel dark-field electron-microscopy techniques.

17.
Nat Commun ; 11(1): 3407, 2020 Jul 08.
Article in English | MEDLINE | ID: mdl-32641698

ABSTRACT

Ultrafast, high-intensity light-matter interactions lead to optical-field-driven photocurrents with an attosecond-level temporal response. These photocurrents can be used to detect the carrier-envelope-phase (CEP) of short optical pulses, and enable optical-frequency, petahertz (PHz) electronics for high-speed information processing. Despite recent reports on optical-field-driven photocurrents in various nanoscale solid-state materials, little has been done in examining the large-scale electronic integration of these devices to improve their functionality and compactness. In this work, we demonstrate enhanced, on-chip CEP detection via optical-field-driven photocurrents in a monolithic array of electrically-connected plasmonic bow-tie nanoantennas that are contained within an area of hundreds of square microns. The technique is scalable and could potentially be used for shot-to-shot CEP tagging applications requiring orders-of-magnitude less pulse energy compared to alternative ionization-based techniques. Our results open avenues for compact time-domain, on-chip CEP detection, and inform the development of integrated circuits for PHz electronics as well as integrated platforms for attosecond and strong-field science.

18.
Nano Lett ; 20(5): 3858-3863, 2020 May 13.
Article in English | MEDLINE | ID: mdl-32271591

ABSTRACT

Time- and number-resolved photon detection is crucial for quantum information processing. Existing photon-number-resolving (PNR) detectors usually suffer from limited timing and dark-count performance or require complex fabrication and operation. Here, we demonstrate a PNR detector at telecommunication wavelengths based on a single superconducting nanowire with an integrated impedance-matching taper. The taper provides a kΩ load impedance to the nanowire, making the detector's output amplitude sensitive to the number of photon-induced hotspots. The prototyping device was able to resolve up to four absorbed photons with 16.1 ps timing jitter and <2 c.p.s. device dark count rate. Its exceptional distinction between single- and two-photon responses is ideal for high-fidelity coincidence counting and allowed us to directly observe bunching of photon pairs from a single output port of a Hong-Ou-Mandel interferometer. This detector architecture may provide a practical solution to applications that require high timing resolution and few-photon discrimination.

19.
Ultramicroscopy ; 211: 112948, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32171978

ABSTRACT

Focused ion beam microscopy suffers from source shot noise - random variation in the number of incident ions in any fixed dwell time - along with random variation in the number of detected secondary electrons per incident ion. This multiplicity of sources of randomness increases the variance of the measurements and thus worsens the trade-off between incident ion dose and image accuracy. Repeated measurement with low dwell time, without changing the total ion dose, is a way to introduce time resolution to this form of microscopy. Through theoretical analyses and Monte Carlo simulations, we show that three ways to process time-resolved measurements result in mean-squared error (MSE) improvements compared to the conventional method of having no time resolution. In particular, maximum likelihood estimation provides reduction in MSE or reduction in required dose by a multiplicative factor approximately equal to the secondary electron yield. This improvement factor is similar to complete mitigation of source shot noise. Experiments with a helium ion microscope are consistent with the analyses and suggest accuracy improvement for a fixed source dose by a factor of about 4.

20.
ACS Appl Mater Interfaces ; 12(9): 10852-10857, 2020 Mar 04.
Article in English | MEDLINE | ID: mdl-32024362

ABSTRACT

In this study, the orientation of block copolymer (BCP) patterns in topographical templates is controlled using a simple template design rule. The orientation of the pattern is selected by using a template with one commensurate dimension and one incommensurate dimension. An array of binary states of a BCP pattern can be programmed into a desired layout by tuning of the template wall thickness.

SELECTION OF CITATIONS
SEARCH DETAIL
...