Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
1.
Front Immunol ; 15: 1404846, 2024.
Article in English | MEDLINE | ID: mdl-38774881

ABSTRACT

Lysosomes and lysosome related organelles (LROs) are dynamic organelles at the intersection of various pathways involved in maintaining cellular hemostasis and regulating cellular functions. Vesicle trafficking of lysosomes and LROs are critical to maintain their functions. The lysosomal trafficking regulator (LYST) is an elusive protein important for the regulation of membrane dynamics and intracellular trafficking of lysosomes and LROs. Mutations to the LYST gene result in Chédiak-Higashi syndrome, an autosomal recessive immunodeficiency characterized by defective granule exocytosis, cytotoxicity, etc. Despite eight decades passing since its initial discovery, a comprehensive understanding of LYST's function in cellular biology remains unresolved. Accumulating evidence suggests that dysregulation of LYST function also manifests in other disease states. Here, we review the available literature to consolidate available scientific endeavors in relation to LYST and discuss its relevance for immunomodulatory therapies, regenerative medicine and cancer applications.


Subject(s)
Lysosomes , Vesicular Transport Proteins , Humans , Lysosomes/metabolism , Vesicular Transport Proteins/metabolism , Vesicular Transport Proteins/genetics , Animals , Chediak-Higashi Syndrome/genetics , Protein Transport , Mutation
2.
JTCVS Open ; 13: 330-343, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37063164

ABSTRACT

Objective: Pulmonary artery reconstruction during comprehensive stage 2 (CS2) procedure can be challenging. Since 2017, we have employed preemptive left pulmonary artery (LPA) stenting. We hypothesized that LPA stenting promotes adequate growth and without compromising Fontan candidacy. Herewith, we report our midterm results. Methods: From 2002 to 2020, 159 patients underwent CS2. Patients were divided as follows: no stent (n = 122; Group 1) and perioperative LPA stent (n = 37; Group 2). Group 2 was subdivided according to unplanned stent (n = 17; Group 2a) or preemptive stent (n = 20; Group 2b). Relevant perioperative data was reviewed. Nonparametric statistics were utilized. Results: Median age and weight at surgery and hospital length of stay after CS2 did not differ between groups. Median cardiopulmonary bypass and crossclamp times were significantly greater in Group 1 (265 vs 243 minutes [P = .021] and 46 vs 26 minutes [P = .008]). In-hospital mortality was similar between Groups 1 and 2 (9.0% vs 18.9%, respectively [P = .1348]). Group 2b demonstrated a superior survival compared to Group 2a (P = .0335) but not Group 1 (P > .9999). Preemptive stenting significantly increased median hilar LPA diameter at CS2 exit angiogram compared with no stenting (P < .0001). Groups 2a and 2b significantly increased the pre-Fontan diameter of the hilar LPA when compared with Group 1 (6.1 and 6.8 vs 5.7 mm, respectively [P < .0001]). A further 120 patients underwent Fontan operation (75%). Median follow-up for Groups 1 and 2 were 7.4 and 3.0 years, respectively. Conclusions: Perioperative LPA stenting during CS2 does not adversely affect pulmonary growth. Preemptive stenting seems advantageous for LPA growth in preparation for Fontan completion.

3.
Hand (N Y) ; 18(5): 780-784, 2023 07.
Article in English | MEDLINE | ID: mdl-34991355

ABSTRACT

Background: In 2015, the American Association of Plastic Surgeons (AAPS) published a consensus statement against the routine use of preoperative antibiotic prophylaxis to prevent surgical site infection in clean hand surgery. The American Academy of Orthopaedic Surgeons (AAOS) similarly cited "insufficient evidence" in its Appropriate Use Criteria guidelines to support the use of antibiotics in carpal tunnel surgery. Nonetheless, its administration remains a common practice during clean hand surgery. We sought to evaluate the impact of the above guidelines on preoperative antibiotic administration. Methods: An institutional review board-approved retrospective chart review of consecutive patients with carpal tunnel syndrome treated with open carpal tunnel release (CTR) at our institution was performed in the 2 years before and after publication of AAPS/AAOS guidelines. Patient demographics and surgical outcomes were reviewed. Incidence of antibiotic administration, patient demographics, and surgeon factors were collected. Results: A total of 770 primary open CTR procedures were performed in the studied years. In 2013 and 2014, 83.9% of patients received preoperative antibiotics. In 2017 and 2018, 48.2% of patients received preoperative antibiotics. Of the variables analyzed, immunosuppression, history of diabetes, and poorly controlled diabetes (A1c > 7) were found to be statistically significant in its positive correlation to prophylactic preoperative antibiotic use. Diabetes was not associated with surgical site infections. Conclusion: Patients were more likely to receive preoperative antibiotics before the publication of the AAPS/AAOS clinical practice guidelines. Patients with diabetes regardless of their glycemic control are more likely to receive preoperative antibiotics.


Subject(s)
Carpal Tunnel Syndrome , Orthopedics , Humans , Anti-Bacterial Agents/therapeutic use , Antibiotic Prophylaxis , Carpal Tunnel Syndrome/surgery , Retrospective Studies , United States , Practice Guidelines as Topic
4.
Hand (N Y) ; 18(6): 912-917, 2023 09.
Article in English | MEDLINE | ID: mdl-35081825

ABSTRACT

Background: Dupuytren disease creates thickened cords of the palmar fascia, leading to progressive flexion contractures that severely hinder hand function. Collagenase clostridium histolyticum (CCH) injection is a common, minimally invasive alternative to surgical excision of these cords. The impact of CCH injection on the histological architecture of Dupuytren cords has not been studied extensively. Methods: A series of 10 CCH-injected cords were evaluated histologically. Cellularity, architecture, and connective tissue organization were compared against uninjected Dupuytren cords and normal palmar fascia. Results: No significant histopathological differences between CCH-injected and CCH-uninjected cords were identified. Conclusions: Dupuytren cords do not demonstrate histological changes with prior exposure to CCH.


Subject(s)
Dupuytren Contracture , Microbial Collagenase , Humans , Microbial Collagenase/therapeutic use , Treatment Outcome , Injections, Intralesional , Dupuytren Contracture/drug therapy
5.
Commun Med (Lond) ; 2: 3, 2022.
Article in English | MEDLINE | ID: mdl-35603301

ABSTRACT

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

6.
FASEB J ; 35(10): e21849, 2021 10.
Article in English | MEDLINE | ID: mdl-34473380

ABSTRACT

Macrophages are a critical driver of neovessel formation in tissue-engineered vascular grafts (TEVGs), but also contribute to graft stenosis, a leading clinical trial complication. Macrophage depletion via liposomal delivery of clodronate, a first-generation bisphosphonate, mitigates stenosis, but simultaneously leads to a complete lack of tissue development in TEVGs. This result and the associated difficulty of utilizing liposomal delivery means that clodronate may not be an ideal means of preventing graft stenosis. Newer generation bisphosphonates, such as zoledronate, may have differential effects on graft development with more facile drug delivery. We sought to examine the effect of zoledronate on TEVG neotissue formation and its potential application for mitigating TEVG stenosis. Thus, mice implanted with TEVGs received zoledronate or no treatment and were monitored by serial ultrasound for graft dilation and stenosis. After two weeks, TEVGs were explanted for histological examination. The overall graft area and remaining graft material (polyglycolic-acid) were higher in the zoledronate treatment group. These effects were associated with a corresponding decrease in macrophage infiltration. In addition, zoledronate affected the deposition of collagen in TEVGs, specifically, total and mature collagen. These differences may be, in part, explained by a depletion of leukocytes within the bone marrow that subsequently led to a decrease in the number of tissue-infiltrating macrophages. TEVGs from zoledronate-treated mice demonstrated a significantly greater degree of smooth muscle cell presence. There was no statistical difference in graft patency between treatment and control groups. While zoledronate led to a decrease in the number of macrophages in the TEVGs, the severity of stenosis appears to have increased significantly. Zoledronate treatment demonstrates that the process of smooth muscle cell-mediated neointimal hyperplasia may occur separately from a macrophage-mediated mechanism.


Subject(s)
Blood Vessel Prosthesis/statistics & numerical data , Neointima/therapy , Tissue Engineering/methods , Vascular Grafting/methods , Zoledronic Acid/pharmacology , Animals , Bone Density Conservation Agents/pharmacology , Female , Mice , Mice, Inbred C57BL , Neointima/pathology , Tissue Scaffolds/chemistry
7.
J Hand Surg Am ; 46(7): 620.e1-620.e6, 2021 07.
Article in English | MEDLINE | ID: mdl-33485715

ABSTRACT

PURPOSE: The most common method of total wrist arthrodesis is dorsal compression plating, which can require revision for soft tissue or tendon irritation. A locked intramedullary system was developed to reduce this complication. The goal of this study was to investigate the complication rate of total wrist arthrodesis using this system in our center. METHODS: A retrospective chart review of all patients undergoing intramedullary wrist arthrodesis from January 2016 to February 2018 was performed. RESULTS: Nine wrist arthrodeses were performed with locked intramedullary wrist fusion in 5 women and 4 men. The indications for fusion included posttraumatic arthritis in 7 and inflammatory arthritis in 2. Two patients underwent primary arthrodesis and 7 had revision from prior partial wrist fusions. Local bone graft at the radiocarpal joint was used in all cases. The mean follow-up was 27 weeks. Radiocarpal fusion was achieved in 8 patients after the initial procedure and in the ninth patient after revision. There were 6 complications in 4 patients with revision reoperation required in 3. The complications were metacarpal locking screw migration in 3, metacarpal fracture in 1, radiocarpal nonunion in 1, and symptomatic middle finger carpometacarpal nonunion in 1. The revision surgeries include distal screw removal in 1, distal screw removal with replacement in 1, and bone grafting in the radiocarpal nonunion. CONCLUSIONS: Use of the locked intramedullary wrist fusion system yields high fusion rates. However, based on the high complication rate, particularly from distal screw migration, and the high revision rate in this series, we recommend caution with the use of this system. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic V.


Subject(s)
Arthritis , Wrist , Arthritis/etiology , Arthritis/surgery , Arthrodesis/adverse effects , Female , Humans , Male , Retrospective Studies , Wrist Joint/diagnostic imaging , Wrist Joint/surgery
8.
Tissue Eng Part A ; 27(9-10): 593-603, 2021 05.
Article in English | MEDLINE | ID: mdl-32854586

ABSTRACT

Wall stress is often lower in tissue-engineered constructs than in comparable native tissues due to the use of stiff polymeric materials having thicker walls. In this work, we sought to design a murine arterial graft having a more favorable local mechanical environment for the infiltrating cells; we used electrospinning to enclose a compliant inner core of poly(glycerol sebacate) with a stiffer sheath of poly(caprolactone) to reduce the potential for rupture. Two scaffolds were designed that differed in the thickness of the core as previous computational simulations found that circumferential wall stresses could be increased in the core toward native values by increasing the ratio of the core:sheath. Our modified electrospinning protocols reduced swelling of the core upon implantation and eliminated residual stresses in the sheath, both of which had contributed to the occlusion of implanted grafts during pilot studies. For both designs, a subset of implanted grafts occluded due to thrombosis or ruptured due to suspected point defects in the sheath. However, there were design-based differences in collagen content and mechanical behavior during early remodeling of the patent samples, with the thinner-core scaffolds having more collagen and a stiffer behavior after 12 weeks of implantation than the thicker-core scaffolds. By 24 weeks, the thicker-core scaffolds also became stiff, with similar amounts of collagen but increased smooth muscle cell and elastin content. These data suggest that increasing wall stress toward native values may provide a more favorable environment for normal arterial constituents to form despite the overall stiffness of the construct remaining elevated due to the absolute increase in load-bearing constituents.


Subject(s)
Tissue Engineering , Tissue Scaffolds , Animals , Arteries , Blood Vessel Prosthesis , Collagen , Elastin , Mice , Polyesters
9.
Adv Healthc Mater ; 9(24): e2001094, 2020 12.
Article in English | MEDLINE | ID: mdl-33073543

ABSTRACT

Tissue engineered vascular grafts (TEVGs) are a promising technology, but are hindered by occlusion. Seeding with bone-marrow derived mononuclear cells (BM-MNCs) mitigates occlusion, yet the precise mechanism remains unclear. Seeded cells disappear quickly and potentially mediate an anti-inflammatory effect through paracrine signaling. Here, a series of reciprocal genetic TEVG implantations plus recombinant protein treatment is reported to investigate what role interleukin-10, an anti-inflammatory cytokine, plays from both host and seeded cells. TEVGs seeded with BM-MNCs from wild-type and IL-10 KO mice, plus unseeded grafts, are implanted into wild-type and IL-10 KO mice. Wild-type mice with unseeded grafts also receive recombinant IL-10. Serial ultrasound evaluates occlusion and TEVGs are harvested at 14 d for immunohistochemical analysis. TEVGs in IL-10 KO mice have significantly higher occlusion incidence compared to wild-type mice attributed to acute (<3 d) thrombosis. Cell seeding rescues TEVGs in IL-10 KO mice comparable to wild-type patency. IL-10 from the host and seeded cells do not significantly influence graft inflammation and macrophage phenotype, yet IL-10 treatment shows interesting biologic effects including decreasing cell proliferation and increasing M2 macrophage polarization. IL-10 from the host is critical for preventing TEVG thrombosis and seeded BM-MNCs exert a significant anti-thrombotic effect in IL-10 KO mice.


Subject(s)
Blood Vessel Prosthesis , Thrombosis , Animals , Interleukin-10/genetics , Mice , Thrombosis/prevention & control , Tissue Engineering
10.
Metabolites ; 10(10)2020 Oct 08.
Article in English | MEDLINE | ID: mdl-33050077

ABSTRACT

Understanding the metabolic processes in energy metabolism, particularly during fasted exercise, is a growing area of research. Previous work has focused on measuring metabolites pre and post exercise. This can provide information about the final state of energy metabolism in the participants, but it does not show how these processes vary during the exercise and any subsequent post-exercise period. To address this, the work described here took fasted participants and subjected them to an exercise and rest protocol under laboratory settings, which allowed for breath and blood sampling both pre, during and post exercise. Analysis of the data produced from both the physiological measurements and the untargeted metabolomics measurements showed clear switching between glycolytic and ketolytic metabolism, with the liquid chromatography-mass spectrometry (LC-MS) data showing the separate stages of ketolytic metabolism, notably the transport, release and breakdown of long chain fatty acids. Several signals, putatively identified as short peptides, were observed to change in a pattern similar to that of the ketolytic metabolites. This work highlights the power of untargeted metabolomic methods as an investigative tool for exercise science, both to follow known processes in a more complete way and discover possible novel biomarkers.

11.
Metabolites ; 10(6)2020 Jun 10.
Article in English | MEDLINE | ID: mdl-32531990

ABSTRACT

Changes in the plasma metabolic profile were characterised in newly diagnosed rheumatoid arthritis (RA) patients upon commencement of conventional disease-modifying anti-rheumatic drug (cDMARD) therapy. Plasma samples collected in an early RA randomised strategy study (NCT00920478) that compared clinical (DAS) disease activity assessment with musculoskeletal ultrasound assessment (MSUS) to drive treatment decisions were subjected to untargeted metabolomic analysis. Metabolic profiles were collected at pre- and three months post-commencement of nonbiologic cDMARD. Metabolites that changed in association with changes in the DAS44 score were identified at the three-month timepoint. A total of nine metabolites exhibited a clear correlation with a reduction in DAS44 score following cDMARD commencement, particularly itaconate, its derived anhydride and a derivative of itaconate CoA. Increasing itaconate correlated with improved DAS44 score and decreasing levels of C-reactive protein (CRP). cDMARD treatment effects invoke consistent changes in plasma detectable metabolites, that in turn implicate clinical disease activity with macrophages. Such changes inform RA pathogenesis and reveal for the first time a link between itaconate production and resolution of inflammatory disease in humans. Quantitative metabolic biomarker-based tests of clinical change in state are feasible and should be developed around the itaconate pathway.

12.
Sci Transl Med ; 12(537)2020 04 01.
Article in English | MEDLINE | ID: mdl-32238576

ABSTRACT

We developed a tissue-engineered vascular graft (TEVG) for use in children and present results of a U.S. Food and Drug Administration (FDA)-approved clinical trial evaluating this graft in patients with single-ventricle cardiac anomalies. The TEVG was used as a Fontan conduit to connect the inferior vena cava and pulmonary artery, but a high incidence of graft narrowing manifested within the first 6 months, which was treated successfully with angioplasty. To elucidate mechanisms underlying this early stenosis, we used a data-informed, computational model to perform in silico parametric studies of TEVG development. The simulations predicted early stenosis as observed in our clinical trial but suggested further that such narrowing could reverse spontaneously through an inflammation-driven, mechano-mediated mechanism. We tested this unexpected, model-generated hypothesis by implanting TEVGs in an ovine inferior vena cava interposition graft model, which confirmed the prediction that TEVG stenosis resolved spontaneously and was typically well tolerated. These findings have important implications for our translational research because they suggest that angioplasty may be safely avoided in patients with asymptomatic early stenosis, although there will remain a need for appropriate medical monitoring. The simulations further predicted that the degree of reversible narrowing can be mitigated by altering the scaffold design to attenuate early inflammation and increase mechano-sensing by the synthetic cells, thus suggesting a new paradigm for optimizing next-generation TEVGs. We submit that there is considerable translational advantage to combined computational-experimental studies when designing cutting-edge technologies and their clinical management.


Subject(s)
Blood Vessel Prosthesis , Constriction, Pathologic , Tissue Engineering , Animals , Child , Constriction, Pathologic/therapy , Humans , Sheep , United States
13.
J Tissue Eng Regen Med ; 14(2): 203-214, 2020 02.
Article in English | MEDLINE | ID: mdl-31756767

ABSTRACT

Nanofiber vascular grafts have been shown to create neovessels made of autologous tissue, by in vivo scaffold biodegradation over time. However, many studies on graft materials and biodegradation have been conducted in vitro or in small animal models, instead of large animal models, which demonstrate different degradation profiles. In this study, we compared the degradation profiles of nanofiber vascular grafts in a rat model and a sheep model, while controlling for the type of graft material, the duration of implantation, fabrication method, type of circulation (arterial/venous), and type of surgery (interposition graft). We found that there was significantly less remaining scaffold (i.e., faster degradation) in nanofiber vascular grafts implanted in the sheep model compared with the rat model, in both the arterial and the venous circulations, at 6 months postimplantation. In addition, there was more extracellular matrix deposition, more elastin formation, more mature collagen, and no calcification in the sheep model compared with the rat model. In conclusion, studies comparing degradation of vascular grafts in large and small animal models remain limited. For clinical translation of nanofiber vascular grafts, it is important to understand these differences.


Subject(s)
Nanofibers/chemistry , Nanotechnology/methods , Tissue Scaffolds , Vascular Grafting , Animals , Bioprosthesis , Blood Vessel Prosthesis , Disease Models, Animal , Dogs , In Vitro Techniques , Mice , Models, Animal , Polyesters , Rabbits , Rats , Retrospective Studies , Sheep , Tensile Strength , Tissue Engineering/methods
14.
Regen Med ; 14(7): 627-637, 2019 07.
Article in English | MEDLINE | ID: mdl-31342857

ABSTRACT

Aim: This study evaluates scaffold degradation and neotissue formation as a function of sealant polymer composition in tissue-engineered vascular grafts (TEVGs). Materials & methods: Scaffolds fabricated from polyglycolic acid core and sealant composed of polycaprolactone (PCL), poly-L-lactic-acid (PLLA) or 50:50 copolymer poly(ε-caprolactone-co-L-lactide) (PCLA) were analyzed in vitro using accelerated degradation and scanning electron microscopy, and in vivo following implantation in a murine inferior vena cava interposition model. Results:In vitro and in vivo characterization revealed statistically greater degradation of PCLA compared with both PCL and PLLA scaffolds, with similar neotissue formation across all groups. The wall thickness of PLLA TEVGs was statistically greater than PCL TEVGs at 2 weeks postimplant. Conclusion: Results of this study can be used to inform the rational design of future TEVGs.


Subject(s)
Absorbable Implants , Blood Vessel Prosthesis , Materials Testing , Polyesters/chemistry , Tissue Scaffolds/chemistry , Animals , Female , Mice
15.
Acta Biomater ; 94: 183-194, 2019 08.
Article in English | MEDLINE | ID: mdl-31200116

ABSTRACT

Electrospinning is commonly used to generate polymeric scaffolds for tissue engineering. Using this approach, we developed a small-diameter tissue engineered vascular graft (TEVG) composed of poly-ε-caprolactone-co-l-lactic acid (PCLA) fibers and longitudinally assessed its performance within both the venous and arterial circulations of immunodeficient (SCID/bg) mice. Based on in vitro analysis demonstrating complete loss of graft strength by 12 weeks, we evaluated neovessel formation in vivo over 6-, 12- and 24-week periods. Mid-term observations indicated physiologic graft function, characterized by 100% patency and luminal matching with adjoining native vessel in both the venous and arterial circulations. An active and robust remodeling process was characterized by a confluent endothelial cell monolayer, macrophage infiltrate, and extracellular matrix deposition and remodeling. Long-term follow-up of venous TEVGs at 24 weeks revealed viable neovessel formation beyond graft degradation when implanted in this high flow, low-pressure environment. Arterial TEVGs experienced catastrophic graft failure due to aneurysmal dilatation and rupture after 14 weeks. Scaffold parameters such as porosity, fiber diameter, and degradation rate informed a previously described computational model of vascular growth and remodeling, and simulations predicted the gross differential performance of the venous and arterial TEVGs over the 24-week time course. Taken together, these results highlight the requirement for in vivo implantation studies to extend past the critical time period of polymer degradation, the importance of differential neotissue deposition relative to the mechanical (pressure) environment, and further support the utility of predictive modeling in the design, use, and evaluation of TEVGs in vivo. STATEMENT OF SIGNIFICANCE: Herein, we apply a biodegradable electrospun vascular graft to the arterial and venous circulations of the mouse and follow recipients beyond the point of polymer degradation. While venous implants formed viable neovessels, arterial grafts experienced catastrophic rupture due to aneurysmal dilation. We then inform a previously developed computational model of tissue engineered vascular graft growth and remodeling with parameters specific to the electrospun scaffolds utilized in this study. Remarkably, model simulations predict the differential performance of the venous and arterial constructs over 24 weeks. We conclude that computational simulations should inform the rational selection of scaffold parameters to fabricate tissue engineered vascular grafts that must be followed in vivo over time courses extending beyond polymer degradation.


Subject(s)
Arteries/physiology , Blood Vessel Prosthesis , Tissue Engineering/methods , Veins/physiology , Absorbable Implants , Aneurysm/etiology , Animals , Biocompatible Materials/chemistry , Computer Simulation , Female , Mice , Mice, SCID , Microscopy, Electron, Scanning , Reproducibility of Results , Rupture
16.
Regen Med ; 14(5): 389-408, 2019 05.
Article in English | MEDLINE | ID: mdl-31180275

ABSTRACT

Aim: To characterize early events in neotissue formation during the first 2 weeks after vascular scaffold implantation. Materials & methods: Biodegradable polymeric scaffolds were implanted as abdominal inferior vena cava interposition grafts in wild-type mice. Results: All scaffolds explanted at day 1 contained a platelet-rich mural thrombus. Within the first few days, the majority of cell infiltration appeared to be from myeloid cells at the peritoneal surface with modest infiltration along the lumen. Host reaction to the graft was distinct between the scaffold and mural thrombus; the scaffold stimulated an escalating foreign body reaction, whereas the thrombus was quickly remodeled into collagen-rich neotissue. Conclusion: Mural thrombi remodel into neotissue that persistently occludes the lumen of vascular grafts.


Subject(s)
Absorbable Implants , Bioprosthesis , Blood Vessel Prosthesis , Neointima , Animals , Female , Mice , Neointima/metabolism , Neointima/pathology , Sheep , Time Factors
17.
Otolaryngol Head Neck Surg ; 161(3): 458-467, 2019 09.
Article in English | MEDLINE | ID: mdl-31035858

ABSTRACT

OBJECTIVES: Humans receiving tissue-engineered tracheal grafts have experienced poor outcomes ultimately resulting in death or the need for graft explantation. We assessed the performance of the synthetic scaffolds used in humans with an ovine model of orthotopic tracheal replacement, applying standard postsurgical surveillance and interventions to define the factors that contributed to the complications seen at the bedside. STUDY DESIGN: Large animal model. SETTING: Pediatric academic research institute. SUBJECTS AND METHODS: Human scaffolds were manufactured with an electrospun blend of polyethylene terephthalate and polyurethane reinforced with polycarbonate rings. They were seeded with autologous bone marrow-derived mononuclear cells and implanted in sheep. Animals were evaluated with routine bronchoscopy and fluoroscopy. Endoscopic dilation and stenting were performed to manage graft stenosis for up to a 4-month time point. Grafts and adjacent native airway were sectioned and evaluated with histology and immunohistochemistry. RESULTS: All animals had signs of graft stenosis. Three of 5 animals (60%) designated for long-term surveillance survived until the 4-month time point. Graft dilation and stent placement resolved respiratory symptoms and prolonged survival. Necropsy demonstrated evidence of infection and graft encapsulation. Granulation tissue with signs of neovascularization was seen at the anastomoses, but epithelialization was never observed. Acute and chronic inflammation of the native airway epithelium was observed at all time points. Architectural changes of the scaffold included posterior wall infolding and scaffold delamination. CONCLUSIONS: In our ovine model, clinically applied synthetic tissue-engineered tracheas demonstrated infectious, inflammatory, and mechanical failures with a lack of epithelialization and neovascularization.


Subject(s)
Tissue Engineering , Tissue Scaffolds , Trachea/surgery , Animals , Humans , Polyethylene Terephthalates , Polyurethanes , Postoperative Complications/epidemiology , Prosthesis Design , Sheep , Tissue Engineering/methods , Treatment Outcome
18.
Ann Otol Rhinol Laryngol ; 128(5): 391-400, 2019 May.
Article in English | MEDLINE | ID: mdl-30700095

ABSTRACT

OBJECTIVES: The clinical experience with tissue-engineered tracheal grafts (TETGs) has been fraught with graft stenosis and delayed epithelialization. A mouse model of orthotopic replacement that recapitulates the clinical findings would facilitate the study of the cellular and molecular mechanisms underlying graft stenosis. METHODS: Electrospun nanofiber tracheal scaffolds were created using nonresorbable (polyethylene terephthalate + polyurethane) and co-electrospun resorbable (polylactide-co-caprolactone/polyglycolic acid) polymers (n = 10/group). Biomechanical testing was performed to compare load displacement of nanofiber scaffolds to native mouse tracheas. Mice underwent orthotopic tracheal replacement with syngeneic grafts (n = 5) and nonresorbable (n = 10) and resorbable (n = 10) scaffolds. Tissue at the anastomosis was evaluated using hematoxylin and eosin (H&E), K5+ basal cells were evaluated with the help of immunofluorescence testing, and cellular infiltration of the scaffold was quantified. Micro computed tomography was performed to assess graft patency and correlate radiographic and histologic findings with respiratory symptoms. RESULTS: Synthetic scaffolds were supraphysiologic in compression tests compared to native mouse trachea ( P < .0001). Nonresorbable scaffolds were stiffer than resorbable scaffolds ( P = .0004). Eighty percent of syngeneic recipients survived to the study endpoint of 60 days postoperatively. Mean survival with nonresorbable scaffolds was 11.40 ± 7.31 days and 6.70 ± 3.95 days with resorbable scaffolds ( P = .095). Stenosis manifested with tissue overgrowth in nonresorbable scaffolds and malacia in resorbable scaffolds. Quantification of scaffold cellular infiltration correlated with length of survival in resorbable scaffolds (R2 = 0.95, P = .0051). Micro computed tomography demonstrated the development of graft stenosis at the distal anastomosis on day 5 and progressed until euthanasia was performed on day 11. CONCLUSION: Graft stenosis seen in orthotopic tracheal replacement with synthetic tracheal scaffolds can be modeled in mice. The wide array of lineage tracing and transgenic mouse models available will permit future investigation of the cellular and molecular mechanisms underlying TETG stenosis.


Subject(s)
Nanofibers , Tissue Scaffolds , Trachea/surgery , Absorbable Implants , Anastomosis, Surgical , Animals , Biomechanical Phenomena , Caproates , Constriction, Pathologic/pathology , Lactones , Mice, Inbred C57BL , Models, Animal , Polyesters , Polyethylene Terephthalates , Polyglycolic Acid , Polyurethanes , X-Ray Microtomography
19.
Int J Pediatr Otorhinolaryngol ; 116: 65-69, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30554710

ABSTRACT

BACKGROUND: Endoscopic airway measurement (EAM) combines optical endoscopic instruments with open source image processing to accurately obtain airway dimensions. Preclinical models have demonstrated EAM as an accurate technique of airway measurement with the added advantage of characterizing multilevel stenosis, non-circular lesions, and distal obstruction. The aim of this prospective clinical study was to compare EAM to airway measurements obtained from endotracheal tube approximation (ETTA) during pediatric aerodigestive evaluation and to evaluate reproducibility of EAM across practitioners. METHODS: Thirty-seven pediatric patients undergoing routine microlaryngoscopy and bronchoscopy at a single tertiary care children's hospital were prospectively recruited. Patients undergoing emergent procedures were excluded. Two blinded reviewers performed airway measurements using ImageJ (NIH) as previously described and average values were compared to ETTA measurements. Additional EAMs were obtained from an ex vivo airway model by 28 separate clinicians and were analyzed by the same reviewers to evaluate reproducibility. RESULTS: EAM and ETTA measurements were themselves significantly different (p = 0.0003); however, the average absolute difference between the two methods was small (Mean: 0.5 mm, 95%CI: -2.6-1.6 mm). There were notable differences between raters such that estimates of raters with more experience were more similar to ETTA. Despite observed differences between EAM and ETTA, endoscopic airway measurement was highly correlated with ETTA (p = 0.0002, Spearman r = 0.4185), and strong agreement was observed (Bias: -0.4974 ±â€¯1.083 mm, 95% LOA: -2.62-1.625 mm). CONCLUSION: Clinical use of EAM is a valid and precise approach for quantification of airway luminal dimensions. This method may provide advantages over traditional ETTAs for evaluation of asymmetric airway morphology in the pediatric population.


Subject(s)
Bronchoscopy/methods , Intubation, Intratracheal/methods , Laryngoscopy/methods , Respiratory System/surgery , Adolescent , Child , Child, Preschool , Female , Humans , Image Processing, Computer-Assisted , Infant , Male , Prospective Studies , Reproducibility of Results
20.
Tissue Eng Part C Methods ; 24(8): 465-473, 2018 08.
Article in English | MEDLINE | ID: mdl-29978768

ABSTRACT

OBJECTIVES: Tissue-engineered vascular grafts (TEVGs) have demonstrated potential for treating congenital heart disease (CHD); however, quantitative imaging for tracking functional and structural remodeling of TEVGs has not been applied. Therefore, we evaluated the potential of magnetic resonance (MR) imaging for assessing TEVG wall shear stress (WSS) and wall thickness in a large animal model. METHODS: Cell-seeded (n = 3) or unseeded (n = 3) TEVGs were implanted as inferior vena cava interposition grafts in juvenile lambs. Six months following implantation, two-dimensional phase-contrast MR imaging was performed at 3 slice locations (proximal, middle, and distal) to assess normalized WSS (i.e., WSS-to-cross sectional area). T2-weighted MR imaging was performed to assess TEVG wall thickness. Histology was qualitatively assessed, whereas immunohistochemistry was semiquantitatively assessed for smooth muscle cells (αSMA), macrophage lineage cells (CD11b), and matrix metalloproteinase activity (MMP-2 and MMP-9). Picrosirius Red staining was performed to quantify collagen content. RESULTS: TEVG wall thickness was significantly higher for proximal, middle, and distal slices in unseeded versus cell-seeded grafts. Significantly higher WSS values existed for proximal versus distal slice locations for cell-seeded TEVGs, whereas no differences in WSS existed between slices for unseeded TEVGs. Additionally, no differences in WSS existed between cell-seeded and unseeded groups. Both groups demonstrated elastin formation, without vascular calcification. Unseeded TEVGs possessed greater content of smooth muscle cells when compared with cell-seeded TEVGs. No differences in macrophage, MMP activity, or collagen content existed between groups. CONCLUSION: MR imaging allows for in vivo assessment of functional and anatomical characteristics of TEVGs and may provide a nonionizing approach that is clinically translatable to children undergoing treatment for CHD.


Subject(s)
Magnetic Resonance Imaging , Stress, Mechanical , Tissue Engineering/methods , Vascular Grafting , Animals , Collagen/metabolism , Sheep , Tissue Scaffolds/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...