Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
Int J Cardiol ; 417: 132569, 2024 Sep 19.
Article in English | MEDLINE | ID: mdl-39303924

ABSTRACT

BACKGROUND: Raphe-type bicuspid aortic valve (BAV) is a potential hostile scenario in trans-catheter aortic valve replacement (TAVR) due to pronounced calcium burden, possibly associated with tapered valve configuration. Trans-Catheter heart valve (THV) sizing strategy (annular vs. supra-annular) is controversial in this valve subtype. OBJECTIVES: To describe the phenotypical characteristics of severe, tapered, raphe-type, BAV stenosis undergoing TAVR and to explore safety and efficacy of modern-generation THVs, analysing the impact of annular and supra-annular sizing strategies on short- and mid-terms outcomes. METHODS: This is a retrospective, multicenter registry enrolling consecutive stenotic Sievers type 1 BAV treated with TAVR. Study population was divided into tapered and non-tapered configuration according to MSCT analysis. Matched comparison between annular and supra-annular sizing groups was performed in tapered population. RESULTS: From January 2016 to June 2023, 897 patients were enrolled. Of them, 696 patients displayed a tapered configuration. Of those, 510 received a THV according to annular sizing. After propensity score matching 186 matched pairs were selected. Technical success (96.2 % vs 94.1 %, OR 1.61 [0.61-4.24], p = 0.34), 30-day device success (83.6 % in both groups, OR 1.42 [0.78-2.57], p = 0.25) and 30-day early safety (71.8 % vs 70.5 %, OR 1.07 [0.68-1.68], p = 0.78) were similar between the annular and supra-annular sizing groups; a higher post-TAVR gradient was observed in supra-annular group, although it was only 2 mmHg mean. At mid-term follow-up, the rate of clinical efficacy was 84.7 %. CONCLUSIONS: TAVR with modern-generation devices is safe and effective for tapered raphe-type BAV, showing comparable results for annular and supra-annular sizing strategies.

2.
Int J Cardiol ; 412: 132331, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38964556

ABSTRACT

INTRODUCTION: Spontaneous coronary artery dissection (SCAD) is a rare cause of acute myocardial infarction (AMI), which primarily affects young women without traditional cardiovascular risk factors, often presenting as sudden cardiac death. This study aims to investigate the prevalence, characteristics, predictors, and outcomes of cardiac arrest in SCAD patients. METHODS: The DISCO IT/SPA registry, an international retrospective multicenter study, enrolled 375 SCAD patients from 26 centers in Italy and Spain. Patients were categorized based on the presence or absence of cardiac arrest at admission. Data on demographics, clinical presentation, treatment, angiographic findings, and outcomes were collected. Angiograms were independently reviewed, and outcomes included major adverse cardiovascular events (MACE) and in-hospital bleeding. RESULTS: Among 375 SCAD patients, 20 (5.3%) presented with cardiac arrest. Both groups were similar in age, gender distribution, and conventional risk factors, except for a lower prevalence of dyslipidemia in the cardiac arrest group. ST-segment elevation myocardial infarction (STEMI) presentation and angiographic type 2b were independent predictors of cardiac arrest. Revascularization was more frequent in the cardiac arrest group. In-hospital outcomes, except for longer hospitalization, did not differ. On follow-up (average 21 months), MACE rates were similar between groups. CONCLUSIONS: Cardiac arrest is a notable complication in SCAD, mostly presenting with ventricular fibrillation. The prognosis of SCAD patients presenting with cardiac arrest did not differ from those without, reporting a similar rate of events both in-hospital and during long-term follow-up. STEMI presentation and angiographic type 2b were identified as independent predictors of cardiac arrest in SCAD.


Subject(s)
Coronary Vessel Anomalies , Heart Arrest , Registries , Vascular Diseases , Humans , Female , Male , Heart Arrest/epidemiology , Heart Arrest/etiology , Middle Aged , Retrospective Studies , Coronary Vessel Anomalies/epidemiology , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/diagnosis , Vascular Diseases/congenital , Vascular Diseases/epidemiology , Vascular Diseases/diagnosis , Vascular Diseases/complications , Adult , Spain/epidemiology , Aged , Italy/epidemiology , Coronary Angiography/methods , Follow-Up Studies , Risk Factors
3.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Risk Factors , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Treatment Outcome , Aged, 80 and over , Incidence , Time Factors , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/physiopathology , Europe , Risk Assessment , Prosthesis Design , Odds Ratio , Stroke/etiology , Stroke/diagnosis , Heart Failure/physiopathology , Heart Failure/etiology , Heart Failure/diagnosis , Retrospective Studies
6.
Cardiovasc Revasc Med ; 62: 40-47, 2024 May.
Article in English | MEDLINE | ID: mdl-38135568

ABSTRACT

BACKGROUND: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention. METHODS: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest. RESULTS: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4). CONCLUSIONS: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.


Subject(s)
Aortic Valve , Catheterization, Peripheral , Femoral Artery , Punctures , Radiography, Interventional , Registries , Transcatheter Aortic Valve Replacement , Ultrasonography, Interventional , Humans , Femoral Artery/diagnostic imaging , Male , Female , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Aged , Fluoroscopy , Treatment Outcome , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Risk Factors , Radiography, Interventional/adverse effects , Heart Valve Prosthesis , Time Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Prosthesis Design
8.
Int J Cardiol ; 389: 131236, 2023 10 15.
Article in English | MEDLINE | ID: mdl-37532153

ABSTRACT

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Prosthesis Design , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Registries
9.
Int J Cardiol ; 390: 131139, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37355239

ABSTRACT

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Subject(s)
Heart Failure , Heart Transplantation , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Middle Aged , Stroke Volume , Ventricular Function, Left , Time Factors , Heart Transplantation/adverse effects , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Heart Failure/diagnosis , Heart Failure/surgery , Registries , Heart Valve Prosthesis Implantation/methods
12.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Article in English | MEDLINE | ID: mdl-35595675

ABSTRACT

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Hemodynamics , Humans , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Cardiovasc Revasc Med ; 40S: 139-143, 2022 07.
Article in English | MEDLINE | ID: mdl-34362686

ABSTRACT

Preserving coronary artery access is a crucial goal during transcatheter aortic valve replacement (TAVR) procedures, especially in case of self-expandable transcatheter heart valve (SE-THV) implantation. In this light, a proper commissural alignment is needed to avoid the risk of coronary obstruction and to permit easy vessels re-cannulation for diagnostic and interventional purposes. New-generation SE-THVs have been furnished of different markers, able to guide operators to perform a correct commissural alignment. In this case series, we describe key procedural aspects of commissural alignment for the different available SE-THVs, providing a step-by-step tutorial for each device. Lastly, we illustrate a commissural alignment in a contrast-zero TAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
15.
J Cardiovasc Med (Hagerstown) ; 22(12): e37-e40, 2021 Dec 01.
Article in English | MEDLINE | ID: mdl-34482326

ABSTRACT

Arterial vasospasm is a well known cause of ischemia and, if prolonged, of parenchymal infarction. The clinical presentation varies according to the involved arterial district. We describe a rare case, which occurred in a young lady, of recurrent and multisystem vasospasm, resulting in multiple cerebral and myocardial infarctions. Our patient was resistant to medical therapy, requiring stent implantation of the involved vessels.


Subject(s)
Arterial Occlusive Diseases , Blood Vessel Prosthesis Implantation , Brain , Carotid Arteries , Coronary Vasospasm , Vasospasm, Intracranial , Adult , Arterial Occlusive Diseases/diagnosis , Arterial Occlusive Diseases/physiopathology , Arterial Occlusive Diseases/therapy , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/methods , Brain/blood supply , Brain/diagnostic imaging , Calcium Channel Blockers/therapeutic use , Carotid Arteries/diagnostic imaging , Carotid Arteries/physiopathology , Carotid Arteries/surgery , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Vasospasm/diagnostic imaging , Coronary Vasospasm/etiology , Coronary Vasospasm/physiopathology , Drug Resistance , Female , Humans , Magnetic Resonance Imaging/methods , Out-of-Hospital Cardiac Arrest/therapy , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Platelet Aggregation Inhibitors/therapeutic use , Recurrence , Stents , Treatment Outcome , Vasospasm, Intracranial/diagnostic imaging , Vasospasm, Intracranial/etiology , Vasospasm, Intracranial/physiopathology
16.
Eur Heart J ; 42(33): 3161-3171, 2021 08 31.
Article in English | MEDLINE | ID: mdl-34338759

ABSTRACT

AIMS: The role of antiplatelet therapy in patients with spontaneous coronary artery dissection (SCAD) undergoing initial conservative management is still a matter of debate, with theoretical arguments in favour and against its use. The aims of this article are to assess the use of antiplatelet drugs in medically treated SCAD patients and to investigate the relationship between single (SAPT) and dual (DAPT) antiplatelet regimens and 1-year patient outcomes. METHODS AND RESULTS: We investigated the 1-year outcome of patients with SCAD managed with initial conservative treatment included in the DIssezioni Spontanee COronariche (DISCO) multicentre international registry. Patients were divided into two groups according to SAPT or DAPT prescription. Primary endpoint was 12-month incidence of major adverse cardiovascular events (MACE) defined as the composite of all-cause death, non-fatal myocardial infarction (MI), and any unplanned percutaneous coronary intervention (PCI). Out of 314 patients included in the DISCO registry, we investigated 199 patients in whom SCAD was managed conservatively. Most patients were female (89%), presented with acute coronary syndrome (92%) and mean age was 52.3 ± 9.3 years. Sixty-seven (33.7%) were given SAPT whereas 132 (66.3%) with DAPT. Aspirin plus either clopidogrel or ticagrelor were prescribed in 62.9% and 36.4% of DAPT patients, respectively. Overall, a 14.6% MACE rate was observed at 12 months of follow-up. Patients treated with DAPT had a significantly higher MACE rate than those with SAPT [18.9% vs. 6.0% hazard ratios (HR) 2.62; 95% confidence intervals (CI) 1.22-5.61; P = 0.013], driven by an early excess of non-fatal MI or unplanned PCI. At multiple regression analysis, type 2a SCAD (OR: 3.69; 95% CI 1.41-9.61; P = 0.007) and DAPT regimen (OR: 4.54; 95% CI 1.31-14.28; P = 0.016) resulted independently associated with a higher risk of 12-month MACE. CONCLUSIONS: In this European registry, most patients with SCAD undergoing initial conservative management received DAPT. Yet, at 1-year follow-up, DAPT, as compared with SAPT, was independently associated with a higher rate of adverse cardiovascular events (ClinicalTrial.gov id: NCT04415762).


Subject(s)
Acute Coronary Syndrome , Percutaneous Coronary Intervention , Acute Coronary Syndrome/drug therapy , Adult , Coronary Vessels , Dissection , Drug Therapy, Combination , Female , Humans , Middle Aged , Platelet Aggregation Inhibitors/therapeutic use , Registries , Treatment Outcome
17.
G Ital Cardiol (Rome) ; 22(9): 704-711, 2021 Sep.
Article in Italian | MEDLINE | ID: mdl-34463678

ABSTRACT

BACKGROUND: Coronavirus disease 2019 (COVID-19) has shown high morbidity and mortality and the relationship between pulmonary embolism (PE) and COVID-19 is well established in the literature. METHODS: We describe the characteristics of a cohort of COVID-19 patients (EP-COV) hospitalized at our Centre with PE, investigating how COVID-19 may have influenced their outcomes, as compared to patients without COVID-19 hospitalized for PE in the same months of 2020 (EP-2020) and 2019 (EP-2019). RESULTS: EP-COV patients (n=25) were younger (60.5 ± 8.5 vs 71.4 ± 14.5 vs 70.9 ± 11.8 years, p=0.003), more frequently male (76% vs 48% vs 35%, p=0.016), with a lower history of neoplasia (12% vs 47% vs 40%, p=0.028) and more clinically severe (SOFA score 3.4 ± 1.4 vs 2.2 ± 1.4 vs 1 ± 1.1, p<0.001 and PaO2/FiO2 ratio 223.8 ± 75.5 vs 306.5 ± 49.3 vs 311.8 ± 107.5) than EP-2020 (n=17) and EP-2019 patients (n=20). D-dimer and C-reactive protein were higher in EP-COV (p=0.038 e p<0.001, respectively). The rate of concomitant deep vein thrombosis associated with PE did not differ significantly between the three groups. EP-COV patients developed PE more frequently during in-hospital stay than non-COVID-19 patients (p = 0.016). The mortality rate was higher in EP-COV than in EP-2020 and EP-2019 patients (36% vs 0% vs 5%, p=0.019). CONCLUSIONS: In our study, the risk factors for PE in COVID-19 patients seem to differ from the traditional risk factors for venous thromboembolism; EP-COV patients are clinically more severe and display a higher mortality rate than EP-2020 and EP-2019 patients.


Subject(s)
COVID-19 , Pulmonary Embolism , Venous Thromboembolism , Aged , COVID-19/complications , COVID-19/diagnosis , Female , Humans , Italy/epidemiology , Male , Middle Aged , Pulmonary Embolism/epidemiology , Pulmonary Embolism/etiology , SARS-CoV-2
19.
EuroIntervention ; 17(6): 516-524, 2021 Aug 27.
Article in English | MEDLINE | ID: mdl-33650491

ABSTRACT

BACKGROUND: Spontaneous coronary artery dissection (SCAD) is an increasingly diagnosed cause of myocardial infarction. Although different SCAD angiographic classifications exist, their clinical impact remains unknown. AIMS: The aim of this study was to evaluate the relationship between an angiographic classification and the development of adverse clinical events during the follow-up of a large, unselected cohort of patients with SCAD. METHODS: We conducted an observational study of consecutive SCAD patients from 26 centres across Italy and Spain. Cases were classified into five different angiotypes according to the latest classification endorsed by the European Society of Cardiology. The main composite endpoint included all-cause death, non-fatal myocardial infarction (MI), and any unplanned revascularisation. RESULTS: In total, 302 SCAD patients (mean age 51.8±19 years) were followed up for a median of 22 months (IQR 12-48). At 28 days, the composite outcome was higher for the angiotypes with a circumscribed contained intramural haematoma (2A and 3): 20.0% vs 5.4%, p<0.001 (non-fatal MI: 11.0% vs 3.5%, p=0.009; unplanned revascularisation: 11.0% vs 2.5%, p<0.001). This was sustained during follow-up (24.5% vs 9.9%, p=0.001). There were no differences in mortality (0.3% overall). The presence of an angiotype 2A or 3 was an independent predictor of a higher incidence of the composite outcome (adjusted HR 2.44, CI: 1.24-4.80, p=0.010). CONCLUSIONS: The SCAD angiographic classification correlates with outcome. Those presenting with an angiographically circumscribed contained intramural haematoma (angiotypes 2A and 3) showed an increased risk of short-term adverse clinical events that was maintained during follow-up.


Subject(s)
Coronary Vessel Anomalies , Vascular Diseases , Adult , Aged , Coronary Angiography , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/epidemiology , Coronary Vessel Anomalies/surgery , Dissection , Humans , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL