Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 93(32): 11259-11267, 2021 08 17.
Article in English | MEDLINE | ID: mdl-34347442

ABSTRACT

The Virus BioResistor (VBR) is a biosensor capable of rapid and sensitive detection of small protein disease markers using a simple dip-and-read modality. For example, the bladder cancer-associated protein DJ-1 (22 kDa) can be detected in human urine within 1.0 min with a limit of detection (LOD) of 10 pM. The VBR uses engineered virus particles as receptors to recognize and selectively bind the protein of interest. These virus particles are entrained in a conductive poly(3,4-ethylenedioxythiophene) or PEDOT channel. The electrical impedance of the channel increases when the target protein is bound by the virus particles. But VBRs exhibit a sensitivity that is inversely related to the molecular weight of the protein target. Thus, large proteins, such as IgG antibodies (150 kDa), can be undetectable even at high concentrations. We demonstrate that the electrochemical overoxidation of the VBR's PEDOT channel increases its electrical impedance, conferring enhanced sensitivity for both small and large proteins. Overoxidation makes possible the detection of two antibodies, undetectable at a normal VBR, with a limit of detection of 40 ng/mL (250 pM), and a dynamic range for quantitation extending to 600 ng/mL.


Subject(s)
Biosensing Techniques , Bridged Bicyclo Compounds, Heterocyclic , Humans , Immunoglobulin G , Limit of Detection , Polymers
2.
Acc Chem Res ; 53(10): 2384-2394, 2020 10 20.
Article in English | MEDLINE | ID: mdl-33001632

ABSTRACT

The 2018 Nobel Prize in Chemistry recognized in vitro evolution, including the development by George Smith and Gregory Winter of phage display, a technology for engineering the functional capabilities of antibodies into viruses. Such bacteriophages solve inherent problems with antibodies, including their high cost, thermal lability, and propensity to aggregate. While phage display accelerated the discovery of peptide and protein motifs for recognition and binding to proteins in a variety of applications, the development of biosensors using intact phage particles was largely unexplored in the early 2000s. Virus particles, 16.5 MDa in size and assembled from thousands of proteins, could not simply be substituted for antibodies in any existing biosensor architectures.Incorporating viruses into biosensors required us to answer several questions: What process will allow the incorporation of viruses into a functional bioaffinity layer? How can the binding of a protein disease marker to a virus particle be electrically transduced to produce a signal? Will the variable salt concentration of a bodily fluid interfere with electrical transduction? A completely new biosensor architecture and a new scheme for electrical transduction of the binding of molecules to viruses were required.This Account describes the highlights of a research program launched in 2006 that answered these questions. These efforts culminated in 2018 in the invention of a biosensor specifically designed to interface with virus particles: the Virus BioResistor (VBR). The VBR is a resistor consisting of a conductive polymer matrix in which M13 virus particles are entrained. The electrical impedance of this resistor, measured across 4 orders of magnitude in frequency, simultaneously measures the concentration of a target protein and the ionic conductivity of the medium in which the resistor is immersed. Large signal amplitudes coupled with the inherent simplicity of the VBR sensor design result in high signal-to-noise ratio (S/N > 100) and excellent sensor-to-sensor reproducibility. Using this new device, we have measured the urinary bladder cancer biomarker nucleic acid deglycase (DJ-1) in urine samples. This optimized VBR is characterized by extremely low sensor-to-sensor coefficients of variation in the range of 3-7% across the DJ-1 binding curve down to a limit of quantitation of 30 pM, encompassing 4 orders of magnitude in concentration.


Subject(s)
Bacteriophage M13/isolation & purification , Biosensing Techniques/methods , Antibodies/immunology , Bacteriophage M13/chemistry , Bacteriophage M13/immunology , Bacteriophage M13/metabolism , Biomarkers, Tumor/urine , Biosensing Techniques/instrumentation , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Electrodes , Humans , Limit of Detection , Nanowires/chemistry , Neoplasms/diagnosis , Peptide Library , Polymers/chemistry , Protein Deglycase DJ-1/urine , Quartz Crystal Microbalance Techniques , Reproducibility of Results , Signal-To-Noise Ratio
4.
Anal Chem ; 92(9): 6654-6666, 2020 05 05.
Article in English | MEDLINE | ID: mdl-32252524

ABSTRACT

DJ-1, a 20.7 kDa protein, is overexpressed in people who have bladder cancer (BC). Its elevated concentration in urine allows it to serve as a marker for BC. However, no biosensor for the detection of DJ-1 has been demonstrated. Here, we describe a virus bioresistor (VBR) capable of detecting DJ-1 in urine at a concentration of 10 pM in 1 min. The VBR consists of a pair of millimeter-scale gold electrodes that measure the electrical impedance of an ultrathin (≈ 150-200 nm), two-layer polymeric channel. The top layer of this channel (90-105 nm in thickness) consists of an electrodeposited virus-PEDOT (PEDOT is poly(3,4-ethylenedioxythiophene)) composite containing embedded M13 virus particles that are engineered to recognize and bind to the target protein of interest, DJ-1. The bottom layer consists of spin-coated PEDOT-PSS (poly(styrenesulfonate)). Together, these two layers constitute a current divider. We demonstrate here that reducing the thickness of the bottom PEDOT-PSS layer increases its resistance and concentrates the resistance drop of the channel in the top virus-PEDOT layer, thereby increasing the sensitivity of the VBR and enabling the detection of DJ-1. Large signal amplitudes coupled with the inherent simplicity of the VBR sensor design result in high signal-to-noise (S/N > 100) and excellent sensor-to-sensor reproducibility characterized by coefficients of variation in the range of 3-7% across the DJ-1 binding curve down to a concentration of 30 pM, near the 10 pM limit of detection (LOD), encompassing four orders of magnitude in concentration.


Subject(s)
Bacteriophage M13/chemistry , Biomarkers, Tumor/urine , Biosensing Techniques , Protein Deglycase DJ-1/urine , Urinary Bladder Neoplasms/urine , Humans , Time Factors
5.
Nano Lett ; 18(6): 3623-3629, 2018 06 13.
Article in English | MEDLINE | ID: mdl-29718676

ABSTRACT

The virus bioresistor (VBR) is a chemiresistor that directly transfers information from virus particles to an electrical circuit. Specifically, the VBR enables the label-free detection of a target protein that is recognized and bound by filamentous M13 virus particles, each with dimensions of 6 nm ( w) × 1 µm ( l), entrained in an ultrathin (∼250 nm) composite virus-polymer resistor. Signal produced by the specific binding of virus to target molecules is monitored using the electrical impedance of the VBR: The VBR presents a complex impedance that is modeled by an equivalent circuit containing just three circuit elements: a solution resistance ( Rsoln), a channel resistance ( RVBR), and an interfacial capacitance ( CVBR). The value of RVBR, measured across 5 orders of magnitude in frequency, is increased by the specific recognition and binding of a target protein to the virus particles in the resistor, producing a signal Δ RVBR. The VBR concept is demonstrated using a model system in which human serum albumin (HSA, 66 kDa) is detected in a phosphate buffer solution. The VBR cleanly discriminates between a change in the electrical resistance of the buffer, measured by Rsoln, and selective binding of HSA to virus particles, measured by RVBR. The Δ RVBR induced by HSA binding is as high as 200 Ω, contributing to low sensor-to-sensor coefficients-of-variation (<15%) across the entire calibration curve for HSA from 7.5 nM to 900 nM. The response time for the VBR is 3-30 s.


Subject(s)
Bacteriophage M13/chemistry , Biosensing Techniques/instrumentation , Serum Albumin, Human/analysis , Virion/chemistry , Biosensing Techniques/methods , Electric Impedance , Equipment Design , Humans , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL