Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Oper Dent ; 43(5): E243-E252, 2018.
Article in English | MEDLINE | ID: mdl-29953337

ABSTRACT

INTRODUCTION: The aim of the present study was to evaluate the effect of the application of calcium silicate materials (CSMs), after acid etching, on the longevity of the hybrid layer and marginal adaptation of composite restorations. METHODS AND MATERIALS: Eighty human permanent molars received an intrapulpal pressure of 15 cm H2O. Sixty teeth received a mesial proximal slot preparation with the gingival margin extending 1 mm below the cemento-enamel junction. The samples were divided into two groups. Group 1 received restorations using two types of etch-and-rinse adhesives: ethanol based (Single Bond, 3M ESPE, St Paul, MN, USA) and acetone based (Prime & Bond NT, Dentsply, DeTrey GmbH, Germany). In group 2 samples, a commercially available CSM (ProRoot MTA) was allowed to set before grinding and placing into a distilled water solution. This solution was applied on the cavity floor after acid etching. The surface was washed after 30 seconds followed by application of adhesives and restorations as in group 1. The samples were stored in phosphate-buffered saline for six months, maintaining the intrapulpal pressure. An epoxy replica was made, and the marginal adaptation was evaluated using scanning electron microscopy. The percentage of continuous margin (CM) was recorded for each group. Another 20 samples were used for hybrid layer evaluation. The crowns were ground to expose dentin. Intrapulpal pressure was applied. The samples were divided into two groups and restored similar to samples restored for marginal adaptation evaluation. The samples were longitudinally cut in 1-mm slices. The slices were stored under 15 cm of phosphate-buffered saline to simulate the pulpal pressure. After six months, the adhesive interface was evaluated using a scanning electron microscope. Statistical analysis was done with two-way analysis of variance with Holm-Sidak's correction for multiple comparisons. RESULTS: Application of CSMs improved the marginal adaptation values in both adhesive groups. In group 1, there were areas of incomplete penetration of resins along with evidence of partial degradation of resin tags. Samples receiving CSM application after acid etching demonstrated long and regular resin tags with very few signs of degradation. CONCLUSIONS: Application of CSMs after acid etching can be a potential avenue in preserving the resin-dentin bonds.


Subject(s)
Acid Etching, Dental/methods , Calcium Compounds/therapeutic use , Dental Bonding/methods , Dentin/metabolism , Resins, Synthetic/therapeutic use , Silicates/therapeutic use , Dental Marginal Adaptation , Dental Restoration, Permanent/methods , Humans , Microscopy, Electron, Scanning , Molar/surgery
2.
Int Endod J ; 51(1): 5-11, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28370327

ABSTRACT

AIM: To investigate the efficacy of 0.2 mL vs. 0.6 mL of 2% lidocaine when given as a supplementary intraligamentary injection after a failed inferior alveolar nerve block (IANB). METHODOLOGY: Ninety-seven adult patients with symptomatic irreversible pulpits received an IANB and root canal treatment was initiated. Pain during treatment was recorded using a visual analogue scale (Heft-Parker VAS). Patients with unsuccessful anaesthesia (n = 78) randomly received intraligamentary injection of either 0.2 mL or 0.6 mL of 2% lidocaine with 1 : 80 000 epinephrine. Root canal treatment was reinitiated. Success after primary injection or supplementary injection was defined as no or mild pain (HP VAS score ≤54 mm) during access preparation and root canal instrumentation. Heart rate was monitored using a finger pulse oximeter. The anaesthetic success rates were analysed with Pearson chi-square test at 5% significance levels. The heart rate changes were analysed using t-tests. RESULTS: The intraligamentary injections with 0.2 mL solution gave an anaesthetic success rate of 64%, whilst the 0.6 mL was successful in 84% of cases with failed primary IANB. (χ2  = 4.3, P = 0.03). There was no significant effect of the volume of intraligamentary injection on the change in heart rate. CONCLUSIONS: Increasing the volume of intraligamentary injection improved the success rates after a failed primary anaesthetic injection.


Subject(s)
Anesthetics, Local/administration & dosage , Lidocaine/administration & dosage , Nerve Block/adverse effects , Pulpitis/therapy , Adult , Dose-Response Relationship, Drug , Double-Blind Method , Female , Humans , Injections , Male , Prospective Studies , Root Canal Therapy , Treatment Failure , Visual Analog Scale , Young Adult
3.
Int Endod J ; 50(5): 506-511, 2017 May.
Article in English | MEDLINE | ID: mdl-27079789

ABSTRACT

AIM: To evaluate the influence of instrument size and the effect of the electrical resistance of endodontic instruments on the accuracy of three electronic root canal length measurement devices (ERCLMDs). METHODOLOGY: Thirty single-rooted extracted human teeth were divided into three groups (n = 10) on the basis of the ERCLMD used: Root ZX II (J. Morita, Kyoto, Japan); ProPex (Dentsply Maillefer, Ballaigues, Switzerland); and iPex II (NSK, Tochigi, Japan). The electronic working length measurements (EWL) were made with K-files in the sequence sizes 08, 10, 15, 20, 25 and 30. The actual working length (AWL) was calculated by fixing a size 30 K-file in the canal and exposing the apical 5 mm of the root. The minor foramen was identified under an optical microscope, and its distance from the file tip was calculated. The accuracy of the ERCLMDs was evaluated in terms of percentages of accurate measurements (0.0 mm tolerance) and measurements with tolerance limits of ±0.5 mm and ±1.0 mm. The findings were analysed with the McNemar test, Pearson's chi-square tests and two-way analysis of variance. The multiple comparison procedures were carried out using Holm-Sidak method. The maximum electrical resistance tolerated by ERCLMDs was evaluated by connecting commercially available resistors between the file clip and the root canal instrument. The resistance was gradually increased until it started to affect the ERCLMD readings. RESULTS: The ERCLMDs were able to actually locate the minor foramen in 7% of samples. File size did not affect the accuracy of ERCLMDs (P > 0.05). Overall, the ERCLMDs gave 65% readings within a tolerance limit of ±0.5 mm and 90% within a tolerance of ±1.0 mm. The electrical resistance of endodontic files was less than the maximum electrical resistance tolerated by ERCLMDs (0.6-1 Ω vs. 2500-4000 Ω). CONCLUSIONS: The size of the root canal instrument did not affect the accuracy of ERCLMDs in this laboratory study.


Subject(s)
Dental Instruments , Electric Impedance , Equipment Design , Root Canal Preparation/instrumentation , Root Canal Therapy/instrumentation , Humans , Odontometry/instrumentation
4.
Mol Psychiatry ; 21(12): 1717-1725, 2016 12.
Article in English | MEDLINE | ID: mdl-26903268

ABSTRACT

Millions of patients suffer from major depressive disorder (MDD), but many do not respond to selective serotonin reuptake inhibitor (SSRI) therapy. We used a pharmacometabolomics-informed pharmacogenomics research strategy to identify genes associated with metabolites that were related to SSRI response. Specifically, 306 MDD patients were treated with citalopram or escitalopram and blood was drawn at baseline, 4 and 8 weeks for blood drug levels, genome-wide single nucleotide polymorphism (SNP) genotyping and metabolomic analyses. SSRI treatment decreased plasma serotonin concentrations (P<0.0001). Baseline and plasma serotonin concentration changes were associated with clinical outcomes (P<0.05). Therefore, baseline and serotonin concentration changes were used as phenotypes for genome-wide association studies (GWAS). GWAS for baseline plasma serotonin concentrations revealed a genome-wide significant (P=7.84E-09) SNP cluster on chromosome four 5' of TSPAN5 and a cluster across ERICH3 on chromosome one (P=9.28E-08) that were also observed during GWAS for change in serotonin at 4 (P=5.6E-08 and P=7.54E-07, respectively) and 8 weeks (P=1.25E-06 and P=3.99E-07, respectively). The SNPs on chromosome four were expression quantitative trait loci for TSPAN5. Knockdown (KD) and overexpression (OE) of TSPAN5 in a neuroblastoma cell line significantly altered the expression of serotonin pathway genes (TPH1, TPH2, DDC and MAOA). Chromosome one SNPs included two ERICH3 nonsynonymous SNPs that resulted in accelerated proteasome-mediated degradation. In addition, ERICH3 and TSPAN5 KD and OE altered media serotonin concentrations. Application of a pharmacometabolomics-informed pharmacogenomic research strategy, followed by functional validation, indicated that TSPAN5 and ERICH3 are associated with plasma serotonin concentrations and may have a role in SSRI treatment outcomes.


Subject(s)
Depressive Disorder, Major/genetics , Metabolomics/methods , Pharmacogenetics/methods , Adult , Cell Line , Citalopram/therapeutic use , Depressive Disorder, Major/drug therapy , Depressive Disorder, Major/metabolism , Female , Genome-Wide Association Study/methods , Genotype , Humans , Male , Polymorphism, Single Nucleotide/genetics , Serotonin/blood , Selective Serotonin Reuptake Inhibitors/metabolism , Selective Serotonin Reuptake Inhibitors/pharmacology , Tetraspanins/genetics , Tetraspanins/metabolism , Treatment Outcome
5.
Am J Cardiol ; 65(9): 604-8, 1990 Mar 01.
Article in English | MEDLINE | ID: mdl-2309630

ABSTRACT

A decrease in cardiac parasympathetic tone is a recognized finding in patients with ischemic heart disease, sudden cardiac death and heart failure, correlating closely with disease severity and overall survival. To study the clinical potential of vagomimetic intervention, the effect of transdermal scopolamine on fluctuations in heart rate was studied in 32 healthy adult subjects using both time-domain (mean RR interval, standard deviation of the mean RR interval, mean of the differences between consecutive RR intervals) and frequency-domain measures (spectrum analysis of 128 consecutive RR intervals) of heart rate variability. After an exposure of 24 hours, transdermal scopolamine resulted in a significant increase in all indexes tested. The increase was most pronounced in the 0.25-Hz respiratory peak of the RR interval power spectrum, compatible with a strong vagomimetic mode of action of transdermal scopolamine. Results indicate that transdermal scopolamine may have potential merit as a selective vagotonic agent in certain patients with myocardial infarction, heart failure or ventricular arrhythmias.


Subject(s)
Heart Rate/drug effects , Scopolamine/pharmacology , Administration, Cutaneous , Adult , Autonomic Nervous System/drug effects , Autonomic Nervous System/physiology , Electrocardiography , Female , Humans , Male , Scopolamine/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...