Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Eur J Radiol ; 175: 111454, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38598964

ABSTRACT

OBJECTIVES: To evaluate the additional diagnostic benefit of diffusion weighted imaging (DWI) and contrast enhanced (CE) images during MR enterography (MRE) of Crohn's disease. METHODS: Datasets from 73 patients (mean age 32; 40 male) (28 new-diagnosis, 45 relapsed) were read independently by two radiologists selected from a pool of 13. Radiologists interpreted datasets using three sequential sequence blocks: (1) T2 weighted and steady state free precession gradient echo (SSFP) images alone (T2^); (2) T2 weighted and SSFP images with DWI (T2 + DWI^) and; (3) T2 weighted images, SSFP, DWI and post-contrast enhanced (CE) T1 images (T2 + DWI + CE^), documenting presence, location, and activity of small bowel disease. For each sequence block, sensitivity and specificity (readers combined) was calculated against an outcome-based construct reference standard. RESULTS: 59/73 patients had small bowel disease. Per-patient sensitivity for disease detection was essentially identical (80 % [95 % CI 72, 86], 81 % [73,87], and 79 % [71,86] for T2^, T2 + DWI^and T2 + DWI + CE^respectively). Specificity was identical (82 % [64 to 92]). Per patient sensitivity for disease extent was 56 % (47,65), 56 % (47,65) and 52 % (43 to 61) respectively, and specificity was 82 % (64 to 92) for all blocks. Sensitivity for active disease was 97 % (90,99), 97 % (90,99) and 98 % (92,99), and specificity was also comparable between all sequence combination reads. Results were consistent across segments and newly diagnosed/relapse patients. CONCLUSION: There is no additional diagnostic benefit of adding either DWI or CE to T2 FSE and SSFP sequences for evaluating small bowel Crohn's disease, suggesting MRE protocols can be simplified safely.

2.
Aliment Pharmacol Ther ; 59(8): 928-940, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38436124

ABSTRACT

BACKGROUND: Stricturing Crohn's disease (CD) occurs most commonly in the terminal ileum and poses a clinical problem. Cross-sectional imaging modalities such as intestinal ultrasound (IUS), computed tomography enterography (CTE), and magnetic resonance enterography (MRE) allow for assessment of the entire bowel wall and associated peri-enteric findings. Radiologic definitions of strictures have been developed for CTE and MRE; their reliability and responsiveness are being evaluated in index development programs. A comprehensive assessment strategy for strictures using IUS is needed. AIMS: To provide a detailed summary of definitions, diagnosis and monitoring of strictures on IUS as well as technical aspects of image acquisition. METHODS: We searched four databases up to 6 January 2024. Two-stage screening was done in duplicate. We assessed risk of bias using QUADAS-2. RESULTS: There were 56 studies eligible for inclusion. Definitions for strictures on IUS are heterogeneous, but the overall accuracy for diagnosis of strictures is high. The capability of IUS for characterising inflammation versus fibrosis in strictures is not accurate enough to be used in clinical practice or trials. We summarise definitions for improvement of strictures on IUS, and discuss parameters for image acquisition and standardisation. CONCLUSIONS: This systematic review is the first step for a structured program to develop a stricture IUS index for CD.


Subject(s)
Crohn Disease , Intestinal Obstruction , Humans , Crohn Disease/diagnosis , Crohn Disease/diagnostic imaging , Constriction, Pathologic/diagnostic imaging , Constriction, Pathologic/pathology , Reproducibility of Results , Intestines/pathology , Magnetic Resonance Imaging/methods
3.
Eur Radiol ; 34(1): 455-464, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37526665

ABSTRACT

OBJECTIVES: The simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. METHODS: Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). RESULTS: We included 284 patients (median 31.5 years, IQR 23-46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69-86%) and 50% (31-69%) for SUS-CD, and 66% (56-75%) and 68% (47-84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74-86%) and 75% (66-83%) for SUS-CD, and 68% (61-74%) and 85% (76-91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). CONCLUSIONS: Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting. CLINICAL RELEVANCE STATEMENT: When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohn's disease, especially when compared to a magnetic resonance reference standard. KEY POINTS: The simple ultrasound activity score for Crohn's disease and bowel ultrasound score are promising intestinal ultrasound indices of Crohn's disease but to date studied mainly in small settings with few sonographers. Compared to histology and the magnetic resonance reference standard in a multicentre, multireader setting, the sensitivity of simple ultrasound activity score for Crohn's disease is significantly greater than that of bowel ultrasound score. The specificity of simple ultrasound activity score for Crohn's disease was significantly lower than that of bowel ultrasound score compared to the magnetic resonance enterography reference standard. The specificity of both indices was numerically higher when the magnetic resonance enterography reference standard was adopted.


Subject(s)
Crohn Disease , Adult , Humans , Crohn Disease/pathology , Ileum/diagnostic imaging , Ileum/pathology , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Prospective Studies
4.
BMJ Open ; 12(10): e067265, 2022 10 03.
Article in English | MEDLINE | ID: mdl-36192092

ABSTRACT

INTRODUCTION: Crohn's disease (CD) is characterised by discontinuous, relapsing enteric inflammation. Instituting advanced therapies at an early stage to suppress inflammation aims to prevent future complications such as stricturing or penetrating disease, and subsequent surgical resection. Therapeutics are effective but associated with certain side-effects and relatively expensive. There is therefore an urgent need for robust methods to predict which newly diagnosed patients will develop disabling disease, to identify patients who are most likely to benefit from early, advanced therapies. We aim to determine if magnetic resonance enterography (MRE) features at diagnosis improve prediction of disabling CD within 5 years of diagnosis. METHODS AND ANALYSIS: We describe the protocol for a multicentre, non-randomised, single-arm, prospective study of adult patients with newly diagnosed CD. We will use patients already recruited to the METRIC study and extend their clinical follow-up, as well as a separate group of newly diagnosed patients who were not part of the METRIC trial (MRE within 3 months of diagnosis), to ensure an adequate sample size. Follow-up will extend for at least 4 years. The primary outcome is to evaluate the comparative predictive ability of prognostic models incorporating MRE severity scores (Magnetic resonance Enterography Global Score (MEGS), simplified MAgnetic Resonance Index of Activity (sMaRIA) and Lémann Index) versus models using standard characteristics alone to predict disabling CD (modified Beaugerie definition) within 5 years of new diagnosis. ETHICS AND DISSEMINATION: This study protocol achieved National Health Service Research Ethics Committee (NHS REC), London-Hampstead Research Ethics Committee approval (IRAS 217422). Our findings will be disseminated via conference presentations and peer-reviewed publications. TRIAL REGISTRATION NUMBER: ISRCTN76899103.


Subject(s)
Crohn Disease , Adult , Crohn Disease/drug therapy , Humans , Inflammation , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Multicenter Studies as Topic , Prospective Studies , State Medicine
5.
J Crohns Colitis ; 16(10): 1531-1539, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-35481898

ABSTRACT

BACKGROUND AND AIMS: The simplified magnetic resonance enterography [MRE] index of activity [sMARIA], London, and 'extended' London, scoring systems are widely used in Crohn's disease [CD] to assess disease activity, although validation studies have usually been single-centre, retrospective, and/or used few readers. Here, we evaluated these MRE indices within a prospective, multicentre, multireader, diagnostic accuracy trial. METHODS: A subset of participants [newly diagnosed or suspected of relapse] recruited to the METRIC trial with available terminal ileal [TI] biopsies was included. Using pre-specified thresholds, the sensitivity and specificity of sMARIA, London, and 'extended' London scores for active and severe [sMARIA] TI CD were calculated using different thresholds for the histological activity index [HAI]. RESULTS: We studied 111 patients [median age 29 years, interquartile range 21-41, 75 newly diagnosed, 36 suspected relapse] from seven centres, of whom 22 had no active TI CD [HAI = 0], 39 mild [HAI = 1], 13 moderate [HAI = 2], and 37 severe CD activity [HAI = 3]. In total, 26 radiologists prospectively scored MRE datasets as per their usual clinical practice. Sensitivity and specificity for active disease [HAI >0] were 83% [95% confidence interval 74% to 90%] and 41% [23% to 61%] for sMARIA, 76% [67% to 84%] and 64% [43% to 80%] for the London score, and 81% [72% to 88%] and 41% [23% to 61%] for the 'extended' London score, respectively. The sMARIA had 84% [69-92%] sensitivity and 53% [41-64%] specificity for severe CD. CONCLUSIONS: When tested at their proposed cut-offs in a real-world setting, sMARIA, London, and 'extended' London indices achieve high sensitivity for active TI disease against a histological reference standard, but specificity is low.


Subject(s)
Crohn Disease , Adult , Humans , Crohn Disease/pathology , Retrospective Studies , Prospective Studies , Magnetic Resonance Imaging , Recurrence , Reference Standards , Magnetic Resonance Spectroscopy
6.
Eur Radiol ; 32(8): 5075-5085, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35243523

ABSTRACT

OBJECTIVES: To compare the distention quality and patient experience of oral mannitol and polyethylene glycol (PEG) for MRE. METHODS: This study is a retrospective, observational study of a subset of patients enrolled in a multicentre, prospective trial evaluating the diagnostic accuracy of MRE for small bowel Crohn's. Overall and segmental MRE small bowel distention, from 105 patients (64 F, mean age 37) was scored from 0 = poor to 4 = excellent by two experienced observers (68 [65%] mannitol and 37 [35%] PEG). Additionally, 130 patients (77 F, mean age 34) completed a questionnaire rating tolerability of various symptoms immediately and 2 days after MRE (85 [65%] receiving mannitol 45 [35%] receiving PEG). Distension was compared between agents and between those ingesting ≤ 1 L or > 1 L of mannitol using the test of proportions. Tolerability grades were collapsed into "very tolerable," "moderately tolerable," and "not tolerable." RESULTS: Per patient distension quality was similar between agents ("excellent" or "good" in 54% [37/68] versus 46% [17/37]) with mannitol and PEG respectively. Jejunal distension was significantly better with mannitol compared to PEG (40% [27/68] versus 14% [5/37] rated as excellent or good respectively). There was no significant difference according to the volume of mannitol ingested. Symptom tolerability was comparable between agents, although fullness following MRE was graded as "very tolerable" in 27% (12/45) of patients ingesting PEG, verses 44% (37/84) ingesting mannitol, difference 17% (95% CI 0.6 to 34%). CONCLUSION: Mannitol-based solutions and PEG generally achieve comparable distension quality and side effect profiles, although jejunal distension is better quality with mannitol. Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. KEY POINTS: • Mannitol-based and PEG-based oral preparation agents generally achieve comparable distension quality for MRE with the exception of the jejunum which is better distended with mannitol. • Mannitol-based and PEG-based oral preparation agents used for MRE have similar side effect profiles. • Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol.


Subject(s)
Crohn Disease , Drug-Related Side Effects and Adverse Reactions , Adult , Contrast Media/pharmacology , Crohn Disease/diagnostic imaging , Humans , Magnetic Resonance Imaging , Mannitol/pharmacology , Patient Outcome Assessment , Polyethylene Glycols , Prospective Studies , Retrospective Studies
7.
Br J Radiol ; 95(1134): 20210995, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35195444

ABSTRACT

OBJECTIVES: To evaluate interobserver variability for diagnosis of disease presence and extent of small bowel and colonic Crohn's disease using MR enterography (MRE). METHODS: Data from the first 73 consecutive patients (mean age 32, 33F, 28 new diagnosis, 45 suspected relapse) recruited to a multicentre, prospective diagnostic accuracy trial evaluating MRE for small bowel Crohn's disease were each read independently by three (from a pool of 20) radiologists. Radiologists documented presence and segmental location of small bowel Crohn's disease and recorded morphological mural/extramural parameters for involved segments. Per patient percentage agreement for disease presence and extent were calculated against an outcome-based construct reference standard (averaged between pairs of readers). Prevalence-adjusted bias-adjusted κ (PABAK) was calculated. RESULTS: Agreement for small bowel disease presence for new diagnosis/relapsed patients was 68%(κ = 0.36)/ 78% (κ = 0.56) and 43%(κ = 0.14)/ 53% for disease extent (κ = 0.07), respectively. For disease presence, all three radiologists agreed correctly with the reference standard in 41/59 (69%) of patients with small bowel involvement, and in 8/14 (57%) cases of without small bowel disease. Agreement was highest for multisegment disease, greater than 5 cm in length, with mural thickness>6 mm, and increased mural T2 signal. Agreement for colonic disease presence was 61% (κ = 0.21 fair agreement) for new diagnosis/ 60% (κ = 0.20, slight agreement) for relapsed patients. CONCLUSION: There is a reasonable agreement between radiologists for small bowel disease presence using MRE for newly diagnosed Crohn's disease, and patients with suspected relapse, respectively. Agreement is lower for disease extent. ADVANCES IN KNOWLEDGE: There is reasonable agreement between radiologists for small bowel disease presence using MRE for newly diagnosed (68%) Crohn's disease, and patients with suspected relapse (78%). Agreement is lower for disease extent (43% new diagnosis and 53% suspected relapse).


Subject(s)
Crohn Disease , Adult , Clinical Trials as Topic , Crohn Disease/diagnostic imaging , Crohn Disease/pathology , Female , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Male , Multicenter Studies as Topic , Observer Variation , Prospective Studies , Recurrence
8.
Abdom Radiol (NY) ; 46(1): 144-155, 2021 01.
Article in English | MEDLINE | ID: mdl-32564208

ABSTRACT

PURPOSE: To evaluate the utility of mural and extramural sonographic features of Crohn's Disease as potential imaging biomarkers of inflammation and fibrosis against whole-mount histological sections. METHODS: Twelve Crohn's disease patients (Mean age 35(25-69), 7 males) underwent small bowel ultrasound prior to small bowel resection. Two radiologists in consensus graded multiple parameters including mural, mucosal and submucosal thickness, submucosal/mesenteric echogenicity and clarity and mural Doppler signal in 50 selected bowel cross-sections. Matching with histological sampling sites was facilitated via scanning of the resected specimen. A histopathologist scored acute and chronic inflammation, and fibrosis (using histological scoring systems) following analysis of whole mount block sections. The association between sonographic observations and histopathological scores was examined via univariable and multivariable analysis. RESULTS: In univariate analyses, bowel wall thickness (regression co-efficient and 95% CI 0.8 (0.3, 1.3) p = 0.001), mesenteric fat echogenicity (8.7(3.0, 14.5) p = 0.005), submucosal layer thickness (7.4(1.2, 13.5) p = 0.02), submucosal layer clarity (4.4(0.6, 8.2) p = 0.02) and mucosal layer thickness (4.6(1.8, 7.4) p = 0.001) were all significantly associated with acute inflammation. Mesenteric fat echogenicity (674(8.67, 52404) p = 0.009), submucosal layer thickness (79.9(2.16, 2951) p = 0.02) and mucosal layer thickness (13.6(1.54, 121) p = 0.02) were significantly associated with chronic inflammation. Submucosal layer echogenicity (p = 0.03), clarity (25.0(1.76, 356) p = 0.02) and mucosal layer thickness (53.8(3.19, 908) p = 0.006) were significantly associated with fibrosis. In multivariate analyses, wall and mucosal thickness remained significantly associated with acute inflammation (p = 0.02), mesenteric fat echogenicity with chronic inflammation (p = 0.009) and mucosal thickness (p = 0.006) with fibrosis. CONCLUSION: Multiple sonographic parameters are associated with histological phenotypes in Crohn's disease although there is overlap between ultrasonic stigmata of acute inflammation, chronic inflammation and fibrosis.


Subject(s)
Crohn Disease , Adult , Crohn Disease/diagnostic imaging , Crohn Disease/pathology , Fibrosis , Humans , Inflammation/diagnostic imaging , Inflammation/pathology , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Male , Ultrasonography
9.
BMC Med ; 18(1): 346, 2020 11 04.
Article in English | MEDLINE | ID: mdl-33143712

ABSTRACT

BACKGROUND: Tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral ribonucleic acid (RNA) using reverse transcription polymerase chain reaction (RT-PCR) are pivotal to detecting current coronavirus disease (COVID-19) and duration of detectable virus indicating potential for infectivity. METHODS: We conducted an individual participant data (IPD) systematic review of longitudinal studies of RT-PCR test results in symptomatic SARS-CoV-2. We searched PubMed, LitCOVID, medRxiv, and COVID-19 Living Evidence databases. We assessed risk of bias using a QUADAS-2 adaptation. Outcomes were the percentage of positive test results by time and the duration of detectable virus, by anatomical sampling sites. RESULTS: Of 5078 studies screened, we included 32 studies with 1023 SARS-CoV-2 infected participants and 1619 test results, from - 6 to 66 days post-symptom onset and hospitalisation. The highest percentage virus detection was from nasopharyngeal sampling between 0 and 4 days post-symptom onset at 89% (95% confidence interval (CI) 83 to 93) dropping to 54% (95% CI 47 to 61) after 10 to 14 days. On average, duration of detectable virus was longer with lower respiratory tract (LRT) sampling than upper respiratory tract (URT). Duration of faecal and respiratory tract virus detection varied greatly within individual participants. In some participants, virus was still detectable at 46 days post-symptom onset. CONCLUSIONS: RT-PCR misses detection of people with SARS-CoV-2 infection; early sampling minimises false negative diagnoses. Beyond 10 days post-symptom onset, lower RT or faecal testing may be preferred sampling sites. The included studies are open to substantial risk of bias, so the positivity rates are probably overestimated.


Subject(s)
Betacoronavirus/isolation & purification , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Reverse Transcriptase Polymerase Chain Reaction/methods , Reverse Transcriptase Polymerase Chain Reaction/standards , Betacoronavirus/genetics , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Coronavirus Infections/genetics , Humans , Longitudinal Studies , Pandemics , Pneumonia, Viral/genetics , SARS-CoV-2
10.
Abdom Radiol (NY) ; 45(10): 3036-3045, 2020 10.
Article in English | MEDLINE | ID: mdl-32037466

ABSTRACT

PURPOSE: To prospectively evaluate interobserver agreement for small bowel ultrasound (SBUS) in newly diagnosed and relapsing Crohn's disease. METHODS: A subset of patients recruited to a prospective trial comparing the diagnostic accuracy of MR enterography and SBUS underwent a second SBUS performed by one of a pool of six practitioners, who recorded the presence, activity and location of small bowel and colonic disease. Detailed segmental mural and extra-mural observations were also scored. Interobserver variability was expressed as percentage agreement with a construct reference standard, split by patient cohort, grouping disease as present or absent. Prevalence adjusted bias adjusted kappa (PABAK), and simple percentage agreement between practitioners, irrespective of the reference standard, were calculated. RESULTS: Thirty-eight patients (11 new diagnosis, 27 relapse) were recruited from two sites. Overall percentage agreement for small bowel disease presence against the consensus reference was 82% (52-95% (95%CI)), kappa coefficient (κ) 0.64, (substantial agreement) for new diagnosis and 81%, κ 0.63 (substantial agreement) for the relapsing cohort. Agreement for colonic disease presence was 64%, κ 0.27 (fair agreement) in new diagnosis and 78%,κ 0.56 (moderate agreement) in the relapsing cohort. Simple agreement between practitioners was 84% and 87% for small bowel and colonic disease presence respectively. Practitioners agreed on small bowel disease activity in 24/27 (89%) where both identified disease. Kappa agreement for detailed mural observations ranged from κ 0.00 to 1.00. CONCLUSION: There is substantial practitioner agreement for small bowel disease presence in newly diagnosed and relapsing CD patients, supporting wider dissemination of enteric US.


Subject(s)
Crohn Disease , Ultrasonography , Crohn Disease/diagnostic imaging , Humans , Intestine, Small/diagnostic imaging , Magnetic Resonance Imaging , Observer Variation , Prospective Studies
11.
Health Technol Assess ; 23(42): 1-162, 2019 08.
Article in English | MEDLINE | ID: mdl-31432777

ABSTRACT

BACKGROUND: Magnetic resonance enterography and enteric ultrasonography are used to image Crohn's disease patients. Their diagnostic accuracy for presence, extent and activity of enteric Crohn's disease was compared. OBJECTIVE: To compare diagnostic accuracy, observer variability, acceptability, diagnostic impact and cost-effectiveness of magnetic resonance enterography and ultrasonography in newly diagnosed or relapsing Crohn's disease. DESIGN: Prospective multicentre cohort study. SETTING: Eight NHS hospitals. PARTICIPANTS: Consecutive participants aged ≥ 16 years, newly diagnosed with Crohn's disease or with established Crohn's disease and suspected relapse. INTERVENTIONS: Magnetic resonance enterography and ultrasonography. MAIN OUTCOME MEASURES: The primary outcome was per-participant sensitivity difference between magnetic resonance enterography and ultrasonography for small bowel Crohn's disease extent. Secondary outcomes included sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease extent, and sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease presence; identification of active disease; interobserver variation; participant acceptability; diagnostic impact; and cost-effectiveness. RESULTS: Out of the 518 participants assessed, 335 entered the trial, with 51 excluded, giving a final cohort of 284 (133 and 151 in new diagnosis and suspected relapse cohorts, respectively). Across the whole cohort, for small bowel Crohn's disease extent, magnetic resonance enterography sensitivity [80%, 95% confidence interval (CI) 72% to 86%] was significantly greater than ultrasonography sensitivity (70%, 95% CI 62% to 78%), with a 10% difference (95% CI 1% to 18%; p = 0.027). For small bowel Crohn's disease extent, magnetic resonance enterography specificity (95%, 95% CI 85% to 98%) was significantly greater than ultrasonography specificity (81%, 95% CI 64% to 91%), with a 14% difference (95% CI 1% to 27%). For small bowel Crohn's disease presence, magnetic resonance enterography sensitivity (97%, 95% CI 91% to 99%) was significantly greater than ultrasonography sensitivity (92%, 95% CI 84% to 96%), with a 5% difference (95% CI 1% to 9%). For small bowel Crohn's disease presence, magnetic resonance enterography specificity was 96% (95% CI 86% to 99%) and ultrasonography specificity was 84% (95% CI 65% to 94%), with a 12% difference (95% CI 0% to 25%). Test sensitivities for small bowel Crohn's disease presence and extent were similar in the two cohorts. For colonic Crohn's disease presence in newly diagnosed participants, ultrasonography sensitivity (67%, 95% CI 49% to 81%) was significantly greater than magnetic resonance enterography sensitivity (47%, 95% CI 31% to 64%), with a 20% difference (95% CI 1% to 39%). For active small bowel Crohn's disease, magnetic resonance enterography sensitivity (96%, 95% CI 92% to 99%) was significantly greater than ultrasonography sensitivity (90%, 95% CI 82% to 95%), with a 6% difference (95% CI 2% to 11%). There was some disagreement between readers for both tests. A total of 88% of participants rated magnetic resonance enterography as very or fairly acceptable, which is significantly lower than the percentage (99%) of participants who did so for ultrasonography. Therapeutic decisions based on magnetic resonance enterography alone and ultrasonography alone agreed with the final decision in 122 out of 158 (77%) cases and 124 out of 158 (78%) cases, respectively. There were no differences in costs or quality-adjusted life-years between tests. LIMITATIONS: Magnetic resonance enterography and ultrasonography scans were interpreted by practitioners blinded to clinical data (but not participant cohort), which does not reflect use in clinical practice. CONCLUSIONS: Magnetic resonance enterography has higher accuracy for detecting the presence, extent and activity of small bowel Crohn's disease than ultrasonography does. Both tests have variable interobserver agreement and are broadly acceptable to participants, although ultrasonography produces less participant burden. Diagnostic impact and cost-effectiveness are similar. Recommendations for future work include investigation of the comparative utility of magnetic resonance enterography and ultrasonography for treatment response assessment and investigation of non-specific abdominal symptoms to confirm or refute Crohn's disease. TRIAL REGISTRATION: Current Controlled Trials ISRCTN03982913. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 42. See the NIHR Journals Library website for further project information.


Crohn's disease is a waxing and waning lifelong inflammatory condition that affects the colon (large bowel) and small bowel. Treatment relies on accurately determining disease extent and underlying inflammation. Colonoscopy is very good for examining the colon, but it is invasive and, at best, can only visualise a few centimetres of the small bowel, so radiological imaging is very important. Magnetic resonance enterography (a type of magnetic resonance imaging scan) and ultrasonography are both radiological tests commonly performed in the NHS, and it is unclear which method is better. We performed a study to compare the accuracy of magnetic resonance enterography and ultrasonography for determining the extent of Crohn's disease in the bowel of participants newly diagnosed and in those participants with established Crohn's disease but with suspected deterioration. We also investigated how often radiologists agree with each other during test interpretation, the participant experience of undergoing the tests and their cost-effectiveness. We compared the tests in 284 participants (133 newly diagnosed and 151 with suspected deterioration). We found that both tests were accurate for detecting the presence (97% for magnetic resonance enterography and 92% for ultrasonography) and location (80% for magnetic resonance enterography and 70% for ultrasonography) of disease in the small bowel, but magnetic resonance enterography was better than ultrasonography for both (correctly classifying disease extent in 107 more participants for every 1000 participants with Crohn's disease). Magnetic resonance enterography was similarly better than ultrasonography at determining if the bowel was inflamed. The results were similar in newly diagnosed participants and those participants with suspected deterioration. Agreement between radiologists interpreting the same images was, at best, moderate for both tests. A total of 88% of participants tolerated magnetic resonance enterography well or fairly well, which was less than the percentage (99%) of participants who tolerated ultrasonography well or fairly well. Both tests had a similar effect on the treatment decisions made by doctors. Both tests were also similar in their value for money for the NHS.


Subject(s)
Cost-Benefit Analysis , Crohn Disease/diagnostic imaging , Magnetic Resonance Imaging , Ultrasonography , Adolescent , Adult , Female , Humans , Intestine, Small , Male , Middle Aged , Prospective Studies , Recurrence , Sensitivity and Specificity , United Kingdom , Young Adult
12.
Lancet Gastroenterol Hepatol ; 4(7): 529-537, 2019 07.
Article in English | MEDLINE | ID: mdl-31080095

ABSTRACT

BACKGROUND: Whole-body MRI (WB-MRI) could be an alternative to multimodality staging of colorectal cancer, but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in colorectal cancer. METHODS: The Streamline C trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed colorectal cancer. Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or polyp cancer. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs), and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN43958015, and is complete. FINDINGS: Between March 26, 2013, and Aug 19, 2016, 1020 patients were screened for eligibility. 370 patients were recruited, 299 of whom completed the trial; 68 (23%) had metastasis at baseline. Pathway sensitivity was 67% (95% CI 56 to 78) for WB-MRI and 63% (51 to 74) for standard pathways, a difference in sensitivity of 4% (-5 to 13, p=0·51). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (95% [95% CI 92-97]) and standard pathways (93% [90-96], p=0·48). Agreement with the multidisciplinary team's final treatment decision was 96% for WB-MRI and 95% for the standard pathway. Time to complete staging was shorter for WB-MRI (median, 8 days [IQR 6-9]) than for the standard pathway (13 days [11-15]); a 5-day (3-7) difference. WB-MRI required fewer tests (median, one [95% CI 1 to 1]) than did standard pathways (two [2 to 2]), a difference of one (1 to 1). Mean per-patient staging costs were £216 (95% CI 211-221) for WB-MRI and £285 (260-310) for standard pathways. INTERPRETATION: WB-MRI staging pathways have similar accuracy to standard pathways and reduce the number of tests needed, staging time, and cost. FUNDING: UK National Institute for Health Research.


Subject(s)
Colorectal Neoplasms/pathology , Magnetic Resonance Imaging/standards , Whole Body Imaging/standards , Aged , Critical Pathways , Female , Humans , Male , Middle Aged , Neoplasm Metastasis , Neoplasm Staging , Prospective Studies , Reference Standards , Sensitivity and Specificity
13.
Lancet Respir Med ; 7(6): 523-532, 2019 06.
Article in English | MEDLINE | ID: mdl-31080129

ABSTRACT

BACKGROUND: Whole-body magnetic resonance imaging (WB-MRI) could be an alternative to multi-modality staging of non-small-cell lung cancer (NSCLC), but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in NSCLC. METHODS: The Streamline L trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed NSCLC that was potentially radically treatable on diagnostic chest CT (defined as stage IIIb or less). Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or histologies other than NSCLC. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs) and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN50436483, and is complete. FINDINGS: Between Feb 26, 2013, and Sept 5, 2016, 976 patients were screened for eligibility. 353 patients were recruited, 187 of whom completed the trial; 52 (28%) had metastasis at baseline. Pathway sensitivity was 50% (95% CI 37-63) for WB-MRI and 54% (41-67) for standard pathways, a difference of 4% (-7 to 15, p=0·73). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (93% [88-96]) and standard pathways (95% [91-98], p=0·45). Agreement with the multidisciplinary team's final treatment decision was 98% for WB-MRI and 99% for the standard pathway. Time to complete staging was shorter for WB-MRI (13 days [12-14]) than for the standard pathway (19 days [17-21]); a 6-day (4-8) difference. The number of tests required was similar WB-MRI (one [1-1]) and standard pathways (one [1-2]). Mean per-patient costs were £317 (273-361) for WBI-MRI and £620 (574-666) for standard pathways. INTERPRETATION: WB-MRI staging pathways have similar accuracy to standard pathways, and reduce the staging time and costs. FUNDING: UK National Institute for Health Research.


Subject(s)
Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/statistics & numerical data , Neoplasm Metastasis/diagnostic imaging , Whole Body Imaging/statistics & numerical data , Aged , England , Female , Humans , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/statistics & numerical data , Whole Body Imaging/methods
15.
Eur Radiol ; 29(3): 1083-1093, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30128615

ABSTRACT

OBJECTIVES: To compare patient acceptability and burden of magnetic resonance enterography (MRE) and ultrasound (US) to each other, and to other enteric investigations, particularly colonoscopy. METHODS: 159 patients (mean age 38, 94 female) with newly diagnosed or relapsing Crohn's disease, prospectively recruited to a multicentre diagnostic accuracy study comparing MRE and US completed an experience questionnaire on the burden and acceptability of small bowel investigations between December 2013 and September 2016. Acceptability, recovery time, scan burden and willingness to repeat the test were analysed using the Wilcoxon signed rank and McNemar tests; and group differences in scan burden with Mann-Whitney U and Kruskal-Wallis tests. RESULTS: Overall, 128 (88%) patients rated MRE as very or fairly acceptable, lower than US (144, 99%; p < 0.001), but greater than colonoscopy (60, 60%; p < 0.001). MRE recovery time was longer than US (p < 0.001), but shorter than colonoscopy (p < 0.001). Patients were less willing to undergo MRE again than US (127 vs. 133, 91% vs. 99%; p = 0.012), but more willing than for colonoscopy (68, 75%; p = 0.017). MRE generated greater burden than US (p < 0.001), although burden scores were low. Younger age and emotional distress were associated with greater MRE and US burden. Higher MRE discomfort was associated with patient preference for US (p = 0.053). Patients rated test accuracy as more important than scan discomfort. CONCLUSIONS: MRE and US are well tolerated. Although MRE generates greater burden, longer recovery and is less preferred than US, it is more acceptable than colonoscopy. Patients, however, place greater emphasis on diagnostic accuracy than burden. KEY POINTS: • MRE and US are rated as acceptable by most patients and superior to colonoscopy. • MRE generates significantly greater burden and longer recovery times than US, particularly in younger patients and those with high levels of emotional distress. • Most patients prefer the experience of undergoing US than MRE; however, patients rate test accuracy as more importance than scan burden.


Subject(s)
Colonoscopy/methods , Crohn Disease/diagnosis , Intestine, Small/diagnostic imaging , Magnetic Resonance Imaging/methods , Patient Satisfaction , Ultrasonography/methods , Adolescent , Adult , Female , Humans , Male , Middle Aged , Recurrence , Reproducibility of Results , Severity of Illness Index
16.
Radiology ; 289(2): 428-435, 2018 11.
Article in English | MEDLINE | ID: mdl-30129901

ABSTRACT

Purpose To evaluate the accuracy of MRI-quantified small bowel motility for Crohn disease activity against endoscopic and histopathologic reference standards. Materials and Methods For this prospective study, 82 participants (median age, 31 years; range, 16 to 70 years; 42 males [median age, 31 years; range, 17 to 70 years] and 40 females [median age, 31 years; range, 16 to 63 years) underwent colonoscopy and MR enterography within 14 days (from October 2011 to March 2014) at two centers. The Crohn disease endoscopic index of severity (CDEIS), histopathologic activity score (endoscopic biopsy acute histologic inflammatory score [EAIS]), and MR index of activity (MaRIA) were scored in the terminal ileum. Terminal ileal motility was quantified by using an image registration based-motility assessment algorithm (hereafter, Motility). Sensitivity and specificity of Motility (˂0.3 arbitrary units) and MaRIA (≥7 and ≥11) for disease activity (CDEIS ≥4 or EAIS ≥1) were compared by using the McNemar test. Receiver operating characteristic curves were constructed and areas under the curve were compared. Motility was correlated with reference standards by using Spearman rank estimates. Results Terminal ileal Motility was negatively correlated with EAIS (r =-0.61; 95% confidence interval [CI]: 0.7, -0.5) and CDEIS (r = -0.59; 95% CI: 0.7, -0.4). With CDEIS as the standard of reference, Motility had higher sensitivity than did MaRIA (≥11) (93% vs 78%, respectively; P = .03), but lower specificity (61% vs 81%, respectively; P = .04). With EAIS as the standard of reference, Motility had higher sensitivity than did MaRIA (≥7) (92% vs 75%, respectively; P = .03) but similar specificity (71% vs 74%, respectively; P >.99). The area under the receiver operating characteristic curve for Motility was 0.86 and 0.87 with CDEIS and EAIS as the standard of reference, respectively. Conclusion The terminal ileal Motility score showed good agreement with endoscopic and histopathologic activity in Crohn disease. © RSNA, 2018 Online supplemental material is available for this article.


Subject(s)
Crohn Disease/diagnostic imaging , Crohn Disease/physiopathology , Ileum/diagnostic imaging , Ileum/physiopathology , Magnetic Resonance Imaging/methods , Adolescent , Adult , Aged , Biomarkers , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Severity of Illness Index , Young Adult
17.
Lancet Gastroenterol Hepatol ; 3(8): 548-558, 2018 08.
Article in English | MEDLINE | ID: mdl-29914843

ABSTRACT

BACKGROUND: Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. METHODS: We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. FINDINGS: 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72-86]) and presence (97% [91-99]) were significantly greater than that of ultrasound (70% [62-78] for disease extent, 92% [84-96] for disease presence); a 10% (95% CI 1-18; p=0·027) difference for extent, and 5% (1-9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85-98]) was significantly greater than that of ultrasound (81% [64-91]); a difference of 14% (1-27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86-99) with MRE and 84% (65-94) with ultrasound (difference 12% [0-25]; p=0·054). There were no serious adverse events. INTERPRETATION: Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. FUNDING: National Institute of Health and Research Health Technology Assessment.


Subject(s)
Crohn Disease/diagnostic imaging , Intestine, Small/diagnostic imaging , Magnetic Resonance Imaging , Ultrasonography , Adolescent , Adult , Female , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Sensitivity and Specificity , Young Adult
18.
BMC Cancer ; 17(1): 299, 2017 05 02.
Article in English | MEDLINE | ID: mdl-28464835

ABSTRACT

BACKGROUND AND AIMS: Rapid and accurate cancer staging following diagnosis underpins patient management, in particular the identification of distant metastatic disease. Current staging guidelines recommend sequential deployment of various imaging platforms such as computerised tomography (CT) and positron emission tomography (PET) which can be time and resource intensive and onerous for patients. Recent studies demonstrate that whole body magnetic resonance Imaging (WB-MRI) may stage cancer efficiently in a single visit, with potentially greater accuracy than current staging investigations. The Streamline trials aim to evaluate whether WB-MRI increases per patient detection of metastases in non-small cell lung and colorectal cancer compared to standard staging pathways. METHODS: The Streamline trials are multicentre, non-randomised, single-arm, prospective diagnostic accuracy studies with a novel design to capture patient management decisions during staging pathways. The two trials recruit adult patients with proven or highly suspected new diagnosis of primary colorectal (Streamline C) or non-small cell lung cancer (Streamline L) referred for staging. Patients undergo WB-MRI in addition to standard staging investigations. Strict blinding protocols are enforced for those interpreting the imaging. A first major treatment decision is made by the multi-disciplinary team prior to WB-MRI revelation based on standard staging investigations only, then based on the WB-MRI and any additional tests precipitated by WB-MRI, and finally based on all available test results. The reference standard is derived by a multidisciplinary consensus panel who assess 12 months of follow-up data to adjudicate on the TNM stage at diagnosis. Health psychology assessment of patients' experiences of the cancer staging pathway will be undertaken via interviews and questionnaires. A cost (effectiveness) analysis of WB-MRI compared to standard staging pathways will be performed. DISCUSSION: We describe a novel approach to radiologist and clinician blinding to ascertain the 'true' diagnostic accuracy of differing imaging pathways and discuss our approach to assessing the impact of WB-MRI on clinical decision making in real-time. The Streamline trials will compare WB-MRI and standard imaging pathways in the same patients, thereby informing the most accurate and efficient approach to staging. TRIAL REGISTRATION: Streamline C ISRCTN43958015 (registered 25/7/2012). Streamline L ISRCTN50436483 (registered 31/7/2012).


Subject(s)
Colorectal Neoplasms/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Neoplasm Staging/methods , Whole Body Imaging/methods , Humans , Non-Randomized Controlled Trials as Topic , Patient Satisfaction , Prospective Studies , Surveys and Questionnaires
19.
PLoS One ; 12(1): e0168317, 2017.
Article in English | MEDLINE | ID: mdl-28072831

ABSTRACT

MRI has recently been applied as a tool to quantitatively evaluate the response to therapy in patients with Crohn's disease, and is the preferred choice for repeated imaging. Bowel wall thickness on MRI is an important biomarker of underlying inflammatory activity, being abnormally increased in the acute phase and reducing in response to successful therapy; however, a poor level of interobserver agreement of measured thickness is reported and therefore a system for accurate, robust and reproducible measurements is desirable. We propose a novel method for estimating bowel wall-thickness to improve the poor interobserver agreement of the manual procedure. We show that the variability of wall thickness measurement between the algorithm and observer measurements (0.25mm ± 0.81mm) has differences which are similar to observer variability (0.16mm ± 0.64mm).


Subject(s)
Crohn Disease/diagnostic imaging , Crohn Disease/pathology , Magnetic Resonance Imaging , Models, Statistical , Adult , Algorithms , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Workflow , Young Adult
20.
Eur Radiol ; 27(2): 589-597, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27048528

ABSTRACT

OBJECTIVES: To associate MRI textural analysis (MRTA) with MRI and histological Crohn's disease (CD) activity. METHODS: Sixteen patients (mean age 39.5 years, 9 male) undergoing MR enterography before ileal resection were retrospectively analysed. Thirty-six small (≤3 mm) ROIs were placed on T2-weighted images and location-matched histological acute inflammatory scores (AIS) measured. MRI activity (mural thickness, T2 signal, T1 enhancement) (CDA) was scored in large ROIs. MRTA features (mean, standard deviation, mean of positive pixels (MPP), entropy, kurtosis, skewness) were extracted using a filtration histogram technique. Spatial scale filtration (SSF) ranged from 2 to 5 mm. Regression (linear/logistic) tested associations between MRTA and AIS (small ROIs), and CDA/constituent parameters (large ROIs). RESULTS: Skewness (SSF = 2 mm) was associated with AIS [regression coefficient (rc) 4.27, p = 0.02]. Of 120 large ROI analyses (for each MRI, MRTA feature and SSF), 15 were significant. Entropy (SSF = 2, 3 mm) and kurtosis (SSF = 3 mm) were associated with CDA (rc 0.9, 1.0, -0.45, p = 0.006-0.01). Entropy and mean (SSF = 2-4 mm) were associated with T2 signal [odds ratio (OR) 2.32-3.16, p = 0.02-0.004], [OR 1.22-1.28, p = 0.03-0.04]. MPP (SSF = 2 mm) was associated with mural thickness (OR 0.91, p = 0.04). Kurtosis (SSF = 3 mm), standard deviation (SSF = 5 mm) were associated with decreased T1 enhancement (OR 0.59, 0.42, p = 0.004, 0.007). CONCLUSIONS: MRTA features may be associated with CD activity. KEY POINTS: • MR texture analysis features may be associated with Crohn's disease histological activity. • Texture analysis features may correlate with MR-dependent Crohn's disease activity scores. • The utility of MR texture analysis in Crohn's disease merits further investigation.


Subject(s)
Crohn Disease/diagnostic imaging , Ileum/surgery , Intestines/diagnostic imaging , Magnetic Resonance Imaging/methods , Preoperative Care/methods , Adolescent , Adult , Aged , Crohn Disease/pathology , Crohn Disease/surgery , Female , Humans , Intestines/pathology , Intestines/surgery , Male , Middle Aged , Retrospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...