Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
2.
Nature ; 589(7843): 527-531, 2021 01.
Article in English | MEDLINE | ID: mdl-33505036

ABSTRACT

The energy levels of hydrogen-like atomic systems can be calculated with great precision. Starting from their quantum mechanical solution, they have been refined over the years to include the electron spin, the relativistic and quantum field effects, and tiny energy shifts related to the complex structure of the nucleus. These energy shifts caused by the nuclear structure are vastly magnified in hydrogen-like systems formed by a negative muon and a nucleus, so spectroscopy of these muonic ions can be used to investigate the nuclear structure with high precision. Here we present the measurement of two 2S-2P transitions in the muonic helium-4 ion that yields a precise determination of the root-mean-square charge radius of the α particle of 1.67824(83) femtometres. This determination from atomic spectroscopy is in excellent agreement with the value from electron scattering1, but a factor of 4.8 more precise, providing a benchmark for few-nucleon theories, lattice quantum chromodynamics and electron scattering. This agreement also constrains several beyond-standard-model theories proposed to explain the proton-radius puzzle2-5, in line with recent determinations of the proton charge radius6-9, and establishes spectroscopy of light muonic atoms and ions as a precise tool for studies of nuclear properties.

3.
Phys Rev Lett ; 120(18): 183001, 2018 May 04.
Article in English | MEDLINE | ID: mdl-29775374

ABSTRACT

We present a new measurement of the 1S-3S two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic beam, with a relative uncertainty of 9×10^{-13}. The proton charge radius deduced from this measurement, r_{p}=0.877(13) fm, is in very good agreement with the current CODATA-recommended value. This result contributes to the ongoing search to solve the proton charge radius puzzle, which arose from a discrepancy between the CODATA value and a more precise determination of r_{p} from muonic hydrogen spectroscopy.

4.
Science ; 353(6300): 669-73, 2016 Aug 12.
Article in English | MEDLINE | ID: mdl-27516595

ABSTRACT

The deuteron is the simplest compound nucleus, composed of one proton and one neutron. Deuteron properties such as the root-mean-square charge radius rd and the polarizability serve as important benchmarks for understanding the nuclear forces and structure. Muonic deuterium µd is the exotic atom formed by a deuteron and a negative muon µ(-). We measured three 2S-2P transitions in µd and obtain r(d) = 2.12562(78) fm, which is 2.7 times more accurate but 7.5σ smaller than the CODATA-2010 value r(d) = 2.1424(21) fm. The µd value is also 3.5σ smaller than the r(d) value from electronic deuterium spectroscopy. The smaller r(d), when combined with the electronic isotope shift, yields a "small" proton radius r(p), similar to the one from muonic hydrogen, amplifying the proton radius puzzle.

5.
Rev Sci Instrum ; 86(5): 053102, 2015 May.
Article in English | MEDLINE | ID: mdl-26026509

ABSTRACT

Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work, we report on a fitting technique used to account for different detector responses resulting from photoabsorption in the various avalanche photodiode layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2 and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g., to distinguish between x-rays and MeV electrons in our experiment.

6.
Science ; 339(6118): 417-20, 2013 Jan 25.
Article in English | MEDLINE | ID: mdl-23349284

ABSTRACT

Accurate knowledge of the charge and Zemach radii of the proton is essential, not only for understanding its structure but also as input for tests of bound-state quantum electrodynamics and its predictions for the energy levels of hydrogen. These radii may be extracted from the laser spectroscopy of muonic hydrogen (µp, that is, a proton orbited by a muon). We measured the 2S(1/2)(F=0)-2P(3/2)(F=1) transition frequency in µp to be 54611.16(1.05) gigahertz (numbers in parentheses indicate one standard deviation of uncertainty) and reevaluated the 2S(1/2)(F=1)-2P(3/2)(F=2) transition frequency, yielding 49881.35(65) gigahertz. From the measurements, we determined the Zemach radius, r(Z) = 1.082(37) femtometers, and the magnetic radius, r(M) = 0.87(6) femtometer, of the proton. We also extracted the charge radius, r(E) = 0.84087(39) femtometer, with an order of magnitude more precision than the 2010-CODATA value and at 7σ variance with respect to it, thus reinforcing the proton radius puzzle.

7.
Phys Rev Lett ; 106(8): 080801, 2011 Feb 25.
Article in English | MEDLINE | ID: mdl-21405559

ABSTRACT

We report a new measurement of the ratio h/m(Rb) between the Planck constant and the mass of (87)Rb atom. A new value of the fine structure constant is deduced, α(-1)=137.035999037(91) with a relative uncertainty of 6.6×10(-10). Using this determination, we obtain a theoretical value of the electron anomaly a(e)=0.00115965218113(84), which is in agreement with the experimental measurement of Gabrielse [a(e)=0.00115965218073(28)]. The comparison of these values provides the most stringent test of the QED. Moreover, the precision is large enough to verify for the first time the muonic and hadronic contributions to this anomaly.

8.
Nature ; 466(7303): 213-6, 2010 Jul 08.
Article in English | MEDLINE | ID: mdl-20613837

ABSTRACT

The proton is the primary building block of the visible Universe, but many of its properties-such as its charge radius and its anomalous magnetic moment-are not well understood. The root-mean-square charge radius, r(p), has been determined with an accuracy of 2 per cent (at best) by electron-proton scattering experiments. The present most accurate value of r(p) (with an uncertainty of 1 per cent) is given by the CODATA compilation of physical constants. This value is based mainly on precision spectroscopy of atomic hydrogen and calculations of bound-state quantum electrodynamics (QED; refs 8, 9). The accuracy of r(p) as deduced from electron-proton scattering limits the testing of bound-state QED in atomic hydrogen as well as the determination of the Rydberg constant (currently the most accurately measured fundamental physical constant). An attractive means to improve the accuracy in the measurement of r(p) is provided by muonic hydrogen (a proton orbited by a negative muon); its much smaller Bohr radius compared to ordinary atomic hydrogen causes enhancement of effects related to the finite size of the proton. In particular, the Lamb shift (the energy difference between the 2S(1/2) and 2P(1/2) states) is affected by as much as 2 per cent. Here we use pulsed laser spectroscopy to measure a muonic Lamb shift of 49,881.88(76) GHz. On the basis of present calculations of fine and hyperfine splittings and QED terms, we find r(p) = 0.84184(67) fm, which differs by 5.0 standard deviations from the CODATA value of 0.8768(69) fm. Our result implies that either the Rydberg constant has to be shifted by -110 kHz/c (4.9 standard deviations), or the calculations of the QED effects in atomic hydrogen or muonic hydrogen atoms are insufficient.

9.
Phys Rev Lett ; 102(24): 240402, 2009 Jun 19.
Article in English | MEDLINE | ID: mdl-19658984

ABSTRACT

The sensitivity of an inertial sensor based on an atomic interferometer is proportional to the velocity separation of atoms in the two arms of the interferometer. In this Letter we describe how Bloch oscillations can be used to increase this separation and to create a large momentum transfer (LMT) beam splitter. We experimentally demonstrate a separation of 10 recoil velocities. Light shifts during the acceleration introduce phase fluctuations which can reduce the fringes contrast. We precisely calculate this effect and demonstrate that it can be significantly reduced by using a suitable combination of LMT pulses. We finally show that this method seems to be very promising to realize a LMT beam splitter with several tens of recoils and a very good efficiency.

10.
Phys Rev Lett ; 101(23): 230801, 2008 Dec 05.
Article in English | MEDLINE | ID: mdl-19113536

ABSTRACT

We report a new experimental scheme which combines atom interferometry with Bloch oscillations to provide a new measurement of the ratio h/mRb. By using Bloch oscillations, we impart to the atoms up to 1600 recoil momenta and thus we improve the accuracy on the recoil velocity measurement. The deduced value of h/mRb leads to a new determination of the fine structure constant alpha(-1) =137.03599945 (62) with a relative uncertainty of 4.6 x 10(-9). The comparison of this result with the value deduced from the measurement of the electron anomaly provides the most stringent test of QED.

11.
Phys Rev Lett ; 96(3): 033001, 2006 Jan 27.
Article in English | MEDLINE | ID: mdl-16486694

ABSTRACT

We report an accurate measurement of the recoil velocity of 87Rb atoms based on Bloch oscillations in a vertical accelerated optical lattice. We transfer about 900 recoil momenta with an efficiency of 99.97% per recoil. A set of 72 measurements of the recoil velocity, each one with a relative uncertainty of about 33 ppb in 20 min integration time, leads to a determination of the fine structure constant with a statistical relative uncertainty of 4.4 ppb. The detailed analysis of the different systematic errors yields to a relative uncertainty of 6.7 ppb. The deduced value of alpha-1 is 137.035 998 78(91).

12.
Phys Rev Lett ; 92(25 Pt 1): 253001, 2004 Jun 25.
Article in English | MEDLINE | ID: mdl-15245001

ABSTRACT

We use Bloch oscillations in a horizontal moving standing wave to transfer a large number of photon recoils to atoms with a high efficiency (99.5% per cycle). By measuring the photon recoil of 87Rb, using velocity-selective Raman transitions to select a subrecoil velocity class and to measure the final accelerated velocity class, we have determined h/m(Rb) with a relative precision of 0.4 ppm. To exploit the high momentum transfer efficiency of our method, we are developing a vertical standing wave setup. This will allow us to measure h/m(Rb) better than 10(-8) and hence the fine structure constant alpha with an uncertainty close to the most accurate value coming from the (g-2) determination.

13.
Appl Opt ; 41(36): 7702-6, 2002 Dec 20.
Article in English | MEDLINE | ID: mdl-12510941

ABSTRACT

The frequency shift of the light owing to a cavity length modulation has been observed with the spectroscopy of the 1S-3S two-photon transition in hydrogen. The excitation of this transition occurs at a wavelength of 205 nm. One produces this radiation by frequency doubling a 410-nm radiation in an enhancement ring cavity. The length modulation of this cavity induces frequency shifts and a splitting of the observed 1S-3S line. We obtain a good agreement between the experiment and the theoretical analysis.

SELECTION OF CITATIONS
SEARCH DETAIL
...