Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Physiol Funct Imaging ; 42(6): 443-452, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36039853

ABSTRACT

PURPOSE: Positron emission tomography-computed tomography (PET-CT) using prostate-specific membrane antigen (PSMA) ligands is a method for imaging prostate cancer. A recent tracer, 18 F-PSMA-1007, offers advantages concerning production and biokinetics compared to the standard tracer (68 Ga-PSMA-11). Until now, radiation dosimetry data for this ligand was limited to the material of three healthy volunteers. The purpose of this study is to study the biokinetics and dosimetry of 18 F-PSMA-1007. METHODS: Twelve patients with prostate cancer were injected with 4 MBq/kg 18 F-PSMA-1007. Eight PET-CT scans with concomitant blood sampling were performed up to 330 min after injection. Urine was collected until the following morning. Volumes of interest for radiation-sensitive organs and organs with high uptake of 18 F-PSMA-1007 were drawn in the PET images. A biokinetic compartment model was developed using activity data from PET images and blood and urine samples. Time-activity curves and time-integrated activity coefficients for all delineated organs were calculated. The software IDAC-dose 2.1 was used to calculate the absorbed and effective doses. RESULTS: High concentrations of activity were noted in the liver, kidneys, parts of the small intestine, spleen, salivary glands, and lacrimal glands. The elimination through urine was 8% of injected activity in 20 h. The highest absorbed doses coefficients were in the lacrimal glands, kidneys, salivary glands, liver, and spleen (98-66 µGy/MBq). The effective dose coefficient was 25 µSv/MBq. CONCLUSION: The effective dose of 18 F-PSMA-1007 is 6.0-8.0 mSv for a typical patient weighing 80 kg injected with 3-4 MBq/kg.


Subject(s)
Positron Emission Tomography Computed Tomography , Prostatic Neoplasms , Humans , Ligands , Male , Niacinamide/analogs & derivatives , Oligopeptides , Positron Emission Tomography Computed Tomography/methods , Prostatic Neoplasms/diagnostic imaging , Radiometry , Radiopharmaceuticals
2.
Clin Physiol Funct Imaging ; 42(6): 381-388, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35866190

ABSTRACT

BACKGROUND: Positron emission tomography-computed tomography (PET-CT) with [18 F]-fluorocholine (FCH) is used to detect and stage metastatic lymph nodes in patients with prostate cancer. Improvements to hardware and software have recently been made. We compared the capability of detecting regional lymph node metastases using conventional and digital silicon photomultiplier (SiPM)-based PET-CT technology for FCH. Extended pelvic lymph node dissection (ePLND) histopathology was used as a reference method. METHODS: The study retrospectively examined 177 patients with intermediate or high-risk prostate cancer who had undergone staging with FCH PET-CT before ePLND. Images were obtained with either the conventional Philips Gemini PET-CT (n = 93) or the digital SiPM-based GE Discovery MI PET-CT (n = 84) and compared. RESULTS: Images that were obtained using the Philips Gemini PET-CT system showed 19 patients (20%) with suspected lymph node metastases, whereas the GE Discovery MI PET-CT revealed 36 such patients (43%). The sensitivity, specificity, and positive and negative predictive values were 0.3, 0.84, 0.47, and 0.72 for the Philips Gemini, while they were 0.58, 0.62, 0.31, and 0.83 for the GE Discovery MI, respectively. The areas under the curves in a receiver operating characteristic curve analysis were similar between the two PET-CT systems (0.57 for Philips Gemini and 0.58 for GE Discovery MI, p = 0.89). CONCLUSIONS: Marked differences in sensitivity and specificity were found for the different PET-CT systems, although the overall diagnostic performance was similar. These differences are probably due to differences in both hardware and software, including reconstruction algorithms, and should be considered when new technology is introduced.


Subject(s)
Positron Emission Tomography Computed Tomography , Prostatic Neoplasms , Choline/analogs & derivatives , Humans , Lymph Nodes/diagnostic imaging , Lymphatic Metastasis , Male , Neoplasm Staging , Positron Emission Tomography Computed Tomography/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Radiopharmaceuticals , Retrospective Studies
3.
Scand J Urol ; 55(4): 293-297, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33939583

ABSTRACT

BACKGROUND: Previous studies have investigated [18F]-fluorocholine (FCH) positron emission tomography with computed tomography (PET/CT) in primary staging of men with intermediate or high-risk prostate cancer and have generally shown high specificity and poor sensitivity. FCH PET/CT is not recommended for the primary staging of metastases in the European guidelines for prostate cancer. However, it has been an option in the Swedish recommendations. Our aim was to assess PET/CT for primary staging of lymph node metastases before robotic-assisted laparoscopic prostatectomy (RALP) with extended pelvic lymph node dissection (ePLND) in patients with intermediate or high-risk prostate cancer. METHOD: We identified all men with prostate cancer undergoing FCH PET/CT for initial staging followed by RALP and ePLND at Skåne University Hospital between 2015 and 2018. The result from PET/CT scan was compared with pathology report as the reference method for calculation of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). RESULTS: In total, 252 patients were included in the final analysis. Among 85 patients with a suspicion of regional lymph node metastases on FCH PET/CT only 31 had pathology-proven metastases. The sensitivity was 43% (95% CI 0.32-0.55) and the specificity 70% (95% CI 0.63-0.76) for PET/CT to predict lymph node metastases. PPV was 36% and NPV was 75%. Risk group analyses showed similar results. CONCLUSION: Our study emphasizes the poor performance of FCH PET/CT to predict lymph node metastasis in intermediate and high-risk prostate cancer. The method should be replaced with newer radiopharmaceuticals, such as prostate-specific membrane antigen ligands.


Subject(s)
Laparoscopy , Prostatic Neoplasms , Robotic Surgical Procedures , Choline/analogs & derivatives , Humans , Lymph Node Excision , Lymphatic Metastasis , Male , Neoplasm Staging , Positron Emission Tomography Computed Tomography , Prostatectomy , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Prostatic Neoplasms/surgery , Retrospective Studies
4.
EJNMMI Phys ; 6(1): 5, 2019 Mar 21.
Article in English | MEDLINE | ID: mdl-30900064

ABSTRACT

BACKGROUND: Recently, the block-sequential regularized expectation maximization (BSREM) reconstruction algorithm was commercially introduced (Q.Clear, GE Healthcare, Milwaukee, WI, USA). However, the combination of noise-penalizing factor (ß), acquisition time, and administered activity for optimal image quality has not been established for 18F-fluorocholine (FCH). The aim was to compare image quality and diagnostic performance of different reconstruction protocols for patients with prostate cancer being examined with 18F-FCH on a silicon photomultiplier-based PET-CT. Thirteen patients were included, injected with 4 MBq/kg, and images were acquired after 1 h. Images were reconstructed with frame durations of 1.0, 1.5, and 2.0 min using ß of 150, 200, 300, 400, 500, and 550. An ordered subset expectation maximization (OSEM) reconstruction with a frame duration of 2.0 min was used for comparison. Images were quantitatively analyzed regarding standardized uptake values (SUV) in metastatic lymph nodes, local background, and muscle to obtain contrast-to-noise ratios (CNR) as well as the noise level in muscle. Images were analyzed regarding image quality and number of metastatic lymph nodes by two nuclear medicine physicians. RESULTS: The highest median CNR was found for BSREM with a ß of 300 and a frame duration of 2.0 min. The OSEM reconstruction had the lowest median CNR. Both the noise level and lesion SUVmax decreased with increasing ß. For a frame duration of 1.5 min, the median quality score was highest for ß 400-500, and for a frame duration of 2.0 min the score was highest for ß 300-500. There was no statistically significant difference in the number of suspected lymph node metastases between the different image series for one of the physicians, and for the other physician the number of lymph nodes differed only for one combination of image series. CONCLUSIONS: To achieve acceptable image quality at 4 MBq/kg 18F-FCH, we propose using a ß of 400-550 with a frame duration of 1.5 min. The lower ß should be used if a high CNR is desired and the higher if a low noise level is important.

SELECTION OF CITATIONS
SEARCH DETAIL
...