ABSTRACT

The PET instrument aboard the SAMPEX satellite has provided us with long-term intra-calibrated observations of geomagnetically trapped protons and deuterons in the inner zone, suitable for use in constraining the low-altitude portions of radiation belt models being developed as successors to AP-8. These observations have been summarized elsewhere (Looper et al., 1996). Here we report a detection of geomagnetically-trapped tritum at energies from 14 to 35 MeV/nuc below L = 1.2, at about 1/8 the flux of deuterium previously reported at that location and at similar energy per nucleon. We also demonstrate the utility of the SAMPEX/PET observations for measuring the east-west anisotropy in the trapped particle flux at low altitudes, which is due to displacement of particle gyrocenters from the position of observation in a region of strong flux gradients. This anisotropy is implicitly ignored in omnidirectional radiation-flux models, but it can be important to mission planners considering how to distribute shielding over the surface of oriented spacecraft in low Earth orbit.


Subject(s)
Deuterium , Solar Activity , Space Flight/instrumentation , Spacecraft/instrumentation , Tritium , Anisotropy , Atlantic Ocean , Electrons , Magnetics , Protons , Radiation Monitoring , Radiation Protection , South America