Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38847828

ABSTRACT

Reliable dosimetry systems are crucial for radiobiological experiments either to quantify the biological consequences of ionizing radiation or to reproduce results by other laboratories. Also, they are essential for didactic purposes in the field of radiation research. Professional dosemeters are expensive and difficult to use in exposure facilities with closed exposure chambers. Consequently, a simple, inexpensive, battery-driven dosemeter was developed that can be easily built using readily available components. Measurements were performed to validate its readout with photons of different energy and dose rate and to demonstrate the applicability of the dosemeter. It turned out that the accuracy of the dose measurements using the developed dosemeter was better than 10%, which is satisfactory for radiobiological experiments. It is concluded that this dosemeter can be used both for determining the dose rates of an exposure facility and for educational purposes.

2.
J Nucl Med Technol ; 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627014

ABSTRACT

Fibroblast activation protein is a promising target for oncologic molecular imaging with radiolabeled fibroblast activation protein inhibitors (FAPI) in a large variety of cancers. However, there are yet no published recommendations on how to set up an optimal imaging protocol for FAPI PET/CT. It is important to optimize the acquisition duration and strive toward an acquisition that is sufficiently short while simultaneously providing sufficient image quality to ensure a reliable diagnosis. The aim of this study was to evaluate the feasibility of reducing the acquisition duration of [68Ga]FAPI-46 imaging while maintaining satisfactory image quality, with certainty that the radiologist's ability to make a clinical diagnosis would not be affected. Methods: [68Ga]FAPI-46 PET/CT imaging was performed on 10 patients scheduled for surgical resection of suspected pancreatic cancer, 60 min after administration of 3.6 ± 0.2 MBq/kg. The acquisition time was 4 min/bed position, and the raw PET data were statistically truncated and reconstructed to represent images with an acquisition duration of 1, 2, and 3 min/bed position, additional to the reference images of 4 min/bed position. Four image quality criteria that focused on the ability to distinguish specific anatomic details, as well as perceived image noise and overall image quality, were scored on a 4-point Likert scale and analyzed with mixed-effects ordinal logistic regression. Results: A trend toward increasing image quality scores with increasing acquisition duration was observed for all criteria. For the overall image quality, there was no significant difference between 3 and 4 min/bed position, whereas 1 and 2 min/bed position were rated significantly (P < 0.05) lower than 4 min/bed position. For the other criteria, all images with a reduced acquisition duration were rated significantly inferior to images obtained at 4 min/bed position. Conclusion: The acquisition duration can be reduced from 4 to 3 min/bed position while maintaining satisfactory image quality. Reducing the acquisition duration to 2 min/bed position or lower is not recommended since it results in inferior-quality images so noisy that clinical interpretation is significantly disrupted.

3.
J Nucl Med ; 65(5): 700-707, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38548353

ABSTRACT

Patients with HER2-low metastatic breast cancer (mBC), defined as an immunohistochemistry (IHC) score of 1+ or 2+ without HER2 gene amplification, may benefit from HER2 antibody-drug conjugates. Identifying suitable candidates is a clinical challenge because of spatial and temporal heterogeneity in HER2 expression and discrepancies in pathologic reporting. We aimed to investigate the feasibility and safety of HER2-specific PET imaging with [68Ga]Ga-ABY-025 for visualization of HER2-low mBC. Methods: A prospective pilot study was done with 10 patients who had HER2-low mBC, as part of a phase 2 basket imaging study with [68Ga]Ga-ABY-025 in HER2-expressing solid tumors. Patients were recruited at the Breast Clinic at the Karolinska University Hospital, Stockholm, Sweden. PET/CT images were acquired 3 h after injection of 200 MBq of [68Ga]Ga-ABY-025. The SUVmax was used to quantify tracer uptake. Ultrasound-guided tumor biopsies were guided by results from the HER2 PET. The main outcome-the safety and feasibility of HER2 PET in patients with HER2-low mBC, measured the occurrence of possible procedure-related adverse events. Results: Ten patients with HER2-low mBC underwent [68Ga]Ga-ABY-025 PET/CT with paired tumor biopsies. No adverse events occurred. In all patients, [68Ga]Ga-ABY-025-avid lesions with substantial intra- and interindividual heterogeneity in tracer uptake were noted. In 8 of 10 patients with ABY-025-avid lesions, the HER2-low status of the corresponding lesions was confirmed by IHC or in situ hybridization. Two patients had an IHC score of 0 in the tumor biopsies:1 in a cutaneous lesion with a low SUVmax and 1 in a liver metastasis with a high SUVmax but a "cold" core. Conclusion: The visualization of HER2-low mBC with [68Ga]Ga-ABY-025 PET/CT was feasible and safe. Areas of tracer uptake showed varying levels of HER2 expression on IHC. The observed intra- and interindividual heterogeneity in [68Ga]Ga-ABY-025 uptake suggested that HER2 PET might be used as a tool for the noninvasive assessment of disease heterogeneity and has the potential to identify patients in whom HER2-targeted drugs can have a clinical benefit.


Subject(s)
Breast Neoplasms , Peptide Fragments , Positron Emission Tomography Computed Tomography , Receptor, ErbB-2 , Staphylococcal Protein A , Humans , Pilot Projects , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/metabolism , Receptor, ErbB-2/metabolism , Female , Middle Aged , Aged , Gallium Radioisotopes , Adult , Prospective Studies , Radiopharmaceuticals , Positron-Emission Tomography
SELECTION OF CITATIONS
SEARCH DETAIL
...