Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Spine Surg ; 36(10): 419-425, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37491717

ABSTRACT

STUDY DESIGN: Retrospective Cohort. OBJECTIVE: To determine if outcomes varied between patients based on physical therapy (PT) attendance after lumbar fusion surgery. SUMMARY OF BACKGROUND DATA: The literature has been mixed regarding the efficacy of postoperative PT to improve disability and back pain, as measured by patient-reported outcome measures. Given the prevalence of PT referrals and lack of high-quality evidence, there is a need for additional studies investigating the efficacy of PT after lumbar fusion surgery to aid in developing robust clinical guidelines. METHODS: We retrospectively identified patients receiving lumbar fusion surgery by current procedural terminology codes and separated them into 2 groups based on whether PT was prescribed. Electronic medical records were reviewed for patient and surgical characteristics, PT utilization, and surgical outcomes. Patient-reported outcome measures (PROMs) were identified and compared preoperatively, at 90 days postoperatively and one year postoperatively. RESULTS: The two groups had similar patient characteristics and comorbidities and demonstrated no significant differences between readmission, complication, and revision rates after surgery. Patients that attended PT had significantly more fused levels (1.41 ± 0.64 vs. 1.32 ± 0.54, P =0.027), longer operative durations (234 ± 96.4 vs. 215 ± 86.1 min, P =0.012), and longer postoperative hospital stays (3.35 ± 1.68 vs. 3.00 ± 1.49 days, P =0.004). All groups improved similarly by Oswestry Disability Index, short form-12 physical and mental health subsets, and back and leg pain by Visual Analog Scale at 90-day and 1-year follow-up. CONCLUSION: Our data suggest that physical therapy does not significantly impact PROMs after lumbar fusion surgery. Given the lack of data suggesting clear benefit of PT after lumbar fusion, surgeons should consider more strict criteria when recommending physical therapy to their patients after lumbar fusion surgery. LEVEL OF EVIDENCE: Level-Ⅲ.


Subject(s)
Back Pain , Spinal Fusion , Humans , Retrospective Studies , Back Pain/etiology , Lumbosacral Region/surgery , Pain Measurement , Spinal Fusion/adverse effects , Lumbar Vertebrae/surgery , Treatment Outcome
2.
J AOAC Int ; 103(3): 833-842, 2020 Jun 01.
Article in English | MEDLINE | ID: mdl-33241359

ABSTRACT

BACKGROUND: CERTUS Environmental Listeria species Detection Kit (CERTUS EL Detection Kit) is a real-time, bio-contained assay designed to accurately detect Listeria species (L. grayi, L. innocua, L. ivanovii, L. marthii, L. monocytogenes, L. seeligeri, and L. welshimeri) from environmental surface matrixes using an antibody-coupled magnetic microparticle with a Surface Enhanced Raman Spectroscopy (SERS) nanoparticle technology test system paired with proprietary CERTUS EL Selective Growth Media and CERTUS Detection Unit. OBJECTIVE: The method was evaluated for AOAC®Performance Tested MethodSM certification. METHODS: Inclusivity and exclusivity, matrix studies, product consistency and stability were conducted to evaluate the CERTUS EL Detection Kit. RESULTS: In the matrix studies, stainless steel, ceramic tile, plastic (polystyrene) and sealed concrete environmental surfaces (4 × 4" test areas) were tested. No statistically significant differences were found by Probability of Detection analysis (POD) in any of the matrixes when results were compared to the U.S. Food and Drug Administration cultural microbiology reference method for Listeria. The CERTUS EL Detection Kit correctly identified all 50 target Listeria isolates and correctly excluded all 30 non-target strains that were analyzed. Probability of Detection analysis of CERTUS EL Detection Kit robustness, product consistency (lot-to-lot) and stability studies demonstrated no statistically significant differences, and no variation was observed between instruments. CONCLUSIONS: The data collected in these studies demonstrate that the CERTUS EL Detection Kit is a reliable method for the rapid and specific detection of Listeria from stainless steel, ceramic tile, plastic (polystyrene) and sealed concrete environmental surfaces.


Subject(s)
Listeria , Bacteriological Techniques , Environmental Microbiology , Food Microbiology , Plastics , Stainless Steel
3.
Arch Pathol Lab Med ; 140(10): 1085-91, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27388684

ABSTRACT

CONTEXT: -Most current proficiency testing challenges for next-generation sequencing assays are methods-based proficiency testing surveys that use DNA from characterized reference samples to test both the wet-bench and bioinformatics/dry-bench aspects of the tests. Methods-based proficiency testing surveys are limited by the number and types of mutations that either are naturally present or can be introduced into a single DNA sample. OBJECTIVE: -To address these limitations by exploring a model of in silico proficiency testing in which sequence data from a single well-characterized specimen are manipulated electronically. DESIGN: -DNA from the College of American Pathologists reference genome was enriched using the Illumina TruSeq and Life Technologies AmpliSeq panels and sequenced on the MiSeq and Ion Torrent platforms, respectively. The resulting data were mutagenized in silico and 26 variants, including single-nucleotide variants, deletions, and dinucleotide substitutions, were added at variant allele fractions (VAFs) from 10% to 50%. Participating clinical laboratories downloaded these files and analyzed them using their clinical bioinformatics pipelines. RESULTS: -Laboratories using the AmpliSeq/Ion Torrent and/or the TruSeq/MiSeq participated in the 2 surveys. On average, laboratories identified 24.6 of 26 variants (95%) overall and 21.4 of 22 variants (97%) with VAFs greater than 15%. No false-positive calls were reported. The most frequently missed variants were single-nucleotide variants with VAFs less than 15%. Across both challenges, reported VAF concordance was excellent, with less than 1% median absolute difference between the simulated VAF and mean reported VAF. CONCLUSIONS: -The results indicate that in silico proficiency testing is a feasible approach for methods-based proficiency testing, and demonstrate that the sensitivity and specificity of current next-generation sequencing bioinformatics across clinical laboratories are high.


Subject(s)
Computer Simulation , High-Throughput Nucleotide Sequencing/methods , Laboratory Proficiency Testing/methods , Pathology, Clinical/methods , Alleles , DNA/chemistry , DNA/genetics , Feasibility Studies , Gene Frequency , Genetic Testing/methods , Genome, Human/genetics , Humans , Mutation , Polymorphism, Single Nucleotide , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...