Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Circ Cardiovasc Interv ; 17(7): e013729, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38666384

ABSTRACT

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.


Subject(s)
Angioplasty, Balloon , Aorta, Thoracic , Prosthesis Design , Stents , Humans , Retrospective Studies , Male , Female , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aorta, Thoracic/physiopathology , Treatment Outcome , Time Factors , Risk Factors , Adolescent , Young Adult , Angioplasty, Balloon/instrumentation , Angioplasty, Balloon/adverse effects , Child , Aortic Diseases/diagnostic imaging , Aortic Diseases/therapy , Aortic Diseases/physiopathology , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/physiopathology , Arterial Occlusive Diseases/therapy , Constriction, Pathologic , United States , Aortography
2.
JTCVS Open ; 15: 433-445, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37808023

ABSTRACT

Objectives: Palliative treatment of cyanotic congenital heart disease (CCHD) uses systemic-to-pulmonary conduits, often a modified Blalock-Taussig-Thomas shunt (mBTTs). Expanded polytetrafluoroethylene (ePTFE) mBTTs have associated risks for thrombosis and infection. The Human Acellular Vessel (HAV) (Humacyte, Inc) is a decellularized tissue-engineered blood vessel currently in clinical trials in adults for vascular trauma, peripheral artery disease, and end-stage renal disease requiring hemodialysis. In addition to restoring blood flow, the engineered HAV demonstrates the capacity for host cellular remodeling into native-like vasculature. Here we report preclinical evaluation of a small-diameter (3.5 mm) HAV as a mBTTs in a non-human primate model. Methods: We implanted 3.5 mm HAVs as right subclavian artery to pulmonary artery mBTTs in non-immunosuppressed juvenile rhesus macaques (n = 5). HAV patency, structure, and blood flow were assessed by postoperative imaging from 1 week to 6 months. Histology of HAVs and surrounding tissues was performed. Results: Surgical procedures were well tolerated, with satisfactory anastomoses, showing feasibility of using the 3.5 mm HAV as a mBTTs. All macaques had some immunological reactivity to the human extracellular matrix, as expected in this xenogeneic model. HAV mBTTs remained patent for up to 6 months in animals, exhibiting mild immunoreactivity. Two macaques displaying more severe immunoreactivity to the human HAV material developed midgraft dilatation without bleeding or rupture. HAV repopulation by host cells expressing smooth muscle and endothelial markers was observed in all animals. Conclusions: These findings may support use of 3.5 mm HAVs as mBTTs in CCHD and potentially other pediatric vascular indications.

3.
JACC Cardiovasc Interv ; 16(15): 1917-1928, 2023 08 14.
Article in English | MEDLINE | ID: mdl-37278682

ABSTRACT

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is the first U.S. Food and Drug Administration-approved device for severe pulmonary regurgitation (PR) in the native or surgically repaired right ventricular outflow tract (RVOT). OBJECTIVES: One-year safety and effectiveness of the Harmony TPV were evaluated in patients from the Harmony Native Outflow Tract Early Feasibility Study, Harmony TPV Pivotal Study, and Continued Access Study, representing the largest cohort to date of Harmony TPV recipients. METHODS: Eligible patients had severe PR by echocardiography or PR fraction ≥ 30% by cardiac magnetic resonance imaging and clinical indications for pulmonary valve replacement. The primary analysis included 87 patients who received a commercially available TPV22 (n = 42) or TPV25 (n = 45) device; 19 patients who received an early device iteration prior to its discontinuation were evaluated separately. RESULTS: In the primary analysis, median patient age at treatment was 26 years (IQR: 18-37 years) in the TPV22 group and 29 years (IQR: 19-42 years) in the TPV25 group. At 1 year, there were no deaths; 98% of TPV22 and 91% of TPV25 patients were free from the composite of PR, stenosis, and reintervention (moderate or worse PR, mean RVOT gradient >40 mmHg, device-related RVOT reoperation, and catheter reintervention). Nonsustained ventricular tachycardia occurred in 16% of patients. Most patients had none/trace or mild PR (98% of TPV22 patients, 97% of TPV25 patients). Outcomes with the discontinued device are reported separately. CONCLUSIONS: The Harmony TPV device demonstrated favorable clinical and hemodynamic outcomes across studies and valve types through 1 year. Further follow-up will continue to assess long-term valve performance and durability.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Ventricular Outflow Obstruction , Humans , Cardiac Catheterization , Prospective Studies , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Treatment Outcome , Ventricular Outflow Obstruction/etiology
4.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36995404

ABSTRACT

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Subject(s)
Ductus Arteriosus, Patent , Septal Occluder Device , Infant , Humans , Ductus Arteriosus, Patent/surgery , Treatment Outcome , Cardiac Catheterization/methods , Registries , Time Factors , Retrospective Studies
5.
Pediatr Cardiol ; 44(1): 132-140, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36029321

ABSTRACT

The aim of the study was to determine the variables associated with high-quality (HQ) versus low-quality (LQ) three-dimensional rotational angiography (3DRA) and create guides for optimization of approach to 3DRA in congenital cardiac catheterization (CCC). CCC has adopted 3DRA as a mainstay, but there has not been systematic analysis of approach to and factors associated with HQ 3DRA. This was a single-center, retrospective study of 3DRAs using Canon Infinix-I platform. Reconstructions were graded by 3 interventionalists. Quality was dichotomized into HQ and LQ. Univariable analyses and multivariable logistic regression models were performed. From 8/2016 to 12/2018, 208 3DRAs were performed in 195 CCCs; median age 7 years (2, 16), weight 23 kg (12, 57). The majority of 3DRAs were performed in patients with biventricular physiology (N = 137, 66%) and in pulsatile sites (N = 144, 69%). HQ 3DRA (N = 182, 88%) was associated with greater total injection volume [2.20 mL/kg (1.44, 3.29) vs. 1.62 mL/kg (1.10, 1.98), p = 0.005] and more dilute contrast solution [60% (50, 100) vs. 100% (60, 100), p = 0.007], but not with contrast volume administered (p = 0.2) on univariable analysis. On multivariable logistic regression, HQ 3DRA was significantly associated with patient weight [OR 0.97 (95% CI (0.94, 0.99), p = 0.018], total injection volume [OR 1.04 (95% CI 1.01, 1.07) p = 0.011], and percent contrast solution [OR 0.97 (95% CI 0.95, 1.00), p = 0.022]. These data resulted in creation of scatter plots and a novel 3DRA Nomogram for estimating the probability of HQ 3DRA. This is the first study to create evidence-based contrast dose guides and nomogram for 3DRA in CCC. HQ 3DRA was associated with lower weight, higher total injection volumes, and more dilute contrast solution.


Subject(s)
Imaging, Three-Dimensional , Plastic Surgery Procedures , Humans , Child , Retrospective Studies , Imaging, Three-Dimensional/methods , Angiography/methods , Cardiac Catheterization/methods
6.
J Soc Cardiovasc Angiogr Interv ; 2(6Part A): 101119, 2023.
Article in English | MEDLINE | ID: mdl-39129900

ABSTRACT

Background: Safety events and technical success (TS) have been previously reported for aortic and pulmonary valvuloplasty, but a composite performance measure as a novel, patient-centered strategy has neither been developed nor been studied. This study aims to refine a procedural performance (PP) variable, a composite of TS and procedural safety, for isolated, standard-risk aortic and pulmonary valvuloplasty. Methods: A multicenter review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes registry. Data were collected for all cases of isolated balloon aortic and pulmonary valvuloplasty from 2014 through 2017. Patients were excluded if they were aged <1 month, were inpatient at the time of the procedure, or had significant comorbidities, such as Williams or Noonan syndrome. Criteria for TS were developed and categorized (optimal, satisfactory, and unsatisfactory) by expert consensus based on previous outcome research. Adverse events (AE) were categorized by severity (level 1-5) using established criteria. Level 4 and 5 severity AE were considered high-severity AE. Using criteria of TS and AE severity, PP was divided into 3 composite outcome classes. Factors correlating with class III (suboptimal) PP were analyzed. Results: There were 169 cases of aortic and 270 cases of pulmonary valvuloplasty in the cohorts. In the aortic valvuloplasty cohort, a suboptimal PP (class III) occurred in 14% of cases, mostly due to high-severity AE (7%). No significant correlation between patient or case characteristics and PP was demonstrated. In the pulmonary valvuloplasty cohort, class III PP occurred in 9% of cases, predominantly due to residual valve gradient, which correlated with lower weight (P = .02). Conclusions: We designed a composite variable of PP consisting of TS and safety as a comprehensive measure of outcome. Incorporating both TS and AE may better reflect patient outcome than each metric measured separately. PP indices may identify areas for further investigation and quality improvement.

7.
JACC Adv ; 1(5): 100143, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36471862

ABSTRACT

Background: The COVID-19 pandemic has posed tremendous stress on the health care system. Its effects on pediatric/congenital catheterization program practice and performance have not been described. Objectives: The purpose of this study was to evaluate how case volumes, risk-profile, and outcomes of pediatric/congenital catheterization procedures changed in response to the first wave of COVID-19 and after that wave. Methods: A multicenter retrospective observational study was performed using Congenital Cardiac Catheterization Project on Outcomes Registry (C3PO) data to study changes in volume, case mix, and outcomes (high-severity adverse events [HSAEs]) during the first wave of COVID (March 1, 2020, to May 31, 2020) in comparison to the period prior to (January 1, 2019, to February 28, 2020) and after (June 1, 2020, to December 31, 2020) the first wave. Multivariable analyses adjusting for case type, hemodynamic vulnerability, and age group were performed. Hospital responses to the first wave were captured with an electronic study instrument. Results: During the study period, 12,557 cases were performed at 14 C3PO hospitals (with 8% performed during the first wave of COVID and 32% in the postperiod). Center case volumes decreased from a median 32.1 cases/month (IQR: 20.7-49.0 cases/month) before COVID to 22 cases/month (IQR: 13-31 cases/month) during the first wave (P = 0.001). The proportion of cases with risk factors for HSAE increased during the first wave, specifically proportions of infants and neonates (P < 0.001) and subjects with renal insufficiency (P = 0.02), recent cardiac surgery (P < 0.001), and a higher hemodynamic vulnerability score (P = 0.02). The observed HSAE risk did not change significantly (P = 0.13). In multivariable analyses, odds of HSAE during the first wave of COVID (odds ratio: 0.75) appeared to be lower than that before COVID, but the difference was not significant (P = 0.09). Conclusions: Despite increased case-mix complexity, C3PO programs maintained, if not improved, their performance in terms of HSAE. Exploratory analyses of practice changes may inform future harm-reduction efforts.

8.
Commun Med (Lond) ; 2: 3, 2022.
Article in English | MEDLINE | ID: mdl-35603301

ABSTRACT

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

9.
JACC Cardiovasc Interv ; 15(9): 979-988, 2022 05 09.
Article in English | MEDLINE | ID: mdl-35512922

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the accuracy of cardiac magnetic resonance (CMR) in predicting coronary artery (CA) compression during transcatheter pulmonary valve implantation (TPVi). BACKGROUND: TPVi is a widely available option to treat dysfunctional right ventricle (RV)-to-pulmonary artery (PA) conduits, but CA compression is an absolute contraindication. CMR can evaluate coronary anatomy, but its utility in predicting CA compression is not well established. METHODS: After Institutional Review Board approval was obtained, all patients at 9 centers with attempted TPVi in RV-PA conduits and recent CMR (≤12 months) were analyzed. A core laboratory reviewed all CMR studies for the shortest orthogonal distance from a CA to the conduit, the shortest distance from a CA to the most stenotic area of the conduit, and subjective assessment of CA compression risk. RESULTS: Among 231 patients, TPVi was successful in 198 (86%); in 24 (10%), balloon testing precluded implantation (documented CA compression or high risk). Distance to the RV-PA conduit ≤2.1 mm (area under the curve [AUC]: 0.70) and distance to most stenotic area ≤13.1 mm (AUC: 0.69) predicted CA compression. Subjective assessment had the highest AUC (0.78), with 96% negative predictive value. Both distances and qualitative assessment remained independently associated with CA compression when controlling for abnormal coronary anatomy or degree of conduit calcification. CONCLUSIONS: CMR can help predict the risk for CA compression during TPVi in RV-PA conduits but cannot completely exclude CA compression. CMR may assist in patient selection and counseling families prior to TPVi, although balloon testing remains essential.


Subject(s)
Heart Valve Prosthesis Implantation , Pulmonary Valve , Cardiac Catheterization/adverse effects , Coronary Vessels , Heart Valve Prosthesis Implantation/adverse effects , Humans , Magnetic Resonance Spectroscopy , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Retrospective Studies , Treatment Outcome
10.
Cardiol Young ; 32(12): 1952-1956, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35152927

ABSTRACT

BACKGROUND: Recurrent laryngeal nerve injury leading to vocal cord paralysis is a known complication of cardiothoracic surgery. Its occurrence during interventional catheterisation procedures has been documented in case reports, but there have been no studies to determine an incidence. OBJECTIVE: To establish the incidence of left recurrent laryngeal nerve injury leading to vocal cord paralysis after left pulmonary artery stenting, patent ductus arteriosus device closure and the combination of the procedures either consecutively or simultaneously. METHODS: Members of the Congenital Cardiovascular Interventional Study Consortium were asked to perform a retrospective analysis to identify cases of recurrent laryngeal nerve injury after the aforementioned procedures. Twelve institutions participated in the analysis. They also contributed the total number of each procedure performed at their respective institutions for statistical purposes. RESULTS: Of the 1337 patients who underwent left pulmonary artery stent placement, six patients (0.45%) had confirmed vocal cord paralysis. 4001 patients underwent patent ductus arteriosus device closure, and two patients (0.05%) developed left vocal cord paralysis. Patients who underwent both left pulmonary artery stent placement and patent ductus arteriosus device closure had the highest incidence of vocal cord paralysis which occurred in 4 of the 26 patients (15.4%). Overall, 92% of affected patients in our study population had resolution of symptoms. CONCLUSION: Recurrent laryngeal nerve injury is a rare complication of left pulmonary artery stent placement or patent ductus arteriosus device closure. However, the incidence is highest in patients undergoing both procedures either consecutively or simultaneously. Additional research is necessary to determine contributing factors that might reduce the risk of recurrent laryngeal nerve injury.


Subject(s)
Ductus Arteriosus, Patent , Recurrent Laryngeal Nerve Injuries , Vocal Cord Paralysis , Humans , Recurrent Laryngeal Nerve Injuries/etiology , Recurrent Laryngeal Nerve Injuries/complications , Vocal Cord Paralysis/epidemiology , Vocal Cord Paralysis/etiology , Ductus Arteriosus, Patent/epidemiology , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/complications , Incidence , Retrospective Studies , Catheterization/adverse effects
11.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34743224

ABSTRACT

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Subject(s)
Heart Septal Defects, Atrial , Radiation Exposure , Septal Occluder Device , Cardiac Catheterization/methods , Fluoroscopy/methods , Heart Septal Defects, Atrial/surgery , Humans , Quality Improvement , Radiation Dosage , Radiation Exposure/prevention & control , Retrospective Studies , Treatment Outcome
12.
Biomedicines ; 9(5)2021 Apr 27.
Article in English | MEDLINE | ID: mdl-33925558

ABSTRACT

Bioabsorbable materials made from polymeric compounds have been used in many fields of regenerative medicine to promote tissue regeneration. These materials replace autologous tissue and, due to their growth potential, make excellent substitutes for cardiovascular applications in the treatment of congenital heart disease. However, there remains a sizable gap between their theoretical advantages and actual clinical application within pediatric cardiovascular surgery. This review will focus on four areas of regenerative medicine in which bioabsorbable materials have the potential to alleviate the burden where current treatment options have been unable to within the field of pediatric cardiovascular surgery. These four areas include tissue-engineered pulmonary valves, tissue-engineered patches, regenerative medicine options for treatment of pulmonary vein stenosis and tissue-engineered vascular grafts. We will discuss the research and development of biocompatible materials reported to date, the evaluation of materials in vitro, and the results of studies that have progressed to clinical trials.

13.
J Perinatol ; 41(7): 1528-1539, 2021 07.
Article in English | MEDLINE | ID: mdl-33674714

ABSTRACT

Primary pulmonary vein stenosis (PPVS) is an emerging problem among infants. In contrast to acquired disease, PPVS is the development of stenosis in the absence of preceding intervention. While optimal care approaches remain poorly characterized, over the past decade, understanding of potential pathophysiological mechanisms and development of novel therapeutic strategies are increasing. A multidisciplinary team of health care providers was assembled to review the available evidence and provide a common framework for the diagnosis, management, and treatment of PPVS during infancy. To address knowledge gaps, institutional and multi-institutional approaches must be employed to generate knowledge specific to ex-premature infants with PPVS. Within individual institutions, creation of a team comprised of dedicated health care providers from diverse backgrounds is critical to accelerate clinical learning and provide care for infants with PPVS. Multi-institutional collaborations, such as the PVS Network, provide the infrastructure and statistical power to advance knowledge for this rare disease.


Subject(s)
Infant, Premature, Diseases , Pulmonary Veins , Stenosis, Pulmonary Vein , Constriction, Pathologic , Humans , Infant , Infant, Newborn , Infant, Premature , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/therapy
14.
Cardiol Young ; 31(9): 1407-1411, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33597057

ABSTRACT

BACKGROUND: Three-dimensional printing is increasingly utilised for congenital heart defect procedural planning. CT or MR datasets are typically used for printing, but similar datasets can be obtained from three-dimensional rotational angiography. We sought to assess the feasibility and accuracy of printing three-dimensional models of CHD from rotational angiography datasets. METHODS: Retrospective review of CHD catheterisations using rotational angiography was performed, and patient and procedural details were collected. Imaging data from rotational angiography were segmented, cleaned, and printed with polylactic acid on a Dremel® 3D Idea Builder (Dremel, Mount Prospect, IL, USA). Printing time and materials' costs were captured. CT scans of printed models were compared objectively to the original virtual models. Two independent, non-interventional paediatric cardiologists provided subjective ratings of the quality and accuracy of the printed models. RESULTS: Rotational angiography data from 15 catheterisations on vascular structures were printed. Median print time was 3.83 hours, and material costs were $2.84. The CT scans of the printed models highly matched with the original digital models (root mean square for Hausdorff distance 0.013 ± 0.003 mesh units). Independent reviewers correctly described 80 and 87% of the models (p = 0.334) and reported high quality and accuracy (5 versus 5, p = NS; κ = 0.615). CONCLUSION: Imaging data from rotational angiography can be converted into accurate three-dimensional-printed models of CHD. The cost of printing the models was negligible, but the print time was prohibitive for real-time use. As the speed of three-dimensional printing technology increases, novel future applications may allow for printing patient-specific devices based on rotational angiography datasets.


Subject(s)
Heart Defects, Congenital , Printing, Three-Dimensional , Angiography , Cardiac Catheterization , Child , Heart Defects, Congenital/diagnostic imaging , Humans , Models, Anatomic , Retrospective Studies
15.
Circ Cardiovasc Interv ; 14(2): e009399, 2021 02.
Article in English | MEDLINE | ID: mdl-33544625

ABSTRACT

BACKGROUND: Stent implantation (SI) is more effective than balloon angioplasty for the treatment of coarctation of the aorta (CoA). Due to technical factors, balloon angioplasty is more commonly performed in small patients. We sought to evaluate outcomes of percutaneous adult sized SI for the treatment of CoA in small patients. METHODS: A single-center retrospective review of all patients ≤20 kg who underwent percutaneous adult sized SI for native or recurrent CoA from 2004 to 2015 was performed. RESULTS: Thirty-nine patients (20 patients ≤10 kg) were identified, with 28 (71.8%) having recurrent CoA and 22 (56.4%) previously failed balloon angioplasty. At the time of SI, the median (range) patient age and weight were 1.1 (0.3-7.9) years and 10 (5.5-20.4) kg, respectively. SI resulted in significant improvements in the median gradient (26 mm Hg [interquartile range (IQR), 18-42] to 0 mm Hg [IQR, 0-2]; P< 0.05) and median minimum diameter (3.6 mm [IQR, 2.4-4.8] to 7.7 mm [IQR, 6.5-9.4]; P<0.05). Seven patients (18%) had procedural adverse events. Twenty-seven (69%) patients underwent elective reintervention at a median time of 49.3 (IQR, 26.5-63.2) months from SI, with 8 (21%) stents requiring repeat SI for stent fracture. Over a median follow-up of 67.2 (IQR, 33.8-116.1) months, 25 patients (69%) were without hypertension or blood pressure gradient. Three (11%) patients developed femoral arterial occlusion. CONCLUSIONS: Adult sized SI is an alternative to surgical intervention for small patients with CoA. SI carries a risk of access-related complications, which may improve with the development of lower profile stents with adult sized maximum diameters.


Subject(s)
Aortic Coarctation , Adult , Angioplasty, Balloon/adverse effects , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/surgery , Child , Follow-Up Studies , Humans , Retrospective Studies , Stents , Treatment Outcome
16.
Sci Transl Med ; 12(537)2020 04 01.
Article in English | MEDLINE | ID: mdl-32238576

ABSTRACT

We developed a tissue-engineered vascular graft (TEVG) for use in children and present results of a U.S. Food and Drug Administration (FDA)-approved clinical trial evaluating this graft in patients with single-ventricle cardiac anomalies. The TEVG was used as a Fontan conduit to connect the inferior vena cava and pulmonary artery, but a high incidence of graft narrowing manifested within the first 6 months, which was treated successfully with angioplasty. To elucidate mechanisms underlying this early stenosis, we used a data-informed, computational model to perform in silico parametric studies of TEVG development. The simulations predicted early stenosis as observed in our clinical trial but suggested further that such narrowing could reverse spontaneously through an inflammation-driven, mechano-mediated mechanism. We tested this unexpected, model-generated hypothesis by implanting TEVGs in an ovine inferior vena cava interposition graft model, which confirmed the prediction that TEVG stenosis resolved spontaneously and was typically well tolerated. These findings have important implications for our translational research because they suggest that angioplasty may be safely avoided in patients with asymptomatic early stenosis, although there will remain a need for appropriate medical monitoring. The simulations further predicted that the degree of reversible narrowing can be mitigated by altering the scaffold design to attenuate early inflammation and increase mechano-sensing by the synthetic cells, thus suggesting a new paradigm for optimizing next-generation TEVGs. We submit that there is considerable translational advantage to combined computational-experimental studies when designing cutting-edge technologies and their clinical management.


Subject(s)
Blood Vessel Prosthesis , Constriction, Pathologic , Tissue Engineering , Animals , Child , Constriction, Pathologic/therapy , Humans , Sheep , United States
17.
World J Pediatr Congenit Heart Surg ; 11(3): 295-303, 2020 05.
Article in English | MEDLINE | ID: mdl-32294003

ABSTRACT

OBJECTIVES: We aimed to evaluate the utility of computed tomography angiography (CTA) for coronary compression (CC) prediction in patients with congenital heart disease undergoing balloon-expandable transcatheter pulmonary valve replacement (TPVR). BACKGROUND: Coronary compression is a serious complication of TPVR, but the value of preprocedural CTAs to assess CC risk is largely unexplored. METHODS: In all, 586 patients underwent TPVR between January 2009 and July 2018. Adults with a pre-TPVR CTA and children with a CTA performed less than one year prior to TPVR were included. Patients with poor CTA image quality or with aborted cases due to reasons other than CC were excluded. Sixty-six patients were finally included. Cardiac anatomy was assessed via multiplanar reconstruction of CTAs. RESULTS: Coronary compression occurred in 9 (14%) of the 66 patients who underwent TPVR. Most CC cases (seven of nine) occurred in patients with conduits. Proximity of the right ventricular outflow tract (RVOT) landing zone to the coronary arteries and to the chest wall was a significant risk factor for compression (P < .001 and P = .019, respectively). Compression risk increased significantly if patients had an RVOT to coronary artery distance of ≤3 mm (P < .001) and an RVOT to chest wall distance of ≤8 mm (P = .026). Anomalous course of coronary arteries was another significant univariate risk factor (P = .003). CONCLUSIONS: Right ventricular outflow tract landing zone distance of ≤3 mm to a coronary artery, landing zone distance of ≤8 mm to the chest wall, and anomalous coronary arteries are associated with increased CC risk. Electrocardiogram gating may not be necessary if coronary arteries are opacified on CTAs. Larger studies are needed to explore and confirm these coronary artery compression risk factors.


Subject(s)
Cardiac Catheterization , Computed Tomography Angiography , Coronary Vessels/surgery , Heart Valve Prosthesis Implantation , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve/surgery , Adolescent , Adult , Aged , Cardiac Surgical Procedures/adverse effects , Child , Female , Heart Defects, Congenital/surgery , Humans , Male , Middle Aged , Patients , Retrospective Studies , Treatment Outcome , Young Adult
18.
J Am Coll Cardiol ; 75(4): 363-376, 2020 02 04.
Article in English | MEDLINE | ID: mdl-32000947

ABSTRACT

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) is associated with a risk of procedural serious adverse events (SAE) and exposure to ionizing radiation. OBJECTIVES: The purpose of this study was to define the risk of, and associations with, SAE and high-dose radiation exposure using large-scale registry data. METHODS: The analysis of the multicenter C3PO-QI registry was limited to patients who underwent TPVR from January 1, 2014, to December 31, 2016. SAE were defined as the occurrence of ≥1 moderate, major, or catastrophic events. Radiation dose was reported as dose area product adjusted for weight. Associations with outcome measures were explored in univariate and multivariable analyses. RESULTS: A total of 530 patients (59% male) underwent TPVR at a median age of 18.3 years (interquartile range [IQR]: 12.9 to 27.3 years) and weight of 58 kg (IQR: 43 to 77 kg) at 14 centers. Implant substrate included homograft (41%), bioprosthesis (30%), native right ventricular outflow tract (RVOT) (27%) and other (2%). TPVR indications were pulmonary insufficiency (28%), stenosis (23%), and mixed (49%). AE and SAE occurred in 26% and 13% of cases, respectively, including 1 mortality. SAE were more frequent in homograft conduit than other RVOT substrates, although SAE type and severity differed between implant substrates. Median radiation dose was 198 µGy·m2/kg (IQR: 94 to 350 µGy·m2/kg). Higher radiation dose was associated with older age, greater RVOT obstruction, and concomitant interventions (p < 0.001). During a median follow-up duration of 1 year, 13.3% underwent catheterization, surgery, or both, unrelated to infection. Younger age, smaller size, and hemodynamic and anatomic factors indicative of greater RVOT obstruction were associated with TPV reintervention. CONCLUSIONS: The incidence of SAE during TPVR in the C3PO-QI registry is high, but mortality is uncommon. Radiation dose is greater than for other congenital interventions and is associated with patient and procedural factors. Reintervention is common during early follow-up.


Subject(s)
Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve/surgery , Radiation Exposure , Radiation, Ionizing , Adolescent , Adult , Cardiac Catheterization/adverse effects , Cardiac Surgical Procedures/adverse effects , Catheterization , Child , Endocarditis/surgery , Female , Heart Defects, Congenital/surgery , Humans , Incidence , Male , Multivariate Analysis , Registries , Risk , Tetralogy of Fallot/surgery , Young Adult
19.
Catheter Cardiovasc Interv ; 95(2): 270-279, 2020 02.
Article in English | MEDLINE | ID: mdl-31609082

ABSTRACT

OBJECTIVE: We describe the technical considerations of transcatheter implantation of the CardioMEMS™ HF System (Abbott, Abbott Park, IL) in adult patients with complex palliated congenital heart disease (CHD) and advanced heart failure (HF). BACKGROUND: Ambulatory pulmonary artery (PA) pressure monitoring with implantable hemodynamic monitors (IHMs) has been shown to reduce HF-related hospital admissions in non-CHD populations. HF is a common late cardiovascular complication in adult CHD necessitating better understanding of IHM application in this population. METHODS: We analyzed adults with complex CHD and advanced HF who were referred for CardioMEMS™ device implantation (2015-2018). Feasibility of device implantation, defined by successful device implantation and calibration, and procedural outcomes were evaluated. RESULTS: CardioMEMS™ was successfully implanted in all 14 adults (35.5 ± 9.2 years old, 72 ± 12 kg) with complex CHD (single ventricle/Fontan, n = 8 [57%]; d-transposition of the great arteries/atrial switch, n = 6 [43%]). The device was delivered via femoral venous access in 13 (93%) patients and implanted in the left PA in 12 (86%). A long sheath was used in 8 (57%) patients, including 5/6 with an atrial switch operation. There was one device migration that did not require retrieval. CONCLUSIONS: Transcatheter implantation of an IHM is feasible in select complex adult CHD patients with advanced HF. Further studies evaluating integration of ambulatory hemodynamics and the impact on clinical care are needed. This technology has the potential to improve medical management of advanced HF in patients with Fontan and atrial switch physiologies and provide new insights into their ambulatory hemodynamics.


Subject(s)
Arterial Pressure , Blood Pressure Monitoring, Ambulatory/instrumentation , Blood Pressure Monitors , Heart Defects, Congenital/therapy , Heart Failure/diagnosis , Palliative Care , Pulmonary Artery/physiopathology , Remote Sensing Technology/instrumentation , Adult , Female , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/physiopathology , Heart Failure/etiology , Heart Failure/physiopathology , Heart Failure/therapy , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , Young Adult
20.
J Pediatr ; 212: 144-150.e3, 2019 09.
Article in English | MEDLINE | ID: mdl-31262530

ABSTRACT

OBJECTIVES: To describe longer term outcomes for infants <6 kg undergoing percutaneous occlusion of the patent ductus arteriosus (PDA). STUDY DESIGN: This was a retrospective cohort study of infants <6 kg who underwent isolated percutaneous closure of the PDA at a single, tertiary center (2003-2017). Cardiopulmonary outcomes and device-related complications (eg, left pulmonary artery obstruction) were examined for differences across weight thresholds (very low weight, <3 kg; low weight, 3-<6 kg). We assessed composite measures of respiratory status during and beyond the initial hospitalization using linear mixed effects models. RESULTS: In this cohort of lower weight infants, 92 of 106 percutaneous occlusion procedures were successful. Median age and weight at procedure were 3.0 months (range, 0.5-11.1 months) and 3.7 kg (range, 1.4-5.9 kg), respectively. Among infants with pulmonary artery obstruction on initial postprocedural echocardiograms (n = 20 [22%]), obstruction persisted through hospital discharge in 3 infants. No measured variables were associated with device-related complications. Rates of oxygenation failure (28% vs 8%; P < .01) and decreased left ventricular systolic function (29% vs 5%; P < .01) were higher among very low weight than low weight infants. Pulmonary scores decreased (indicating improved respiratory status) following percutaneous PDA closure. CONCLUSIONS: Percutaneous PDA occlusion among lower weight infants is associated with potential longer term improvements in respiratory health. Risks of device-related complications and adverse cardiopulmonary outcomes, particularly among very low weight infants, underscore the need for continued device modification. Before widespread use, clinical trials comparing percutaneous occlusion vs alternative treatments are needed.


Subject(s)
Ductus Arteriosus, Patent/therapy , Therapeutic Occlusion , Cohort Studies , Female , Follow-Up Studies , Humans , Infant , Infant, Low Birth Weight , Infant, Newborn , Male , Retrospective Studies , Therapeutic Occlusion/methods , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL