Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Bioanalysis ; 14(15): 1067-1079, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36125040

ABSTRACT

Background: Respiratory syncytial virus (RSV) vaccine is an unmet medical need. The virus reduction neutralization test (VRNT) was developed to replace the LI-COR microneutralization assay to measure RSV neutralization titers. Methods: A bridging study using selected V171 phase I samples and calibration studies using the WHO international standard antiserum to RSV were performed to compare VRNT and LI-COR. Results: From the bridging study, we showed good concordance between VRNT and LI-COR titers, and similar post-/prevaccination titer ratios. From the calibration studies, we can convert VRNT and LI-COR titers into similar IU/ml. Conclusion: The VRNT and LI-COR microneutralization assay correlate well and the titers can be standardized as similar IU/ml, enabling direct comparison of titers from different assays.


Subject(s)
Respiratory Syncytial Viruses , Vaccines , Antibodies, Neutralizing , Calibration , Neutralization Tests , World Health Organization
2.
J Immunol Methods ; 494: 113054, 2021 07.
Article in English | MEDLINE | ID: mdl-33845088

ABSTRACT

Respiratory syncytial virus (RSV) is a common pathogen causing severe respiratory illness in infants and elder adults. The development of an effective RSV vaccine is an important unmet medical need and an area of active research. The traditional method for testing neutralizing antibodies against RSV in clinical trials is the plaque reduction neutralization test (PRNT), which uses 24-well plates and needs several days post infection to develop viral plaques. In this study, we have developed a virus reduction neutralization test (VRNT), which allows the number of RSV infected cells to be automatically counted by an imaging cytometer at one day post infection in 96-well plates. VRNT was found robust to cell seeding density, detection antibody concentration, virus input and infection time. By testing twenty human sera, we have shown good correlation between VRNT50 and PRNT50 titers for multiple RSV strains: A2, Long and 18537 (serotype B). To understand the VRNT performance, eight human serum samples with high, medium and low neutralization titers were selected for VRNT qualification. We have demonstrated that VRNT had good specificity, precision, linearity and relative accuracy. In conclusion, VRNT is a better alternative to PRNT in serum neutralization test for RSV vaccine candidates.


Subject(s)
Neutralization Tests/methods , Respiratory Syncytial Virus Infections/diagnosis , Respiratory Syncytial Virus Vaccines/immunology , Respiratory Syncytial Viruses/physiology , Aged, 80 and over , Animals , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , Chlorocebus aethiops , Diagnostic Imaging , High-Throughput Screening Assays , Humans , Infant , Infant, Newborn , Miniaturization , Reproducibility of Results , Sensitivity and Specificity , Time Factors , Vero Cells , Viral Plaque Assay
3.
Clin Infect Dis ; 69(10): 1724-1730, 2019 10 30.
Article in English | MEDLINE | ID: mdl-30668657

ABSTRACT

BACKGROUND: Early secretory antigenic target-6 (ESAT-6) is an immunodominant Mycobacterium tuberculosis (M.tb) antigen included in novel vaccines against tuberculosis (TB) and in interferon-gamma (IFN-γ) release assays (IGRAs). Therefore, the availability of an ESAT-6-free IGRA is essential to determine M.tb infection status following vaccination with ESAT-6-containing vaccines. We aimed to qualify a recently developed ESAT-6-free IGRA and to assess its diagnostic performance in comparison to QuantiFERON-TB Gold In-tube (QFT). METHODS: Participants with different levels of M.tb exposure and TB disease were enrolled to determine the ESAT-6-free IGRA cutoff, test assay performance in independent cohorts compared to standard QFT, and perform a technical qualification of antigen-coated blood collection tubes. RESULTS: ESAT-6-free IGRA antigen recognition was evaluated in QFT-positive and QFT-negative South African adolescents. The ESAT-6-free IGRA cutoff was established at 0.61 IU/mL, based on receiver operating characteristic analysis in M.tb-unexposed controls and microbiologically confirmed pulmonary TB patients. In an independent cohort of healthy adolescents, levels of IFN-γ released in QFT and ESAT-6-free IGRA were highly correlated (P < .0001, r = 0.83) and yielded comparable positivity rates, 41.5% and 43.5%, respectively, with 91% concordance between the tests (kappa = 0.82; 95% confidence interval, 0.74-0.90; McNemar test P = .48). ESAT-6-free IGRA blood collection tubes had acceptable lot-to-lot variability, precision, and stability. CONCLUSIONS: The novel ESAT-6-free IGRA had diagnostic accuracy comparable to QFT and is suitable for use in clinical trials to assess efficacy of candidate TB vaccines to prevent established M.tb infection.


Subject(s)
Interferon-gamma Release Tests , Interferon-gamma/blood , Reagent Kits, Diagnostic , Tuberculosis/diagnosis , Adolescent , Antigens, Bacterial/immunology , Bacterial Proteins/immunology , Child , Cohort Studies , Female , Humans , Male , Mycobacterium tuberculosis/immunology , ROC Curve , Reproducibility of Results , Tuberculosis/blood , Tuberculosis/immunology , Tuberculosis Vaccines/administration & dosage , Tuberculosis Vaccines/immunology
4.
Am J Trop Med Hyg ; 99(6): 1430-1439, 2018 12.
Article in English | MEDLINE | ID: mdl-30350775

ABSTRACT

Vaccine immunogenicity and clinical efficacy are often assessed by the measure of serum-neutralizing antibodies. The present gold standard for detecting neutralizing antibodies against many viruses, including dengue, is the plaque/focus reduction neutralization test (P/FRNT). The FRNT is a cell-based assay that inherits high variability, resulting in poor precision and has lengthy turnaround times. The virus reduction neutralization test (VRNT) is a high-throughput alternative to the standard low-throughput and laborious FRNT. The VRNT is similar to FRNT using unaltered wild-type virus and immunostaining, yet uses imaging cytometry to count virus-infected cells 1 day post-infection, reducing assay time and increasing overall throughput 15-fold. In addition, the VRNT has lowered variability relative to FRNT, which may be explained in part by the observation that foci overlap alters foci count and titer over time, in the FRNT. The ability to count one infected cell, rather than waiting for overlapping foci to form, ensures accuracy and contributes to the precision (7-25% coefficient of variation) and sensitivity of the VRNT. Results from 81 clinical samples tested in the VRNT and FRNT show a clear positive relationship. During sample testing, a 96-well plate edge effect was noted and the elimination of this edge effect was achieved by a simple plate seeding technique. The VRNT is an improvement to the current neutralization assays for its shortened assay time, increased precision and throughput, and an alternative to the P/FRNT.


Subject(s)
Antibodies, Neutralizing/analysis , Antibodies, Viral/analysis , Dengue Virus/immunology , High-Throughput Screening Assays/standards , Molecular Imaging/methods , Neutralization Tests/standards , Single-Cell Analysis/methods , Animals , Anthraquinones/chemistry , Chlorocebus aethiops , Dengue/immunology , Dengue/prevention & control , Dengue/virology , Dengue Vaccines/analysis , Dengue Virus/isolation & purification , Fluorescent Dyes/chemistry , Humans , Reproducibility of Results , Sensitivity and Specificity , Vero Cells , Viral Load , Viral Plaque Assay
6.
Nat Commun ; 7: 11290, 2016 04 12.
Article in English | MEDLINE | ID: mdl-27068708

ABSTRACT

Vaccines to protect against tuberculosis (TB) are urgently needed. We performed a case-control analysis to identify immune correlates of TB disease risk in Bacille Calmette-Guerin (BCG) immunized infants from the MVA85A efficacy trial. Among 53 TB case infants and 205 matched controls, the frequency of activated HLA-DR(+) CD4(+) T cells associates with increased TB disease risk (OR=1.828, 95% CI=1.25-2.68, P=0.002, FDR=0.04, conditional logistic regression). In an independent study of Mycobacterium tuberculosis-infected adolescents, activated HLA-DR(+) CD4(+) T cells also associate with increased TB disease risk (OR=1.387, 95% CI=1.068-1.801, P=0.014, conditional logistic regression). In infants, BCG-specific T cells secreting IFN-γ associate with reduced risk of TB (OR=0.502, 95% CI=0.29-0.86, P=0.013, FDR=0.14). The causes and impact of T-cell activation on disease risk should be considered when designing and testing TB vaccine candidates for these populations.


Subject(s)
BCG Vaccine/immunology , CD4-Positive T-Lymphocytes/immunology , Lymphocyte Activation/immunology , Vaccination , Adolescent , Antibody Formation/immunology , Case-Control Studies , Cohort Studies , HLA-DR Antigens/immunology , Humans , Immunity , Immunoglobulin G/immunology , Infant , Logistic Models , Mycobacterium tuberculosis/immunology , Placebos , Risk Factors , Time Factors , Tuberculosis/blood , Tuberculosis/immunology , Tuberculosis Vaccines/immunology , Vaccines, DNA
SELECTION OF CITATIONS
SEARCH DETAIL
...