Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Cardiovasc Dis ; 111(8-9): 518-527, 2018.
Article in English | MEDLINE | ID: mdl-29439881

ABSTRACT

BACKGROUND: The frequency of paradoxical low-gradient severe aortic stenosis (AS) varies widely across studies. The impact of misalignment of aortic flow and pressure recovery phenomenon on the frequency of low-gradient severe AS with preserved left ventricular ejection fraction (LVEF) has not been evaluated in prospective studies. AIMS: To investigate prospectively the impact of aortic flow misalignment by Doppler and lack of pressure recovery phenomenon correction on the frequency of low-gradient (LG) severe aortic stenosis (AS) with preserved LVEF. METHODS: Aortic jet velocities and mean pressure gradient (MPG) were obtained by interrogating all windows in 68 consecutive patients with normal LVEF and severe AS (aortic valve area [AVA] ≤1cm2) on the basis of the apical imaging window alone (two-dimensional [2D] apical approach). Patients were classified as having LG or high-gradient (HG) AS according to MPG <40mmHg or ≥40mmHg, and normal flow (NF) or low flow (LF) according to stroke volume index >35mL/m2 or ≤35mL/m2, on the basis of the 2D apical approach, the multiview approach (multiple windows evaluation) and AVA corrected for pressure recovery. RESULTS: The proportion of LG severe AS was 57% using the 2D apical approach alone. After the multiview approach and correction for pressure recovery, the proportion of LG severe AS decreased from 57% to 13% (LF-LG severe AS decreased from 23% to 3%; NF-LG severe AS decreased from 34% to 10%). As a result, 25% of patients were reclassified as having HG severe AS (AVA ≤1cm2 and MPG ≥40mmHg) and 19% as having moderate AS. Hence, 77% of patients initially diagnosed with LG severe AS did not have "true" LG severe AS when the multiview approach and the pressure recovery phenomenon correction were used. CONCLUSIONS: Aortic flow misevaluation, resulting from lack of use of multiple windows evaluation and pressure recovery phenomenon correction, accounts for a large proportion of incorrectly graded AS and considerable overestimation of the frequency of LG severe AS with preserved LVEF.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Echocardiography, Doppler , Hemodynamics , Stroke Volume , Ventricular Function, Left , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/physiopathology , Female , France/epidemiology , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Reproducibility of Results , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL
...