Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
Add more filters










Publication year range
1.
Rev Sci Instrum ; 92(3): 033524, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33820017

ABSTRACT

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

2.
Rev Sci Instrum ; 90(7): 073504, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31370451

ABSTRACT

Negative-ion neutral-beam injection (NNBI) is an important source of heating and current drive for next-step fusion devices where the injected energy can range from hundreds of keV to 1 MeV. Few diagnostics are suitable for phase-space resolved measurements of fast ions with energy in excess of 100 keV. A study to assess the feasibility of fast-ion deuterium-alpha (FIDA) spectroscopy to diagnose high-energy ions produced by NNBI is presented. Case studies with the Large Helical Device (LHD) and JT-60SA illustrate possible solutions for the measurement. The distribution function of fast ions produced by NNBI is calculated for both devices, and the FIDA spectrum is predicted by synthetic diagnostic simulation. Results with 180 keV NNBI in LHD show that, with a judicious choice of viewing geometry, the FIDA intensity is comparable to that obtained with the existing FIDA system. The measurement is more challenging with the 500 keV NNBI in JT-60SA. Simulations predict the FIDA intensity to be about 1% of the background bremsstrahlung, which is small compared to existing FIDA implementations with positive neutral-beam injection where signal levels are an order of magnitude larger. The sampling time required to extract the small FIDA signal is determined using a probabilistic approach. Results indicate that long averaging periods, from ones to tens of seconds, are needed to resolve the FIDA signal in JT-60SA. These long averaging times are suitable in long-pulse (∼100 s), steady-state devices like JT-60SA where an important measurement objective is the spatial profile of the slowing-down distribution of fast ions.

3.
Rev Sci Instrum ; 89(10): 10B105, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399752

ABSTRACT

In order to improve both the density and particularly the temporal resolution beyond previous dispersion interferometers (DIs), a heterodyne technique based on an acousto-optic (AO) cell has been added to the DI. A 40 MHz drive frequency for the AO cell allows density fluctuation measurements into the MHz range. A CO2 laser-based heterodyne DI (HDI) installed on DIII-D has demonstrated that the HDI is capable of tracking the density evolution throughout DIII-D discharges, including disruption events and other rapid transient phenomena. The data also show good agreement with independent density measurements obtained with the existing DIII-D two-color interferometer. The HDI line-integrated density resolution sampled over a 1 s interval is ∼9 × 1017 m-2. Density fluctuations induced by MHD instabilities are also successfully measured by the HDI.

4.
Rev Sci Instrum ; 89(10): 10B102, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399936

ABSTRACT

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 µm and 5.22 µm using a CO2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 µm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. The corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 1018 m-2, and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 1019 Tm-2. Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

5.
Rev Sci Instrum ; 87(11): 11E508, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910482

ABSTRACT

A design to extend the unique divertor Thomson scattering system on DIII-D to allow measurements of electron temperature and density in high triangularity plasmas is presented. Access to this region is selectable on a shot-by-shot basis by redirecting the laser beam of the existing divertor Thomson system inboard - beneath the lower floor using a moveable, high-damage threshold, in-vacuum mirror - and then redirecting again vertically. The currently measured divertor region remains available with this mirror retracted. Scattered light is collected from viewchords near the divertor floor using in-vacuum, high temperature optical elements and relayed through the port window, before being coupled into optical fiber bundles. At higher elevations from the floor, measurements are made by dynamically re-focusing the existing divertor system collection optics. Nd:YAG laser timing, analysis of the scattered light spectrum via polychromators, data acquisition, and calibration are all handled by existing systems or methods of the current multi-pulse Thomson scattering system. Existing filtered polychromators with 7 spectral channels are employed to provide maximum measurement breadth (Te in the range of 0.5 eV-2 keV, ne in the range of 5 × 1018-1 × 1021 m3) for both low Te in detachment and high Te measurement up beyond the separatrix.

6.
Rev Sci Instrum ; 87(12): 123502, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28040946

ABSTRACT

A heterodyne detection scheme is combined with a 10.59 µm CO2 laser dispersion interferometer for the first time to allow large bandwidth measurements in the 10-100 MHz range. The approach employed utilizes a 40 MHz acousto-optic cell operating on the frequency doubled CO2 beam which is obtained using a high 2nd harmonic conversion efficiency orientation patterned gallium arsenide crystal. The measured standard deviation of the line integrated electron density equivalent phase resolution obtained with digital phase demodulation technique, is 4 × 1017 m-2. Air flow was found to significantly affect the baseline of the phase signal, which an optical table cover was able to reduce considerably. The heterodyne dispersion interferometer (DI) approach is found to be robustly insensitive to motion, with measured phase shifts below baseline drifts even in the presence of several centimeters of retroreflector induced path length variations. Plasma induced dispersion was simulated with a wedged ZnSe plate and the measured DI phase shifts are consistent with expectations.

7.
Rev Sci Instrum ; 85(8): 083503, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25173265

ABSTRACT

The DIII-D tokamak magnetic diagnostic system [E. J. Strait, Rev. Sci. Instrum. 77, 023502 (2006)] has been upgraded to significantly expand the measurement of the plasma response to intrinsic and applied non-axisymmetric "3D" fields. The placement and design of 101 additional sensors allow resolution of toroidal mode numbers 1 ≤ n ≤ 3, and poloidal wavelengths smaller than MARS-F, IPEC, and VMEC magnetohydrodynamic model predictions. Small 3D perturbations, relative to the equilibrium field (10(-5) < δB/B0 < 10(-4)), require sub-millimeter fabrication and installation tolerances. This high precision is achieved using electrical discharge machined components, and alignment techniques employing rotary laser levels and a coordinate measurement machine. A 16-bit data acquisition system is used in conjunction with analog signal-processing to recover non-axisymmetric perturbations. Co-located radial and poloidal field measurements allow up to 14.2 cm spatial resolution of poloidal structures (plasma poloidal circumference is ~500 cm). The function of the new system is verified by comparing the rotating tearing mode structure, measured by 14 BP fluctuation sensors, with that measured by the upgraded B(R) saddle loop sensors after the mode locks to the vessel wall. The result is a nearly identical 2/1 helical eigenstructure in both cases.

8.
Rev Sci Instrum ; 84(9): 093502, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24089824

ABSTRACT

A dispersion interferometer based on the second-harmonic generation of a carbon dioxide laser in orientation-patterned gallium arsenide has been developed for measuring electron density in plasmas. The interferometer includes two nonlinear optical crystals placed on opposite sides of the plasma. This instrument has been used to measure electron line densities in a pulsed radio-frequency generated argon plasma. A simple phase-extraction technique based on combining measurements from two successive pulses of the plasma has been used. The noise-equivalent line density was measured to be 1.7 × 10(17) m(-2) in a detection bandwidth of 950 kHz. One of the orientation-patterned crystals produced 13 mW of peak power at the second-harmonic wavelength from a carbon dioxide laser with 13 W of peak power. Two crystals arranged sequentially produced 58 mW of peak power at the second-harmonic wavelength from a carbon dioxide laser with 37 W of peak power.

9.
Rev Sci Instrum ; 84(4): 043501, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23635190

ABSTRACT

One of the systems planned for the measurement of electron density in ITER is a multi-channel tangentially viewing combined interferometer-polarimeter (TIP). This work discusses the current status of the design, including a preliminary optical table layout, calibration options, error sources, and performance projections based on a CO2/CO laser system. In the current design, two-color interferometry is carried out at 10.59 µm and 5.42 µm and a separate polarimetry measurement of the plasma induced Faraday effect, utilizing the rotating wave technique, is made at 10.59 µm. The inclusion of polarimetry provides an independent measure of the electron density and can also be used to correct the conventional two-color interferometer for fringe skips at all densities, up to and beyond the Greenwald limit. The system features five chords with independent first mirrors to reduce risks associated with deposition, erosion, etc., and a common first wall hole to minimize penetration sizes. Simulations of performance for a projected ITER baseline discharge show the diagnostic will function as well as, or better than, comparable existing systems for feedback density control. Calculations also show that finite temperature effects will be significant in ITER even for moderate temperature plasmas and can lead to a significant underestimate of electron density. A secondary role TIP will fulfill is that of a density fluctuation diagnostic; using a toroidal Alfvén eigenmode as an example, simulations show TIP will be extremely robust in this capacity and potentially able to resolve coherent mode fluctuations with perturbed densities as low as δn∕n ≈ 10(-5).

10.
Rev Sci Instrum ; 83(10): 10D701, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126875

ABSTRACT

The quality of plasma produced in a magnetic confinement fusion device is influenced to a large extent by the neutral gas surrounding the plasma. The plasma is fueled by the ionization of neutrals, and charge exchange interactions between edge neutrals and plasma ions are a sink of energy and momentum. Here we describe a diagnostic capable of measuring the spatial distribution of neutral gas in a magnetically confined fusion plasma. A high intensity (5 MW/cm(2)), narrow bandwidth (0.1 cm(-1)) laser is injected into a hydrogen plasma to excite the Lyman ß transition via the simultaneous absorption of two 205 nm photons. The absorption rate, determined by measurement of subsequent Balmer α emission, is proportional to the number of particles with a given velocity. Calibration is performed in situ by filling the chamber to a known pressure of neutral krypton and exciting a transition close in wavelength to that used in hydrogen. We present details of the calibration procedure, including a technique for identifying saturation broadening, measurements of the neutral density profile in a hydrogen helicon plasma, and discuss the application of the diagnostic to plasmas in the DIII-D tokamak.

11.
Rev Sci Instrum ; 83(10): 10D710, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126884

ABSTRACT

This paper describes a generally applicable technique for simultaneously measuring offset and gain of 64 analog fiber optic data links used for the DIII-D fixed Langmuir probes by embedding a reference voltage waveform in the optical transmitted signal before every tokamak shot. The calibrated data channels allow calibration of the power supply control fiber optic links as well. The array of fiber optic links and the embedded calibration system described here makes possible the use of superior modern data acquisition electronics in the control room.

12.
Rev Sci Instrum ; 83(10): 10D723, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126897

ABSTRACT

A new pair of in situ reciprocating Mach probes termed swing probes has been deployed on the DIII-D centerpost for the 2012 experimental campaign. When not deployed, the entire assembly is housed in a <5 cm space underneath the centerpost tiles. This design is unique in that the probe swings vertically through the edge plasma, taking measurements along a 180° arc with a 20 cm radius. The motion is powered by actuator coils that interact with the tokamak's magnetic field. Two electrodes maintain a Mach-pair orientation throughout the swing and provide measurements of saturation current, electron temperature, and parallel flow speeds up to the separatrix.

13.
Rev Sci Instrum ; 83(10): 10E343, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23127000

ABSTRACT

Validation of models of pedestal structure is an important part of predicting pedestal height and performance in future tokamaks. The Thomson scattering diagnostic at DIII-D has been upgraded in support of validating these models. Spatial and temporal resolution, as well as signal to noise ratio, have all been specifically enhanced in the pedestal region. This region is now diagnosed by 20 view-chords with a spacing of 6 mm and a scattering length of just under 5 mm sampled at a nominal rate of 250 Hz. When mapped to the outboard midplane, this corresponds to ~3 mm spacing. These measurements are being used to test critical gradient models, in which pedestal gradients increase in time until a threshold is reached. This paper will describe the specifications of the upgrade and present initial results of the system.

14.
Rev Sci Instrum ; 81(10): 10D928, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21033956

ABSTRACT

A new electron cyclotron emission imaging diagnostic has been commissioned on the DIII-D tokamak. Dual detector arrays provide simultaneous two-dimensional images of T(e) fluctuations over radially distinct and reconfigurable regions, each with both vertical and radial zoom capability. A total of 320 (20 vertical×16 radial) channels are available. First data from this diagnostic demonstrate the acquisition of coherent electron temperature fluctuations as low as 0.1% with excellent clarity and spatial resolution. Details of the diagnostic features and capabilities are presented.

15.
Rev Sci Instrum ; 81(10): 10E528, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21034056

ABSTRACT

This article describes the results of spatial heterodyne Doppler "coherence imaging" of carbon ion flows in the divertor region of the DIII-D tokamak. Spatially encoded interferometric projections of doubly ionized carbon emission at 465 nm have been demodulated and tomographically inverted to obtain the spatial distribution of the carbon ion parallel flow and emissivity. The operating principles of the new instruments are described, and the link between measured properties and line integrals of the flow field are established. An iterative simultaneous arithmetic reconstruction procedure is applied to invert the interferometric phase shift projections, and the reconstructed parallel flow field amplitudes are found to be in reasonable agreement with UEDGE modeling.

16.
Rev Sci Instrum ; 79(10): 10E719, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044536

ABSTRACT

A tangential viewing, 10.59 microm CO(2) laser polarimeter for electron density measurements based on plasma induced Faraday rotation has been installed on DIII-D. The system uses colinear right- and left-hand circularly polarized beams with a difference frequency of 40 MHz to generate the necessary signal for heterodyne phase detection. The high-resolution phase information required to adequately resolve degree level polarization rotation is obtained using an all-digital "real-time" phase demodulation scheme based on modern digital signal processing techniques. Initial application of the system to DIII-D disruption mitigation experiments utilizing "massive gas jet" injection exhibits reliable operation and excellent agreement with CO(2) interferometer measurements; interestingly, the obtained Faraday rotation angles are in the range of those expected in ITER plasmas.

17.
Rev Sci Instrum ; 79(10): 10F125, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044609

ABSTRACT

Two modular arrays of Langmuir probes designed to handle a heat flux of up to 25 MW/m(2) for 10 s exposures have been installed in the lower divertor target plates of the DIII-D tokamak. The 20 pyrolytic graphite probe tips have more than three times higher thermal conductivity and 16 times larger mass than the original DIII-D isotropic graphite probes. The probe tips have a fixed 12.5 degree surface angle to distribute the heat flux more uniformly than the previous 6 mm diameter domed collectors and a symmetric "rooftop" design to allow operation with reversed toroidal magnetic field. A large spring-loaded contact area improves heat conduction from each probe tip through a ceramic insulator into a cooled graphite divertor floor tile. The probe tips, brazed to molybdenum foil to ensure good electrical contact, are mounted in a ceramic tray for electrical isolation and reliable cable connections. The new probes are located 1.5 cm radially apart in a staggered arrangement near the entrance to the lower divertor pumping baffle and are linearly spaced 3 cm apart on the shelf above the in-vessel cryopump. Typical target plate profiles of J(sat), T(e), and V(f) with 4 mm spatial resolution are shown.

18.
Rev Sci Instrum ; 79(10): 10F303, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044616

ABSTRACT

Dust production and accumulation present potential safety and operational issues for the ITER. Dust diagnostics can be divided into two groups: diagnostics of dust on surfaces and diagnostics of dust in plasma. Diagnostics from both groups are employed in contemporary tokamaks; new diagnostics suitable for ITER are also being developed and tested. Dust accumulation in ITER is likely to occur in hidden areas, e.g., between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In the DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers, visible imaging, and spectroscopy. Laser scattering is able to resolve particles between 0.16 and 1.6 microm in diameter; using these data the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in two-dimension with a single camera or three-dimension using multiple cameras, but determination of particle size is challenging. In order to calibrate diagnostics and benchmark dust dynamics modeling, precharacterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase in carbon line (CI, CII, C(2) dimer) and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.

19.
Phys Rev Lett ; 97(13): 135001, 2006 Sep 29.
Article in English | MEDLINE | ID: mdl-17026039

ABSTRACT

The spatial structure of toroidal Alfvén eigenmodes and reversed shear Alfvén eigenmodes in DIII-D is obtained from electron-cyclotron-emission measurements. Peak measured temperature perturbations are of similar magnitude for both toroidal Alfvén eigenmodes and reversed shear Alfvén eigenmodes and found to be deltaT(e)/T(e) approximately equal to 0.5%. Simultaneous measurements of density fluctuations using beam-emission spectroscopy indicate deltan(e)/n(e) approximately equal to 0.25%. Predictions of the measured temperature and density perturbation profiles as well as deltaT(e)/deltan(e) from the ideal magnetohydrodynamic code NOVA are in close agreement with experiment.

SELECTION OF CITATIONS
SEARCH DETAIL