Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Nat Commun ; 15(1): 2975, 2024 Apr 06.
Article in English | MEDLINE | ID: mdl-38582938

ABSTRACT

Indirect Drive Inertial Confinement Fusion Experiments on the National Ignition Facility (NIF) have achieved a burning plasma state with neutron yields exceeding 170 kJ, roughly 3 times the prior record and a necessary stage for igniting plasmas. The results are achieved despite multiple sources of degradations that lead to high variability in performance. Results shown here, for the first time, include an empirical correction factor for mode-2 asymmetry in the burning plasma regime in addition to previously determined corrections for radiative mix and mode-1. Analysis shows that including these three corrections alone accounts for the measured fusion performance variability in the two highest performing experimental campaigns on the NIF to within error. Here we quantify the performance sensitivity to mode-2 symmetry in the burning plasma regime and apply the results, in the form of an empirical correction to a 1D performance model. Furthermore, we find the sensitivity to mode-2 determined through a series of integrated 2D radiation hydrodynamic simulations to be consistent with the experimentally determined sensitivity only when including alpha-heating.

3.
Nature ; 601(7894): 542-548, 2022 01.
Article in English | MEDLINE | ID: mdl-35082418

ABSTRACT

Obtaining a burning plasma is a critical step towards self-sustaining fusion energy1. A burning plasma is one in which the fusion reactions themselves are the primary source of heating in the plasma, which is necessary to sustain and propagate the burn, enabling high energy gain. After decades of fusion research, here we achieve a burning-plasma state in the laboratory. These experiments were conducted at the US National Ignition Facility, a laser facility delivering up to 1.9 megajoules of energy in pulses with peak powers up to 500 terawatts. We use the lasers to generate X-rays in a radiation cavity to indirectly drive a fuel-containing capsule via the X-ray ablation pressure, which results in the implosion process compressing and heating the fuel via mechanical work. The burning-plasma state was created using a strategy to increase the spatial scale of the capsule2,3 through two different implosion concepts4-7. These experiments show fusion self-heating in excess of the mechanical work injected into the implosions, satisfying several burning-plasma metrics3,8. Additionally, we describe a subset of experiments that appear to have crossed the static self-heating boundary, where fusion heating surpasses the energy losses from radiation and conduction. These results provide an opportunity to study α-particle-dominated plasmas and burning-plasma physics in the laboratory.

4.
Phys Rev E ; 94(2-1): 021202, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27627237

ABSTRACT

An accurate understanding of burn dynamics in implosions of cryogenically layered deuterium (D) and tritium (T) filled capsules, obtained partly through precision diagnosis of these experiments, is essential for assessing the impediments to achieving ignition at the National Ignition Facility. We present measurements of neutrons from such implosions. The apparent ion temperatures T_{ion} are inferred from the variance of the primary neutron spectrum. Consistently higher DT than DD T_{ion} are observed and the difference is seen to increase with increasing apparent DT T_{ion}. The line-of-sight rms variations of both DD and DT T_{ion} are small, ∼150eV, indicating an isotropic source. The DD neutron yields are consistently high relative to the DT neutron yields given the observed T_{ion}. Spatial and temporal variations of the DT temperature and density, DD-DT differential attenuation in the surrounding DT fuel, and fluid motion variations contribute to a DT T_{ion} greater than the DD T_{ion}, but are in a one-dimensional model insufficient to explain the data. We hypothesize that in a three-dimensional interpretation, these effects combined could explain the results.

5.
Phys Rev Lett ; 115(10): 105001, 2015 Sep 04.
Article in English | MEDLINE | ID: mdl-26382681

ABSTRACT

Hydrodynamic instabilities can cause capsule defects and other perturbations to grow and degrade implosion performance in ignition experiments at the National Ignition Facility (NIF). Here, we show the first experimental demonstration that a strong unsupported first shock in indirect drive implosions at the NIF reduces ablation front instability growth leading to a 3 to 10 times higher yield with fuel ρR>1 g/cm(2). This work shows the importance of ablation front instability growth during the National Ignition Campaign and may provide a path to improved performance at the high compression necessary for ignition.

6.
Rev Sci Instrum ; 83(10): 10D308, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126835

ABSTRACT

DT neutron yield (Y(n)), ion temperature (T(i)), and down-scatter ratio (dsr) determined from measured neutron spectra are essential metrics for diagnosing the performance of inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF). A suite of neutron-time-of-flight (nTOF) spectrometers and a magnetic recoil spectrometer (MRS) have been implemented in different locations around the NIF target chamber, providing good implosion coverage and the complementarity required for reliable measurements of Y(n), T(i), and dsr. From the measured dsr value, an areal density (ρR) is determined through the relationship ρR(tot) (g∕cm(2)) = (20.4 ± 0.6) × dsr(10-12 MeV). The proportionality constant is determined considering implosion geometry, neutron attenuation, and energy range used for the dsr measurement. To ensure high accuracy in the measurements, a series of commissioning experiments using exploding pushers have been used for in situ calibration of the as-built spectrometers, which are now performing to the required accuracy. Recent data obtained with the MRS and nTOFs indicate that the implosion performance of cryogenically layered DT implosions, characterized by the experimental ignition threshold factor (ITFx), which is a function of dsr (or fuel ρR) and Y(n), has improved almost two orders of magnitude since the first shot in September, 2010.

7.
Rev Sci Instrum ; 83(10): 10D312, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126839

ABSTRACT

The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator∕photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y(n)) measurements from below 10(9) (DD) to nearly 10(15) (DT). The detectors initially demonstrated detector-to-detector Y(n) precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of ± 10% and precision of ± 1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y(n) measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

8.
Rev Sci Instrum ; 83(10): 10E119, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126941

ABSTRACT

The south pole bang-time diagnostic views National Ignition Facility (NIF) implosions through the lower Hohlraum laser entrance hole to measure the time of peak x-ray emission (peak compression) in indirect-drive implosions. Five chemical-vapor-deposition diamond photoconductive detectors with different filtrations and sensitivities record the time-varying x rays emitted by the target. Wavelength selecting highly oriented pyrolytic graphite crystal mirror monochromators increase the x-ray signal-to-background ratio by filtering for 11-keV emission. Diagnostic timing and the in situ temporal instrument response function are determined from laser impulse shots on the NIF. After signal deconvolution and background removal, the bang time is determined to 45-ps accuracy. The x-ray "yield" (mJ∕sr∕keV at 11 keV) is determined from the time integral of the corrected peak signal.

9.
Phys Rev Lett ; 106(8): 085004, 2011 Feb 25.
Article in English | MEDLINE | ID: mdl-21405580

ABSTRACT

We demonstrate the hohlraum radiation temperature and symmetry required for ignition-scale inertial confinement fusion capsule implosions. Cryogenic gas-filled hohlraums with 2.2 mm-diameter capsules are heated with unprecedented laser energies of 1.2 MJ delivered by 192 ultraviolet laser beams on the National Ignition Facility. Laser backscatter measurements show that these hohlraums absorb 87% to 91% of the incident laser power resulting in peak radiation temperatures of T(RAD)=300 eV and a symmetric implosion to a 100 µm diameter hot core.

10.
J Environ Sci Health B ; 23(5): 513-24, 1988 Oct.
Article in English | MEDLINE | ID: mdl-3209817

ABSTRACT

Investigations have shown that the physical state of the DNA strongly influences the pattern of methylation observed when DNA or a substance containing DNA is treated with the fumigant methyl bromide. 1-Methyl-adenine and 7-methylguanine were identified, after hydrolysis, as the major methylated bases of DNA which had been treated in the solid state. 3-Methylcytosine, 3-methyladenine and 7-methyladenine were found as minor products. The overall methylation pattern was similar to that observed earlier for DNA of maize and wheat which had been fumigated. In contrast, when buffer solutions of DNA were treated with methyl bromide, the N-7 position of guanine was the major site and the N-3 position of adenine was the second most important site of methylation. This result corresponds to that previously observed in similar studies with buffer solutions of DNA and other methylating agents.


Subject(s)
DNA/metabolism , Hydrocarbons, Brominated/toxicity , Animals , Cattle , Chromatography, High Pressure Liquid , Hydrolysis , Methylation , Scintillation Counting , Triticum/analysis , Zea mays/analysis
11.
Chemotherapy ; 31(1): 29-33, 1985.
Article in English | MEDLINE | ID: mdl-3971777

ABSTRACT

We report a case of osteomyelitis due to a strain of Bacteroides uniformis highly resistant to clindamycin. The patient failed to respond to intravenous clindamycin therapy and eventually required amputation. This is the first documented occurrence of high-level clindamycin resistance in a clinical isolate of B. uniformis.


Subject(s)
Bacteroides Infections/drug therapy , Clindamycin/therapeutic use , Osteomyelitis/drug therapy , Amputation, Surgical , Drug Resistance, Microbial , Humans , Male , Middle Aged , Osteomyelitis/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...