1.
Radiat Prot Dosimetry ; 178(1): 95-100, 2018 Jan 01.
Article in English | MEDLINE | ID: mdl-28595335

ABSTRACT

Interventional radiology procedures have always been of particular concern because of the potential high dose to the workers. Special attention has recently been given to the lens dose: in 2011 the ICRP issued the recommendation 'Statement on Tissue Reactions' where a new limit of 20 mSv in a year, averaged over defined periods of 5 years, is given. Due to the impossibility of measuring the dose directly on the eye, there is not still a general consensus on a standardized methodology to assess the lens dose, which should be at the same time reliable, robust and simple to implement in practice. The procedure described here aims to assess the lens dose using the Hp(0.07) equivalent dose measured with a dosimeter worn at chest level above the lead apron, through a correlation with the total KAP per procedure and considering the type of the protection tools used during each procedure: glasses (with lateral shields), ceiling screen, both or neither of them and the frequency of their use.


Subject(s)
Lens, Crystalline/radiation effects , Occupational Exposure/analysis , Radiation Exposure/analysis , Radiography, Interventional , Eye Protective Devices , Humans , Occupational Exposure/prevention & control , Protective Clothing , Radiation Exposure/prevention & control
2.
Radiat Prot Dosimetry ; 168(3): 358-64, 2016 Mar.
Article in English | MEDLINE | ID: mdl-25987585

ABSTRACT

The purpose of this work is to give a contribution to the construction of a comprehensive knowledge of the exposure levels to gradient magnetic fields (GMF) in terms of the weighed peak (WP), especially for 3 Tesla scanners for which there are still few works available in the literature. A new generation probe for the measurement of electromagnetic fields in the range of 1 Hz-400 kHz was used to assess the occupational exposure levels to the GMF for 1.5 and 3.0 Tesla MRI body scanners, using the method of the WP according to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) approach. The probe was placed at a height of 1.1 m, close to the MRI scanners, where operators could stay during some medical procedures with particular issues. The measurements were performed for a set of typical acquisition sequences for body (liver) and head exams. The measured values of WP were in compliance with ICNIRP 2010 reference levels for occupational exposures.


Subject(s)
Magnetic Fields , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Occupational Exposure/analysis , Phantoms, Imaging , Radiation Monitoring/instrumentation , Whole Body Imaging/methods , Humans , Radiation Monitoring/methods
3.
Radiat Prot Dosimetry ; 154(4): 459-64, 2013 May.
Article in English | MEDLINE | ID: mdl-23060430

ABSTRACT

The purpose of this study was to investigate radiation doses in cerebral perfusion computed tomography (CT) examination. As a part of routine patient monitoring, data were collected on patients in terms of the skin dose and CT dose index (CTDIvol) and dose-length product (DLP) values. For the estimation of the dose to the lens a phantom study was performed. Dose values for skin and lens were below the threshold for deterministic effects. The results were also compared with already published data. For better comparison, the effective dose was also estimated. The values collected on patients were in the ranges 230-680 mGy for CTDI and 2120-2740 mGy cm for DLP, while the skin dose and estimated effective dose were 340-800 mGy and 4.9-6.3 mSv, respectively. These values measured in the phantom study were similar, while the doses estimated to the lens were 53 and 51 mGy for the right and left lens, respectively.


Subject(s)
Cerebrovascular Disorders/diagnostic imaging , Lens, Crystalline/radiation effects , Phantoms, Imaging , Skin/radiation effects , Tomography, X-Ray Computed , Humans , Radiation Dosage
4.
Radiat Prot Dosimetry ; 129(1-3): 288-90, 2008.
Article in English | MEDLINE | ID: mdl-18440959

ABSTRACT

The purpose of optimising the acquisition parameters in positron emission tomography is to improve the quality of the diagnostic images. Optimisation can be done by maximising the noise equivalent count rate (NECR) that in turn depends on the coincidence rate. For each bed position the scanner records coincidences and singles rates. For each patient, the true, random and scattered coincidences as functions of the single count rate(s) are determined by fitting the NEMA (National Electrical Manufacturers Association) 70 cm phantom count rate curves to measured clinical points. This enables analytical calculation of the personalised PNECR [pseudo NECR(s)] curve, linked to the NECR curve. For central bed positions, missing activity of approximately 70% is estimated to get maximum PNECR (PNECR(max)), but the improvement in terms of signal-toz-noise ratio would be approximately 15%. The correlation between patient weight and PNECR(max) is also estimated to determine the optimal scan duration of a single bed position as a function of patient weight at the same PNEC. Normalising the counts at PNECR(max) for the 70 kg patient, the bed duration for a 90 kg patient should be 230 s, which is approximately 30% longer. Although the analysis indicates that the fast scanner electronics allow using higher administered activities, this would involve poor improvement in terms of NECR. Instead, attending to higher bed duration for heavier patients may be more useful.


Subject(s)
Lutetium , Positron-Emission Tomography/instrumentation , Positron-Emission Tomography/methods , Radiopharmaceuticals , Silicates , Whole-Body Counting/methods , Body Weight , Humans , Image Interpretation, Computer-Assisted , Phantoms, Imaging
5.
Radiat Prot Dosimetry ; 129(1-3): 231-6, 2008.
Article in English | MEDLINE | ID: mdl-18283065

ABSTRACT

The performance of two digital mammography systems, Agfa CR75 and CRMM3 computed radiography (CR) and IMS Giotto MD direct digital radiography (DR), was assessed by applying a method recommended in the European protocol for quality control in mammography screening. The contrast-to-noise ratio (CNR) and mean glandular dose (MGD) values were measured and contrast detail (CD) analysis was performed. The CNRs for system CR were 21.9, 12.9, 9.5, 8.8, 7.4, 5.5 and 4.4 for 2, 3, 4, 4.5, 5, 6 and 7-cm polymenthylmethacrylate (PMMA) thickness, respectively. The respective CNRs for system DR were 10.4, 8.8, 6.3, 7.3, 7.2, 6.4 and 6.54. For the same phantom thickness sequence, the MGDs were 0.7, 1.1, 1.3, 1.6, 1.9, 2.5 and 3.4 mGy for system CR, whereas they were 0.7, 1.2, 1.1, 1.3, 1.8, 3.5 and 3.9 mGy for system DR. The CNR and MGD results satisfactorily correlate with CD analysis results. The MGD values compare well with the values recommended in the European protocol. Despite being simple, CNR and MGD can provide an effective system for performance assessment and constancy checks for related optimisations.


Subject(s)
Breast/radiation effects , Diagnostic Imaging/methods , Mammography/instrumentation , Mammography/methods , Radiographic Image Enhancement/methods , Breast/anatomy & histology , Contrast Media , Europe , Female , Humans , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed