Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 14(2)2024 Jan 14.
Article in English | MEDLINE | ID: mdl-38248058

ABSTRACT

Fluoroscopy has always been the cornerstone imaging method of interventional cardiology procedures. However, radiation exposure is linked to an increased risk of malignancies and multiorgan diseases. The medical team is even more exposed to X-rays, and a higher incidence of malignancies was reported in this professional group. In the last years, X-ray exposure has increased rapidly, involving, above all, the medical team and young patients and forcing alternative fluoroless imaging methods. In cardiac electrophysiology (EP) and pacing, the advent of 3D electroanatomic mapping systems with dedicated catheters has allowed real-time, high-density reconstruction of both heart anatomy and electrical activity, significantly reducing the use of fluoroscopy. In addition, the diffusion of intracardiac echocardiography has provided high anatomical resolution of moving cardiac structures, providing intraprocedural guidance for more complex catheter ablation procedures. These methods have largely demonstrated safety and effectiveness, allowing for a dramatic reduction in X-ray delivery in most arrhythmias' ablations. However, some technical concerns, as well as higher costs, currently do not allow their spread out in EP labs and limit their use to only procedures that are considered highly complex and time-consuming and in young patients. In this review, we aim to update the current employment of fluoroless imaging in different EP procedures, focusing on its strengths and weaknesses.

2.
Life (Basel) ; 13(8)2023 Jul 28.
Article in English | MEDLINE | ID: mdl-37629509

ABSTRACT

The difference between subcutaneous implantable cardioverter defibrillators (S-ICDs) and transvenous ICDs (TV-ICDs) concerns a whole extra thoracic implantation, including a defibrillator coil and pulse generator, without endovascular components. The improved safety profile has allowed the S-ICD to be rapidly taken up, especially among younger patients. Reports of its role in different cardiac diseases at high risk of SCD such as hypertrophic and arrhythmic cardiomyopathies, as well as channelopathies, is increasing. S-ICDs show comparable efficacy, reliability, and safety outcomes compared to TV-ICD. However, some technical issues (i.e., the inability to perform anti-bradycardia pacing) strongly limit the employment of S-ICDs. Therefore, it still remains only an alternative to the traditional ICD thus far. This review aims to provide a contemporary overview of the role of S-ICDs compared to TV-ICDs in clinical practice, including technical aspects regarding device manufacture and implantation techniques. Newer outlooks and future perspectives of S-ICDs are also brought up to date.

3.
Front Cardiovasc Med ; 10: 1151167, 2023.
Article in English | MEDLINE | ID: mdl-37304964

ABSTRACT

Introduction: Remote monitoring (RM) technologies have the potential to improve patient care by increasing compliance, providing early indications of heart failure (HF), and potentially allowing for therapy optimization to prevent HF admissions. The aim of this retrospective study was to assess the clinical and economic consequences of RM vs. standard monitoring (SM) through in-office cardiology visits, in patients carrying a cardiac implantable electronic device (CIED). Methods: Clinical and resource consumption data were extracted from the Electrophysiology Registry of the Trento Cardiology Unit, which has been systemically collecting patient information from January 2011 to February 2022. From a clinical standpoint, survival analysis was conducted, and incidence of cardiovascular (CV) related hospitalizations was measured. From an economic standpoint, direct costs of RM and SM were collected to compare the cost per treated patient over a 2-year time horizon. Propensity score matching (PSM) was used to reduce the effect of confounding biases and the unbalance of patient characteristics at baseline. Results: In the enrollment period, N = 402 CIED patients met the inclusion criteria and were included in the analysis (N = 189 patients followed through SM; N = 213 patients followed through RM). After PSM, comparison was limited to N = 191 patients in each arm. After 2-years follow-up since CIED implantation, mortality rate for any cause was 1.6% in the RM group and 19.9% in the SM group (log-rank test, p < 0.0001). Also, a lower proportion of patients in the RM group (25.1%) were hospitalized for CV-related reasons, compared to the SM group (51.3%; p < 0.0001, two-sample test for proportions). Overall, the implementation of the RM program in the Trento territory was cost-saving in both payer and hospital perspectives. The investment required to fund RM (a fee for service in the payer perspective, and staffing costs for hospitals), was more than offset by the lower rate of hospitalizations for CV-related disease. RM adoption generated savings of -€4,771 and -€6,752 per patient in 2 years, in the payer and hospital perspective, respectively. Conclusion: RM of patients carrying CIED improves short-term (2-years) morbidity and mortality risks, compared to SM and reduces direct management costs for both hospitals and healthcare services.

4.
Expert Rev Med Devices ; 20(6): 493-503, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37128658

ABSTRACT

Atrial fibrillation is the most common arrythmia and it is linked to an increased risk of stroke. Even if anticoagulation therapy reduces the rate of stroke the benefits of this therapy have to be balanced with the increased risk of hemorrhagic event. Left atrial appendage closure is a valid alternative to long-term anticoagulation in patients with atrial fibrillation and high hemorrhagic risk. Actually new devices with different features have been tested and introduced progressively in the clinical practice. Improvements in preprocedural imaging evaluation and the learning curve of the operators led to percutaneous left atrial appendage closure a safe and effective procedure. A good knowledge of different devices and the technique of implant is necessary for optimization percutaneous left atrial appendage closure and the reduction of complications during the acute phase and follow up.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Anticoagulants/therapeutic use , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Treatment Outcome , Stroke/prevention & control , Stroke/complications , Hemorrhage/chemically induced , Hemorrhage/complications , Cardiac Catheterization
5.
Medicina (Kaunas) ; 59(2)2023 Feb 19.
Article in English | MEDLINE | ID: mdl-36837606

ABSTRACT

Electrical storm is a medical emergency characterized by ventricular arrythmia recurrence that can lead to hemodynamic instability. The incidence of this clinical condition is rising, mainly in implantable cardioverter defibrillator patients, and its prognosis is often poor. Early acknowledgment, management and treatment have a key role in reducing mortality in the acute phase and improving the quality of life of these patients. In an emergency setting, several measures can be employed. Anti-arrhythmic drugs, based on the underlying disease, are often the first step to control the arrhythmic burden; besides that, new therapeutic strategies have been developed with high efficacy, such as deep sedation, early catheter ablation, neuraxial modulation and mechanical hemodynamic support. The aim of this review is to provide practical indications for the management of electrical storm in acute settings.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Humans , Quality of Life , Arrhythmias, Cardiac , Anti-Arrhythmia Agents/therapeutic use , Prognosis
SELECTION OF CITATIONS
SEARCH DETAIL
...