Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Publication year range
1.
Curr Pharm Des ; 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38874045

ABSTRACT

BACKGROUND: Cannabidiol (CBD) is the principal non-hallucinogenic compound of Cannabis plants with high clinical interest because CBD has been described as having anti-inflammatory, analgesic and anticonvulsant properties. CBD is considered a multitarget compound as it can interact with a wide range of targets, explaining their multiplicity of effects. Some clinical studies have indicated certain side effects of CBD, including somnolence, anemia and diarrhea, while the elevation of transaminases is considered as an exclusion criterion from the trial. Since the red blood cells (RBCs) are a source of transaminase, we assayed in vitro effect on RBCs stability. METHODS: We performed in vitro experiments with RBCs obtained from human peripheral blood with normal hematological parameters exposed to CBD in the range of therapeutic uses. We evaluated RBCs morphological changes, membrane fragility and hemoglobin release as a reflection of hemolysis. RESULTS: CBD induced an increase in the hemoglobin release (3.27 µg/106 RBC), without altered RBC osmotic fragility. When RBCs suspensions were incubated with CBD the initial number of elements (RBCs + vesicles) was increased up to 65% after 20 min and returned to basal level after 40 min of incubation. In the first 20 min, the accounts of elements were enriched in the smaller vesicles that disappeared after the remaining 20 minutes. CONCLUSION: These results suggest that CBD affects the indemnity of erythrocytes in vitro, inducing the formation of hemolytic vesicles that can provide the basis for the development of anemia, transaminase elevation and underlying tissular iron overload in patients chronically treated with CBD.

2.
Pharmaceuticals (Basel) ; 16(10)2023 Oct 21.
Article in English | MEDLINE | ID: mdl-37895972

ABSTRACT

The extracellular purinergic agonist uridine diphosphate glucose (UDP-G) activates chemotaxis of human neutrophils (PMN) and the recruitment of PMN at the lung level, via P2Y14 purinergic receptor signaling. This effect is similar to the activation of PMN with N-formyl-methionyl-leucyl-phenylalanine (fMLP), a mechanism that also triggers the production of superoxide anion and hydrogen peroxide via the NADPH oxidase system. However, the effects of UDP-G on this system have not been studied. Defects in the intracellular phagocyte respiratory burst (RB) cause recurrent infections, immunodeficiency, and chronic and severe diseases in affected patients, often with sepsis and hypoxia. The extracellular activation of PMN by UDP-G could affect the RB and oxidative stress (OS) in situations of inflammation, infection and/or sepsis. The association of PMNs activation by UDP-G with OS and RB was studied. OS was evaluated by measuring spontaneous chemiluminescence (CL) of PMNs with a scintillation photon counter, and RB by measuring oxygen consumption with an oxygen Clark electrode at 37 °C, in non-stimulated cells and after activation (15 min) with lipopolysaccharides (LPS, 2 µg/mL), phorbol myristate acetate (PMA, 20 ng/mL), or UDP-G (100 µM). The stimulation index (SI) was calculated in order to establish the activation effect of the three agonists. After stimulation with LPS or PMA, the activated PMNs (0.1 × 106 cells/mL) showed an increase in CL (35%, p < 0.05 and 56%, p < 0.01, SI of 1.56 and 2.20, respectively). Contrariwise, the stimulation with UDP-G led to a decreased CL in a dose-dependent manner (60%, 25 µM, p < 0.05; 90%, 50-150 µM, p < 0.001). Nonetheless, despite the lack of oxidative damage, UDP-G triggered RB (SI 1.8) in a dose-dependent manner (38-50%, 100-200 µM, p < 0.0001). UDP-G is able to trigger NADPH oxidase activation in PMNs. Therefore, the prevention of OS and oxidative damage observed upon PMN stimulation with UDP-G indicates an antioxidant property of this molecule which is likely due to the activation of antioxidant defenses. Altogether, LPS and UDP-G have a synergistic effect, suggesting a key role in infection and/or sepsis.

3.
Acta bioquím. clín. latinoam ; 49(4): 399-407, dic. 2015. graf, tab
Article in Spanish | LILACS | ID: biblio-837579

ABSTRACT

El primer paso para obtener seguridad en los resultados emitidos por el laboratorio clínico es confirmar que los procedimientos de medida utilizados tienen un desempeño analítico aceptable. Para conseguirlo se verificó el contador hematológico Beckman Coulter LH 750 de acuerdo con las especificaciones del fabricante y con los requisitos de calidad de este laboratorio. Los parámetros de desempeño evaluados, tanto en modo manual como automático, fueron: porcentaje de arrastre, según protocolo CLSI H26-A2, precisión en condiciones de repetibilidad, precisión en condiciones de precisión intermedia y veracidad, según protocolo CLSI EP15-A2 utilizando controles BIO-RAD, intervalo de medición, según protocolo CLSI EP6-A, límite de cuantificación, según protocolo CLSI EP17-A2 e intervalos de referencia, según protocolo CLSI EP28-A3C. Los datos se analizaron mediante LinChecker y GraphPad 5. En los ensayos realizados se cumplió con las especificaciones estipuladas por el fabricante, como así también con el requisito de calidad de este laboratorio que es variabilidad biológica mínima. También se verificaron los intervalos de referencia para individuos adultos. De esta manera, se logró realizar la verificación del contador hematológico, evidenciando que los parámetros analíticos evaluados tienen un desempeño aceptable.


The first step for safety in the results issued by the clinical laboratory is to confirm that all analytical measurement procedures have shown an acceptable analytical performance. A quality performance evaluation of automated hematology analyzer Beckman Coulter LH 750 was performed according to the quality requirements of our laboratory and manufacturer's specifications. The performance parameters evaluated by both manual and automatic mode were: carryover according to CLSI H26-A2 protocol; repeatability, intermediate precision and trueness according to CLSI EP15-A2 protocol and using BIO-RAD controls; linearity according to CLSI EP6-A protocol; quantification limits according to CLSI EP17-A2 protocol; and reference intervals according to CLSI EP28-A3C protocol. Data were analyzed using LinChecker and GraphPad5 programs. The tests performed complied with the requirements stipulated by the manufacturer and the quality requirements of our laboratory like minimal biological variability. Reference intervals for adult individuals were also checked. Consequently, performance evaluation of the automated hematology analyzer showed that the assessed laboratory parameters have acceptable performance.


O primeiro passo para obter segurança nos resultados emitidos pelo laboratório clínico é confirmar que os processos de medição utilizados tenham um desempenho analítico aceitável. Para obtê-los foi verificado o analisador hematológico Beckman Coulter LH 750 de acordo com as especificações do fabricante e os requisitos de qualidade deste laboratório. Os parâmetros de desempenho avaliados, tanto em modo manual quanto automático, foram: percentual de arrastamento, de acordo com o protocolo CLSI H26-A2, em condições de repetitibidade, precisão em condições de precisão intermediária e veracidade, conforme o protocolo CLSI EP15-A2 usando controles Bio-Rad, intervalo de medição segundo o protocolo CLSI EP6-A, limite de quantificação, de acordo com CLSI EP- 17-A2 e intervalos de referência, de acordo com o protocolo CLSI EP28-A3C. Os dados foram analisados através de LinChecker e GraphPad 5. Nos ensaios realizados foram obsevadas as especificações estabelecidas pelo fabricante, bem como a exigência de qualidade deste laboratório que é variabilidade biológica mínima. Os intervalos de referência para indivíduos adultos também foram verificados. Desta forma, foi possível realizar a verificação do analisador hematológico, que demonstra que os parâmetros analíticos avaliados têm um desempenho aceitável.


Subject(s)
Hematologic Tests , Reference Standards , Guidelines as Topic , Reference Values , Checklist , Evaluation Study
4.
Blood Res ; 50(3): 154-9, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26457282

ABSTRACT

BACKGROUND: Tyrosine kinase inhibitors (TKIs) are the recommended treatment for patients with chronic myeloid leukemia (CML). The MDR1/ABCB1 gene plays a role in resistance to a wide spectrum of drugs, including TKIs. However, the association of MDR1/ABCB1 gene polymorphisms (SNPs) such as C1236T, G2677T/A, and C3435T with the clinical therapeutic evolution of CML has been poorly studied. We investigated these gene polymorphisms in CML-patients treated with imatinib, nilotinib and/or dasatinib. METHODS: ABCB1-SNPs were studied in 22 CML-patients in the chronic phase (CP) and 2 CML-patients in blast crisis (BC), all of whom were treated with TKIs, and compared with 25 healthy controls using nested-PCR and sequencing techniques. RESULTS: Seventeen different haplotypes were identified: 7 only in controls, 6 only in CML-patients, and the remaining 4 in both groups. The distribution ratios of homozygous TT-variants present on each exon between controls and CML-patients were 2.9 for exon 12, and 0.32 for the other 2 exons. Heterozygous T-variants were observed in all controls (100%) and 75% of CML-patients. Wt-haplotype (CC-GG-CC) was observed in 6 CML-patients (25%). In this wt-group, two were treated with nilotinib and reached a major molecular response. The remaining 4 cases had either a minimal or null molecular response, or developed bone marrow aplasia. CONCLUSION: Our results suggest that SNPs of the MDR1/ABCB1 gene could help to characterize the prognosis and the clinical-therapeutic evolution of CML-patients treated with TKIs. Wt-haplotype could be associated with a higher risk of developing CML, and a worse clinical-therapeutic evolution.

SELECTION OF CITATIONS
SEARCH DETAIL