Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 45-52, 2020 Jan.
Article in English, Spanish | MEDLINE | ID: mdl-32111365

ABSTRACT

This article provides an analysis of the results obtained in 2017 by the participants inscribed in the External Quality Control Programme of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), which includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology, and genotypic bacterial resistance. The results obtained in 2017 confirm the excellent skill and good technical standards found in previous editions. However, the programme again showed that erroneous results can be obtained in any laboratory and even in clinically relevant determinations. Once again, the results of this program highlight the need to implement both internal and external controls, as in the SEIMC programme.


Subject(s)
Infectious Disease Medicine/standards , Laboratories/standards , Microbiology/standards , Quality Control , Bacteriology , Humans , Mycology , Spain
2.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 53-60, 2020 Jan.
Article in English, Spanish | MEDLINE | ID: mdl-32111366

ABSTRACT

This article provides an analysis of the results obtained in 2018 by the participants inscribed in the External Quality Control Programme of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), which includes controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology, and genotypic bacterial resistance. The results obtained in 2018 confirm the excellent skill and good technical standards found in the vast majority of Spanish clinical microbiology laboratories, as shown in previous editions. However, the programme again shows that erroneous results can be obtained in any laboratory and even in clinically relevant determinations. Once again, the results of this programme highlight the need to implement both internal and external controls, as in the SEIMC programme.


Subject(s)
Infectious Disease Medicine/standards , Laboratories/standards , Microbiology/standards , Quality Control , Bacteriology , Humans , Mycology , Spain
3.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 61-66, 2020 Jan.
Article in English, Spanish | MEDLINE | ID: mdl-32111367

ABSTRACT

BACKGROUND: Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarised the results obtained from the 2017 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads and HCV genotyping. METHODS AND RESULTS: In the HIV-1 programme, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (35% on average) obtained values outside the accepted range (mean±0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was good, with up to 94% of laboratories reporting results within the limits (D<0.5 log10 copies/mL). The HBV and HCV programme consisted of two standards with different viral load contents. Most of the participants, 82% in the case of HCV and 87% in that of HBV, obtained all the results within the accepted range (mean±1.96 SD log10 UI/mL). CONCLUSIONS: Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory. Due to the marked interlaboratory variability observed, it is advisable to use the same method and laboratory for patient follow-up.


Subject(s)
HIV Infections , Hepatitis B , Hepatitis C , Quality Control , Viral Load , HIV Infections/diagnosis , HIV-1 , Hepacivirus , Hepatitis B/diagnosis , Hepatitis B virus , Hepatitis C/diagnosis , Humans , Infectious Disease Medicine/standards
4.
Enferm Infecc Microbiol Clin (Engl Ed) ; 38 Suppl 1: 67-72, 2020 Jan.
Article in English, Spanish | MEDLINE | ID: mdl-32111368

ABSTRACT

BACKGROUND: Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarised the results obtained from the 2018 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads and HCV genotyping. METHODS AND RESULTS: In the HIV-1 program, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (28% on average) obtained values outside the accepted range (mean±0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was good, with most laboratories reporting results within the limits (D<0.5 log10 copies/mL). The HBV and HCV programme consisted of two standards with different viral load contents. Most of the participants, 87% in the case of HCV and 88% in the HBV, obtained all the results within the accepted range (mean±1.96 SD log10 UI/mL). CONCLUSIONS: Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory. Due to the marked interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow-up.


Subject(s)
HIV Infections , Hepatitis B , Hepatitis C , Quality Control , Viral Load , HIV Infections/diagnosis , HIV-1 , Hepacivirus , Hepatitis B/diagnosis , Hepatitis B virus , Hepatitis C/diagnosis , Humans , Infectious Disease Medicine/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...