Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 70
Filter
1.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Article in English | LILACS, BBO - Dentistry | ID: biblio-1523860

ABSTRACT

Objective: The aim of this in vitro study w as t o analyze the influence of the titanium dioxide nanotubes i n a self-cure mode polymerization of a dual resin luting agent through push out bond strength and radiopacity tests. Material and Methods: After mixed with a commercial du al self-adhesive resin cement, three concentrations o f tit anium dioxide nanotubes (0.3, 0.6, and 0.9% by weight) we re analyzed in self-curing mode. T he bond strength to bovine root dentin and fi berglass posts was assessed with the push out bond str ength t est and was evaluated in three thirds (cervical, middle and apical) (n=10), followed by failure mode analysis (SEM), and the ISO standard 9917-2 was followed for radiopacity test (n=10). Data were statistically analyzed by one-way ANOVA test, followed by Tukey's test (α=0.05). Results: Reinforced self-adhesive resin cement with 0.6% titanium dioxide nanotubes showed significant difference compared to the control gr oup for push out test (p=0.00158). The modified groups did not s how significant difference among thirds (p=0.782). Radiopacity sh owed higher value for group w ith 0.9% titanium dioxide nanotubes in comparison w ith control group (p<0.001). Conclusion: The addition of titanium dioxide nanotubes to a self-adhesive resin cement increased the bond strength to dentin and radiopacity values in the self-cure polymerization mode (AU)


Objetivo: O objetivo deste estudo in vitro foi analisar a influência de nanotubos de dióxido de titânio na polimerização química de um agente cimentante resinoso dual através de testes de resistência à união e radiopacidade. Material e Métodos: Após misturado com um cimento resinoso auto-adesivo comercial, três concentrações de nanotubos de dióxido de titânio (0,3, 0,6 e 0,9% em peso) foram analisadas. A resistência da união para a dentina da raiz bovina e os pinos de fibra de vidro foi avaliada pelo teste de push-out e avaliada em três terços (cervical, médio e apical) (n = 10), seguido pelo análise de modo de falha (MEV) e a norma ISO 9917-2 foi seguido para teste de radiopacidade (n = 10). Os dados foram analisados estatisticamente pelo teste ANOVA um fator seguido do teste de Tukey (α = 0,05). Resultados: O cimento resinoso auto-adesivo reforçado com nanotubos de dióxido de titânio a 0,6% mostrou diferença significativa em comparação com o grupo controle para teste de push-out (p=0,00158). Os grupos modificados não mostraram diferença significativa entre os terços (p=0,782). A radiopacidade mostrou maior valor para o grupo com nanotubos de dióxido de titânio 0,9% em comparação com o grupo controle (p<0,001). Conclusão: A adição de nanotubos de dióxido de titânio a um cimento resinoso auto-adesivo aumentou a os valores de resistência de união à dentina e radiopacidade no modo de polimerização química do agente cimentante (AU)


Subject(s)
Titanium , Dental Cements , Dental Pins , Nanotubes
2.
Materials (Basel) ; 15(22)2022 Nov 09.
Article in English | MEDLINE | ID: mdl-36431390

ABSTRACT

Commercial Yttria-tetragonal zirconia polycrystalline (Y-TZP) was subjected to surface treatments, and the bond strength of dual resin cement to Y-TZP and failure modes were evaluated. Disks (12 mm × 2 mm), cylinders (7 mm × 3.3 mm), and bars (25 mm × 5 mm × 2 mm) were milled from Y-TZP CAD-CAM blocks, divided into seven groups, and subjected to different surface treatments; silicatization was used as control. On the basis of the literature, this study evaluated modifications with films containing SiO2 nanoparticles and silane; SiO2+ZrO2­SiO2 (50%) and ZrO2 (50%) nanoparticles, SiO2+ZrO2/Silane-SiO2 (50%) and ZrO2 (50%) nanoparticles, and silane. Specimens were analyzed by wettability (n = 3), surface free energy (n = 3), X-ray diffraction (n = 1), Fourier transform infrared spectroscopy (FTIR) (n = 1), roughness (n = 5), shear bond test (n = 10), and dynamic modulus (n = 3). Specimens treated with hydrofluoric acid­HF 40% presented significantly higher contact angle and lowest surface free energy (p < 0.05). The SiO2/Silane presented crystalline SiO2 on the surface. The surface roughness was significantly higher for groups treated with nanofilms (p < 0.05). Shear bond strength was significantly higher for silicatization, HF 40%/silicatization, SiO2/Silane, and SiO2+ZrO2/Silane groups. The proposed treatments with nanofilms had potentially good results without prejudice to the physicochemical characteristics of zirconia. Generally, groups that underwent silica surface deposition and silanization had better bond strength (p < 0.005).

3.
Dent Mater ; 38(11): e275-e283, 2022 11.
Article in English | MEDLINE | ID: mdl-36068105

ABSTRACT

OBJECTIVES: This study evaluated the effect of TiO2 nanoparticles + dense hydroxyapatite (HA) on human osteoblast cells (SAOS-2). METHODS: Particulate bovine HA powder with or without the addition of either 5 or 8 % TiO2 (HA, HA/TiO2Np5 % or HA/TiO2Np8 %) were pressed into disks (Ø = 12.5 mm; thickness = 1.3 mm) uniaxially (100 MPa) and isostatically (200 MPa/1 min) and sintered at 1300 °C. Y-TZP disks were used as control. The following tests were performed: Scanning Electron Microscopy and Dispersive Energy Spectroscopy (SEM/EDS), Atomic Force Microscopy (AFM), cell viability assay (Alamar Blue-AB) and mineralized matrix deposition (Alizarin Red-AR). AB and AR data were submitted to 2-way ANOVA/Tukey tests and ANOVA/Tukey tests, respectively. RESULTS: SEM revealed that the surface of HA/TiO2Np5% resembles DPBHA surface, but also contains smaller granules. HA/TiO2Np8% characteristics resembles HA/TiO2Np5% surface, but with irregular topography. Y-TZP showed a typical oxide ceramic surface pattern. EDS revealed Ca, O, and P in all samples. C, O, and Zr appeared in Y-TZP samples. AFM data corroborates SEM analysis. AB test revealed excellent cellular viability for HA/TiO2Np5% group. AR test showed that all groups containing TiO2np had more mineralized matrix deposition than all other groups, with statistically differences between HA/TiO2Np8% and HA cultivated in non-osteogenic medium. Culture in osteogenic medium exhibited much more mineralized matrix deposition by TiO2np groups. SIGNIFICANCE: In conclusion, the addition of TiO2np showed chemical, superficial, and biological changes in the reinforced materials. HA/TiO2Np5% showed the best results for cell viability and HA/TiO2Np8% for mineralized matrix deposition.


Subject(s)
Durapatite , Nanoparticles , Animals , Cattle , Durapatite/chemistry , Durapatite/pharmacology , Humans , Microscopy, Electron, Scanning , Osteoblasts , Oxides/pharmacology , Powders , Surface Properties , Titanium/chemistry , Titanium/pharmacology
4.
Dent Mater ; 38(10): 1669-1678, 2022 10.
Article in English | MEDLINE | ID: mdl-36089408

ABSTRACT

OBJECTIVES: To characterize the behavior of three different polymeric agents before and after an erosive challenge on dentin permeability, to analyze their degradation in both conditions, and to analyze their degree of conversion (DC). METHODS: The permeability of human dentin disks (1.0 ± 0.2 mm) was measured with smear layer, after its removal, after treatment (LpTreat) with Gluma Desensitizer, PRG Barrier Coat (PBC) or Icon infiltrant (n = 11/group) and after exposure to citric acid (LpEro) (6%, pH 2.1, 1 min). The specimens were analyzed under a Laser Scanning Confocal Microscope (n = 2/group) and the products' DC were calculated. Data were subjected to 2-way repeated measures ANOVA and post-hoc Bonferroni (permeability analysis), to paired t-test (for specimens treated with Icon) and to t-test (DC analysis) (α < 0.05). RESULTS: Icon showed the lowest LpTreat and LpEro values, while PBC and Gluma did not differ from each other under these conditions. Icon and PBC showed LpEro similar to a dentin with smear layer. Under the Laser Scanning Confocal Microscope, more deposits were noticeable on dentin after treating with PBC. Gluma presented the deepest penetration in dentin. The DC of PBC was the highest. SIGNIFICANCE: Icon caused the highest reduction on permeability values, followed by PBC and Gluma. PBC generated more deposits covering dentin and seemed to be more efficient after an erosive challenge. The association of a polymeric resin with inorganic ion-releasing fillers seem to be a great strategy to manage dentin hypersensitivity under erosive conditions.


Subject(s)
Dentin Desensitizing Agents , Dentin Sensitivity , Smear Layer , Citric Acid/pharmacology , Dentin , Dentin Desensitizing Agents/chemistry , Dentin Permeability , Glutaral/pharmacology , Humans , Microscopy, Confocal , Microscopy, Electron, Scanning , Polymethacrylic Acids , Spectroscopy, Fourier Transform Infrared
5.
Dent Mater ; 38(8): e220-e230, 2022 08.
Article in English | MEDLINE | ID: mdl-35750506

ABSTRACT

OBJECTIVE: This study evaluated the microshear bond strength of a resin cement to Y-TZP after different methods of TiO2 nanotubes (nTiO2) incorporation on pre-sintered Y-TZP surfaces. METHODS: nTiO2 were synthesized and incorporated on Y-TZP slices as follows (n = 15): 1) nTiO2 mixed with isopropyl alcohol/manual application (MAl); 2) nTiO2 mixed with acetone/manual application (MAc); 3) nTiO2 mixed with isopropyl alcohol/high-pressure vacuum application (HPVAl); 4) nTiO2 mixed with acetone/high-pressure vacuum application (HPVAc). As controls, surfaces were sandblasted with Al2O3 (OX) or Rocatec silicatization (ROC). All ceramics were sintered after nTiO2 incorporation. Surface treatments of OX and ROC were made after sintering. Surfaces were characterized by confocal laser microscopy, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Resin composite cylinders (1.40 mm diameter and 1 mm height) were cemented with a resin cement, stored in water at 37 °C for 24 h and thermocycled for 10 000 cycles before microshear bond strength evaluation. Data were analyzed with one-way ANOVA and Games-Howell (α = 0.05), and fracture analysis was performed using a stereomicroscope. RESULTS: EDS confirmed the presence of TiO2 on treated Y-TZP. The confocal analysis showed higher roughness for HPVAc and OX. There were significant differences between surface treatments (p < 0.001). HPVAl (22.96 ± 10.3), OX (34.16 ± 7.9) and ROC (27.71 ± 9.4) showed higher microshear bond strengths and were statistically similar (p > 0.05). MAC showed intermediary values, and HPVAc and MAl presented decreased bond strength, with a high percentage of premature debonding. CONCLUSION: High-pressure vacuum application of nTiO2 mixed with isopropyl alcohol was able to produce bond strength values compared to conventional air abrasion and Rocatec silicatization. SIGNIFICANCE: The infiltration of TiO2 nanostructures on the pre-sintered Y-TZP is an interesting approach that can improve bond strength without the need of sandblasting methods.


Subject(s)
Dental Bonding , Nanotubes , 2-Propanol , Acetone , Air Abrasion, Dental , Dental Bonding/methods , Materials Testing , Microscopy, Electron, Scanning , Resin Cements/chemistry , Shear Strength , Surface Properties , Titanium , Yttrium/chemistry , Zirconium/chemistry
6.
J Dent ; 107: 103609, 2021 04.
Article in English | MEDLINE | ID: mdl-33610589

ABSTRACT

OBJECTIVE: The aim of this paper is to present the results of a consensus meeting on the threshold property requirements for the clinical use of conventional glass-ionomer cements (GICs) for restorative indications. METHODS: Twenty-one experts on GICs evaluated the results of tests on mechanical and optical properties of 18 different brands of restorative GICs: Bioglass R [B], Chemfil Rock [CR], Equia Forte [EF], Gold Label 2 [GL2], Gold Label 9 [GL9], Glass Ionomer Cement II [GI], Ionglass [IG], Ion Z [IZ], Ionomaster [IM], Ionofil Plus [IP], Ionostar Plus [IS], Ketac Molar Easymix [KM], Magic Glass [MG], Maxxion R [MA], Riva Self Cure [R], Vidrion R [V], Vitro Fil [VF] and Vitro Molar [VM]. All experiments were carried out by a team of researchers from Brazil and England following strict protocols, under the same laboratory conditions throughout, and maintaining data integrity. RESULTS: There was consensus on: determining as primary properties of the material: compressive strength, microhardness, acid erosion and fluoride release, and as secondary properties: contrast ratio and translucency parameter, in order to rank the materials. Seven brands were below the thresholds for restorative indications: IZ, IM, IG, MA, VF, B and MG. CONCLUSIONS: Based on the primary properties adopted as being essential for restorative indications, the conventional restorative GICs that met the thresholds and could be considered suitable as long-term restorative materials were: EF, GI, GL9, KM, IP, GL2, IS, CR, V, VM and R. A decision-making process to select the best GIC must also include results from clinical trials. CLINICAL SIGNIFICANCE: This study provides a ranking of GICs that could be considered suitable as long-term restorative materials based on their main properties.


Subject(s)
Glass Ionomer Cements , Brazil , Compressive Strength , Consensus , Materials Testing
7.
Clin Oral Investig ; 25(4): 2029-2036, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32783095

ABSTRACT

OBJECTIVES: To evaluate the marginal adaptation and internal space of crowns produced by 4 CAD/CAM systems using microcomputed tomography (µCT) and replica technique (RT). MATERIALS AND METHODS: Monolithic lithium disilicate crowns were milled (Ceramill, Cerec, EDG, and Zirkonzahn) (n = 10). The cement film obtained with low viscosity silicone was scanned by the µCT system and captured by a stereomicroscope, according to RT. Two-way ANOVA followed by Tukey's test were used for statistical analysis (α = 0.05). A uniformity index (UI) was idealized to describe the distribution of crowns' internal space and submitted to the Kruskal-Wallis and Tukey's test (α = 0.05). The correlation between µCT and RT was performed by Pearson's Correlation Coeficient (α = 0.05). RESULTS: Marginal adaptation and internal space were statistically significant different between the experimental groups for the µCT and RT (p < 0.05). The medians of the 4 systems tested were within clinically acceptable range and the mean (± SD) highest marginal discrepancy was recorded in the Ceramill group at 133.0 ± 71.5 µm (µCT) and 90.6 ± 38.5 µm (RT). For internal fit, the UI disclosed a better distribution of the internal space for the Zirkonzahn group (p < 0.001). There was a strong correlation between the methods (p = 0.01 and r = 0.69). CLINICAL RELEVANCE: Because of the variability of the CAD/CAM systems available, evaluating their accuracy is of clinical interest. The 4 systems are capable to produce restorations adaptated within clinically appropriate levels. The µCT and RT are efficient adaptation methodologies.


Subject(s)
Dental Marginal Adaptation , Dental Prosthesis Design , Ceramics , Computer-Aided Design , Crowns , Dental Porcelain , X-Ray Microtomography
8.
J Esthet Restor Dent ; 33(6): 935-942, 2021 09.
Article in English | MEDLINE | ID: mdl-33188585

ABSTRACT

OBJECTIVE: To evaluate the translucency parameter (TP) and contrast ratio (CR) of different conventional restorative glass-ionomer cements (GICs). MATERIALS AND METHODS: Eighteen brands of GICs were evaluated. Five disks of each material were made following ISO 9917-1. The luminous reflectance and Central Bureau of the International Commission on Illumination parameters of disks were evaluated using a colorimeter, against backings of white and black, to obtain the translucent parameter and contrast ratio of different brands of glass-ionomer cements. The correlation between translucency parameter and contrast ratio was assessed with the Pearson correlation test. The translucent and contrast ratio parameters values were submitted to the one-way ANOVA and Tukey test for multiple comparisons (p < 0.05). RESULTS: There was a strong inverse relationship between CR and TP (r2  = 0.94, p < 0.001). The contrast ratio decreased as translucency increased. There were significant differences in TP and CR among brands (p < 0.001). CONLUSIONS: GICs exhibit different translucency and contrast ratio behavior. Some brands of GICs presented very low TP and this condition would be unacceptable for areas with esthetic demands. In addition, TP and CR showed a strong linear relationship. CLINICAL SIGNIFICANCE: The results found in this study demonstrated that the knowledge of the translucency and CR of different conventional restorative GICs is important in order to guide clinicians in the selection of restorative GICs for anterior teeth.


Subject(s)
Glass Ionomer Cements , Materials Testing
9.
J Mech Behav Biomed Mater ; 115: 104287, 2021 03.
Article in English | MEDLINE | ID: mdl-33352427

ABSTRACT

This study evaluated the protective effect of TiF4 varnish, after pre-treatment with proantocyanidin or chlorhexidine, on the progression of erosive dentin loss (EDL), under the presence or absence of the demineralized organic matrix (DOM). Bovine root dentin samples were eroded for 30 min (0.1% citric acid, pH 2.5) and the loss was measured by profilometry. Half of them were subjected to the DOM removal using collagenase for 4 days, while the other half remained immersed in water. The removal of DOM was checked by profilometry. Samples were divided into 24 groups (n = 15) according to the factors: 1- With or without DOM; 2- Pre-treatment with 0.012% chlorhexidine gel, 10% proanthocyanidin gel or untreated for 1 min; 3-Final Treatment with TiF4 varnish, NaF varnish, placebo varnish or untreated for 6 h. The samples were submitted to a pH cycling for 5 days: 0.1% citric acid (4 × 90s/day) and artificial saliva between the challenges. The final profile was obtained for the calculation of EDL (µm, three-way ANOVA/Tukey test). When DOM was preserved, the EDL was lower compared to the condition without DOM (7.08 ± 4.03 µm and 9.80 ± 3.79 µm, p < 0.001, respectively), regardless of the treatments. The pre-treatment had no influence on the progression of EDL (p = 0.637), while the final treatment (TiF4 varnish only, 6.77 ± 4.08 µm) was effective in reducing the progression of EDL (NaF varnish: 9.52 ± 4.02 µm; Placebo varnish: 8.64 ± 4.06 µm and no treatment: 8.80 ± 3.95 µm). It can be concluded that DOM has important protective effect on the progression of EDL. TiF4 was the unique treatment capable of reducing EDL progression, regardless of the pre-treatment of DOM.


Subject(s)
Proanthocyanidins , Tooth Erosion , Animals , Cariostatic Agents , Cattle , Chlorhexidine/pharmacology , Dentin , Fluorides , Proanthocyanidins/pharmacology , Sodium Fluoride , Titanium , Tooth Erosion/drug therapy
10.
Dent Mater ; 36(12): 1544-1556, 2020 12.
Article in English | MEDLINE | ID: mdl-33012518

ABSTRACT

OBJECTIVE: To evaluate the influence of the addition of functionalized and non-functionalized TiO2 nanostructures on properties of a resin composite. METHODS: TiO2 nanostructures were synthesized and functionalized, using 3-(aminopropyl)triethoxysilane (APTMS) and 3-(trimethoxysilyl)propyl methacrylate (TSMPM). Characterizations were performed with XRD, EDS, TEM, and TGA. Resin composites containing Bis-GMA/TEGDMA, CQ, DABE, and barium-aluminum silicate glass were produced according to TiO2 nanostructure (nanotube or nanoparticle), concentration (0.3 or 0.9 wt%), and functionalization (APTMS or TSMPM). The resin composite without nanostructures was used as control. The amount of fillers was kept constant at 78.3 wt% for all materials. The degree of conversion (DC - at 0 h and 24 h), maximum polymerization rate (Rpmax), and Knoop microhardness (KHN before and after ethanol softening) were evaluated. Data were analyzed with two-way ANOVA with repeated measures and Tukey's HSD (α = 0.05). RESULTS: TGA results demonstrated that functionalizations were effective for both nanostructures. For DC, resin composites, time and interaction effect were significant (p < 0.001). Higher DC was found for 0.3-wt%-functionalized-nanotubes at 24 h. For nanoparticles, only 0.9-wt%-non-functionalized and 0.3-wt%-APTMS-functionalized showed DC similar to the control and all other groups showed higher DC (p < 0.05). Rpmax was higher for 0.3-wt%-APTMS-nanotubes, which corresponded to higher DC after 24 h. The lowest Rpmax occurred for 0.9-wt%-TSMPM-nanotubes, which showed smaller DC at 0 h. For KHN, resin composites, ethanol softening and interaction effect were significant (p < 0.001). KHN decreased after ethanol softening all groups, except for 0.3-wt%-TSMPM-nanotubes, 0.9-wt%-TSMPM-nanotubes, and 0.3-wt%-non-functionalized-nanoparticles. CONCLUSION: The resin with 0.3-wt%-TSMPM-nanotubes showed higher DC after 24 h, while being the most stable material after the ethanol softening. SIGNIFICANCE: The addition of functionalized TiO2 nanostructures in resin-based materials may improve the properties of the material.


Subject(s)
Nanoparticles , Nanotubes , Bisphenol A-Glycidyl Methacrylate , Composite Resins , Materials Testing , Methacrylates , Polyethylene Glycols , Polymethacrylic Acids , Surface Properties , Titanium
11.
Gen Dent ; 68(5): 69-72, 2020.
Article in English | MEDLINE | ID: mdl-32857053

ABSTRACT

This study aimed to evaluate the flexural strength (FS) and modulus of elasticity (ME) of 2 provisional resins at different thicknesses and after different storage periods. A total of 80 specimens were made of 2 provisional restorative materials (n = 40): Dencôr (DC) or Protemp 4 (PT). The specimens in each material group were prepared in 2 different thicknesses (n = 20): 1.5 mm or 2.0 mm. The groups were further subdivided by storage time (n = 10 per material thickness per time): 7 days or 3 months. A 3-point bending test was performed with a universal testing machine. Data were submitted to 3-way analysis of variance followed by a post hoc Tukey test (α = 0.05). Regarding the interaction of material and thickness, the 2.0-mm-thick DC specimens presented a significantly lower mean FS (41.08 MPa) than the other groups (P < 0.05). Regarding the interaction of material and storage time, PT after 3 months presented a significantly higher mean FS (75.51 MPa) than the other groups and periods (P < 0.05). Regardless of the material, the highest mean ME was found in the 1.5-mm-thick group after 3 months (2.24 GPa) (P < 0.05). The lowest ME values were found in the 2.0-mm-thick specimens after both storage times (7 days, 0.88 GPa; 3 months, 1.09 GPa), which were not significantly different from each other (P > 0.05). The correlation between FS and ME was direct and positive (R2 = 0.51; P < 0.001), independently of the variables (material, thickness, and time). Therefore, 2.0-mm-thick PT specimens presented the highest values of FS, mainly after 3 months. The ME was higher after 3 months (1.5-mm-thick specimens), regardless of the material. In addition, the higher the FS, the higher the ME of the material.


Subject(s)
Dental Materials , Materials Testing , Pliability , Stress, Mechanical , Surface Properties
12.
Braz Oral Res ; 34: e053, 2020.
Article in English | MEDLINE | ID: mdl-32578763

ABSTRACT

The objective was to evaluate the compressive strength (CS), diametral tensile strength (DTS), flexural strength (FS), and Knoop microhardness (KH) of different conventional restorative glass-ionomer cements (GICs) and to correlate these mechanical properties (MP) with the stabilization time (ST) of their chemical bonds. Eighteen GICs were tested: Bioglass [B], Chemfil Rock [CR], Equia Forte [EF], Gold Label 2 [GL2], Gold Label 9 [GL9], Glass Ionomer Cement II [GI], Ionglass [IG], Ion Z[ IZ], Ionomaster [IM], Ionofil Plus [IP], Ionostar Plus [IS], Ketac Molar Easymix [KM], Magic Glass [MG], Maxxion R [Ma], Riva Self Cure [R], Vidrion R [V], Vitro Fil [VF] and Vitro Molar [VM]. The mechanical strength tests were performed in a universal testing machine. KH readings were done with a diamond indenter. STs were examined by Fourier Transform Infrared spectroscopy (FTIR). Data were analyzed with ANOVA and Tukey test (p<0.05). The Spearman rank test was used to evaluate the dependence between the MPs and ST results. The highest MP values were EF, GL2, GL9, GI and KM and the lowest for MG, MA, B, VF and IM. The longest ST was for GL2 and the shortest was for B. ST correlated positively with MP. GICs with longer chemical bonds ST are generally stronger and the ST value obtained from FTIR was useful in predicting the strength of GICs tested.


Subject(s)
Glass Ionomer Cements/chemistry , Self-Curing of Dental Resins/methods , Analysis of Variance , Compressive Strength , Flexural Strength , Hardness Tests , Materials Testing , Reference Values , Reproducibility of Results , Spectroscopy, Fourier Transform Infrared , Tensile Strength , Time Factors
13.
Dent Mater ; 36(9): 1190-1200, 2020 09.
Article in English | MEDLINE | ID: mdl-32561117

ABSTRACT

OBJECTIVE: To synthesize a zirconia toughened alumina (ZTA) composite with 70% alumina reinforced by 30% zirconia for dental applications and to characterize its microstructure and optical properties for comparison with the isolated counterpart materials and a first-generation 3Y-TZP. METHODS: Disc-shaped specimens were divided in four groups (n = 70/material): (1) 3YSB-E (first generation 3Y-TZP), (2) Zpex (second generation 3Y-TZP), (3) alumina, and (4) ZTA-Zpex 70/30. After synthesis, ceramic powders were pressed, and green-body samples sintered following a predetermined protocol. Specimens were polished to obtain a mirror surface finish. Apparent density was measured by Archimedes principle. X-ray diffraction (XRD) and scanning electron microscope (SEM) were used to characterize the crystalline content and microstructure. Reflectance tests were performed to determine the contrast-ratio (CR) and translucency-parameter (TP). Mechanical properties were assessed by biaxial flexural strength (BFS) test. All analyses were conducted before and after artificial aging (20 h, 134 °C, 2.2 bar). Optical parameters were evaluated through repeated-measures analysis of variance and Tukey tests (p < 0.05). BFS data were analyzed using Weibull statistics (95% CI). RESULTS: High density values (95-99%) were found for all ceramic materials and SEM images exhibited a dense microstructure. While XRD patterns revealed the preservation of crystalline content in the ZTA composite, an increase in the monoclinic peak was observed for pure zirconias after aging. Significantly higher CR and lower TP values were observed for the ZTA composite, followed by alumina, 3YSB-E, and Zpex. The highest characteristic stress was recorded for 3YSB-E, followed by intermediate values between ZTA and Zpex, and the lowest for alumina. Aging affected the optical and mechanical properties of both zirconias, while remained stable for ZTA composite and alumina. SIGNIFICANCE: The synthesis of experimental 70-30% ZTA composite was successful and its relevance for dental applications relies on its higher masking ability, aging resistance, and strength similar to zirconia.


Subject(s)
Aluminum Oxide , Zirconium , Ceramics , Dental Materials , Materials Testing , Surface Properties , Yttrium
14.
Dent Mater ; 36(3): e85-e92, 2020 03.
Article in English | MEDLINE | ID: mdl-32019690

ABSTRACT

OBJECTIVES: The aim of this study was to determine the physico-mechanical properties of a high viscosity glass ionomer cement (GIC) reinforced with TiO2 nanotubes (TiO2-nt). METHODS: TiO2-nt was incorporated into the GIC powder components (Ketac Molar EasyMix™) in concentrations of 0% (control group), 3%, 5%, 7% by weight. Compressive strength (n = 10/group), three point bending for flexural strength (n = 18/group), microshear bond strength to dentin and failure mode (n = 20/group), and surface roughness and weight loss before and after brushing simulation (30,000 cycles) (n = 8/group) were evaluated. Data were submitted to Shapiro-Wilk, ANOVA, Tukey and Chi-square tests (α ≤ 0.05). RESULTS: Addition of 5% of TiO2-nt into GIC presented the highest values for compressive strength and differed from the control, 3% and 7% groups (p = 0.023). There were no significant differences in flexural strength (p = 0.107) and surface roughness before and after the dental brushing (p = 0.287) among the groups. GIC added with 5% TiO2-nt showed the lowest weight loss values (p = 0.01), whereas the control, 3% or 5% TiO2-nt groups presented similar microshear bond strength values (p ≥ 0.05). The 5% TiO2-nt group featured higher microshear bond strength than the 7% TiO2-nt group (p = 0.034). Cohesive in material was the most representative failure mode for all groups. SIGNIFICANCE: The incorporation of TiO2-nt did not affect GIC's adhesiveness to dentin, but improved its compressive strength at 5%. Furthermore, TiO2-nt decreased the percentage of weight loss after GIC's surface wear.


Subject(s)
Dental Bonding , Nanotubes , Glass Ionomer Cements , Materials Testing , Surface Properties , Titanium
15.
J Prosthodont Res ; 64(4): 408-416, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32059955

ABSTRACT

PURPOSE: To evaluate the shear bond strength (SBS) between Y-TZP and a resin luting agent, after 1 of 2 enhancing strategies with TiO2--nts was applied, either to the resin luting agent or the Y-TZP mass, in different concentrations. METHODS: In the Strategy TiO2-nts on ceramic, the resin luting agent Panavia F2.0™ (Kuraray) and an experimental Y-TZP with added concentrations of TiO2--nts (0%, 1%, 2%, and 5% vol/vol) and a commercial Y-TZP, comprised 5 different groups (n = 10). In the Strategy TiO2-nts on cement, the resin luting agent RelyX U200™ (3 M ESPE) was added with different concentrations of TiO2--nts (0%, 0.3%, 0.6%, 0.9% wt/wt) luted to a commercial Y-TZP, comprising 4 different groups (n = 10). The Y-TZP discs were included in acrylic bases, and a cylinder (3 × 3 mm) of the correspondent luting agent for each respective group was applied over them. After 24 h, specimens were subjected to SBS assessments in a universal testing machine. Field emission scanning electron microscopy and energy dispersive X-ray spectroscopy analyses were also performed on Y-TZP surfaces. Data were analyzed via analysis of variance and Tukey tests (α = 0.05). RESULTS: TiO2-nts on ceramic influenced the bond strength significantly, but not linearly; TiO2-nts on cement did not influence bond strength when analyzed separately, nor in comparison with the first. CONCLUSION: Y-TZP enhancements with TiO2-nts led to a higher SBS with Panavia F2.0, a 5% TiO2--nt concentration presented the highest bond strength. Modified Rely X U200 did not improve SBS.


Subject(s)
Dental Bonding , Nanotubes , Dental Cements , Dental Stress Analysis , Materials Testing , Microscopy, Electron, Scanning , Resin Cements , Shear Strength , Surface Properties , Titanium , Yttrium , Zirconium
16.
Dent Mater ; 36(2): e38-e46, 2020 02.
Article in English | MEDLINE | ID: mdl-31806496

ABSTRACT

OBJECTIVES: A bovine dense hydroxyapatite ceramic (HA) was produced as new biomaterial, however, the production of a material with consistently high flexural strength remains challenging. The objective of this study was to evaluate the effects of ZnO nanoparticles, TiO2 nanoparticles, and TiO2 nanotubes (1%, 2%, and 5% by weight) on the microstructure and flexural strength of a bovine dense hydroxyapatite ceramic (HA). METHODS: Discs (Ø=12.5mm; thickness=1.3mm) were prepared and subjected to X-ray diffraction (XRD), and observation with a field emission scanning electron microscope (FE-SEM), biaxial flexural strength (BFS) testing, and Vickers hardness (VH) testing. The BFS and VH data were subjected to ANOVA and Tukey post-hoc tests (α=0.05) and Weibull analysis. RESULTS: The XRD showed that the addition of nanomaterials caused the formation of a secondary phase when 5% of the ZnO nanoparticles was used, or when all percentages of the TiO2 nanoparticles/nanotubes were used, and the HA crystallographic planes were maintained. Differences were not observed between the higher BFS values obtained with pure HA and those obtained with the 5% addition of TiO2 nanoparticles. However, the results were different compared with the other groups (α=0.05). The results obtained by Weibull analysis revealed that the 1%, 2%, and 5% addition of TiO2 nanotubes, and the 1% and 2% addition of TiO2 nanoparticles decreased the HA characteristic strength (σ0), while the Weibull modulus (m) increased when 5% of TiO2 nanoparticles, 1% and 2% of ZnO nanoparticles, and 2% of TiO2 nanoparticles were added, but with no statistical difference from the pure HA. The 5% addition of ZnO2 nanoparticles decreased the σ0 without changing m. Moreover, the 5% addition of TiO2 nanoparticles resulted in an m closest to that of pure HA. Regarding the VH results, the blend of HA with 1% and 2% addition of TiO2 nanoparticles exhibited the higher values, which were similar between the different addition ratios (p=0.102). Moreover, the addition of 5% TiO2 nanoparticles resulted in higher value compared with pure HA. SIGNIFICANCE: This study demonstrated that the HA blend with 5% of TiO2 nanoparticles has the greatest potential as a bovine HA dense bioceramic reinforcement.


Subject(s)
Nanoparticles , Nanotubes , Zinc Oxide , Animals , Cattle , Ceramics , Durapatite , Materials Testing , Surface Properties , Titanium , X-Ray Diffraction
17.
Braz. dent. sci ; 23(2): 1-9, 2020. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1096543

ABSTRACT

Objective: multidisciplinary treatment has become increasingly common in dental offices and this treatment strategy is based on the achievement of a healthy, harmonious, and pleasant smile. In addition, the development of new ceramic systems and the possibility of making indirect restorations with a low thickness, such as laminates veneers, allowed combining highly satisfactory aesthetic properties, preserving the dental structure through minimally Invasive technique. Case report: this paper describes a multidisciplinary approach involving periodontics and restorative dentistry for the successful, functional, and aesthetic treatment in an adult patient. The digital smile design was performed as a guide to plan the clinical case considering factors such as tooth inclination and position, golden proportion, tooth size and shape. Discussion: based on these concepts, the present work reports, through a clinical case, the restoration of aesthetics and function with ceramic laminates veneers in lithium disilicate, in the case of anatomical correction and diastema closure. Conclusion: overall, the multidisciplinary treatment plan demonstrated to have greater advantages both for the aesthetics and function of the patient, as well as for the work team. During the 24-month follow-up, this case presented great functional and aesthetics results. (AU)


Introdução: o tratamento multidisciplinar tornou-se cada vez mais comum nos consultórios odontológicos, sendo uma estratégia baseada no tratamento da obtenção de um sorriso saudável, harmonioso e agradável. Além disso, o desenvolvimento de novos sistemas cerâmicos e a possibilidade de fazer restaurações indiretas com baixa espessura, como facetas laminadas, permitiram combinar propriedades estéticas altamente satisfatórias, preservando a estrutura dentária com o mínimo desgaste. Caso clínico: este artigo descreve uma abordagem multidisciplinar envolvendo Periodontia e Odontologia restauradora para um tratamento funcional e estético em um paciente adulto. O desenho digital do sorriso foi realizado como um guia para planejar o caso clínico, considerando fatores como inclinação e posição do dente, proporção áurea, tamanho e formato do dente. Discussão: com base nesses conceitos, o presente trabalho relata, através de um caso clínico, a restauração estética e funcional com laminados cerâmicos em dissilicato de lítio para correção anatômica e fechamento de diastemas. Conclusão: em geral, o plano de tratamento multidisciplinar demonstrou ter maiores vantagens tanto para a estética e função do paciente, quanto para a equipe de trabalho. Durante os 24 meses de acompanhamento, esse caso apresentou ótimos resultados funcionais e estéticos. (AU)


Subject(s)
Dental Veneers , Esthetics, Dental
18.
Braz. oral res. (Online) ; 34: e053, 2020. tab, graf
Article in English | LILACS, BBO - Dentistry | ID: biblio-1132666

ABSTRACT

Abstract The objective was to evaluate the compressive strength (CS), diametral tensile strength (DTS), flexural strength (FS), and Knoop microhardness (KH) of different conventional restorative glass-ionomer cements (GICs) and to correlate these mechanical properties (MP) with the stabilization time (ST) of their chemical bonds. Eighteen GICs were tested: Bioglass [B], Chemfil Rock [CR], Equia Forte [EF], Gold Label 2 [GL2], Gold Label 9 [GL9], Glass Ionomer Cement II [GI], Ionglass [IG], Ion Z[ IZ], Ionomaster [IM], Ionofil Plus [IP], Ionostar Plus [IS], Ketac Molar Easymix [KM], Magic Glass [MG], Maxxion R [Ma], Riva Self Cure [R], Vidrion R [V], Vitro Fil [VF] and Vitro Molar [VM]. The mechanical strength tests were performed in a universal testing machine. KH readings were done with a diamond indenter. STs were examined by Fourier Transform Infrared spectroscopy (FTIR). Data were analyzed with ANOVA and Tukey test (p<0.05). The Spearman rank test was used to evaluate the dependence between the MPs and ST results. The highest MP values were EF, GL2, GL9, GI and KM and the lowest for MG, MA, B, VF and IM. The longest ST was for GL2 and the shortest was for B. ST correlated positively with MP. GICs with longer chemical bonds ST are generally stronger and the ST value obtained from FTIR was useful in predicting the strength of GICs tested.


Subject(s)
Self-Curing of Dental Resins/methods , Glass Ionomer Cements/chemistry , Reference Values , Tensile Strength , Time Factors , Materials Testing , Reproducibility of Results , Analysis of Variance , Spectroscopy, Fourier Transform Infrared , Compressive Strength , Flexural Strength , Hardness Tests
19.
J Appl Oral Sci ; 27: e20180297, 2019 May 30.
Article in English | MEDLINE | ID: mdl-31166548

ABSTRACT

INTRODUCTION: Polymer-based composite materials have been proposed as an alternative for single unit restorations, due to their resilient and shock absorbing behavior, in contrast to the brittleness of ceramic materials that could result in failure by fracture. OBJECTIVE: To evaluate the fatigue strength and damage modes of monolithic posterior resin nanoceramic and lithium disilicate glass ceramic crowns. METHODOLOGY: Twenty-six resin nanoceramic (RNC) and lithium disilicate glass ceramic (LD) 2 mm monolithic crowns (n=13) were cemented on composite resin replicas of a prepared tooth and subjected to cyclic load with lithium disilicate indenters for 2 million cycles. Specimens and indenters were inspected every 500,000 cycles and suspended when presenting fractures or debonding. Surviving specimens were embedded in epoxy resin, polished and subsurface damage was analyzed. Specimens presenting fractures or severe subsurface damage were considered as failures. Survival data was subjected to Fisher's exact test; damage modes were subjected to Mann-Whitney test (p<0.05). RESULTS: There were no debonding, cohesive or catastrophic failures. Considering subsurface damage, 53.8% of RNC and 46.2% of LD crowns survived the fatigue test, presenting no statistical difference. Chief damage modes were radial cracks for RNC and inner cone cracks for LD, presenting no statistical difference. CONCLUSIONS: The results suggest that if debonding issues can be resolved, resin nanoceramic figures can be an alternative to posterior crowns. Although distinct, damage modes revealed potential to cause bulk fracture in both glass ceramic and resin nanoceramic crowns.


Subject(s)
Ceramics/chemistry , Crowns , Dental Porcelain/chemistry , Resin Cements/chemistry , Computer-Aided Design , Dental Prosthesis Design , Dental Restoration Failure , Dental Restoration Wear , Dental Restoration, Permanent/methods , Dental Stress Analysis , Humans , Materials Testing , Reproducibility of Results , Statistics, Nonparametric , Surface Properties , Time Factors
20.
J Appl Oral Sci ; 27: e20180449, 2019.
Article in English | MEDLINE | ID: mdl-30994777

ABSTRACT

OBJECTIVE: This study aims to evaluate the effect of sonochemical treatment on the surface of yttria-stabilized tetragonal zirconia (Y-TZP) before and after the final sintering. MATERIAL AND METHODS: Twenty-eight Y-TZP discs were divided into four groups (n=7), according to surface treatment: PRE: pre-sintering sonication with 30% nominal power for 15 min; POS: post-sintering sonication with 30% nominal power for 15 min; JAT: air abrasion with 50-µm alumina particles; and CON: control group with no treatment. The POS and JAT groups were sintered before sonication and the PRE group after sonication. Surface roughness was analyzed using confocal microscopy, after which resin cement cylinders were placed on the surface of the Y-TZP discs and subjected to mechanical microshear bond strength test until fracture. Surface roughness and microshear bond strength values underwent ANOVA and the Tukey tests. RESULTS: The surface roughness values for the PRE group (299.91 nm) and the POS group (291.23 nm) were not significantly different (p≥0.05), statistically, and the surface roughness value of the JAT group (925.21 nm) was higher than those of PRE and POS (p=0.007) groups. The mechanical microshear bond strength test showed that there was no statistically significant difference between the groups (p=0.08). CONCLUSIONS: Therefore, the results showed that sonochemical treatment modifies the Y-TZP surface and is similar to the well-established sandblasting surface treatment regarding the strength of the bond with the resin cement.


Subject(s)
Dental Bonding/methods , Resin Cements/chemistry , Yttrium/chemistry , Zirconium/chemistry , Air Abrasion, Dental , Analysis of Variance , Materials Testing , Reference Values , Reproducibility of Results , Shear Strength , Statistics, Nonparametric , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...