Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Clin Ophthalmol ; 17: 1629-1638, 2023.
Article in English | MEDLINE | ID: mdl-37304333

ABSTRACT

Dry eye disease (DED) is a multifactorial ocular surface disorder characterized by loss of tear film homeostasis with associated ocular symptoms, like dryness, foreign body sensation, and inflammation. Numerous reports confirm an increase in dry eye symptoms after cataract surgery. DED also significantly disturbs preoperative biometric measurements, mainly by changes in keratometry measurements. The purpose of this study is to evaluate the effect of DED on biometric measurements before cataract surgery and postoperative refractive errors. PubMed database was searched for keywords: cataract surgery, dry eye disease, refractive error, refractive outcomes, keratometry, and biometry. Four clinical studies evaluating the effect of DED on refractive errors were included. In all studies, biometry was performed before and after dry eye treatment, and the mean absolute error was compared. Various substances have been used to treat dry eye, such as cyclosporin A, liftitegrast, and loteprednol. The refractive error was significantly lower after treatment in all studies. The results unanimously indicate that refractive errors can be reduced by proper treatment of DED before cataract surgery.

2.
Cancers (Basel) ; 14(11)2022 May 30.
Article in English | MEDLINE | ID: mdl-35681692

ABSTRACT

Hypo-fractionated stereotactic body radiation therapy (SBRT) is an effective treatment for prostate cancer (PCa). Although many studies have investigated the effects of SBRT on the prostate and adjacent organs, little is known about the effects further out-of-field. The aim of this study was to investigate, both in vitro and in a quasi-humanoid phantom, the biological effects (using a dose-scaling approach) of radiation in the out-of-field peripheral organs delivered by 6 MV volumetric modulated arc therapy (VMAT) SBRT in a prostate cancer model. Healthy prostate cells were irradiated in a phantom at locations corresponding to the prostate, intestine, lung, thyroid, and brain. Seven 10 Gy fractions of VMAT SBRT were delivered to the target in a single session without intermission (scaled-up method). Radiochromic films were used to measure the doses. The radiobiological response was assessed by measuring DNA breaks, the cell survival fraction, and differences in gene expression profile. Our results showed a strong, multiparametric radiobiological response of the cells in the prostate. Outside of the radiation field, the highest doses were observed in the intestine and lung. A small increase (not statistically significant) in DNA damage and cell death was observed in the intestines. Several gene groups (cell cycle, DNA replication) were depleted in the lung and thyroid (DNA replication, endocytosis), but further analysis revealed no changes in the relevant biological processes. This study provides extensive evidence of the types and extent of radiobiological responses during VMAT SBRT in a prostate cancer model. Additional research is needed to determine whether the radiobiological effects observed in the peripheral organs are validated in a clinical context.

3.
Life (Basel) ; 12(5)2022 Apr 23.
Article in English | MEDLINE | ID: mdl-35629296

ABSTRACT

The aim of the study was to determine the influence of a key treatment plan and beam parameters on overall dose distribution and on doses in organs laying in further distance from the target during prostate SBRT. Multiple representative treatment plans (n = 12) for TrueBeam and CyberKnife were prepared and evaluated. Nontarget doses were measured with anionization chamber, in a quasi-humanoid phantom at four sites corresponding to the intestines, right lung, thyroid, and head. The following parameters were modified: radiotherapy technique, presence or not of a flattening filter, degree of modulation, and use or not of jaw tracking function for TrueBeam and beam orientation set-up, optimization techniques, and number of MUs for CyberKnife. After usual optimization doses in intestines (near the target) were 0.73% and 0.76%, in head (farthest from target) 0.05% and 0.19% for TrueBeam and CyberKnife, respectively. For TrueBeam the highest peripheral (head, thyroid, lung) doses occurred for the VMAT with the flattening filter while the lowest for 3DCRT. For CyberKnife the highest doses were for gantry with caudal direction beams blocked (gantry close to OARs) while the lowest was the low modulated VOLO optimization technique. The easiest method to reduce peripheral doses was to combine FFF with jaw tracking and reducing monitor units at TrueBeam and to avoid gantry position close to OARs together with reduction of monitor units at CyberKnife, respectively. The presented strategies allowed to significantly reduce out-of-field and nontarget doses during prostate radiotherapy delivered with TrueBeam and CyberKnife. A different approach was required to reduce peripheral doses because of the difference in dose delivery techniques: non-coplanar using CyberKnife and coplanar using TrueBeam, respectively.

4.
Radiol Oncol ; 56(2): 259-266, 2022 03 28.
Article in English | MEDLINE | ID: mdl-35344646

ABSTRACT

BACKGROUND: Hypofractionated stereotactic body radiation therapy (SBRT) for prostate cancer (PCa) can be delivered with the robot-assisted CyberKnife (CK) system or on a linear accelerator using dynamic intensity-modulated radiotherapy (IMRT) or volumetric arc radiotherapy (VMAT). This retrospective study was performed to determine whether CK offers better dose distribution than IMRT and/or VMAT. MATERIALS AND METHODS: Treatment plans for three techniques were prepared using the same treatment parameters (36.35 Gy, 7.25 Gy/fr). We evaluated target coverage, conformity index (CI), homogeneity index (HI), gamma index (GI), and organs at risk (OAR) constraints. RESULTS: The mean planning target volume (PTV) dose for CK (39.58 Gy) was significantly greater than VMAT or IMRT (both 36.25 Gy). However, CK resulted in a wider dose range (31.48 to 45.89 Gy) vs. VMAT and IMRT (34.6-38.76 Gy). The mean dose to the rectum (V36Gy, mm3) was significantly lower (p < 0.001) in the CK plans (219.78 vs. 519.59 and 422.62, respectively). The mean bladder dose (V37Gy, mm3) was significantly greater for CK (3256 vs. 1090.75 for VMAT and 4.5 for IMRT (p < 0.001). CK yielded significantly better CI (1.07 vs. 1.17 and 1.25 for VMAT and IMRT, respectively; p < 0.01) and HI values (1.27 vs. 1.07 and 1.04; p < 0.01). GI values for the δd = 3mm, δ% = 3% criteria were 99.86 (VMAT), 99.07 (IMRT) and 99.99 (CK). For δd = 2mm, δ% = 2%, the corresponding values were 98.3, 93.35, and 97.12, respectively. CONCLUSIONS: For most variables, CK was superior to both VMAT and IMRT. However, dynamic IMRT techniques, especially VMAT, do not differ significantly from CK plans and are therefore acceptable alternatives to CyberKnife.


Subject(s)
Prostatic Neoplasms , Radiotherapy, Intensity-Modulated , Humans , Male , Particle Accelerators , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies
5.
J Appl Clin Med Phys ; 23(4): e13514, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35104047

ABSTRACT

Our understanding of low dose, out-of-field radiation and their radiobiological effects are limited, in part due to the rapid technological advances in external beam radiotherapy, especially for non-coplanar and dynamic techniques. Reliable comparisons of out-of-field doses produced by advanced radiotherapy techniques are difficult due to the limitations of commercially available phantoms. There is a clear need for a functional phantom to accurately measure the dosimetric and radiobiological characteristics of out-of-field doses, which would in turn allow clinicians and medical physicists to optimize treatment parameters. We designed, manufactured, and tested the performance of a quasi-humanoid (Q-H) adult phantom. To test the physics parameters, we used computed tomography (CT) scans of assembled Q-H phantom. Static open field and dynamic techniques were measured both in- and out-of-field with ionization chambers and radiochromic films for two configurations (full solid and with water-filled containers). In the areas simulating soft tissues, lung, and bones, median Hounsfield units and densities were, respectively: 129.8, -738.7, 920.8 HU and 1.110, 0.215, 1.669 g/cm3 . Comparison of the measured to treatment planning systems (TPS) in-field dose values for the sample volumetric arc therapy (VMAT) (6 MV flattening filter-free (FFF)) plan, 96.4% of analyzed points passed the gamma evaluation criteria (L2%/2 mm, threshold (TH) 10%) and less than 1.50% for point dose verification. In the two phantom configurations: full poly(methyl) methacrylate (PMMA) and with water container, the off-axis median doses for open field, relative to the central axis of the beam (CAX) were similar, respectively: 0.900% versus 0.907% (15 cm distance to CAX); 0.096% versus 0.120% (35 cm); 0.018% versus 0.018% (52 cm); 0.009% versus 0.008% (74 cm). For VMAT 6 MV FFF, doses relative the CAX were, respectively: 0.667% (15 cm), 0.062% (35 cm), 0.019% (52 cm), 0.016% (74 cm). The Q-H phantom meets the International Commission on Radiation Units and Measurements (ICRU) and American Association of Physicists in Medicine (AAPM) recommended phantom criteria, providing medical physicists with a reliable, comprehensive system to perform dose calculation and measurements and to assess the impact on radiobiological response and on the risk of secondary tumor induction.


Subject(s)
Radiotherapy, Intensity-Modulated , Adult , Humans , Phantoms, Imaging , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Water
6.
J Pers Med ; 11(12)2021 Dec 06.
Article in English | MEDLINE | ID: mdl-34945783

ABSTRACT

Few studies have directly compared passive scattering (PS) to intensity-modulated proton therapy (IMPT) in the delivery of ultra-hypofractionated proton beams to the localized prostate cancer (PCa). In this preliminary study involving five patients previously treated with CyberKnife, treatment plans were created for PS and IMPT (36.25 CGE in five fractions with two opposing fields) to compare the dosimetric parameters to the planning target volume (PTV) and organs-at-risk (OAR: rectum, bladder, femoral heads). Both plans met the acceptance criteria. Significant differences were observed in the minimum and maximum doses to the PTV. The mean dose to the PTV was lower for PS (35.62 ± 0.26 vs. 37.18 ± 0.14; p = 0.002). Target coverage (D98%) was better for IMPT (96.79% vs. 99.10%; p = 0.004). IMPT resulted in significantly lower mean doses to the rectum (16.75 CGE vs. 6.88 CGE; p = 0.004) and bladder (17.69 CGE vs. 5.98 CGE p = 0.002). High dose to the rectum (V36.25 CGE) were lower with PS, but not significantly opposite to high dose to the bladder. No significant differences were observed in mean conformity index values, with a non-significant trend towards higher mean homogeneity index values for PS. Non-significant differences in the gamma index for both fields were observed. These findings suggest that both PS and IMPT ultra-hypofractionated proton therapy for PCa are highly precise, offering good target coverage and sparing of normal tissues and OARs.

7.
BMC Ophthalmol ; 19(1): 118, 2019 May 24.
Article in English | MEDLINE | ID: mdl-31126280

ABSTRACT

BACKGROUND: To examine morphological and functional results after pars plana vitrectomy (PPV) with sulfur hexafluoride (SF6) gas tamponade due to macula-on and macula-off rhegmatogenous retinal detachment (RRD) during 6 months of the follow-up. METHODS: The study included 62 eyes that underwent successful PPV with SF6 tamponade with macula-on (34 eyes) and macula-off (28 eyes) RRD preoperatively. The best-corrected visual acuity (BCVA), Amsler test, M-charts, optical coherence tomography (OCT) and microperimetry were performed at 1, 3 and 6 months postoperatively. RESULTS: Results of the Amsler test were abnormal postoperatively in 54% of the patients in the group with macula-off and in 32% of the patients with macula-on RRD. Horizontal M-charts improved significantly from 0.33 to 0.2, vertical M-charts- from 0.29 to 0.17 during 6 months of the follow-up. There was a significant increase in the central retinal thickness (CRT) and average thickness (AT) between follow-up examinations only in the macula-off group. 29 of 62 eyes (47%) after surgery (equally with macula-on and macula-off RRD) showed morphological changes in OCT in the macular region, as epiretinal membrane, macular edema, subretinal fluid or alterations of the outer layers of the retina. The average threshold in microperimetry increased significantly within both groups during the follow-up. CONCLUSION: Both horizontal and vertical M-charts scores, as were as microperimetry sensitivity improved significantly during the 6 months of the follow-up both in macula-on and macula-off group. Although PPV with SF6 gas tamponade was successful, almost half of eyes revealed anatomical changes in the macular region in OCT both with macula-on and macula-off group. TRIAL REGISTRATION: Current Controlled Trials NCT03902795 registered on 03/04/2019. Retrospectively registered.


Subject(s)
Endotamponade/methods , Macula Lutea/pathology , Retinal Detachment/surgery , Vitrectomy/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Retinal Detachment/pathology , Retinal Detachment/physiopathology , Retrospective Studies , Sulfur Hexafluoride/administration & dosage , Tomography, Optical Coherence/methods , Vision Disorders/physiopathology , Visual Acuity/physiology
8.
J Ophthalmol ; 2017: 6232151, 2017.
Article in English | MEDLINE | ID: mdl-28553550

ABSTRACT

Purpose. To evaluate visual and safety outcomes of 23-gauge (G) pars plana vitrectomy (PPV) with application of perfluorocarbon liquid (PFCL) for intraoperative protection of the macula during intraocular foreign body (IOFB) removal. Methods. Retrospective study of 42 patients who underwent 23 G PPV for IOFB removal from posterior segment with intraoperative PFCL application for the macula shielding. Collected data included corrected distance visual acuity (CDVA), size of IOFB, and complication rate. The mean follow-up period was 12 months. Results. The mean preoperative CDVA was 0.54 logMAR (SD 0.46), and the final mean CDVA was 0.68 logMAR (SD 0.66). All IOFBs were metallic with mean dimensions of 4.6 mm × 2.1 mm. Twenty-two IOFBs were removed through the corneal tunnel and 20 IOFBs through the sclerotomy. No intraoperative iatrogenic lesion of the macula was observed. As a tamponade, silicon oil was applied in 31 eyes, SF6 gas in 5 eyes, air in 4 eyes, and 2 eyes required no tamponade. Secondary retinal detachment was observed in 17% of cases, but at the end of the follow-up, all the retinas were attached. Conclusion. PFCL application during PPV is a safe method of protecting the macula from unexpected falling of the metallic IOFB during its removal.

9.
J Ophthalmol ; 2017: 5084319, 2017.
Article in English | MEDLINE | ID: mdl-28163930

ABSTRACT

Purpose. To evaluate functional and anatomical results of pars plana vitrectomy (PPV) in the retinal detachment (RD) followed by severe eye trauma. Methods. Retrospective analysis of medical records of forty-one consecutive patients treated with 23-gauge PPV due to traumatic RD. Age, gender, timing of PPV, visual acuity, and presence of intraocular foreign body (IOFB) and proliferative vitreoretinopathy (PVR) were included in the analysis. Results. Mean age of patients was 47 years; the majority of patients were men (88%). Closed globe injury was present in 21 eyes and open globe injury in 20 eyes (IOFB in 13 eyes, penetration injury in 4 eyes, and eye rupture in 3 eyes). Mean follow-up period was 14 months; mean timing of PPV was 67 days. Twenty-seven (66%) eyes had a functional success; 32 eyes (78%) had anatomical success. As a tamponade silicone oil was used in 33 cases and SF6 gas in 8 cases. Conclusions. Severe eye injuries are potentially devastating for vision, but vitreoretinal surgery can improve anatomical and functional outcomes. Among analysed pre- and intra- and postoperative factors, absence of PVR, postoperative retinal attachment, and silicone oil as a tamponade were related to significantly improved visual acuity.

10.
Med Phys ; 44(4): 1538-1544, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28196271

ABSTRACT

AIM: To evaluate the impact of radiochromic film positioning relative to the central beam axis (CAX) in proton beam therapy. Secondarily, to compare the dosimetric measurements obtained by RTQA and EBT film and to compare these to the doses calculated by the treatment planning system (TPS). METHODS: The EBT and RTQA dosimetric radiochromic films were immersed in a water phantom and irradiated with a proton beam. The films were placed parallel to the CAX and at a 5° angle on the horizontal plane to assess the effect of film inclination on Bragg peak profiles. Calibration was performed by irradiating small pieces of film at doses ranging from 0.0 Gy to 3.5 Gy in increments of 0.5 Gy. The TPS was used to create treatment plans for two different geometrical targets (cylindrical and cuboidal). After irradiation, all film pieces were scanned on a flatbed scanner and red channel data were extracted from the 48-bit RGB images using ImageJ, Photoshop, Origin8, and Excel software. The dose distributions from the irradiated films were compared to the dose obtained from the TPS. Bragg peak profiles were abstracted from the irradiated films and compared. RESULTS: The dosimetric measurements obtained by both EBT and RTQA positioned at a 5° to the CAX closely matched the dose calculated by the TPS for the cylindrical target. In contrast, dose distributions measured in the cuboidal targets were less precise. Gamma index (GI) values (3%/3 mm acceptance criteria for isodose >90% of dose) were 99.8% and 93% for EBT film placed at a 5° angle versus 47.1% and 80.8% for EBT film parallel to the beam. The dosimetric measurements in RTQA film positioned parallel to the CAX showed GI values with <27% agreement with the TPS-calculated dose. CONCLUSION: Our finding show that RTQA film can be used to accurately measure doses in the proton beam at the region of Bragg peak; however, to obtain the most accurate readings, the film should be positioned at a small angle to the CAX.


Subject(s)
Film Dosimetry/methods , Calibration , Phantoms, Imaging , Proton Therapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
11.
Rep Pract Oncol Radiother ; 19(1): 12-8, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24936315

ABSTRACT

AIM: To present the results obtained using radiochromic films EBT and RTQA 1010P for the reconstruction the dose distributions for targets irradiated by proton beam and modified by wax boluses. BACKGROUND: In Medico-Technical Complex at the Joint Institute for Nuclear Research in Dubna implemented technology of wax boluses. MATERIALS AND METHODS: Wax boluses are easier to make and they give better dose distributions than boluses made from modeling clay previously used at our center. We irradiated two imaginary targets, one shaped as a cylinder and the other one as two cuboids. The evaluated calibration curve was used for calculation of the dose distributions measured by the EBT and RTQA radiochromic film. In both cases, the measured dose distributions were compared to the dose distributions calculated by the treatment planning system (TPS). We also compared dose distributions using three different conformity indices at a 95% isodose. RESULTS: Better target coverage and better compliance of measurements (semiconductor detectors and radiochromic films) with calculated doses was obtained for cylindrical target than for cuboidal target. The 95% isodose covered well the tumor for both target shapes, while for cuboidal target larger volume around the target received therapeutic dose, due to the complicated target shape. The use wax boluses provided to be effective tool in modifying proton beam to achieve appropriate shape of isodose distribution. CONCLUSION: EBT film yielded the best visual matching. Both EBT and RTQA films confirmed good conformity between calculated and measured doses, thus confirming that wax boluses used to modify the proton beam resulted in good dose distributions.