Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Sports Med ; 52(3): 721-729, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38343192

ABSTRACT

BACKGROUND: No description exists in the literature about the normal evolution of tendon graft after a lateral ankle ligament (LAL) reconstruction. PURPOSE: To assess the magnetic resonance imaging (MRI) characteristics and the evolution of the tendon graft during different moments in the follow-up after an endoscopic reconstruction of the LAL. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This prospective study included 37 consecutive patients who underwent an endoscopic reconstruction of the LAL with an autograft using the gracilis tendon to treat chronic ankle instability (CAI) resistant to nonoperative treatment (CAI group) and 16 patients without ankle instability (control group). All patients in the CAI group underwent a postoperative assessment at 6, 12, and 24 months using the Karlsson score and MRI examination. Only patients with good and excellent results were included in the study. Graft assessment consisted of qualitative measurements and quantitative evaluations of the reconstructed anterior talofibular ligament (RATFL) and reconstructed calcaneofibular ligament (RCFL), including signal-to-noise quotient (SNQ) and contrast-to-noise quotient (CNQ) measurements in proton density-fat suppressed (PD-FS) and T1-weighted sequences. The analysis of variance test was used to compare the SNQ and the CNQ at different time points for each sequence. RESULTS: The MRI signal at 6 months was increased compared with that of the control group. Next, a significant signal decrease from 6 to 24 months was noted on PD-FS and T1-weighted images. SNQ measurements on PD-FS weighted images for both the RATFL and the RCFL demonstrated a significantly higher signal (P < .01 and P = .01, respectively) at 6 months compared with that of the control group. Subsequently, the signal decreased from 6 to 24 months. Similarly, CNQ measurements on PD-FS weighted images for both the RATFL and the RCFL demonstrated a significantly higher signal (P < .01 and P < .01, respectively) at 6 months compared with that of the control group. Subsequently, the signal decreased from 6 to 24 months. CONCLUSION: The present study demonstrated an evolution of the MRI characteristics, suggesting a process of graft maturation toward ligamentization. This is important for clinical practice, as it suggests an evolution in graft properties and supports the possibility of creating a viable ligament.


Subject(s)
Joint Instability , Lateral Ligament, Ankle , Humans , Lateral Ligament, Ankle/diagnostic imaging , Lateral Ligament, Ankle/surgery , Ankle , Cohort Studies , Prospective Studies , Ligaments/diagnostic imaging , Ligaments/surgery , Joint Instability/diagnostic imaging , Joint Instability/surgery , Magnetic Resonance Imaging , Protons , Tendons/diagnostic imaging , Tendons/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...