1.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38682165

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation. Confirmation of PVI can be challenging due to the presence of far-field electrograms (EGMs) and sometimes requires additional pacing manoeuvres or mapping. This prospective multicentre study assessed the agreement between a previously trained automated algorithm designed to determine vein isolation status with expert opinion in a real-world clinical setting. METHODS AND RESULTS: Consecutive patients scheduled for PVI were recruited at four centres. The ECGenius electrophysiology (EP) recording system (CathVision ApS, Copenhagen, Denmark) was connected in parallel with the existing system in the laboratory. Electrograms from a circular mapping catheter were annotated during sinus rhythm at baseline pre-ablation, time of isolation, and post-ablation. The ground truth for isolation status was based on operator opinion. The algorithm was applied to the collected PV signals off-line and compared with expert opinion. The primary endpoint was a sensitivity and specificity exceeding 80%. Overall, 498 EGMs (248 at baseline and 250 at PVI) with 5473 individual PV beats from 89 patients (32 females, 62 ± 12 years) were analysed. The algorithm performance reached an area under the curve (AUC) of 92% and met the primary study endpoint with a sensitivity and specificity of 86 and 87%, respectively (P = 0.005; P = 0.004). The algorithm had an accuracy rate of 87% in classifying the time of isolation. CONCLUSION: This study validated an automated algorithm using machine learning to assess the isolation status of pulmonary veins in patients undergoing PVI with different ablation modalities. The algorithm reached an AUC of 92%, with both sensitivity and specificity exceeding the primary study endpoints.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Machine Learning , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Prospective Studies , Aged , Electrophysiologic Techniques, Cardiac/methods , Treatment Outcome , Reproducibility of Results , Predictive Value of Tests , Action Potentials , Heart Rate , Algorithms , Signal Processing, Computer-Assisted
2.
Article in English | MEDLINE | ID: mdl-38609733

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

3.
PLoS One ; 19(4): e0301753, 2024.
Article in English | MEDLINE | ID: mdl-38578782

ABSTRACT

BACKGROUND: Atrial arrhythmias (AA) commonly affect patients with cardiac amyloidosis (CA) and are a contributing risk factor for the development of heart failure (HF). This study sought to investigate the long-term efficacy and impact of catheter ablation on HF progression in patients with CA and AA. METHODS: Thirty-one patients with CA and AA undergoing catheter ablation were retrospectively included (transthyretin-ATTR CA 61% and light chain-AL CA 39%). AA subtypes included atrial fibrillation (AFib) in 22 (paroxysmal in 10 and persistent in 12), atrial flutter (AFl) in 17 and atrial tachycardia (AT) in 11 patients. Long-term AA recurrence rates were evaluated along with the impact of sinus rhythm (SR) maintenance on HF and mortality. RESULTS: AA recurrence was observed in 14 patients (45%) at a median of 3.5 months (AFib n = 8, AT n = 6, AFl = 0). Post-cardioversion, medical therapy or catheter ablation, 10 patients (32%) remained in permanent AA. Over a median follow-up of 19 months, all-cause mortality was 39% (n = 12): 3 with end-stage HF, 5 due to late complications of CA, 1 sudden cardiac death, 1 stroke, 1 COVID 19 (and one unknown). With maintenance of SR following catheter ablation, significant reductions in serum creatinine and natriuretic peptide levels were observed with improvements in NYHA class. Two patients required hospitalization for HF in the SR maintenance cohort compared to 5 patients in the AA recurrence cohort (p = 0.1). All 3 patients with deaths secondary to HF had AA recurrence compared to 11 out of the 28 patients whom were long-term survivors or deaths not related to HF (p = 0.04). All-cause mortality was not associated with AA recurrence. CONCLUSION: This study demonstrates moderate long-term efficacy of SR maintenance with catheter ablation for AA in patients with CA. Improvements in clinical and biological status with positive trends in HF mortality are observed if SR can be maintained.


Subject(s)
Amyloidosis , Atrial Fibrillation , Catheter Ablation , Heart Failure , Tachycardia, Supraventricular , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Retrospective Studies , Treatment Outcome , Neoplasm Recurrence, Local/surgery , Heart Failure/complications , Heart Failure/surgery , Amyloidosis/complications , Amyloidosis/surgery , Catheter Ablation/adverse effects
4.
J Clin Med ; 13(5)2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38592135

ABSTRACT

Sudden cardiac death (SCD) accounts for a substantial proportion of mortality in heart failure with reduced ejection fraction (HFrEF), frequently triggered by ventricular arrhythmias (VA). This review aims to analyze the pathophysiological mechanisms underlying VA and SCD in HFrEF and evaluate the effectiveness of guideline-directed medical therapy (GDMT) in reducing SCD. Beta-blockers, angiotensin receptor-neprilysin inhibitors, and mineralocorticoid receptor antagonists have shown significant efficacy in reducing SCD risk. While angiotensin-converting enzyme inhibitors and angiotensin receptor blockers exert beneficial impacts on the renin-angiotensin-aldosterone system, their direct role in SCD prevention remains less clear. Emerging treatments like sodium-glucose cotransporter 2 inhibitors show promise but necessitate further research for conclusive evidence. The favorable outcomes of those molecules on VA are notably attributable to sympathetic nervous system modulation, structural remodeling attenuation, and ion channel stabilization. A multidimensional pharmacological approach targeting those pathophysiological mechanisms offers a complete and synergy approach to reducing SCD risk, thereby highlighting the importance of optimizing GDMT for HFrEF. The current landscape of HFrEF pharmacotherapy is evolving, with ongoing research needed to clarify the full extent of the anti-arrhythmic benefits offered by both existing and new treatments.

6.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
7.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38646926

ABSTRACT

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Catheter Ablation/methods , Treatment Outcome , Pulmonary Veins/surgery , Female , Male , Recurrence , Europe , Middle Aged
8.
Arch Cardiovasc Dis ; 117(4): 249-254, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38494400

ABSTRACT

BACKGROUND: Pulsed field ablation has recently emerged as an interesting non-thermal energy for atrial fibrillation ablation. At a time of rapid spread of this technology, there is still a lack of prospective real-life data. AIM: To describe multicentre prospective safety and 1-year efficacy data in three of the first French centres to use pulsed field ablation. METHODS: All consecutive patients undergoing a first pulsed field ablation were included prospectively. The primary outcome was freedom from documented atrial arrhythmia. The safety endpoint was a composite of major adverse events. Univariate and multivariable analyses, including patient and procedural characteristics, were performed to identify factors predictive of recurrence. RESULTS: Between May 2021 and June 2022, 311 patients were included (paroxysmal atrial fibrillation in 53%, persistent atrial fibrillation in 35% and long-standing persistent atrial fibrillation in 11%). Additional non-pulmonary vein pulsed field ablation applications were performed in 104/311 patients. One-year freedom from arrhythmia recurrence was 77.6% in the overall population and was significantly higher in patients with paroxysmal atrial fibrillation (88.4%) compared with patients with persistent atrial fibrillation (69.7%; P<0.001) and those with long-standing persistent atrial fibrillation (49.0%; P<0.001). The major complication rate was 2.6% (tamponade in four patients, stroke in two patients and coronary spasm in one patient). Besides the usual predictors of recurrences (left atrium size, CHA2DS2-VASc score, type of atrial fibrillation), the presence of atrial fibrillation at procedure start was independently associated with arrhythmia recurrence (hazard ratio: 2.04, 95% confidence interval: 1.10-3.77). CONCLUSION: In this prospective multicentre real-world study, pulsed field ablation for atrial fibrillation ablation seems to be associated with a good safety profile and rather favourable acute and 1-year success rates.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Prospective Studies , Treatment Outcome , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
9.
Article in English | MEDLINE | ID: mdl-38430087

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.

10.
Heart Rhythm ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38336193

ABSTRACT

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

11.
Arch Cardiovasc Dis ; 117(3): 224-231, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38302391

ABSTRACT

Sustainability in healthcare, particularly within the domain of cardiac electrophysiology, assumes paramount importance for the near future. The escalating environmental constraints encountered necessitate a proactive approach. This position paper aims to raise awareness among physicians, spark critical inquiry and identify potential solutions to enhance the sustainability of our practice. Reprocessing of single-use medical devices has emerged as a potential solution to mitigate the environmental impact of electrophysiology procedures, while also offering economic advantages. However, reprocessing remains unauthorized in certain countries. In regions where it is possible, stringent regulatory standards must be adhered to, to ensure patient safety. It is essential that healthcare professionals, policymakers and manufacturers collaborate to drive innovation, explore sustainable practices and ensure that patient care remains uncompromised in the face of environmental challenges. Ambitious national/international programmes of disease prevention should be the cornerstone of the strategy. It is equally vital to implement immediate actions, as delineated in this position paper, to bring about tangible change quickly.


Subject(s)
Cardiology , Defibrillators, Implantable , Pacemaker, Artificial , Humans , Arrhythmias, Cardiac/therapy , Societies, Medical
12.
Eur Heart J Case Rep ; 8(2): ytae085, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38405199

ABSTRACT

Background: Ablation of persistent atrial fibrillation (AF) remains challenging, with atrial substrate modification often being performed as an adjunct to pulmonary vein isolation (PVI). Pulsed field ablation (PFA) is a novel ablation modality that carries a favourable safety profile, which could facilitate complex procedures. Case summary: We present the case of a 60-year-old male undergoing catheter ablation for symptomatic persistent AF. The procedure was performed with the Farapulse™ PFA system in a stepwise manner, including PVI and linear lesions for the isolation of the posterior left atrial wall and the ablation of the mitral isthmus. The final step of the procedure included the ablation of areas exhibiting spatiotemporal electrogram dispersion, identified with the help of artificial intelligence-based software (VX1, Volta Medical) in both atria. Sinus rhythm was restored after the abolition of an electrogram dispersion zone in the right atrium. The procedure was carried out without any complications. Discussion: Complex ablation procedures for persistent AF can be successfully performed with PFA. In the context of such extensive ablation strategies, PFA is an attractive energy source, given its non-thermal nature that is known to prevent damage to surrounding tissue and result in less chronic fibrosis. However, caution should be exercised to avoid excessive ablation when using the currently available multispline PFA catheter, as it may inadvertently target adjacent areas of healthy myocardium.

13.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38340118

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Registries , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Male , Female , Middle Aged , Catheter Ablation/methods , Aged , Europe , Treatment Outcome , Recurrence , Reoperation/statistics & numerical data
14.
ESC Heart Fail ; 11(2): 1228-1235, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38234123

ABSTRACT

AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re-hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric parameters which aims to predict HF episodes. It provides an index which can be monitored remotely, allowing pre-emptive treatment of congestion to prevent acute decompensation. We aim to assess the impact and security of pre-emptive HF management, guided by the HeartLogic™ index. METHODS AND RESULTS: The HeartLogic™ France Cohort Study is an investigator-initiated, prospective, multi-centre, non-randomized study. Three hundred ten patients with a history of HF (left ventricular ejection fraction ≤40%; or at least one episode of clinical HF with elevated NT-proBNP ≥450 ng/L) and implanted with a cardioverter defibrillator enabling HeartLogic™ index calculation will be included across 10 French centres. The HeartLogic™ index will be monitored remotely for 12 months and in the event of a HeartLogic™ index ≥16, the local investigator will contact the patient for assessment and adjust HF treatment as necessary. The primary endpoint is unscheduled hospitalization for HF. Secondary endpoints are all-cause mortality, cardiovascular death, HF-related death, unscheduled hospitalizations for ventricular or atrial arrhythmia and HeartLogic™ index evolution over time. Blood samples will be collected for biobanking, and quality of life will be assessed. Finally, the safety of a HeartLogic™-triggered strategy for initiating or increasing diuretic therapy will be assessed. A blind and independent committee will adjudicate the events. CONCLUSIONS: The HeartLogic™ France Cohort Study will provide robust real-world data in a cohort of HF patients managed with the HeartLogic™ algorithm allowing pre-emptive treatment of heart failure exacerbations.


Subject(s)
Heart Failure , Quality of Life , Humans , Cohort Studies , Stroke Volume , Prospective Studies , Biological Specimen Banks , Ventricular Function, Left , Algorithms
15.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38291925

ABSTRACT

A significant proportion of patients who suffer from atrial fibrillation (AF) and are in need of thromboembolic protection are not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has not improved sufficiently despite the availability of direct oral anticoagulants which are associated with less major bleeding than vitamin K antagonists. Multiple reasons account for this, including bleeding events or ischaemic strokes whilst on anticoagulation, a serious risk of bleeding events, poor treatment compliance despite best educational attempts, or aversion to drug therapy. An alternative interventional therapy, which is not associated with long-term bleeding and is as effective as vitamin K anticoagulation, was introduced over 20 years ago. Because of significant improvements in procedural safety over the years, left atrial appendage closure, predominantly achieved using a catheter-based, device implantation approach, is increasingly favoured for the prevention of thromboembolic events in patients who cannot achieve effective anticoagulation. This management strategy is well known to the interventional cardiologist/electrophysiologist but is not more widely appreciated within cardiology or internal medicine. This article introduces the devices and briefly explains the implantation technique. The indications and device follow-up are more comprehensively described. Almost all physicians who care for adult patients will have many with AF. This practical guide, written within guideline/guidance boundaries, is aimed at those non-implanting physicians who may need to refer patients for consideration of this new therapy, which is becoming increasingly popular.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Physicians , Stroke , Thromboembolism , Adult , Humans , Stroke/prevention & control , Stroke/complications , Left Atrial Appendage Closure , Consensus , Hemorrhage/chemically induced , Hemorrhage/prevention & control , Anticoagulants/adverse effects , Thromboembolism/etiology , Thromboembolism/prevention & control , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Vitamin K , Atrial Appendage/surgery , Treatment Outcome
16.
Heart Rhythm ; 2024 Jan 28.
Article in English | MEDLINE | ID: mdl-38290688

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE: The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS: Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS: Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION: PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.

17.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38227804

ABSTRACT

AIMS: Although guidelines for the management of atrial fibrillation (AF) are regularly published, many controversial issues remain, limiting their implementation. We aim to describe current clinical practice among European Heart Rhythm Association (EHRA) community according to last guidelines. METHODS AND RESULTS: A 30 multiple-choice questionnaire covering the most controversial topics related to AF management was distributed through the EHRA Research Network, National Societies, and social media between January and February 2023. One hundred and eighty-one physicians responded the survey, 61% from university hospitals. Atrial fibrillation screening in high-risk patients is regularly performed by 57%. Only 42% has access to at least one programme aiming at diagnosing/managing comorbidities and lifestyle modifications, with marked heterogeneity between countries. Direct oral anticoagulants are the preferred antithrombotic (97%). Rhythm control is the preferred strategy in most AF phenotypes: symptomatic vs. asymptomatic paroxysmal AF (97% vs. 77%), low vs. high risk for recurrence persistent AF (90% vs. 72%), and permanent AF (20%). I-C drugs and amiodarone are preferred while dronedarone and sotalol barely used. Ablation is the first-line therapy for symptomatic paroxysmal AF (69%) and persistent AF with markers of atrial disease (57%) and is performed independently of symptoms by 15%. In persistent AF, 68% performs only pulmonary vein isolation and 32% also additional lesions. CONCLUSION: There is marked heterogeneity in AF management and limited accordance to last guidelines in the EHRA community. Most of the discrepancies are related to the main controversial issues, such as those related to AF screening, management of comorbidities, pharmacological treatment, and ablation strategy.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Comorbidity , Surveys and Questionnaires , Sotalol , Anticoagulants/therapeutic use , Treatment Outcome
18.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38293821

ABSTRACT

AIMS: Simulator training has been recently introduced in electrophysiology (EP) programmes in order to improve catheter manipulation skills without complication risks. The aim of this study is to survey the current use of EP simulators and the perceived need for these tools in clinical training and practice. METHODS AND RESULTS: A 20-item online questionnaire developed by the Scientific Initiatives Committee of the European Heart Rhythm Association (EHRA) in collaboration with EHRA Digital Committee was disseminated through the EHRA Scientific Research Network members, national EP groups, and social media platforms. Seventy-four respondents from 22 countries (73% males; 50% under 40 years old) completed the survey. Despite being perceived as useful among EP professionals (81%), EP simulators are rarely a part of the institutional cardiology training programme (20%) and only 18% of the respondents have an EP simulator at their institution. When available, simulators are mainly used in EP to train transseptal puncture, ablation, and mapping, followed by device implantation (cardiac resynchronization therapy [CRT], leadless, and conduction system pacing [CSP]). Almost all respondents (96%) believe that simulator programmes should be a part of the routine institutional EP training, hopefully developed by EHRA, in order to improve the efficacy and safety of EP procedures and in particular CSP 58%, CRT 42%, leadless pacing 38%, or complex arrhythmia ablations (VT 58%, PVI 45%, and PVC 42%). CONCLUSION: This current EHRA survey identified a perceived need but a lack of institutional simulator programme access for electrophysiologists who could benefit from it in order to speed up the learning curve process and reduce complications of complex EP procedures.


Subject(s)
Cardiac Resynchronization Therapy , Physicians , Male , Humans , Adult , Female , Surveys and Questionnaires , Cardiac Resynchronization Therapy/methods , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Cardiac Electrophysiology , Cardiac Conduction System Disease/therapy , Europe
19.
Heart Rhythm ; 2024 Jan 20.
Article in English | MEDLINE | ID: mdl-38246567

ABSTRACT

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.

SELECTION OF CITATIONS
SEARCH DETAIL
...