Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
PLoS One ; 19(8): e0306074, 2024.
Article in English | MEDLINE | ID: mdl-39088429

ABSTRACT

The paper presents a validation of novel multichannel ballistocardiography (BCG) measuring system, enabling heartbeat detection from information about movements during myocardial contraction and dilatation of arteries due to blood expulsion. The proposed methology includes novel sensory system and signal processing procedure based on Wavelet transform and Hilbert transform. Because there are no existing recommendations for BCG sensor placement, the study focuses on investigation of BCG signal quality measured from eight different locations within the subject's body. The analysis of BCG signals is primarily based on heart rate (HR) calculation, for which a J-wave detection based on decision-making processes was used. Evaluation of the proposed system was made by comparing with electrocardiography (ECG) as a gold standard, when the averaged signal from all sensors reached HR detection sensitivity higher than 95% and two sensors showed a significant difference from ECG measurement.


Subject(s)
Ballistocardiography , Electrocardiography , Heart Rate , Humans , Ballistocardiography/methods , Heart Rate/physiology , Electrocardiography/methods , Male , Adult , Female , Signal Processing, Computer-Assisted , Young Adult , Wavelet Analysis
2.
Sci Rep ; 12(1): 20159, 2022 11 23.
Article in English | MEDLINE | ID: mdl-36418487

ABSTRACT

This paper introduces a novel algorithm for effective and accurate extraction of non-invasive fetal electrocardiogram (NI-fECG). In NI-fECG based monitoring, the useful signal is measured along with other signals generated by the pregnant women's body, especially maternal electrocardiogram (mECG). These signals are more distinct in magnitude and overlap in time and frequency domains, making the fECG extraction extremely challenging. The proposed extraction method combines the Grey wolf algorithm (GWO) with sequential analysis (SA). This innovative combination, forming the GWO-SA method, optimises the parameters required to create a template that matches the mECG, which leads to an accurate elimination of the said signal from the input composite signal. The extraction system was tested on two databases consisting of real signals, namely, Labour and Pregnancy. The databases used to test the algorithms are available on a server at the generalist repositories (figshare) integrated with Matonia et al. (Sci Data 7(1):1-14, 2020). The results show that the proposed method extracts the fetal ECG signal with an outstanding efficacy. The efficacy of the results was evaluated based on accurate detection of the fQRS complexes. The parameters used to evaluate are as follows: accuracy (ACC), sensitivity (SE), positive predictive value (PPV), and F1 score. Due to the stochastic nature of the GWO algorithm, ten individual runs were performed for each record in the two databases to assure stability as well as repeatability. Using these parameters, for the Labour dataset, we achieved an average ACC of 94.60%, F1 of 96.82%, SE of 97.49%, and PPV of 98.96%. For the Pregnancy database, we achieved an average ACC of 95.66%, F1 of 97.44%, SE of 98.07%, and PPV of 97.44%. The obtained results show that the fHR related parameters were determined accurately for most of the records, outperforming the other state-of-the-art approaches. The poorer quality of certain signals have caused deviation from the estimated fHR for certain records in the databases. The proposed algorithm is compared with certain well established algorithms, and has proven to be accurate in its fECG extractions.


Subject(s)
Fetal Monitoring , Signal Processing, Computer-Assisted , Female , Pregnancy , Humans , Fetal Monitoring/methods , Electrocardiography/methods , Algorithms , Databases, Factual
3.
IEEE Rev Biomed Eng ; 15: 200-221, 2022.
Article in English | MEDLINE | ID: mdl-33513108

ABSTRACT

Synchronization of human vital signs, namely the cardiac cycle and respiratory excursions, is necessary during magnetic resonance imaging of the cardiovascular system and the abdominal cavity to achieve optimal image quality with minimized artifacts. This review summarizes techniques currently available in clinical practice, as well as methods under development, outlines the benefits and disadvantages of each approach, and offers some unique solutions for consideration.


Subject(s)
Heart , Magnetic Resonance Imaging , Artifacts , Heart/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Respiratory Rate
4.
Sensors (Basel) ; 20(6)2020 Mar 19.
Article in English | MEDLINE | ID: mdl-32204440

ABSTRACT

This study focuses on the design of a measuring system for monitoring the power quality within the SMART street lighting test polygon at university campuses with relation to testing an adaptive current control strategy for three-phase shunt active power filters. Unlike conventional street lighting, SMART elements are powered 24/7. Due to the electronic character of the power part of such mass appliances, there are increased problems with the power quality of the electric energy. Compared to the current concept of street lighting, there is a significant increase in the content of higher current harmonic components, which cause several problems in the distribution system. The test polygon contains 16 luminaires made by various manufacturers and mounted with various SMART components. Using the polygon control and monitoring system, dynamic load scenarios were selected. These scenarios tested the possibilities of different adaptive current control strategies for three-phase shunt active power filters to improve the power quality of electricity. This study focuses on three adaptive algorithms that respond to dynamic changes of current harmonics level in real-time. The possibility of active filter control was tested using FPGA, mainly due to the low latency of the filter control part.

SELECTION OF CITATIONS
SEARCH DETAIL