Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38082947

ABSTRACT

Neural recordings frequently get contaminated by ECG or pulsation artifacts. These large amplitude components can mask the neural patterns of interest and make the visual inspection process difficult. The current study describes a sparse signal representation strategy that targets to denoise pulsation artifacts in local field potentials (LFPs) recorded intraoperatively. To estimate the morphology of the artifact, we first detect the QRS-peaks from the simultaneously recorded ECG trace as an anchor point. After the LFP data has been epoched with respect to each beat, a pool of raw data segments of a specific length is generated. Using the K-singular value decomposition (K-SVD) algorithm, we constructed a data-specific dictionary to represent each contaminated LFP epoch in a sparse fashion. Since LFP is aligned to each QRS complex and the background neural activity is uncorrelated to the anchor points, we assumed that constructed dictionary will be formed to mainly represent the pulsation artifact. In this scheme, we performed an orthogonal matching pursuit to represent each LFP epoch as a linear combination of the dictionary atoms. The denoised LFP data is thus obtained by calculating the residual between the raw LFP and its approximation. We discuss and demonstrate the improvements in denoised data and compare the results with respect to principal component analysis (PCA). We noted that there is a comparable change in the signal for visual inspection to observe various oscillating patterns in the alpha and beta bands. We also see a noticeable compression of signal strength in the lower frequency band (<13 Hz), which was masked by the pulsation artifact, and a strong increase in the signal-to-noise ratio (SNR) in the denoised data.Clinical Relevance- Pulsation artifact can mask relevant neural activity patterns and make their visual inspection difficult. Using sparse signal representation, we established a new approach to reconstruct the quasiperiodic pulsation template and computed the residue signal to achieve noise-free neural activity.


Subject(s)
Artifacts , Data Compression , Electroencephalography/methods , Signal Processing, Computer-Assisted , Algorithms
2.
Article in English | MEDLINE | ID: mdl-37601420

ABSTRACT

Traditional deep brain stimulation (DBS) treatment for Parkinson's disease (PD) targets the placement of DBS leads into subthalamic nucleus (STN). Extraction of neurobiomarkers from STN local field potential activity can be used for the optimization of DBS. Beta (12-30 Hz) and high frequency oscillations (200-450 Hz, HFO) of STN and their phase-amplitude coupling have been previously correlated with symptom severity in PD. The typical approach is to take bipolar derivations of electrode contacts in order to enhance recordings of local brain activity and suppress noise levels. This approach can often cancel the signals in correlated neighboring contacts and create ambiguity in which monopolar contact to select for the identification of the main source of the oscillatory signal. To improve local specificity and help identify the source of beta and HFO in terms of electrode contact, we propose a semi supervised blind-source separation method. This approach presents a novel perspective to investigate electrophysiology by projecting the recorded channels into a subspace of virtual channels. We show the contribution of each channel to the identified source and correlate the spatial information with imaging and postoperative programming parameters. We anticipate such a source identification strategy can be used in the future to investigate the distribution of beta and HFO on individual contacts of the DBS lead and can improve the interpretation of these signals.

3.
Front Comput Neurosci ; 16: 747735, 2022.
Article in English | MEDLINE | ID: mdl-35399915

ABSTRACT

Affective studies provide essential insights to address emotion recognition and tracking. In traditional open-loop structures, a lack of knowledge about the internal emotional state makes the system incapable of adjusting stimuli parameters and automatically responding to changes in the brain. To address this issue, we propose to use facial electromyogram measurements as biomarkers to infer the internal hidden brain state as feedback to close the loop. In this research, we develop a systematic way to track and control emotional valence, which codes emotions as being pleasant or obstructive. Hence, we conduct a simulation study by modeling and tracking the subject's emotional valence dynamics using state-space approaches. We employ Bayesian filtering to estimate the person-specific model parameters along with the hidden valence state, using continuous and binary features extracted from experimental electromyogram measurements. Moreover, we utilize a mixed-filter estimator to infer the secluded brain state in a real-time simulation environment. We close the loop with a fuzzy logic controller in two categories of regulation: inhibition and excitation. By designing a control action, we aim to automatically reflect any required adjustments within the simulation and reach the desired emotional state levels. Final results demonstrate that, by making use of physiological data, the proposed controller could effectively regulate the estimated valence state. Ultimately, we envision future outcomes of this research to support alternative forms of self-therapy by using wearable machine interface architectures capable of mitigating periods of pervasive emotions and maintaining daily well-being and welfare.

4.
J Appl Clin Med Phys ; 20(11): 199-205, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31609076

ABSTRACT

PURPOSE: Routine quality assurance (QA) testing to identify malfunctions in medical imaging devices is a standard practice and plays an important role in meeting quality standards. However, current daily computed tomography (CT) QA techniques have proven to be inadequate for the detection of subtle artifacts on scans. Therefore, we investigated the ability of a radiomics phantom to detect subtle artifacts not detected in conventional daily QA. METHODS: An updated credence cartridge radiomics phantom was used in this study, with a focus on two of the cartridges (rubber and cork) in the phantom. The phantom was scanned using a Siemens Definition Flash CT scanner, which was reported to produce a subtle line pattern artifact. Images were then imported into the IBEX software program, and 49 features were extracted from the two cartridges using four different preprocessing techniques. Each feature was then compared with features for the same scanner several months previously and with features from controlled CT scans obtained using 100 scanners. RESULTS: Of 196 total features for the test scanner, 79 (40%) from the rubber cartridge and 70 (36%) from the cork cartridge were three or more standard deviations away from the mean of the controlled scan population data. Feature values for the artifact-producing scanner were closer to the population mean when features were preprocessed with Butterworth smoothing. The feature most sensitive to the artifact was co-occurrence matrix maximum probability. The deviation from the mean for this feature was more than seven times greater when the scanner was malfunctioning (7.56 versus 1.01). CONCLUSIONS: Radiomics features extracted from a texture phantom were able to identify an artifact-producing scanner as an outlier among 100 CT scanners. This preliminary analysis demonstrated the potential of radiomics in CT QA to identify subtle artifacts not detected using the currently employed daily QA techniques.


Subject(s)
Image Processing, Computer-Assisted/methods , Lymphoma/diagnostic imaging , Phantoms, Imaging , Quality Assurance, Health Care/standards , Tomography Scanners, X-Ray Computed/standards , Tomography, X-Ray Computed/methods , Algorithms , Humans , Tomography, X-Ray Computed/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...