ABSTRACT

PURPOSE: Primary stability is the most important prognostic index for predicting osseointegration. It is generally thought that to achieve high primary stability, it is necessary to insert an implant with a high insertion torque (IT). To date, it has not yet been determined whether IT and implant stability quotient (ISQ) values are correlated. The primary aim of the study was to determine the correlation between IT and ISQ values at the time of implant insertion (T0); at 2 months, the time of healing (T1); and at 6 (T2) and 12 months (T3) after loading. The secondary aims were to determine the influence of different macroscopic implant designs and of a different insertion arch on this correlation; and to assess whether implants inserted with a high IT, that is, > 50 Ncm, had higher levels of implant stability at 2-, 6-, and 12-month follow-ups. MATERIALS AND METHODS: STROBE guidelines were followed. Partially or monoedentulous patients were randomly assigned to receive taper thread on straight-body implants with microthreads (group A) or without microthreads (group B). At implant insertion, IT and ISQ values were recorded. At 2-, 6-, and 12-month follow-ups, the ISQ values were recorded. A spring-style torque wrench was used to assess the IT. The Osstell device was used to determine the ISQ values. Descriptive statistics, Pearson correlation, and t test were used. P was set at ≤ .005. RESULTS: Two hundred fifty subjects were assessed; 142 were included. Two hundred sixty-eight implants were inserted (group A, 137 implants; group B, 131 implants). No subject dropped out, and no implant failed. A statistically significant correlation between ISQ and IT was determined at the time of implant insertion (T0; P = .000). The implant morphology and arch did not influence the correlation. An IT > 50 did not determine a higher secondary stability. CONCLUSION: There is a strong correlation between IT and primary stability, but IT is not correlated with the secondary stability. A different implant macroscopic design and a different arch of insertion did not influence this correlation. Moreover, implants inserted with IT > 50 Ncm do not result in greater secondary stability.


Subject(s)
Dental Implantation, Endosseous , Dental Implants , Cohort Studies , Dental Prosthesis Design , Humans , Prospective Studies , Torque
2.
J Clin Exp Dent ; 12(12): e1109-e1116, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33282130

ABSTRACT

BACKGROUND: The patient's needs should guide the orthodontist in choosing the most appropriate therapy. The purpose of the present survey was to compare the esthetic perception of the facial profile by orthodontists (O), dentistry students (DS), orthodontic patients (OP) and surgical-orthodontic patients (SOP) and to evaluate the influence of gender, age and level of study. MATERIAL AND METHODS: A facial profile photograph of a young female was taken and twelve modified images were made, altering the position of the jaws in protrusion and in retrusion. Two hundred caucasian examiners, divided into four groups (O, DS, OP, SOP), were selected. Each examiner was asked to complete the questionnaire with an approval rating from 1 to 10. An ordinary least square OLS model was applied. Significant levels were set at P ≤ 0.05. RESULTS: All examiners considered a straight profile or a slight retrusion of the maxilla as the most attractive profile. Slight discrepancies (up to 2 mm) in jaw protrusion were barely perceived by patients. Mandibular retrusion (2 and 4 mm) was one of the least appreciated condition by all examiners. Surgical-orthodontic patients assigned lower ratings compared to orthodontic patients. Female subjects assigned lower ratings than males. Patients with secondary school education assigned higher statistically significant values compared to other levels of study. The lowest values were attributed by the sample of age > = 17 years. CONCLUSIONS: The choice of the most appropriate therapy is based not only on a correct diagnosis, but on the evaluation of esthetic and psychological aspects. Key words:Estethic, profile, orthodontic, surgical orthodontic patients.

3.
Minerva Stomatol ; 69(3): 159-164, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32610724

ABSTRACT

BACKGROUND: An observational case-control study was designed to retrospectively assess the association among sex, skeletal and dental variables and the and the palatal maxillary canine impaction. METHODS: The STROBE guidelines were followed. The records of 2195 subjects were analyzed. The data records of subjects with palatally displaced canine (PDC) were compared with the data of randomly selected subjects without PDC. Descriptive statistics, logistic regression model and χ2 test were used. RESULTS: One hundred and one subjects presented at least one PDC; 106 subjects without PDC were randomly selected. From the logistic model, it was found that only gender and persistence of the deciduous canine were significantly associated with PDC. The Chi-square test showed a correlation between the presence of upper lateral incisor anomalies and PDC, otherwise, considering the unilateral impaction, there was no statistically significant difference in the relationship between canine impaction and the presence of the lateral incisor anomalies, on the same or opposite side of the impaction. CONCLUSIONS: The female sex and the persistence of maxillary deciduous canines are associated with PDC. The anomalies of the lateral incisor do not seem to play a mechanistic role, but could rather represent a genetic variable of the canine eruption disorder.


Subject(s)
Incisor , Tooth, Impacted , Case-Control Studies , Cuspid , Female , Humans , Maxilla , Retrospective Studies
4.
J Clin Exp Dent ; 11(7): e650-e658, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31516664

ABSTRACT

BACKGROUND: Maxillary molar distalization is the most frequently used nonextraction treatment in the correction of Class II malocclusion. The use of traditional intra-oral devices shows unreliable results. Nowadays the use of miniscrew-supported appliances helps prevent anchorage loss. The aim of this pilot study is to compare the amount of upper first molar distalization and the dentoalveolar side effects using traditional distal jet appliance and miniscrew-supported distal jet appliance. MATERIAL AND METHODS: 20 patients were randomly assigned to receive a treatment with miniscrew-supported distal jet appliance (Group A) or with traditional distal jet appliance (Group B). To ensure a safe and minimally invasive miniscrew insertion a surgical guide was used. Digital models and lateral cephalograms were obtained and analyzed before orthodontic treatment and at 6-month follow-up. Intergroup differences were determined using T- test. The significance was set at p ≤0.05. The intra-operator reliability was evaluated using a 2 sample T-test. The difference was not statistically significant (P ≤0.05 ), demonstrating an intra-operator reliability. RESULTS: In Group A, a greater maxillary first molar distalization was recorded (P=0.002). Considering the dentoalveolar side effects, in Group A, a spontaneous distalization of the first premolars and a retroclination of central incisors were determined. In Group B, the first premolars tipped mesially with a proclination of the maxillary central incisors. CONCLUSIONS: Miniscrew-supported distal jet appliance achieved a greater first molar distalization at 6-month follow-up and did not cause dento-alveolar side effects, such as the mesial drift of the premolars and the incisors. Key words:Molar distalization, distal jet appliance, skeletal anchorage, miniscrew, 3D printed surgical guide.

5.
Int J Oral Maxillofac Implants ; 31(5): 1031-9, 2016.
Article in English | MEDLINE | ID: mdl-27632257

ABSTRACT

PURPOSE: The aim of this prospective clinical study was to evaluate the survival up to 5 years of Morse cone-connection implants with platform switch considering the influence of biologically relevant, anatomical, and stress-related variables. STROBE guidelines were followed. MATERIALS AND METHODS: Seven hundred forty-eight implants were inserted in 350 patients. Follow-up visits were scheduled at the time of stagetwo surgery (2 months later) and at 6, 12, 24, 36, and 60 months. All implants were initially loaded with a cemented provisional acrylic restoration. The definitive metal-ceramic restorations were cemented at the 6-month follow-up. Implant cumulative survival rates (CSRs) were calculated using life table actuarial method. Survival data were also analyzed by the log-rank test and Cox regression. The statistical analysis was conducted at the patient level. P ≤ .05 was considered as an indicator of statistical significance. RESULTS: During the follow-up (mean: 40 months; SD: 20.27), 28 patients were considered failed (8%). The CSR and its standard error (SE) was 92% ± 2.17%. Patients with implant-supported single crowns had a CSR of 90%, whereas those with implant-supported fixed dental prostheses had a CSR of 93%. The implant diameter (P = .0399) and implant length (P = .0441) were statistically significant. The probability of failure was almost 75% lower for patients with wide rather than standard implants, 91% lower for patients with long implants, and 69% lower for patients with standard implants compared with short implants. CONCLUSION: The use of Morse cone-connection implants with platform switch is a safe and reliable treatment method. Stress-related variables influence the risk of failure confirming the importance of biomechanical factors in the longevity of osseointegrated implants; thus, the clinician may obtain better results if attention is paid to these factors.


Subject(s)
Dental Implantation, Endosseous/standards , Dental Implants , Dental Prosthesis Design , Dental Prosthesis Retention/standards , Dental Prosthesis, Implant-Supported/standards , Adult , Aged , Aged, 80 and over , Dental Implantation, Endosseous/methods , Dental Prosthesis, Implant-Supported/methods , Dental Restoration Failure , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Regression Analysis , Survival Analysis , Treatment Outcome , Young Adult
6.
J Oral Sci ; 58(1): 49-57, 2016.
Article in English | MEDLINE | ID: mdl-27021540

ABSTRACT

A prospective cohort study was designed to measure marginal bone level changes at 36-month follow-up and to evaluate the influence of biologically relevant, anatomic and stress-related variables. STROBE guidelines were followed. Totally, 748 implants were inserted into 350 patients. Standardized periapical radiographs were taken at 2- (stage-two surgery), 12-, 24-, and 36-month follow-ups. Descriptive statistics were used and inter- and intra-examiner reliability were determined. A mixed-model was used to evaluate predictor variables. Statistical analysis was performed at implant level (statistical significance: P < 0.05). A total of 34 (4.5%) implants failed; of the 34 implants, 6 were early failures (0.8%) and 28 were late failures (3.7%). A total of 576 implants reached 36-month follow-up (mean follow-up: 25.58 months; SD: 10.32). Mean marginal bone remodeling was -0.56 mm. (SD: 1.30; range: -6.80 ± 3.65). A statistically significant, higher marginal bone loss was found for subcrestal implants and subcrestal implants inserted into the maxilla, for implants inserted into patients aged over 50 years, and for early-delayed implants inserted into patients aged over 50 years. In conclusion, a low, mean crestal bone loss at 36-month follow-up was recorded but implant positioning in the apico-occlusal dimension was found to be the most significant variable that influenced bone loss. (J Oral Sci 58, 49-57, 2016).


Subject(s)
Alveolar Bone Loss/surgery , Dental Implants/adverse effects , Osteoporosis/physiopathology , Female , Humans , Male , Osteoporosis/prevention & control , Prospective Studies