Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Interv Neuroradiol ; : 15910199241254412, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38751100

ABSTRACT

BACKGROUND: Studies investigating endovascular therapy in vertebro-basilar stroke have led to controversial results in the past, but recent randomized trials seem to show an effectiveness superiority of endovascular therapy versus best medical treatment. However, uncertainty remains concerning many aspects of thrombectomy in acute basilar artery occlusion, notably technical considerations. This study compared the first-pass effect of direct thromboaspiration and combined thrombectomy in the setting of distal basilar occlusion. METHODS: An in-vitro experimental set-up was used, consisting of a vascular phantom model and thrombus analogs of different consistencies to mimic human clots. Thrombus analogs were injected into the model through the vertebral artery and flowed to the basilar distal third to mimic a distal basilar occlusion. Ten procedures were performed for each thrombus analog stiffness and technique (direct thromboaspiration versus combined thrombectomy). RESULTS: Direct thromboaspiration showed an overall first-pass effect rate of 83.3% (25/30) and was particularly effective for ultra-soft and soft clot analogs, but decreased for hard clot analogs. Combined thrombectomy had an overall first-pass effect rate of 56.7% (17/30). The effect rate for ultra-soft and soft clot analogs was 60% and 50% for hard clot analogs. In the softer clot analogs, the stent-retriever device used for the combined thrombectomies tended to deviate the clot analog from a co-axial trajectory with the aspiration catheter. CONCLUSIONS: In the context of distal basilar occlusion, our in-vitro results showed that higher first-pass effect rates were achieved with direct thromboaspiration compared to combined thrombectomy in all types of thrombus analogs.

2.
J Neurointerv Surg ; 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38637149

ABSTRACT

BACKGROUND: The identification of specific clot characteristics before mechanical thrombectomy (MTB) might allow the selection of the most effective first-line technique, thus potentially improving the procedural outcome. We aimed to evaluate if the microwire push forces could extrapolate information on clot consistency and extension before MTB, based on clot mechanical properties. METHODS: We measured in vitro the forces exerted on the proximal extremity of the guidewire during the advancement and retrieval of the guidewire through clot analogs of different compositions. In addition, we analyzed the forces exerted on the guidewire to extrapolate information about the location of the proximal and distal extremities of the clot analogs. RESULTS: The maximum forces recorded during the whole penetration phase were significantly different for hard and soft clots (median values, 55.6 mN vs 15.4 mN, respectively; P<0.0001). The maximum slope of the force curves recorded during the advancement of the guidewire for the first 3 s of penetration also significantly differentiated soft from hard clot analogs (7.6 mN/s vs 23.9 mN/s, respectively; P<0.0001). In addition, the qualitative analysis of the shape of the force curves obtained during the advancement and retrieval of the guidewire showed a good potential for the identification of the proximal and distal edges of the clot analogs. CONCLUSION: Our results demonstrated that it was possible to differentiate between soft and hard clot analogs. Furthermore, force measurements could give important information about the location of the clot extremities. Such an approach might support the selection of the first-line MTB technique, with the potential to improve the outcome.

3.
Article in English | MEDLINE | ID: mdl-38521091

ABSTRACT

BACKGROUND: Mechanical thrombectomy using a double stent-retriever technique has recently been described for the treatment of acute ischemic stroke, but its efficacy and safety are not well established. PURPOSE: The aim of this systematic review and meta-analysis was to evaluate reports of the use of double stent-retriever during the endovascular treatment of patients with ischemic stroke. DATA SOURCES: The PubMed, Embase, Web of Science and Scopus databases were searched to identify all studies (clinical trials, cohorts series and case reports) investigating the utility of double stent-retriever for the treatment of stroke. The study is reported in accordance with PRISMA 2020 guidelines and was prospectively registered in PROSPERO (BLINDED FOR PEER REVIEW). STUDY SELECTION: 17 studies involving a total of 128 patients with large vessel occlusions predominantly in the anterior circulation (93.0%) were identified. DATA ANALYSIS: Outcomes of interest were the prevalence of successful recanalization (mTICI ≥2b) and a first-pass effect following double stent-retriever, as well as complications such as iatrogenic dissections and subarachnoid hemorrhage. Data were pooled using a random-effects model. DATA SYNTHESIS: Double stent-retriever was used as a rescue strategy in occlusions refractory to conventional endovascular treatment in 68.7% (88/128) of patients and as a first-line strategy in 31.3% (40/128) patients. Double stent-retriever achieved an overall final mTICI ≥2b in 92.6% cases with a first-pass effect of 76.6%. The complication rate remained low, with 0.37% dissection and 1.56% subarachnoid hemorrhage. LIMITATIONS: Limitations of the study include (1) a large number of case reports or small series, (2) a meta-analysis of proportions with no statistical comparison to a control group, and (3) the lack of access to patient-level data. CONCLUSIONS: Our findings suggest that double stent-retriever thrombectomy may be safe and associated with good recanalization outcomes, but prospective comparative studies are needed to determine which patients may benefit from this endovascular procedure. ABBREVIATIONS: AICH = asymptomatic intracranial hemorrhage; AIS = acute ischemic stroke; DSR = double stent-retriever; FPE = first pass effect; ICH = intracranial hemorrhage; LVO = large vessel occlusion; MT = mechanical thrombectomy; SAH = subarachnoid hemorrhage; SICH = symptomatic intracranial hemorrhage; SSR = single stent-retriever.

4.
Interv Neuroradiol ; : 15910199231221510, 2023 Dec 17.
Article in English | MEDLINE | ID: mdl-38105436

ABSTRACT

BACKGROUND: Focal vasospasm (FV) of the occluded vessel can occur during the endovascular treatment of acute ischemic stroke (AIS). Nimodipine is commonly used to treat vasospasm and can play a role in distinguishing it from artery narrowing due to iatrogenic dissection or residual clot. However, nimodipine administration can result in arterial hypotension and subsequent enlargement of the ischemic core. OBJECTIVE: To assess the efficacy of preventive and continuous vasoactive amine infusion to counterbalance nimodipine-induced hypotension. METHODS: We reviewed data from a prospective registry of patients treated for AIS between January 2019 and January 2022 who were administered nimodipine. All patients were equipped with an arterial cannula for invasive blood pressure measurement and given vasoactive amines preemptively before general anesthesia and throughout the procedure. Data obtained from invasive monitoring of mean arterial blood pressure (MABP) in a time-lapse of 25 min before and after nimodipine administration were analyzed. RESULTS: MABP significantly decreased after nimodipine administration but remained within the recommended range (81.79 ± 0.49 mmHg). Nimodipine was effective in reducing FV caused by stent retriever passage in 76.3% of cases. Furthermore, it proved valuable in diagnosing iatrogenic dissection (9.2%), residual clot (10.5%), or intracranial stenosis (4%). CONCLUSIONS: Infusion of vasoactive amines effectively counteracted the intraarterial nimodipine effect, thus avoiding frank arterial hypotension during endovascular treatment. Nimodipine has been useful in differentiating the diagnosis of FV resulting from mechanical thrombectomy and other potential causes, such as iatrogenic dissection or residual clot.

5.
Interv Neuroradiol ; : 15910199231179846, 2023 Jul 06.
Article in English | MEDLINE | ID: mdl-37415424

ABSTRACT

BACKGROUND AND PURPOSE: A mechanical thrombectomy technique using a double stent retriever approach has been reported for the treatment of patients with acute ischemic stroke. The purpose of this study was to perform a benchtop evaluation of the mechanism of action and efficacy of a double-stent retriever approach compared to a single-stent retriever approach. MATERIALS AND METHODS: In vitro, mechanical thrombectomy procedures were performed in a vascular phantom reproducing an M1-M2 occlusion with two different clot analog consistencies (soft and hard). We compared the double stent retriever approach to the single stent retriever approach and recorded the recanalization rate, distal embolization, and retrieval forces of each mechanical thrombectomy procedure. RESULTS: The double stent retriever approach achieved a higher recanalization rate and lower embolic complications compared to the single stent retriever approach. This seems to stem from two facts: the greater probability of targeting the correct artery with two stents in the case of bifurcation occlusion, and an improved clot capture mechanism using the double stent retriever approach. However, the double stent retriever was associated with an increased initial retrieval force. CONCLUSIONS: In vitro evaluation of the mechanism of action of the double stent retriever provided explanations that appear to support the high efficacy of such an approach in patient cohorts and could help operators when selecting the optimal mechanical thrombectomy strategy in cases of arterial occlusions difficult to treat with a single stent retriever.

6.
Interv Neuroradiol ; : 15910199231171806, 2023 May 02.
Article in English | MEDLINE | ID: mdl-37131328

ABSTRACT

BACKGROUND: Bilateral and simultaneous occlusion of the anterior circulation is a rare event in patients with acute ischemic stroke. Although endovascular treatment is feasible and safe, the endovascular strategy to be used remains a subject of debate. OBJECTIVE: To assess the different endovascular strategies proposed for the treatment of a bilateral, simultaneous anterior circulation occlusion following acute ischemic stroke. METHODS: We present a retrospective study of the clinical and radiological records of all patients with a bilateral, simultaneous anterior circulation occlusion treated at our center between January 2019 and December 2022. Following the PRISMA guidelines, we also conducted a systematic review of the literature. RESULTS: Two patients with a bilateral and simultaneous middle cerebral artery occlusion were treated at our center during the study period. A TICI score ≥2b was obtained in 4 out of 4 occlusions. Modified Rankin Scale (mRS) at 90 days was 0 and 4, respectively. The literature review retrieved reports on 22 patients. The most frequent bilateral occlusion sites were internal carotid artery-middle cerebral artery. The clinical presentation was severe in most patients. A combined thrombectomy technique proved to have the highest number of first-pass recanalization. A TICI ≥2b was obtained in 95% of patients and an mRS ≤2 was found in 31.8% of patients. CONCLUSIONS: In patients with bilateral and simultaneous occlusion of the anterior circulation, endovascular treatment using a combined technique appears to be rapid and effective. The clinical evolution of this patient population strongly depends on the severity of the onset symptoms.

7.
MAGMA ; 36(2): 295-308, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37072539

ABSTRACT

OBJECTIVE: Wall shear stress (WSS) and its derived spatiotemporal parameters have proven to play a major role on intracranial aneurysms (IAs) growth and rupture. This study aims to demonstrate how ultra-high field (UHF) 7 T phase contrast magnetic resonance imaging (PC-MRI) coupled with advanced image acceleration techniques allows a highly resolved visualization of near-wall hemodynamic parameters patterns in in vitro IAs, paving the way for more robust risk assessment of their growth and rupture. MATERIALS AND METHODS: We performed pulsatile flow measurements inside three in vitro models of patient-specific IAs using 7 T PC-MRI. To this end, we built an MRI-compatible test bench, which faithfully reproduced a typical physiological intracranial flow rate in the models. RESULTS: The ultra-high field 7 T images revealed WSS patterns with high spatiotemporal resolution. Interestingly, the high oscillatory shear index values were found in the core of low WSS vortical structures and in flow stream intersecting regions. In contrast, maxima of WSS occurred around the impinging jet sites. CONCLUSIONS: We showed that the elevated signal-to-noise ratio arising from 7 T PC-MRI enabled to resolve high and low WSS patterns with a high degree of detail.


Subject(s)
Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Blood Flow Velocity , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging , Hemodynamics , Stress, Mechanical
8.
J Neuroradiol ; 50(3): 352-360, 2023 May.
Article in English | MEDLINE | ID: mdl-36649796

ABSTRACT

Following the advent of mechanical thrombectomy, occlusive clots in ischemic stroke have been amply characterized using conventional histopathology. Many studies have investigated the compositional variability of thrombi and the consequences of thrombus composition on treatment response. More recent evidence has emerged about the spatial heterogeneity of the clot or the preferential distribution of its components and compact nature. Here we review this emerging body of evidence, discuss its potential clinical implications, and propose the development of adequate characterization techniques.


Subject(s)
Brain Ischemia , Ischemic Stroke , Stroke , Thromboembolism , Thrombosis , Humans , Ischemic Stroke/diagnostic imaging , Stroke/therapy , Thrombectomy/methods , Brain Ischemia/complications , Brain Ischemia/diagnostic imaging , Brain Ischemia/pathology , Thrombosis/complications , Thrombosis/diagnostic imaging , Thrombosis/pathology
9.
J Neuroradiol ; 50(1): 74-78, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35192867

ABSTRACT

BACKGROUND AND PURPOSE: Mechanical thrombectomy using an aspiration catheter (AC) is widely performed in patients with acute ischemic stroke due to large vessel occlusion. AC diameter directly impacts aspiration performance, which has led device companies to develop large bore ACs. The purpose of this study was to evaluate the in vitro performance of several commercially available large bore ACs. MATERIALS AND METHODS: We conceived an experimental set up to assess tracking force, aspiration flow rate, and distal end tensile force pre- and post-thrombectomy of ACs including Sofia 6 (Microvention Inc., California, USA), React 71 (Medtronic Neurovascular, Irvine, California, USA), Jet 7 (Penumbra Inc, Alameda, California, USA), Catalyst 7 (Stryker Neurovascular, Kalamazoo, Michigan, USA) and Embovac 071 (Johnson & Johnson Medical Ltd, UK). RESULTS: React 71 and Sofia 6 had significantly lower trackability force compared to the other ACs tested. Distal AC segment tensile force was highest for React 71 and lowest for Jet 7. Jet 7 had the highest internal diameter and the highest aspiration flow rate. CONCLUSION: The data from this comparative analysis may assist clinicians in selecting the appropriate AC and highlights the need for key performance criteria during the development of next-generation large-bore ACs for optimal AC performance.


Subject(s)
Ischemic Stroke , Stroke , Humans , Thrombectomy , Catheters , Treatment Outcome , Retrospective Studies
10.
Interv Neuroradiol ; : 15910199221145745, 2022 Dec 18.
Article in English | MEDLINE | ID: mdl-36529940

ABSTRACT

BACKGROUND: Occlusions of the middle cerebral artery (MCA) M2 segments can be difficult to address with mechanical thrombectomy (MTB) using standard projections and this can affect the final recanalization. Three-dimensional rotational angiography (3D-RA) allows to obtain a 3D model of cerebral vessels in a few seconds and to determine the best two-dimensional (2D) projections to be selected to evaluate and treat cerebrovascular diseases, such as aneurysms or vascular malformations. We aimed to determine if 3D-RA could be applied also in MTB. METHODS: A retrospective review of two patient cohorts treated during two time periods of 12 months before and after the introduction of 3D-RA use at our institution for MTB in M2 occlusions. Analyses were conducted to compare the two groups for procedural characteristics, such as timing, recanalization rate and complications and clinical outcome. RESULTS: One hundred acute ischaemic stroke (AIS) patients (3D-RA group = 57; controls = 43) underwent MTB for an M2 occlusion during the two study periods. Recanalization rates were significantly higher in cases treated with 3D-RA. The mean 3D technique thrombectomy time was compared to that of non-3D cases (47 vs. 49 min, respectively). CONCLUSIONS: Our findings showed that 3D-RA is a useful tool to select specific working projections to AIS patients presenting an M2 occlusion by improving final recanalization compared to standard projections, without increasing the overall procedural time.

11.
Interv Neuroradiol ; : 15910199221135040, 2022 Nov 08.
Article in English | MEDLINE | ID: mdl-36348632

ABSTRACT

BACKGROUND: Several variations of the combined thrombectomy technique for acute ischemic stroke using a stent retriever and aspiration catheter have been described. The aim of our study was to assess how the presence of the microcatheter and stent retriever affect the basic aspiration parameters, namely, flow rate and aspiration force, depending on their position within the aspiration catheter. METHODS: Two experimental set-ups were designed to assess changes in flow rate and aspiration force according to the position of the stent retriever and microcatheter within the aspiration catheter. RESULTS: The transition of the stent retriever and microcatheter from the distal to proximal position resulted in a progressive increase in the flow rate, but with no impact on aspiration force. Additionally, the size of the stent retriever had no significant effect on flow rate changes and the reduction in flow rate was related to the microcatheter diameter. Negative pressure generated inside the aspiration catheter impacted on its distal segment located beyond the radiopaque marker, thus leading to its partial collapse. As a consequence, the measured aspiration force was lower than the theoretical aspiration force level for all tested aspiration catheters. CONCLUSIONS: In our experimental model, the position of the stent retriever and microcatheter within the aspirator catheter affected the flow rate, but not the aspiration force. Negative pressure generated within the aspiration catheter appeared to determine a partial collapse of the distal segment that resulted in a less effective aspiration force than the theoretical aspiration force level.

12.
Front Neurol ; 13: 824091, 2022.
Article in English | MEDLINE | ID: mdl-35321513

ABSTRACT

Background: Characterization of the clot occluding the arteries in acute ischemic stroke received ample attention, in terms of elucidating the relationship between the clot composition, its etiology and its amenability for pharmacological treatment and mechanical thrombectomy approaches. Traditional analytical techniques such as conventional 2D histopathology or electron microscopy sample only small parts of the clot. Visualization and analysis in 3D are necessary to depict and comprehend the overall organization of the clot. The aim of this study is to investigate the potential of microCT for characterizing the clot composition, structure, and organization. Methods: In a pilot study, we analyzed with microCT clots retrieved from 14 patients with acute ischemic stroke. The following parameters were analyzed: overall clot density, clot segmentation with various density thresholds, clot volume. Results: Our findings show that human clots are heterogeneous in terms of CT intra-clot density distribution. After fixation in formalin, the clots display a shift toward negative values. On average, we found the mean HU values of red clots retrieved from patients to be -153 HU, with SD = 23.8 HU, for the intermediate clots retrieved from patients -193 HU, SD = 23.7 HU, and for the white clots retrieved from patients -229 HU, SD = 64.8 HU. Conclusion: Our study shows that volumetric and density analysis of the clot opens new perspectives for clot characterization and for a better understanding of thrombus structure and composition.

13.
J Stroke Cerebrovasc Dis ; 30(8): 105891, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34090173

ABSTRACT

BACKGROUND: Intracranial artery dissection is an uncommon cause of acute ischemic stroke. Although acute stenting of the dissected arterial segment is a therapeutic option, the associated antiplatelet regimen remains a matter of debate. OBJECTIVES: To evaluate the efficacy and safety of acute intracranial stenting together with concomitant intravenous administration of tirofiban and to perform a systematic review of the literature. MATERIALS AND METHODS: A single-center, retrospective study of the clinical and radiological records of all patients treated at our center by intracranial stenting in the setting of acute ischemic stroke between January 2010 and December 2020. A systematic review of the literature was conducted according to the PRISMA-P guidelines for relevant publications from January 1976 to December 2020 on intracranial artery dissection treated by stent. RESULTS: Seven patients with intracranial artery dissections underwent acute stenting with concomitant tirofiban during the study period. Mid-term follow-up showed parent artery patency in 6/7 cases (85.7%). The modified Rankin Score was ≤ 0-2 at 3 months in 5/7 cases (71.4%). The literature review identified 22 patients with intracranial artery dissection treated with acute stenting in association with different antithrombotic therapies. Complete revascularization was obtained in 86.3% of cases with a modified Rankin Score of ≤ 0-2 in 68% of patients at 3-month follow-up. CONCLUSIONS: Acute intracranial stenting together with intravenous tirofiban administration could be a therapeutic option in patients with intracranial artery dissection and a small ischemic core.


Subject(s)
Aortic Dissection/therapy , Endovascular Procedures/instrumentation , Intracranial Aneurysm/therapy , Ischemic Stroke/therapy , Platelet Aggregation Inhibitors/administration & dosage , Stents , Tirofiban/administration & dosage , Administration, Intravenous , Adult , Aged , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Endovascular Procedures/adverse effects , Female , Humans , Intracranial Aneurysm/complications , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/physiopathology , Ischemic Stroke/diagnostic imaging , Ischemic Stroke/etiology , Ischemic Stroke/physiopathology , Male , Middle Aged , Platelet Aggregation Inhibitors/adverse effects , Retrospective Studies , Time Factors , Tirofiban/adverse effects , Treatment Outcome , Vascular Patency , Young Adult
14.
J Neurointerv Surg ; 13(12): 1152-1156, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33483456

ABSTRACT

BACKGROUND: Successful direct thromboaspiration (DTA) is related to several factors such as clot consistency, size, and location. It has also been demonstrated recently that the angle of interaction (AOI) formed by the aspiration catheter and the clot is related to DTA efficacy. The aims of this study were three-fold: (a) to confirm the clinical finding that the AOI formed by the aspiration catheter and the clot influence DTA efficacy; (b) to evaluate to what extent this influence varies according to differences in clot consistency and size; and (c) to validate stent retriever thrombectomy as an effective rescue treatment after DTA failure in the presence of an unfavorable AOI. METHODS: A rigid vascular phantom designed to reproduce a middle cerebral artery trifurcation anatomy with three M2 segments forming different angles with M1 and thrombus analog of different consistencies and sizes was used. RESULTS: DTA was highly effective for AOIs >125.5°, irrespective of thrombus analog features. However, its efficacy decreased for acute AOIs. Rescue stent retriever thrombectomy was effective in 92.6% of cases of DTA failure. CONCLUSIONS: This in vitro study confirmed that the AOI formed by the aspiration catheter and the thrombus analog influenced DTA efficacy, with an AOI >125.5° related to an effective DTA. Stent retriever thrombectomy was an effective rescue treatment after DTA failure, even in the presence of an unfavorable AOI.


Subject(s)
Stroke , Thrombosis , Catheters , Humans , Stents , Thrombectomy , Thrombosis/diagnostic imaging , Treatment Outcome
15.
Acta Neurochir (Wien) ; 163(4): 885-893, 2021 04.
Article in English | MEDLINE | ID: mdl-33515124

ABSTRACT

BACKGROUND: At this juncture, there is no consensus in the literature for the use and the safety of pin-type head holders in cranial procedures. METHODS: The present analysis of the bone response to the fixation of the instrument provides data to understand its impact on the entire skull as well as associated complications. An experimental study was conducted on fresh-frozen human specimens to analyze the puncture hole due to the fixation of each single pin of the pin-type head holder. Cone-beam CT images were acquired to measure the diameter of the puncture hole caused by the instrument according to several parameters: the pin angle, the clamping force, and different neurosurgical approaches most clinically used. RESULTS: The deepest hole, 2.67 ± 0.27 mm, was recorded for a 35° angle and a clamping force of 270 N at the middle fossa approach. The shallowest hole was 0.62 ± 0.22 mm for the 43° angle with a pinning force of 180 N in the pterional approach. The pterional approach had a significantly different effect on the depth of the puncture hole compared with the middle fossa craniotomy for 270 N pinning at 35° angle. The puncture hole measured with the 43° angle and 180 N force in prone position is significantly different from the other approaches with the same force. CONCLUSIONS: These results could lead to recommendations about the use of the head holder depending on the patient's history and cranial thickness to reduce complications associated with the pin-type head holder during clinical applications.


Subject(s)
Craniotomy/methods , Patient Positioning/methods , Skull/surgery , Head Movements , Humans , Male , Prone Position
16.
J Neurointerv Surg ; 13(5): 459-464, 2021 May.
Article in English | MEDLINE | ID: mdl-32732256

ABSTRACT

BACKGROUND: Computational fluid dynamics (CFD) has become a popular tool for studying 'patient-specific' blood flow dynamics in cerebral aneurysms; however, rarely are the inflow boundary conditions patient-specific. We aimed to test the impact of widespread reliance on generalized inflow rates. METHODS: Internal carotid artery (ICA) flow rates were measured via 2D cine phase-contrast MRI for 24 patients scheduled for endovascular therapy of an ICA aneurysm. CFD models were constructed from 3D rotational angiography, and pulsatile inflow rates imposed as measured by MRI or estimated using an average older-adult ICA flow waveform shape scaled by a cycle-average flow rate (Qavg) derived from the patient's ICA cross-sectional area via an assumed inlet velocity. RESULTS: There was good overall qualitative agreement in the magnitudes and spatial distributions of time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and spectral power index (SPI) using generalized versus patient-specific inflows. Sac-averaged quantities showed moderate to good correlations: R2=0.54 (TAWSS), 0.80 (OSI), and 0.68 (SPI). Using patient-specific Qavg to scale the generalized waveform shape resulted in near-perfect agreement for TAWSS, and reduced bias, but not scatter, for SPI. Patient-specific waveform had an impact only on OSI correlations, which improved to R2=0.93. CONCLUSIONS: Aneurysm CFD demonstrates the ability to stratify cases by nominal hemodynamic 'risk' factors when employing an age- and vascular-territory-specific recipe for generalized inflow rates. Qavg has a greater influence than waveform shape, suggesting some improvement could be achieved by including measurement of patient-specific Qavg into aneurysm imaging protocols.


Subject(s)
Blood Flow Velocity/physiology , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/physiopathology , Hydrodynamics , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/physiopathology , Cerebral Angiography/methods , Cohort Studies , Female , Hemodynamics/physiology , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Male , Middle Aged , Models, Cardiovascular , Stress, Mechanical
17.
J Neurointerv Surg ; 12(4): 396-400, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31548213

ABSTRACT

BACKGROUND: Direct thromboaspiration has been reported as an effective mechanical treatment for acute ischemic stroke. We aimed to determine whether the angle of interaction between the aspiration catheter and the clot affects the success of clot removal in ischemic stroke patients with large vessel occlusion in the anterior and posterior circulation. METHODS: All patients treated at our institution by direct thromboaspiration as a firstline technique between January 2016 and December 2017 were enrolled in the study. We retrospectively reviewed baseline and procedural characteristics, the angle of interaction formed between the aspiration catheter and the clot, the modified Thrombolysis in Cerebral Infarction score, and the 3 month modified Rankin Scale score. RESULTS: 85 patients underwent direct thromboaspiration as the firstline treatment during the study period. 100 direct thromboaspiration passes were performed. An angle of interaction of ≥125.5° significantly influenced the success of clot removal (P<0.001) with good sensitivity and specificity, in particular for occlusion of the middle cerebral and basilar artery. The combination of aspiration with a stent retriever based thrombectomy was a valid rescue treatment in cases of standalone direct thromboaspiration failure. CONCLUSIONS: In our series, an angle of interaction between the aspiration catheter and the clot of ≥125.5° was significantly associated with successful clot removal. The prediction of the angle of interaction on pretreatment imaging may help operators to select the most adequate mechanical thrombectomy technique on a case by case basis.


Subject(s)
Brain Ischemia/surgery , Catheters , Cerebrovascular Disorders/surgery , Stroke/surgery , Thrombectomy/methods , Aged , Aged, 80 and over , Brain Ischemia/diagnostic imaging , Cerebrovascular Disorders/diagnostic imaging , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Female , Humans , Male , Middle Aged , Retrospective Studies , Stents , Stroke/diagnostic imaging , Thrombectomy/instrumentation , Thrombosis/diagnostic imaging , Thrombosis/surgery , Treatment Outcome
18.
J Neurointerv Surg ; 12(6): 626-630, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31772042

ABSTRACT

BACKGROUND AND PURPOSE: Computational fluid dynamics (CFD) can provide valuable information regarding intracranial hemodynamics. Patient-specific models can be segmented from various imaging modalities, which may influence the geometric output and thus hemodynamic results. This study aims to compare CFD results from aneurysm models segmented from three-dimensional rotational angiography (3D-RA) versus novel four-dimensional CT angiography (4D-CTA). METHODS: Fourteen patients with 16 cerebral aneurysms underwent novel 4D-CTA followed by 3D-RA. Endoluminal geometries were segmented from each modality using an identical workflow, blinded to the other modality, to produce 28 'original' models. Each was then minimally edited a second time to match length of branches, producing 28 additional 'matched' models. CFD simulations were performed using estimated flow rates for 'original' models (representing real-world experience) and patient-specific flow rates from 4D-CTA for 'matched' models (to control for influence of modality alone). RESULTS: Overall, geometric and hemodynamic results were consistent between models segmented from 3D-RA and 4D-CTA, with correlations improving after matching to control for operator-introduced variability. Despite smaller 4D-CTA parent artery diameters (3.49±0.97 mm vs 3.78±0.92 mm for 3D-RA; p=0.005) and sac volumes (157 (37-750 mm3) vs 173 (53-770 mm3) for 3D-RA; p=0.0002), sac averages of time-averaged wall shear stress (TAWSS), oscillatory shear (OSI), and high frequency fluctuations (measured by spectral power index, SPI) were well correlated between 3D-RA and 4D-CTA 'matched' control models (TAWSS, R2=0.91; OSI, R2=0.79; SPI, R2=0.90). CONCLUSIONS: Our study shows that CFD performed using 4D-CTA models produces reliable geometric and hemodynamic information in the intracranial circulation. 4D-CTA may be considered as a follow-up imaging tool for hemodynamic assessment of cerebral aneurysms.


Subject(s)
Cerebral Angiography/methods , Computed Tomography Angiography/methods , Four-Dimensional Computed Tomography/methods , Hydrodynamics , Imaging, Three-Dimensional/methods , Intracranial Aneurysm/diagnostic imaging , Cerebral Angiography/standards , Computed Tomography Angiography/standards , Endovascular Procedures/methods , Female , Four-Dimensional Computed Tomography/standards , Humans , Imaging, Three-Dimensional/standards , Intracranial Aneurysm/surgery , Male , Middle Aged
19.
Med Phys ; 46(5): 2126-2136, 2019 May.
Article in English | MEDLINE | ID: mdl-30793326

ABSTRACT

PURPOSE: Blood velocity and flow rate information may be helpful for a wide variety of applications, but it often requires separate acquisitions. The dynamic information combined with the high spatial resolution of four-dimensional computed tomography angiography (4D-CTA) offers the possibility to quantify blood flow simultaneous to vascular anatomy. METHODS: A 4D-CTA clinical protocol with a novel dedicated postprocessing were validated in vitro in a patient-specific model, and tested in a pilot study of six patients. Blood flow was assessed in both internal carotid (ICAs) and vertebral (VAs) arteries by analyzing spatial displacement of contrast agent in the form of time-intensity curves (TICs). Unlike previous approaches, it does not require any a priori assumptions about TIC shape, but rather computes mean velocity and flow rates from the spatial displacement of the TICs along the automatically segmented vessels. RESULTS: In vitro experiments showed good agreement between 4D-CTA and flowmeter measurements under steady and pulsatile flow conditions. In vivo measurements exhibited large interpatient variability of the TIC shapes, from which blood flow rates could nevertheless be successfully measured in all patients and investigated vessels. On average, measured flow rates were 3.2 ± 0.7 ml/s (in ICAs) and 1.3 ± 0.8 ml/s (in VAs) consistent with previous reference standards. Contrary to our novel approach, which considered the full TIC shape, application of previous time-to-peak analyses based on idealized TIC shapes showed limited reliability. CONCLUSIONS: We demonstrate the high potential of 4D-CTA for assessing blood velocity and flow rate in addition to anatomical evaluation. The wide variety of TIC shapes encountered in vivo highlights the importance of an adaptive TIC analysis as proposed in the present work.


Subject(s)
Carotid Arteries/diagnostic imaging , Cerebrovascular Circulation , Computed Tomography Angiography/methods , Four-Dimensional Computed Tomography/methods , Intracranial Aneurysm/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Vertebral Artery/diagnostic imaging , Adult , Aged , Blood Flow Velocity , Female , Humans , Male , Middle Aged , Models, Cardiovascular , Prospective Studies
20.
J Neuroradiol ; 46(3): 163-167, 2019 May.
Article in English | MEDLINE | ID: mdl-29625154

ABSTRACT

BACKGROUND AND PURPOSE: Stent retrievers are recognized as the most effective devices for intracranial thrombectomy. Although highly effective, such devices fail in clot removal when the brain vessel occlusion is due to organized, firm clots. The mechanism of failure is that during the retrieval, devices remain compressed by the organized clot and slide between it and the vessel wall without any removal effect. The aim of the current study is to present the preclinical evaluation of the Neva™ device, a novel stent retriever designed to improve the incorporation and removal of organized thrombi. MATERIALS AND METHODS: Preclinical evaluation of the Neva™ device was divided in three main chapters: efficacy analysis, mechanical analysis and safety analysis. Efficacy and mechanical analysis aimed to investigate the behavior during the retrieval of the Neva™ device and its interaction with experimental organized clots. Safety analysis was conducted on animals in order to investigate the effect of the Neva™ device on real arteries after simulated thrombectomy maneuvers. RESULTS: Neva™ device showed a high rate of "optimal clot integration" and "effective clot removal" which was related to constant cohesion to the vessel wall during retrievals. Safety analysis showed as the most frequent finding the disruption of the intima of the tested vessels with, in some cases, minimal disruption of the internal elastic lamina. CONCLUSIONS: The Neva™ device has demonstrated safety and efficacy in a pre-clinical study. Such encouraging, preliminary results have to be compared with those of clinical trials.


Subject(s)
Device Removal/methods , Stents , Thrombectomy/instrumentation , Angiography , Animals , Equipment Design , Equipment Safety , Fluoroscopy , Humans , Materials Testing , Models, Anatomic , Prosthesis Design , Prosthesis Failure , Stress, Mechanical , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...