Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 20(Pt 2): 347-54, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23412493

ABSTRACT

The performance of a single-photon-counting hybrid pixel detector has been investigated at the Australian Synchrotron. Results are compared with the body of accepted analytical models previously validated with other detectors. Detector functionals are valuable for empirical calibration. It is shown that the matching of the detector dead-time with the temporal synchrotron source structure leads to substantial improvements in count rate and linearity of response. Standard implementations are linear up to ∼0.36 MHz pixel(-1); the optimized linearity in this configuration has an extended range up to ∼0.71 MHz pixel(-1); these are further correctable with a transfer function to ∼1.77 MHz pixel(-1). This new approach has wide application both in high-accuracy fundamental experiments and in standard crystallographic X-ray fluorescence and other X-ray measurements. The explicit use of data variance (rather than N(1/2) noise) and direct measures of goodness-of-fit (χ(r)(2)) are introduced, raising issues not encountered in previous literature for any detector, and suggesting that these inadequacies of models may apply to most detector types. Specifically, parametrization of models with non-physical values can lead to remarkable agreement for a range of count-rate, pulse-frequency and temporal structure. However, especially when the dead-time is near resonant with the temporal structure, limitations of these classical models become apparent. Further, a lack of agreement at extreme count rates was evident.

2.
J Synchrotron Radiat ; 16(Pt 4): 489-93, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19535862

ABSTRACT

A synchrotron beam has been used to investigate the radiation tolerance of a PILATUS II module. It has been demonstrated that radiation-induced threshold shifts become significant above 30 Mrad. Individual adjustment of pixel thresholds after irradiation enabled retention of standard behaviour in excess of 40 Mrad. This implies that a module can be continuously irradiated for in excess of 40 days at an individual pixel count rate of 10(6) counts s(-1).

3.
J Synchrotron Radiat ; 16(Pt 3): 368-75, 2009 May.
Article in English | MEDLINE | ID: mdl-19395800

ABSTRACT

PILATUS is a silicon hybrid pixel detector system, operating in single-photon-counting mode, that has been developed at the Paul Scherrer Institut for the needs of macromolecular crystallography at the Swiss Light Source (SLS). A calibrated PILATUS module has been characterized with monochromatic synchrotron radiation. The influence of charge sharing on the count rate and the overall energy resolution of the detector were investigated. The dead-time of the system was determined using the attenuated direct synchrotron beam. A single module detector was also tested in surface diffraction experiments at the SLS, whereby its performance regarding fluorescence suppression and saturation tolerance were evaluated, and have shown to greatly improve the sensitivity, reliability and speed of surface diffraction data acquisition.


Subject(s)
Photometry/instrumentation , Radiometry/instrumentation , Transducers , X-Ray Diffraction/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Photometry/methods , Photons , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity
4.
Rev Sci Instrum ; 79(10): 10E302, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044464

ABSTRACT

The use of high resolution x-ray crystal spectrometers to diagnose fusion plasmas has been limited by the poor spatial localization associated with chord integrated measurements. Taking advantage of a new x-ray imaging spectrometer concept [M. Bitter et al., Rev. Sci. Instrum. 75, 3660 (2004)], and improvements in x-ray detector technology [Ch. Broennimann et al., J. Synchrotron Radiat. 13, 120 (2006)], a spatially resolving high resolution x-ray spectrometer has been built and installed on the Alcator C-Mod tokamak. This instrument utilizes a spherically bent quartz crystal and a set of two dimensional x-ray detectors arranged in the Johann configuration [H. H. Johann, Z. Phys. 69, 185 (1931)] to image the entire plasma cross section with a spatial resolution of about 1 cm. The spectrometer was designed to measure line emission from H-like and He-like argon in the wavelength range 3.7 and 4.0 A with a resolving power of approximately 10,000 at frame rates up to 200 Hz. Using spectral tomographic techniques [I. Condrea, Phys. Plasmas 11, 2427 (2004)] the line integrated spectra can be inverted to infer profiles of impurity emissivity, velocity, and temperature. From these quantities it is then possible to calculate impurity density and electron temperature profiles. An overview of the instrument, analysis techniques, and example profiles are presented.

5.
Rev Sci Instrum ; 79(10): 10E320, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044482

ABSTRACT

A new spatially resolving x-ray crystal spectrometer capable of measuring continuous spatial profiles of high resolution spectra (lambda/d lambda>6000) of He-like and H-like Ar K alpha lines with good spatial (approximately 1 cm) and temporal (approximately 10 ms) resolutions has been installed on the Alcator C-Mod tokamak. Two spherically bent crystals image the spectra onto four two-dimensional Pilatus II pixel detectors. Tomographic inversion enables inference of local line emissivity, ion temperature (T(i)), and toroidal plasma rotation velocity (upsilon(phi)) from the line Doppler widths and shifts. The data analysis techniques, T(i) and upsilon(phi) profiles, analysis of fusion-neutron background, and predictions of performance on other tokamaks, including ITER, will be presented.

6.
J Synchrotron Radiat ; 13(Pt 3): 271-4, 2006 May.
Article in English | MEDLINE | ID: mdl-16645253

ABSTRACT

A synchrotron X-ray diffractometer incorporating a pulsed field magnet for high fields up to 40 T has been developed and a detailed description of this instrument is reported. The pulsed field magnet is composed of two coaxial coils with a gap of 3 mm at the mid-plane for passage of the X-rays. The pixel detector PILATUS 100K is used to store the diffracted X-rays. As a test of this instrument, X-ray diffraction by a powder sample of the antiferromagnet CoO is measured below the Néel temperature. A field-dependent lattice distortion of CoO due to magnetostriction is observed up to 38 T.

7.
J Synchrotron Radiat ; 13(Pt 2): 120-30, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16495612

ABSTRACT

The PILATUS 1M detector is a hybrid pixel array detector with over one million pixels that operate in single photon counting mode. The detector, designed for macromolecular crystallography, is the largest pixel array detector currently in use at a synchrotron. It is a modular system consisting of 18 multichip modules covering an area of 21 cm x 24 cm. The design of the components as well as the manufacturing of the detector including the bump-bonding was performed at the Paul Scherrer Institute (PSI). The use of a single photon counting detector for protein crystallography requires detailed studies of the charge collection properties of the silicon sensor. The 18 modules are read out in parallel, leading to a full frame readout-time of 6.7 ms. This allows crystallographic data to be acquired in fine-varphi-slicing mode with continuous rotation of the sample. The detector was tested in several experiments at the protein crystallography beamline X06SA at the Swiss Light Source at PSI. Data were collected both in conventional oscillation mode using the shutter, as well as in a fine-varphi-slicing mode. After applying all the necessary corrections to data from a thaumatin crystal, the processing of the conventional data led to satisfactory merging R-factors of the order of 8.5%. This allows, for the first time, determination of a refined electron density map of a macromolecular biological crystal using a silicon pixel detector.


Subject(s)
Crystallography, X-Ray/instrumentation , Equipment Design , Proteins/chemistry , Silicon , Synchrotrons/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL