Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
J Clin Med ; 12(12)2023 Jun 13.
Article in English | MEDLINE | ID: mdl-37373721

ABSTRACT

BACKGROUND: Implantation of a permanent pacemaker and atrioventricular (AV) node ablation (pace-and-ablate) is an established approach for rate and symptom control in elderly patients with symptomatic atrial fibrillation (AF). Left bundle branch area pacing (LBBAP) is a physiological pacing strategy that might overcome right ventricular pacing-induced dyssynchrony. In this study, the feasibility and safety of performing LBBAP and AV node ablation in a single procedure in the elderly was investigated. METHODS: Consecutive patients with symptomatic AF referred for pace-and-ablate underwent the treatment in a single procedure. Data on procedure-related complications and lead stability were collected at regular follow-up at one day, ten days and six weeks after the procedure and continued every six months thereafter. RESULTS: 25 patients (mean age 79.2 ± 4.2 years) were included and underwent successful LBBAP. In 22 (88%) patients, AV node ablation and LBBAP were performed in the same procedure. AV node ablation was postponed in two patients due to lead-stability concerns and in one patient on their own request. No complications related to the single-procedure approach were observed with no lead-stability issues at follow-up. CONCLUSIONS: LBBAP combined with AV node ablation in a single procedure is feasible and safe in elderly patients with symptomatic AF.

2.
Europace ; 13(1): 87-95, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20880954

ABSTRACT

AIMS: We investigated the accuracy and feasibility of a non-invasive arterial pulse contour technique for continuous measurement of stroke volume (SV) in optimization of atrioventricular (AV) delay in cardiac resynchronization therapy (CRT), by comparing SV changes assessed by Nexfin CO-Trek® (Nexfin) and echo Doppler aortic velocity-time integral (VTIao). Furthermore, we investigated whether AV-delay optimization increases the effect of CRT when compared with a default AV delay (120 ms). METHODS AND RESULTS: In 23 CRT patients, biventricular pacing (BiVP) was applied at various AV delays, while recording 10 beats preceding BiVP (baseline) and the first 10 BiVP beats, for both methods in parallel. Agreement between Nexfin and VTIao measurements was evaluated (Bland-Altman) on beat-to-beat changes in SV, as well as on effects of BiVP (averaged over 8 beats) at various AV delays. Individual optimal AV delays, for Nexfin (AVopt-n) and VTIao (AVopt-ao), were derived from the second-order polynomial fitted to the effect measurements of 20 patients. In 252 episodes assessed, the difference between measurements (= Nexfin - VTIao) was -0.6 ± 8.1% for beat-to-beat SV changes and -1.3 ± 7.3% for effects of BiVP. Optimal AV delays for Nexfin were well related to AVopt-ao (R(2) = 0.69). The effect (%) of BiVP at the optimal AV delay was significantly larger than at the default AV delay: median difference (range) being +6.3% (0.1-14.4%; P < 0.001) for VTIao and +4.7% (0.0-14.0%; P < 0.001) for Nexfin. CONCLUSION: Individual AV optimization increases the effect of CRT. Nexfin is a promising tool in individual CRT optimization, as Nexfin agrees with VTIao on measuring beat-to-beat SV changes and on assessing relative effects of BiVP on SV at various AV delays.


Subject(s)
Aorta/physiopathology , Cardiac Resynchronization Therapy , Echocardiography, Doppler/methods , Heart Failure/physiopathology , Heart Failure/therapy , Pulse/methods , Stroke Volume/physiology , Atrioventricular Node/physiopathology , Blood Flow Velocity/physiology , Blood Pressure/physiology , Defibrillators, Implantable , Feasibility Studies , Female , Heart Rate/physiology , Humans , Male , Pacemaker, Artificial , Pulse/instrumentation , Reproducibility of Results , Time Factors
3.
Case Rep Cardiol ; 2011: 624508, 2011.
Article in English | MEDLINE | ID: mdl-24826226

ABSTRACT

We report atrio-ventricular cross talk in a patient with a dual chamber ICD leading to ventricular pacing inhibition. This was observed in an ICD without the ventricular safety pace option, which normally is a sufficient protection against this phenomenon. Cross talk could be prevented effectively by reprogramming ventricular sensitivity to a less sensitive setting.

4.
Am J Physiol Heart Circ Physiol ; 297(6): H2196-205, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19837949

ABSTRACT

In pulmonary arterial hypertension (PAH), duration of myofiber shortening is prolonged in the right ventricular (RV) free wall (RVfw) compared with that in the interventricular septum and left ventricular free wall. This interventricular mechanical asynchrony eventually leads to right heart failure. We investigated by computer simulation whether, in PAH, early RVfw pacing may improve interventricular mechanical synchrony and, hence, cardiac pump function. A mathematical model of the human heart and circulation was used to simulate left ventricular and RV pump mechanics and myofiber mechanics. First, we simulated cardiovascular mechanics of a healthy adult at rest. Size and mass of heart and blood vessels were adapted so that mechanical tissue load was normalized. Second, compensated PAH was simulated by increasing mean pulmonary artery pressure to 32 mmHg while applying load adaptation. Third, decompensated PAH was simulated by increasing mean pulmonary artery pressure further to 79 mmHg without further adaptation. Finally, early RVfw pacing was simulated in severely decompensated PAH. Time courses of circumferential strain in the ventricular walls as simulated were similar to the ones measured in healthy subjects (uniform strain patterns) and in PAH patients (prolonged RVfw shortening). When simulating pacing in decompensated PAH, RV pump function was best upon 40-ms RVfw preexcitation, as evidenced by maximal decrease of RV end-diastolic volume, reduced RVfw myofiber work, and most homogeneous distribution of workload over the ventricular walls. Thus our simulations indicate that, in decompensated PAH, RVfw pacing may improve RV pump function and may homogenize workload over the ventricular walls.


Subject(s)
Cardiac Pacing, Artificial , Computer Simulation , Heart Failure/therapy , Hypertension, Pulmonary/therapy , Models, Cardiovascular , Myocardial Contraction , Ventricular Dysfunction, Right/therapy , Ventricular Function, Right , Adult , Biomechanical Phenomena , Blood Pressure , Heart Failure/etiology , Heart Failure/physiopathology , Humans , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/physiopathology , Severity of Illness Index , Time Factors , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/physiopathology , Ventricular Function, Left
5.
Int J Cardiovasc Imaging ; 22(3-4): 389-92, 2006.
Article in English | MEDLINE | ID: mdl-16502021

ABSTRACT

Although acute pericarditis is a common and usual benign disorder, sometimes evolution to constrictive pericarditis may occur. We present a case of constrictive pericarditis late after coronary bypass grafting, complicated by right sided heart failure. Edema formation was aggravated due to protein-losing enteropathy, resulting in hypoalbuminemia. Imaging of constrictive pericarditis was done by ultrasound as well as simultaneous pressure recording of the right and left ventricle. Imaging of intestinal protein loss was possible using intravenous Technetium-99m-labelled human serum albumin.


Subject(s)
Pericarditis, Constrictive/diagnostic imaging , Protein-Losing Enteropathies/diagnostic imaging , Aged , Echocardiography, Doppler , Heart Ventricles/diagnostic imaging , Humans , Male , Organotechnetium Compounds , Pericardiectomy , Pericarditis, Constrictive/pathology , Pericarditis, Constrictive/surgery , Pericardium/diagnostic imaging , Pericardium/pathology , Pericardium/surgery , Protein-Losing Enteropathies/pathology , Protein-Losing Enteropathies/surgery , Radionuclide Imaging , Serum Albumin
SELECTION OF CITATIONS
SEARCH DETAIL