Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Int J Artif Organs ; 33(10): 749-52, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21058270

ABSTRACT

Hypoxic hepatitis (HH) is a severe complication of postoperative low output syndrome, associated with high mortality rates despite appropriate drug therapy. Recently several extracorporeal supportive techniques have become available. We describe the case of a 70-year-old woman who developed HH secondary to cardiogenic shock after cardiac surgery. CPFA proved to be a valid tool for concomitant hemodynamic support and organ replacement therapy.


Subject(s)
Bilirubin/blood , Cardiac Surgical Procedures/adverse effects , Hemofiltration/methods , Hepatitis/therapy , Hypoxia/therapy , Shock, Cardiogenic/etiology , Acute Disease , Adsorption , Aged , Fatal Outcome , Female , Hemodynamics , Hepatitis/blood , Hepatitis/etiology , Hepatitis/physiopathology , Humans , Hypoxia/blood , Hypoxia/etiology , Hypoxia/physiopathology , Multiple Organ Failure/etiology , Shock, Cardiogenic/physiopathology , Treatment Outcome
2.
Open Dent J ; 4: 191-4, 2010 Sep 15.
Article in English | MEDLINE | ID: mdl-21228920

ABSTRACT

BACKGROUND AND AIMS: Polishing may increase the surface roughness of composites, with a possible effect on bacterial growth and material properties. This preliminary in vitro study evaluates the effect of three different polishing systems (PoGo polishers, Enhance, Venus Supra) on six direct resin composites (Gradia Direct, Venus, Venus Diamond, Enamel Plus HFO, Tetric Evoceram, Filtek Supreme XT). MATERIALS AND METHODS: For each composite, 12 square specimens were prepared: 9 specimens were polished, three for each different method, while three specimens were used as controls. Surface roughness was determined with AFM by measuring Root Mean Square (RMS) of average height. RESULTS: PoGo polisher determined a significantly rougher surface, versus controls, in 5 out of 6 composites evaluated. Some significant differences from unpolished controls were observed also for Enhance polishing. Polishing with Venus Supra did not result in any significant difference in surface roughness versus controls. No differences were observed between different polishing systems. CONCLUSIONS: These preliminary results suggest that Venus Supra polishing system could determine a smoother composite surface if compared to the other polishing systems tested. On this basis, we are conducting an in vivo study to evaluate bacterial colonization on some combinations of composites and polishing protocols.

SELECTION OF CITATIONS
SEARCH DETAIL
...