Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 85(3): 034501, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24689604

ABSTRACT

There is a strong scientific case for the study of gravitational waves at or below the lower end of current detection bands. To take advantage of this scientific benefit, future generations of ground based gravitational wave detectors will need to expand the limit of their detection bands towards lower frequencies. Seismic motion presents a major challenge at these frequencies and vibration isolation systems will play a crucial role in achieving the desired low-frequency sensitivity. A compact vibration isolation system designed to isolate in-vacuum optical benches for Advanced Virgo will be introduced and measurements on this system are used to present its performance. All high performance isolation systems employ an active feedback control system to reduce the residual motion of their suspended payloads. The development of novel control schemes is needed to improve the performance beyond what is currently feasible. Here, we present a multi-channel feedback approach that is novel to the field. It utilizes a linear quadratic regulator in combination with a Kalman state observer and is shown to provide effective suppression of residual motion of the suspended payload. The application of state observer based feedback control for vibration isolation will be demonstrated with measurement results from the Advanced Virgo optical bench suspension system.

2.
Rev Sci Instrum ; 82(9): 094502, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21974605

ABSTRACT

We report an application of Kalman filtering to the inverted pendulum (IP) of the Virgo gravitational wave interferometer. Using subspace method system identification techniques, we calculated a linear mechanical model of Virgo IP from experimental transfer functions. We then developed a Kalman filter, based on the obtained state space representation, that estimates from open loop time domain data, the state variables of the system. This allows the observation (and eventually control) of every resonance mode of the IP mechanical structure independently.

3.
Appl Opt ; 49(25): 4780-90, 2010 Sep 01.
Article in English | MEDLINE | ID: mdl-20842804

ABSTRACT

In-vacuum Faraday isolators (FIs) are used in gravitational wave interferometers to prevent the disturbance caused by light reflected back to the input port from the interferometer itself. The efficiency of the optical isolation is becoming more critical with the increase of laser input power. An in-vacuum FI, used in a gravitational wave experiment (Virgo), has a 20 mm clear aperture and is illuminated by an almost 20 W incoming beam, having a diameter of about 5 mm. When going in vacuum at 10(-6) mbar, a degradation of the isolation exceeding 10 dB was observed. A remotely controlled system using a motorized lambda=2 waveplate inserted between the first polarizer and the Faraday rotator has proven its capability to restore the optical isolation to a value close to the one set up in air.

4.
Phys Rev Lett ; 90(9): 092002, 2003 Mar 07.
Article in English | MEDLINE | ID: mdl-12689215

ABSTRACT

Spin-dependent lepton-nucleon scattering data have been used to investigate the validity of the concept of quark-hadron duality for the spin asymmetry A1. Longitudinally polarized positrons were scattered off a longitudinally polarized hydrogen target for values of Q2 between 1.2 and 12 GeV2 and values of W2 between 1 and 4 GeV2. The average double-spin asymmetry in the nucleon resonance region is found to agree with that measured in deep-inelastic scattering at the same values of the Bjorken scaling variable x. This finding implies that the description of A1 in terms of quark degrees of freedom is valid also in the nucleon resonance region for values of Q2 above 1.6 GeV2.

5.
Phys Rev Lett ; 89(1): 012001, 2002 Jul 01.
Article in English | MEDLINE | ID: mdl-12097034

ABSTRACT

We report on measurements of the cross section and provide first data on spin correlation parameters A(TT') and A(TL') in inclusive scattering of longitudinally polarized electrons from nuclear-polarized hydrogen. Polarized electrons were injected into an electron storage ring operated at a beam energy of 720 MeV. Polarized hydrogen was produced by an atomic beam source and injected into an open-ended cylindrical cell, located in the electron storage ring. The four-momentum transfer squared ranged from Q2 = 0.2 GeV(2)/c(2) at the elastic scattering peak to Q2 = 0.11 GeV(2)/c(2) at the Delta(1232) resonance. The data provide a stringent test of pion electroproduction models.

6.
Phys Rev Lett ; 88(10): 102302, 2002 Mar 11.
Article in English | MEDLINE | ID: mdl-11909349

ABSTRACT

The spin-momentum correlation parameter A(V)(ed) was measured for the 2H-->(e-->,e'p)n reaction for missing momenta up to 350 MeV/c at Q2 = 0.21 (GeV/c)(2) for quasielastic scattering of polarized electrons from vector-polarized deuterium. The data give detailed information about the deuteron spin structure and are in good agreement with the results of microscopic calculations based on realistic nucleon-nucleon potentials and including various spin-dependent reaction mechanism effects. The experiment reveals in a most direct manner the effects of the D state in the deuteron ground-state wave function and shows the importance of isobar configurations for this reaction.

SELECTION OF CITATIONS
SEARCH DETAIL
...