Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 74
Filter
1.
Nuklearmedizin ; 63(3): 213-218, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38378022

ABSTRACT

AIM: The present study evaluated with myocardial perfusion SPECT (MPS) the diagnostic accuracy of an artificial intelligence-enabled vectorcardiography system (Cardisiography, CSG) for detection of perfusion abnormalities. METHODS: We studied 241 patients, 155 with suspected CAD and 86 with known CAD who were referred for MPS. The CSG was performed after the MPS acquisition. The CSG results (1) p-factor (perfusion, 0: normal, 1: mildly, 2: moderately, 3: highly abnormal) and (2) s-factor (structure, categories as p-factor) were compared with the MPS scores. The CSG system was not trained during the study. RESULTS: Considering the p-factor alone, a specificity of >78% and a negative predictive value of mostly >90% for all MPS variables were found. The sensitivities ranged from 17 to 56%, the positive predictive values from 4 to 38%. Combining the p- and the s-factor, significantly higher specificity values of about 90% were reached. The s-factor showed a significant correlation (p=0.006) with the MPS ejection fraction. CONCLUSIONS: The CSG system is able to exclude relevant perfusion abnormalities in patients with suspected or known CAD with a specificity and a negative predictive value of about 90% combining the p- and the s-factor. Since it is a learning system there is potential for further improvement before routine use.


Subject(s)
Artificial Intelligence , Myocardial Perfusion Imaging , Sensitivity and Specificity , Tomography, Emission-Computed, Single-Photon , Vectorcardiography , Humans , Myocardial Perfusion Imaging/methods , Male , Female , Middle Aged , Tomography, Emission-Computed, Single-Photon/methods , Vectorcardiography/methods , Aged , Reproducibility of Results , Coronary Artery Disease/diagnostic imaging , Coronary Disease/diagnostic imaging , Adult
2.
Front Cardiovasc Med ; 10: 1200833, 2023.
Article in English | MEDLINE | ID: mdl-37692049

ABSTRACT

Background: Cardiac magnetic resonance (CMR) imaging allows for multiparametric assessment of healthy pulmonary artery (PA) hemodynamics. Gender- and aging-associated PA stiffness and pressure alterations have remained clinically unestablished, however may demonstrate epidemiological differences in disease development. The aim of this study is to evaluate the role of CMR as a surrogate for catheter examinations by providing a comprehensive CMR assessment of sex- and age-related reference values for PA stiffness, flow, and pressure. Methods and Results: PA hemodynamics were studied between gender and age groups (>/<50 years) using phase-contrast CMR. Corresponding correlation analyses were performed. 179 healthy volunteers with a median age of 32.6 years (range 11.3-68.2) were examined. Males demonstrated increased PA compliance (median [interquartile range] or mean ± standard deviation) (20.8 mm2/mmHg [16.6; 25.8] vs. 19.2 ± 7.1 mm2/mmHg; P < 0.033), higher pulse wave velocity (2.00 m/s [1.35; 2.87] vs. 1.73 m/s [1.19; 2.34]; P = 0.018) and a reduced full width half maximum (FWHM) (219 ± 22 ms vs. 235 ± 23 ms; P < 0.001) than females. Mean, systolic, diastolic PA pressure and pulmonary proportional pulse pressure were significantly elevated for males compared to females (P < 0.001). Older subjects (>50 years) exhibited reduced PA elasticity (41.7% [31.0; 52.9] vs. 66.4% [47.7; 83.0]; P < 0.001), reduced PA compliance (15.4 mm2/mmHg [12.3; 20.7] vs. 21.3 ± 6.8 mm2/mmHg; P < 0.001), higher pulse wave velocity (2.59 m/s [1.57; 3.59] vs. 1.76 m/s [1.24; 2.34]; P < 0.001) and a reduced FWHM (218 ± 29 ms vs. 231 ± 21 ms; P < 0.001) than younger subjects. Conclusions: Velocity-time profiles are dependent on age and gender. PA stiffness indices deteriorate with age. CMR has potential to serve as a surrogate for right heart catheterization.

3.
EJNMMI Phys ; 10(1): 49, 2023 Aug 28.
Article in English | MEDLINE | ID: mdl-37639082

ABSTRACT

BACKGROUND: The use of CT images for attenuation correction of myocardial perfusion imaging with single photon emission computer tomography (SPECT) increases diagnostic confidence. However, acquiring a CT image registered to a SPECT image is often not possible because most scanners are SPECT-only. It is possible to approximate attenuation maps using deep learning, but this has not yet been shown to work for a SPECT scanner with an IQ[Formula: see text]SPECT collimator. This study investigates whether it is possible to approximate attenuation maps from non-attenuation-corrected (nAC) reconstructions acquired with a SPECT scanner equipped with an IQ[Formula: see text]SPECT collimator. METHODS: Attenuation maps and reconstructions were acquired retrospectively for 150 studies. A U-Net was trained to predict attenuation maps from nAC reconstructions using the conditional generative adversarial network framework. Predicted attenuation maps are compared to real attenuation maps using the normalized mean absolute error (NMAE). Attenuation-corrected reconstructions were computed, and the resulting polar maps were compared by pixel and by average perfusion per segment using the absolute percent error (APE). The training and evaluation code is available at https://gitlab.ub.uni-bielefeld.de/thuxohl/mu-map . RESULTS: Predicted attenuation maps are similar to real attenuation maps, achieving an NMAE of 0.020±0.007. The same is true for polar maps generated from reconstructions with predicted attenuation maps compared to CT-based attenuation maps. Their pixel-wise absolute distance is 3.095±3.199, and the segment-wise APE is 1.155±0.769. CONCLUSIONS: It is feasible to approximate attenuation maps from nAC reconstructions acquired by a scanner with an IQ[Formula: see text]SPECT collimator using deep learning.

4.
Diagnostics (Basel) ; 13(14)2023 Jul 20.
Article in English | MEDLINE | ID: mdl-37510168

ABSTRACT

BACKGROUND: Hindered by its unspecific clinical and phenotypical presentation, cardiac sarcoidosis (CS) remains a challenging diagnosis. OBJECTIVE: Utilizing cardiac magnetic resonance imaging (CMR), we acquired multi-chamber volumetrics and strain feature tracking for a support vector machine learning (SVM)-based diagnostic approach to CS. METHOD: Forty-five CMR-negative (CMR(-), 56.5(53.0;63.0)years), eighteen CMR-positive (CMR(+), 64.0(57.8;67.0)years) sarcoidosis patients and forty-four controls (CTRL, 56.5(53.0;63.0)years)) underwent CMR examination. Cardiac parameters were processed using the classifiers of logistic regression, KNN(K-nearest-neighbor), DT (decision tree), RF (random forest), SVM, GBoost, XGBoost, Voting and feature selection. RESULTS: In a three-cluster analysis of CTRL versus vs. CMR(+) vs. CMR(-), RF and Voting classifier yielded the highest prediction rates (81.82%). The two-cluster analysis of CTRL vs. all sarcoidosis (All Sarc.) yielded high prediction rates with the classifiers logistic regression, RF and SVM (96.97%), and low prediction rates for the analysis of CMR(+) vs. CMR(-), which were augmented using feature selection with logistic regression (89.47%). CONCLUSION: Multi-chamber cardiac function and strain-based supervised machine learning provides a non-contrast approach to accurately differentiate between healthy individuals and sarcoidosis patients. Feature selection overcomes the algorithmically challenging discrimination between CMR(+) and CMR(-) patients, yielding high accuracy predictions. The study findings imply higher prevalence of cardiac involvement than previously anticipated, which may impact clinical disease management.

5.
Nuklearmedizin ; 62(4): 235-243, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37268009

ABSTRACT

AIM: This paper presents the results of the 9th survey of myocardial perfusion SPECT (MPS) from the reporting year 2021. METHODS: 218 questionnaires (131 practices (PR), 58 hospitals (HO), 29 university hospitals (UH)) were evaluated. Results of the last survey 2018 are set in squared brackets. RESULTS: MPS data from a total of 133,057 [145,930] patients (-8.8%) with 131,868 [143,707] stress and 106,546 [121,899] rest MPS were analysed. A comparison with official data revealed that 54% all MPS were recorded. From 2018 to 2021, official data showed a every year an increase in MPS numbers. On average, 610 [502] MPS patients (+22%) were examined in each department. 74% [69%] of the responders reported an increase or no changes in their MPS patient numbers. Ambulatory care cardiologists represented as always, the mayor referral group (68% [69%]). For the first time, pharmacological stress was more frequently applied than ergometry (42% [51]). Regadenoson was mostly used. The use of the different protocols remained nearly unchanged. Two-day protocols were predominantly applied (49% [48%]). A shift from multi-headed cameras (58% [72%]) to SPECT-CT systems (24% [17%]) was found. Attenuation correction was performed in 33% [26%] of all MPS. 88% [86%] of all stress, 88% [87%] of all rest and 87% [83%] of all stress and rest MPS were acquired as gated SPECT. 72% [67%] of all departments performed scoring by default. The number of departments without scoring decreased to 13% [16%]. CONCLUSIONS: The MPS Study 2021 shows that the long-term positive development of MPS imaging in Germany is continuing. The COVID-19 pandemia did not change this trend. The procedural and technical details of MPS imaging reveal a high level of guideline conformity.


Subject(s)
COVID-19 , Myocardial Perfusion Imaging , Humans , Myocardial Perfusion Imaging/methods , Tomography, Emission-Computed, Single-Photon , Surveys and Questionnaires , Hospitals, University , Germany/epidemiology , Perfusion
7.
Int J Cardiol Heart Vasc ; 44: 101167, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36632287

ABSTRACT

Background: Right ventricular (RV) strain has provided valuable prognostic information for patients with cardiac amyloidosis (CA). However, the extent to which RV strain and strain rate can differentiate CA is not yet clinically established. CA underdiagnosis delays treatment strategies and exacerbates patient prognosis. Aims: Evaluation of cardiac magnetic resonance (CMR) quantified RV global and regional strain of CA and HCM patients along with CA subtypes. Methods: CMR feature tracking attained longitudinal, radial and circumferential global and regional strain in 47 control subjects (CTRL), 43 CA-, 20 hypertrophic cardiomyopathy- (HCM) patients. CA patients were subdivided in 21 transthyretin-related amyloidosis (ATTR) and 20 acquired immunoglobulin light chain (AL) patients. Strain data and baseline clinical parameters were statistically analysed with respect to diagnostic performance and discriminatory power between the different clinical entities. Results: Effective differentiation of CA from HCM patients was achieved utilizing global longitudinal (GLS: 16.5 ± 3.9% vs. -21.3 ± 6.7%, p = 0.032), radial (GRS: 11.7 ± 5.3% vs. 16.5 ± 7.1%, p < 0.001) and circumferential (GCS: -7.6 ± 4.0% vs. -9.4 ± 4.4%, p = 0.015) right ventricular strain. Highest strain-based hypertrophic phenotype differentiation was attained using GRS (AUC = 0.86). Binomial regression found right ventricular ejection fraction (RV-EF) (p = 0.017) to be a significant predictor of CA-HCM differentiation. CA subtypes had comparable cardiac strains. Conclusion: CMR-derived RV global strains and various regional longitudinal strains provide discriminative radiological features for CA-HCM differentiation. However, in terms of feasibility, cine-derived RV-EF quantification may suffice for efficient differential diagnostic support.

8.
Biomedicines ; 10(12)2022 Nov 22.
Article in English | MEDLINE | ID: mdl-36551760

ABSTRACT

Background: Cardiac amyloidosis (CA) manifests in a hypertrophic phenotype with a poor prognosis, making differentiation from hypertrophic cardiomyopathy (HCM) challenging and delaying early treatment. The extent to which magnetic resonance imaging (MRI) quantifies the right atrial strain (RAS) and strain rate (RASR), providing valuable diagnostic information, is not yet clinically established. Aims: This study assesses diagnostic differences in the longitudinal RAS and RASR between CA and HCM patients, control subjects (CTRL) and CA subtypes in addition to the impact of atrial fibrillation (AF) on the right atrial function in CA patients. The RAS and RASR of tricuspid regurgitation (TR) patients are used to assess the potential for diagnostic overlap. Methods: RAS and RASR quantification was conducted via MRI feature-tracking for biopsy-confirmed CA patients with subtypes identified. Strain parameters were compared for CTRL, HCM and TR patients. Post hoc testing identified intergroup differences. Results: In total, 41 CA patients were compared to 47 CTRL, 20 HCM and 31 TR patients. Reservoir (R), conduit and booster RAS and RASRs allow for significant differentiation (p < 0.001) between CA and HCM patients (R: 10.6 ± 14.3% vs. R: 33.5 ± 16.3%) and CTRL (R: 44.6 ± 15.7%). Booster and reservoir RAS and RASRs qualified as reliable diagnostic tests (AUC > 0.8). CA patients with AF, in contrast to sinus rhythm, demonstrated a significantly impaired reservoir RAS and RASR and booster RASR. The discriminative power of RAS for CA vs. TR was insufficient (R: 10.6% ± 14.3% vs. 7.0% ± 6.0%, p = 0.069). Differentiation between 21 transthyretin and 20 light-chain amyloidosis subtypes was not achievable (R: 0.7% ± 1.0% vs. 0.7% ± 1.0%, p = 0.827). Conclusion: The MRI-derived RAS and RASR are impaired in CA patients and may support noninvasive differentiation between CA, HCM and CTRL.

9.
Diagnostics (Basel) ; 12(11)2022 Nov 04.
Article in English | MEDLINE | ID: mdl-36359536

ABSTRACT

BACKGROUND: This study challenges state-of-the-art cardiac amyloidosis (CA) diagnostics by feeding multi-chamber strain and cardiac function into supervised machine (SVM) learning algorithms. METHODS: Forty-three CA (32 males; 79 years (IQR 71; 85)), 20 patients with hypertrophic cardiomyopathy (HCM, 10 males; 63.9 years (±7.4)) and 44 healthy controls (CTRL, 23 males; 56.3 years (IQR 52.5; 62.9)) received cardiovascular magnetic resonance imaging. Left atrial, right atrial and right ventricular strain parameters and cardiac function generated a 41-feature matrix for decision tree (DT), k-nearest neighbor (KNN), SVM linear and SVM radial basis function (RBF) kernel algorithm processing. A 10-feature principal component analysis (PCA) was conducted using SVM linear and RBF. RESULTS: Forty-one features resulted in diagnostic accuracies of 87.9% (AUC = 0.960) for SVM linear, 90.9% (0.996; Precision = 94%; Sensitivity = 100%; F1-Score = 97%) using RBF kernel, 84.9% (0.970) for KNN, and 78.8% (0.787) for DT. The 10-feature PCA achieved 78.9% (0.962) via linear SVM and 81.8% (0.996) via RBF SVM. Explained variance presented bi-atrial longitudinal strain and left and right atrial ejection fraction as valuable CA predictors. CONCLUSION: SVM RBF kernel achieved competitive diagnostic accuracies under supervised conditions. Machine learning of multi-chamber cardiac strain and function may offer novel perspectives for non-contrast clinical decision-support systems in CA diagnostics.

10.
Echocardiography ; 39(11): 1462-1465, 2022 11.
Article in English | MEDLINE | ID: mdl-36266720

ABSTRACT

Cardiac lipomas are the second most common cardiac tumors. They are usually asymptomatic and diagnosed as incidental findings. We describe a 71-year-old patient with a tumor in the right atrium. In echocardiography and MRI scan, the diagnosis of a cardiac lipoma was suspected. Moreover, MRI demonstrated continuity of pericardial fat and the tumor in the right atrium by infolding of the atrial wall and epicardial adipose tissue in the space between the atrial walls, which might be a hint for the Waterstone groove hypothesis. An operative resection was performed which confirmed the suspected diagnosis.


Subject(s)
Heart Neoplasms , Lipoma , Humans , Aged , Treatment Outcome , Lipoma/complications , Lipoma/diagnostic imaging , Heart Atria/pathology , Heart Neoplasms/complications , Heart Neoplasms/diagnostic imaging , Echocardiography
11.
ESC Heart Fail ; 9(6): 3995-4002, 2022 12.
Article in English | MEDLINE | ID: mdl-35997005

ABSTRACT

AIMS: Implantation of left ventricular-assist devices (LVAD) to treat end-stage heart failure is of increasing relevance due to donor shortage. Infections of the driveline are common adverse events. LVAD infections can lead to high urgency listings for transplantation. However, transplantation in patients with infection leads to worse post-transplantation outcomes. This study aims to evaluate specific risk factors for driveline infections at the time of implantation. METHODS AND RESULTS: Four hundred forty-one patients receiving either Heartmate II or Heartware system from August 2009 to October 2013 were assessed. An expert committee sorted patients into four different groups concerning the likeliness of infection. Twenty-eight (6%) of discussed infection cases were judged as secured, 33 (7%) as likely, 18 (4%) as possible, and 20 (4%) as unlikely. The remaining 342 (78%) subjects showed either no signs of infection at all times (329 [75%]) or developed signs of infection in a second observation period within 1 year after ending of the first observation period (13 [3%]). For a better discriminatory power, cases of secured and likely infections were tested against the group with no infection at all times in a Cox proportional hazard model. Among all variables tested by univariate analysis (significance level P < 0.15), only age (P = 0.07), LVAD-type (P = 0.12), need for another thoracic operation (P = 0.02), and serum creatinine value (P = 0.02) reached statistical significance. These were subsequently subjected to multivariate analysis to calculate the cumulative risk of developing a drive infection. The multivariate analysis showed that of all the potential risk factors tested, only the necessity of re-thoracotomy or secondary thoracic closure had a significant, protective effect (hazard ratio [95% CI] = 0.45 [0.21-0.95]; P = 0.04). CONCLUSION: This single-centre cohort study shows that driveline infections are common adverse events. The duration of support represents the major risk factor for LVAD driveline infections.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Cohort Studies , Heart Failure/epidemiology , Heart Failure/surgery , Heart Failure/etiology , Heart-Assist Devices/adverse effects , Risk Factors
12.
Sci Rep ; 12(1): 12233, 2022 07 18.
Article in English | MEDLINE | ID: mdl-35851289

ABSTRACT

Left-atrial (LA) strain is the result of complex hemodynamics, which may be better characterized using a multiparametric approach. Cardiovascular magnetic resonance (CMR) feature tracking was used to perform a comprehensive LA strain assessment of 183 enrolled healthy volunteers (11-70 years, 97 females, median 32.9 ± 28.3 years). Novel strain dependencies were assessed using multi-parametric regression (MPR) analyses. LA volumetric data, left ventricular strain, transmitral and pulmonary venous blood flow parameters were utilized to create clusters for MPR of all subjects and a heart rate controlled subgroup (pulse: 60-75/min, N = 106). The LA reservoir(r) and conduit(c) strains of the total cohort were significantly elevated (p ≤ 0.001) in women (r: 49.7 ± 12.9%, c: 32.0 ± 11.0%) compared to men (r: 42.9 ± 11.4%, c: 26.1 IQ 10.5%). In contrast, there were no gender-specific differences (p > 0.05) for subgroup LA reservoir, conduit and booster(b) strains (all, r: 47.3 ± 12.7%; c: 29.0 IQ 15.5%; b: 17.6 ± 5.4%) and strain rates (all, 2.1 IQ 1.0 s-1; - 2.9 IQ 1.5 s-1; - 2.3 IQ 1.0 s-1). MPR found large effect sizes (|R2|≥ 0.26) for correlations between strain and various cardiac functional parameters. Largest effect size was found for the association between LA conduit strain and LA indexed booster volume, LA total ejection fraction, left ventricular global radial strain and E-wave (|R2|= 0.437). In addition to providing normal values for sex-dependent LA strain and strain rate, no gender differences were found with modified heart rate. MPR analyses of LA strain/strain rate and various cardiac functional parameters revealed that heart rate control improved goodness-of-fit for the overall model.


Subject(s)
Atrial Function, Left , Magnetic Resonance Imaging, Cine , Atrial Function, Left/physiology , Female , Heart Atria , Humans , Magnetic Resonance Spectroscopy , Male , Stroke Volume
13.
J Clin Med ; 11(11)2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35683537

ABSTRACT

Aims: The present study aims to evaluate magnetic-resonance-imaging (MRI)-assessed left atrial strain (LAS) and left atrial strain rate (LASR) as potential parameters for the diagnosis of cardiac amyloidosis (CA), the distinction of clinical subtypes and differentiation from other cardiomyopathies. Methods and results: LAS and LASR were assessed by MRI feature tracking in patients with biopsy-proven CA. LAS and LASR of patients with CA were compared to healthy subjects and patients with hypertrophic cardiomyopathy. LAS and LASR were also analyzed concerning differences between patients with transthyretin (ATTR) and light chain amyloidosis (AL). A total of 44 patients with biopsy-proven CA, 19 patients with hypertrophic cardiomyopathy and 24 healthy subjects were included. In 22 CA patients (50%), histological examination identified ATTR as CA subtype and AL in the remaining patients. No significant difference was observed for reservoir, conduit or booster LAS in patients with AL or ATTR. Reservoir LAS, conduit LAS and booster LAS were significantly reduced in patients with CA and HCM as compared to healthy subjects (p < 0.001). Reservoir LAS and booster LAS were significantly reduced in CA as compared to HCM patients (p < 0.001). A linear correlation was observed between LA global reservoir strain and LA-EF (p < 0.001, r = 0.5), conduit strain and global longitudinal LV strain (p < 0.001, r = 0.5), global booster strain rate and LA-EF (p < 0.001, r = 0.6) and between global booster strain rate and LA area at LVED (p < 0.0001, 0.5). Conclusions: LAS and LASR are severely impaired in patients with CA. The MRI-based assessment of LAS and LASR might allow non-invasive diagnosis and categorization of CA and its distinct differentiation from other hypertrophic phenotypes.

14.
Nuklearmedizin ; 61(4): 294-300, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35388444

ABSTRACT

AIM: Recently, dose reference levels (DRLs) have been defined in Germany for auxiliary low-dose CT scans in hybrid SPECT/CT and PET/CT examinations, based on data from 2016/17. Here, another survey from 2020 was evaluated and compared with the new DRLs as well as with similar surveys from foreign countries. METHODS: The survey, which had already been conducted in the Nordic countries, queried for various examinations including the following values: patient weight and height, volume CT dose index (CTDIvol), dose length product (DLP). For each examination, statistical parameters such as the third quartile (Q3) were determined from all submitted CTDIvol and DLP values. Additionally, for examinations comprising datasets from at least 10 systems, the third quartile (Q3-Med) of the respective median values of each system was calculated. Q3 and Q3-Med were compared with the newly published DRLs from Germany and values from similar studies from other countries. RESULTS: Data from 15 SPECT/CT and 13 PET/CT systems from 15 nuclear medicine departments were collected. For the following examinations datasets from more than 10 systems were submitted: SPECT lung VQ, SPECT bone, SPECT&PET cardiac, PET brain, PET oncology. Especially for examinations of the thorax and heart, the new DRLs are very strict compared to this study. The CTDIvol values for examinations of the head were lower in this study than the DRLs prescribe now. CONCLUSIONS: For certain examination types, there is a need for dose optimization at some clinics and devices in order to take into account the new DRLs in Germany in the future.


Subject(s)
Positron Emission Tomography Computed Tomography , Tomography, X-Ray Computed , Germany , Humans , Radiation Dosage , Reference Values , Single Photon Emission Computed Tomography Computed Tomography , Tomography, X-Ray Computed/methods
15.
JACC Cardiovasc Imaging ; 15(6): 1107-1120, 2022 06.
Article in English | MEDLINE | ID: mdl-35033495

ABSTRACT

BACKGROUND: Bioprosthetic valve thrombosis may have implications for valve function and durability. OBJECTIVES: Using a novel glycoprotein IIb/IIIa receptor radiotracer 18F-GP1, we investigated whether positron emission tomography (PET)-computed tomography (CT) could detect thrombus formation on bioprosthetic aortic valves. METHODS: Ex vivo experiments were performed on human platelets and explanted bioprosthetic aortic valves. In a prospective cross-sectional study, patients with either bioprosthetic or normal native aortic valves underwent echocardiography, CT angiography, and 18F-GP1 PET-CT. RESULTS: Flow cytometric analysis, histology, immunohistochemistry, and autoradiography demonstrated selective binding of 18F-GP1 to activated platelet glycoprotein IIb/IIIa receptors and thrombus adherent to prosthetic valves. In total, 75 participants were recruited: 53 with bioprosthetic valves (median time from implantation 37 months [IQR: 12-80 months]) and 22 with normal native aortic valves. Three participants had obstructive valve thrombosis, and a further 3 participants had asymptomatic hypoattenuated leaflet thickening on CT angiography. All bioprosthetic valves, but none of the native aortic valves, demonstrated focal 18F-GP1 uptake on the valve leaflets: median maximum target-to-background ratio 2.81 (IQR: 2.29-3.48) vs 1.43 (IQR: 1.28-1.53) (P < 0.001). Higher 18F-GP1 uptake was independently associated with duration of valve implantation and hypoattenuated leaflet thickening. All 3 participants with obstructive valve thrombosis were anticoagulated for 3 months, leading to resolution of their symptoms, improvement in mean valve gradients, and a reduction in 18F-GP1 uptake. CONCLUSIONS: Adherence of activated platelets is a common and sustained finding on bioprosthetic aortic valves. 18F-GP1 uptake is higher in the presence of thrombus, regresses with anticoagulation, and has potential use as an adjunctive clinical tool. (18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis; NCT04073875).


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Thrombosis , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Cross-Sectional Studies , Humans , Positron Emission Tomography Computed Tomography , Positron-Emission Tomography , Predictive Value of Tests , Prospective Studies , Thrombosis/diagnostic imaging , Thrombosis/etiology
16.
Front Cardiovasc Med ; 8: 764496, 2021.
Article in English | MEDLINE | ID: mdl-34796219

ABSTRACT

Aims: Cardiac strain parameters are increasingly measured to overcome shortcomings of ejection fraction. For broad clinical use, this study provides reference values for the two strain assessment methods feature tracking (FT) and fast strain-encoded (fSENC) cardiovascular magnetic resonance (CMR) imaging, including the child/adolescent group and systematically evaluates the influence of temporal resolution and muscle mass on strain. Methods and Results: Global longitudinal (GLS), circumferential (GCS), and radial (GRS) strain values in 181 participants (54% women, 11-70 years) without cardiac illness were assessed with FT (CVI42® software). GLS and GCS were also analyzed using fSENC (MyoStrain® software) in a subgroup of 84 participants (60% women). Fourteen patients suffering hypertrophic cardiomyopathy (HCM) were examined with both techniques. CMR examinations were done on a 3.0T MR-system. FT-GLS, FT-GCS, and FT-GRS were -16.9 ± 1.8%, -19.2 ± 2.1% and 34.2 ± 6.1%. fSENC-GLS was higher at -20.3 ± 1.8% (p < 0.001). fSENC-GCS was comparable at-19.7 ± 1.8% (p = 0.06). All values were lower in men (p < 0.001). Cardiac muscle mass correlated (p < 0.001) with FT-GLS (r = 0.433), FT-GCS (r = 0.483) as well as FT-GRS (r = -0.464) and acts as partial mediator for sex differences. FT-GCS, FT-GRS and fSENC-GLS correlated weakly with age. FT strain values were significantly lower at lower cine temporal resolutions, represented by heart rates (r = -0.301, -0.379, 0.385) and 28 or 45 cardiac phases per cardiac cycle (0.3-1.9% differences). All values were lower in HCM patients than in matched controls (p < 0.01). Cut-off values were -15.0% (FT-GLS), -19.3% (FT-GCS), 32.7% (FT-GRS), -17.2% (fSENC-GLS), and -17.7% (fSENC-GCS). Conclusion: The analysis of reference values highlights the influence of gender, temporal resolution, cardiac muscle mass and age on myocardial strain values.

18.
Pharmaceuticals (Basel) ; 14(8)2021 Jul 28.
Article in English | MEDLINE | ID: mdl-34451836

ABSTRACT

Thrombus formation and thromboembolic events play important roles in various cardiovascular pathologies. The key receptor involved in platelet aggregation is the fibrinogen receptor glycoprotein IIb/IIIa. [18F]GP1, a derivative of the GPIIb/IIIa antagonist elarofiban, is a specific 18F-labeled small-molecule radiotracer that binds with high affinity to GPIIb/IIIa receptors of activated platelets. An improved, robust and fully automated radiosynthesis of [18F]GP1 has been developed. [18F]GP1 has been synthesized with decay corrected radiochemical yields of 38 ± 6%, with a radiochemical concentration up to 1900 MBq/mL, molar activities of 952-9428 GBq/µmol and a radio-chemical purity >98%. After determination of the optimal reaction conditions, in particular for HPLC separation, adaption of the reaction conditions to PET center requirements, validation of the manufacturing process and the quality control methods, the synthesis of [18F]GP1 was successfully implemented to GMP standards and was available for clinical application. We describe the GMP-compliant synthesis of the novel radiotracer [18F]GP1. Moreover, we provide some proof-of-concept examples for clinical application in the cardiovascular field. PET/CT with the novel small-molecular radiotracer [18F]GP1 may serve as a novel highly sensitive tool for visualizing active platelet aggregation at the molecular level.

19.
Nucl Med Commun ; 42(8): 884-891, 2021 Aug 01.
Article in English | MEDLINE | ID: mdl-33741851

ABSTRACT

AIMS: The study aimed to investigate whether additional prone imaging delivers comparable results to supine imaging with low-dose computed tomography (CT) attenuation correction (CTAC) in cadmium, zinc and telluride (CZT) myocardial perfusion imaging. METHODS AND RESULTS: Thirty-four patients with an indication for myocardial perfusion imaging were studied with a CZT camera in the supine and then prone position. Furthermore, a low-dose CT was acquired. Three data sets were reconstructed and considered for analysis: (1) supine CZT, (2) supine CZT with CTAC and (3) supine CZT with additional prone CZT. Based on 17-segment polartomograms, we compared radiopharmaceutical uptake percentage, summed stress score (SSS), summed rest score (SRS), summed difference score (SDS), total ischemic and scarred segments, and finally scan classification and clinical decision-making. SSS of supine/supine-CTAC/supine-prone was 341/229/253 (P < 0.05), SRS was 246/156/164 (P < 0.05) and SDS was 104/88/96 (ns), respectively. Total ischemic segments were 65/67/65 (ns) and total scarred segments 96/62/69 (P < 0.05), respectively. The frequency of normal scans was highest for supine-prone, followed by supine-CTAC and supine (41/35/24%, respectively). Supine imaging indicated 23% of patients for invasive coronary angiography, both supine-CTAC and supine-prone 18%. These two showed a significant intercorrelation. CONCLUSION: Additional prone imaging and CTAC are mainly correct for the amount and extent of myocardial scars. Both methods increase the frequency of normal scans and show a significant agreement in clinical decision-making. Additional prone imaging appears as a useful alternative when a low-dose CT for attenuation correction is not available.


Subject(s)
Myocardial Perfusion Imaging , Aged , Cadmium , Gamma Cameras , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...