Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38967238

ABSTRACT

Molten salts have a significant potential for use as next-generation nuclear reactor coolants and in pyroprocessing for the recycling of used nuclear fuel. However, the molten salt composition needs to be known at all times, and high temperatures and intense ionizing radiation pose challenges for the monitoring instrumentation. Although the technique of laser-induced breakdown spectroscopy (LIBS) has been studied for in situ measurements of molten salts, trials to improve its monitoring accuracy using chemometrics are lacking. In this study, a data fusion technique using the LIBS optical and laser-induced acoustic (LIA) signals was investigated to enhance the measurement accuracy for molten salt monitoring. Prediction models were constructed using the partial least-squares method, and the variable importance in projection scores was analyzed to evaluate the effect of incorporating the LIA signal into the analysis. This study investigates rare earth elements Eu, Er, and Pr found not only in nuclear but also in other settings such as laser and magnetic materials. The analysis of LIBS data without data fusion resulted in a root-mean-square error of prediction (RMSEP) of 0.0774-0.0913 wt %, whereas the prediction model using data fusion led to approximately 18-40% enhanced RMSEP (0.0461-0.0679 wt %). The results suggest that fusing the LIBS data with the simultaneously recorded LIA data can improve the monitoring accuracy of rare earth element composition in molten salts.

2.
Sensors (Basel) ; 23(23)2023 Nov 23.
Article in English | MEDLINE | ID: mdl-38067747

ABSTRACT

The optical filament-based radioxenon sensing can potentially overcome the constraints of conventional detection techniques that are relevant for nuclear security applications. This study investigates the spectral signatures of pure xenon (Xe) when excited by ultrafast laser filaments at near-atmosphericpressure and in short and loose-focusing conditions. The two focusing conditions lead to laser intensity differences of several orders of magnitude and different plasma transient behavior. The gaseous sample was excited at atmospheric pressure using ∼7 mJ pulses with a 35 fs pulse duration at 800 nm wavelength. The optical signatures were studied by time-resolved spectrometry and imaging in orthogonal light collection configurations in the ∼400 nm (VIS) and ∼800 nm (NIR) spectral regions. The most prominent spectral lines of atomic Xe are observable in both focusing conditions. An on-axis light collection from an atmospheric air-Xe plasma mixture demonstrates the potential of femtosecond filamentation for the remote sensing of noble gases.

3.
Sensors (Basel) ; 23(2)2023 Jan 07.
Article in English | MEDLINE | ID: mdl-36679488

ABSTRACT

Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3σ detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 × 1017 n/cm2 neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 ± 610 K to 6900 ± 810 K and from 15,800 ± 400 K to 7200 ± 800 K, respectively, for exposure to the 1.7 × 1017 n/cm2 fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.


Subject(s)
Aluminum Oxide , Data Analysis , Male , Humans , Glass , Radiation, Ionizing , Spectrum Analysis
4.
Sci Rep ; 12(1): 17205, 2022 10 13.
Article in English | MEDLINE | ID: mdl-36229516

ABSTRACT

Plants and other photosynthetic organisms have been suggested as potential pervasive biosensors for nuclear nonproliferation monitoring. We demonstrate that ultrafast laser filament-induced fluorescence of chlorophyll in the green alga Chlamydomonas reinhardtii is a promising method for remote, in-field detection of stress from exposure to nuclear materials. This method holds an advantage over broad-area surveillance, such as solar-induced fluorescence monitoring, when targeting excitation of a specific plant would improve the detectability, for example when local biota density is low. After exposing C. reinhardtii to uranium, we find that the concentration of chlorophyll a, chlorophyll fluorescence lifetime, and carotenoid content increase. The increased fluorescence lifetime signifies a decrease in non-photochemical quenching. The simultaneous increase in carotenoid content implies oxidative stress, further confirmed by the production of radical oxygen species evidence in the steady-state absorption spectrum. This is potentially a unique signature of uranium, as previous work finds that heavy metal stress generally increases non-photochemical quenching. We identify the temporal profile of the chlorophyll fluorescence to be a distinguishing feature between uranium-exposed and unexposed algae. Discrimination of uranium-exposed samples is possible at a distance of [Formula: see text]35 m with a single laser shot and a modest collection system, as determined through a combination of experiment and simulation of distance-scaled uncertainty in discriminating the temporal profiles. Illustrating the potential for remote detection, detection over 125 m would require 100 laser shots, commensurate with the detection time on the order of 1 s.


Subject(s)
Chlamydomonas reinhardtii , Uranium , Carotenoids , Chlorophyll/chemistry , Chlorophyll A , Fluorescence , Oxygen , Photosynthesis
5.
Rev Sci Instrum ; 92(10): 105107, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34717420

ABSTRACT

The use of optical instrumentation in advanced nuclear fission systems, such as molten salt reactors, liquid metal-cooled reactors, and high-temperature gas-cooled reactors, has the potential to enhance reactor safety and economic performance through in situ and online measurement of reactor conditions. Selection of suitable optical components, such as optical windows and fibers, is essential for operation of optical instrumentation in intense radioactive and thermal environments inherent to nuclear reactor systems. We present the development and performance of a self-contained and mobile post-irradiation examination system for rapid characterization of the optical properties of materials. The instrument combines linear absorption and nanosecond Z-scan modules in a compact, relocatable design. The system mobility allows for the evaluation of optical samples at the site of irradiation, minimizing the delay between extraction from the irradiation site and optical characterization. This provides nearly real-time information on the material performance under simultaneous irradiation and thermal annealing, simulating the relevant conditions for the use of those components in nuclear power systems.

6.
Opt Lett ; 46(15): 3777-3780, 2021 Aug 01.
Article in English | MEDLINE | ID: mdl-34329279

ABSTRACT

Ultrashort laser pulse filamentation in air can extend the delivery of focused laser energy to distances greatly exceeding the Rayleigh length. In this way, remote measurements can be conducted using many standard methods of analytical spectroscopy. The performance of spectroscopic techniques can be enhanced by temporal gating, which rejects the unwanted noise and background. In the present work, we investigate the thermal relaxation of air in the wake of single-filament plasmas using shadowgraphy. We demonstrate that the transient change in refractive index associated with relaxation of the gas can be used to reject both continuous and time-varying spectroscopic signals, including emission from laser-produced plasmas. This method can augment temporal gating of simple optical detectors.

7.
Phys Rev E ; 96(5-1): 053210, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29347637

ABSTRACT

Laboratory plasmas inherently exhibit temperature and density gradients leading to complex investigations. We show that plasmas generated by laser ablation can constitute a robust exception to this. Supported by emission features not observed with other sources, we achieve plasmas of various compositions which are both uniform and in local thermodynamic equilibrium. These properties characterize an ideal radiation source opening multiple perspectives in plasma spectroscopy. The finding also constitutes a breakthrough in the analytical field as fast analyses of complex materials become possible.

SELECTION OF CITATIONS
SEARCH DETAIL
...