Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Surg Innov ; 30(6): 720-727, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37831491

ABSTRACT

BACKGROUND: Competition-based learning (CBL) facilitates learning through competitions. At the 2022 & 2023 Annual SAGES meetings, we evaluated a CBL experience (TOP GUN Shootout) developed from a modified version of the previously validated TOP GUN Laparoscopic Skills and Suturing Program. The project sought to evaluate the TOP GUN Shootout's (TGS) ability to enhance participant engagement in pursuit of laparoscopic surgical skills. METHODS: Participants competed in the TGS. Their scores (time and errors) were recorded for: Fundamentals of Laparoscopic Surgery Peg Pass, Cup Drop Task, and Intracorporeal Suturing. All participants completed a 10-question satisfaction survey on a 7-point Likert scale, with questions assessing 3 domains: (1) capability/confidence in MIS skill performance prior to the competition; (2) applicability and satisfaction with TGS's capacity to develop MIS skills; and (3) interest in seeking additional MIS training and appropriateness of CBL in MIS training. Descriptive statistics were used to evaluate these areas. RESULTS: Overall, 121 participants completed the TGS, of whom 84 (69%) completed the satisfaction survey. The average age was 32.9 years, 67% were males. On average (+/- SD), participant satisfaction was 5.04 (+/- 2.08) for Domain 1, 6.20 (+/- 1.28) for Domain 2, and 6.58 (+/- .95) for Domain 3. CONCLUSION: Participants described an overall lack of confidence in their MIS skills prior to the 2022-2023 Annual SAGES conference. Participants felt that this brief CBL experience, aided in the development of their MIS skills. Furthermore, this brief CBL experience may inspire learners to seek out further training of their MIS skills.


Subject(s)
Internship and Residency , Laparoscopy , Male , Humans , Adult , Female , Clinical Competence , Laparoscopy/education , Surveys and Questionnaires , Neurosurgical Procedures
2.
J Neural Eng ; 2022 May 24.
Article in English | MEDLINE | ID: mdl-35609552

ABSTRACT

OBJECTIVE: Long-term electroencephalogram (EEG) recordings can aid diagnosis and management of various neurological conditions such as epilepsy. In this study we characterize the safety and stability of a clinical grade ring electrode arrays by analyzing EEG recordings, fluoroscopy, and computed tomography (CT) imaging with long-term implantation and histopathological tissue response. APPROACH: Seven animals were chronically implanted with EEG recording array consisting of four electrode contacts. Recordings were made bilaterally using a bipolar longitudinal montage. The array was connected to a fully implantable micro-processor controlled electronic device with two low-noise differential amplifiers and a transmitter-receiver coil. An external wearable was used to power, communicate with the implant via an inductive coil, and store the data. The sub-scalp electrode arrays were made using medical grade silicone and platinum. The electrode arrays were tunneled in the subgaleal cleavage plane between the periosteum and the overlying dermis. These were implanted for 3-7 months before euthanasia and histopathological assessment. EEG and impedance were recorded throughout the study. MAIN RESULTS: Impedance measurements remained low throughout the study for 11 of 12 channels over the recording period ranged from 3 to 5 months. There was also a steady amplitude of slow-wave EEG and chewing artifact (noise). The post-mortem CT and histopathology showed the electrodes remained in the subgaleal plane in 6 of 7 sheep. There was minimal inflammation with a thin fibrotic capsule that ranged from 4 to 101µm. There was a variable fibrosis in the subgaleal plane extending from 210 to 3617µm (S3-S7) due to surgical cleavage. One sheep had an inflammatory reaction due to electrode extrusion. The passive electrode array extraction force was around 1N. SIGNIFICANCE: Results show sub-scalp electrode placement was safe and stable for long term implantation. This is advantageous for diagnosis and management of neurological conditions where long-term, EEG monitoring is required.

3.
J Neural Eng ; 17(4): 045014, 2020 08 05.
Article in English | MEDLINE | ID: mdl-32659750

ABSTRACT

OBJECTIVE: Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. APPROACH: A prototype implant containing up to twenty-five 120 × 120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. MAIN RESULTS: The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in eight animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. SIGNIFICANCE: The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.


Subject(s)
Diamond , Visual Prosthesis , Animals , Cats , Electric Stimulation , Electrodes , Electrodes, Implanted , Feasibility Studies , Retina
4.
Bioelectricity ; 2(4): 391-398, 2020 Dec 01.
Article in English | MEDLINE | ID: mdl-34476368

ABSTRACT

Background: Cardiomyocytes derived from pluripotent stem cells are immature. Maturation of cardiomyocytes is a multifactorial dynamic process that involves various factors in vivo that cannot be fully recapitulated in vitro. Here, we report a novel tissue engineering chamber with an integrated electrical stimulator and electrodes that will allow wireless electrical stimulation of cardiac tissue in vivo. Materials and Methods: Immunocompromised rats were implanted with tissue engineering chambers containing the stimulator and electrodes, and control chambers (chambers with electrical stimulator but without the electrodes) in the contralateral limb. Each chamber contained cardiomyocytes derived from human induced pluripotent stem cells (iPSCs). After 7 days of chamber implantation, the electrical stimulators were activated for 4 h per day, for 21 consecutive days. Results: At 4 weeks postimplantation, cardiomyocytes derived from human iPSCs survived, were assembled into compact cardiac tissue, and were perfused and vascularized by the host neovessels. Conclusion: This proof-of-principle study demonstrates the biocompatibility of the tissue engineering chamber with integrated electrical stimulator and electrodes. This could be utilized to study the influence of continuous electrical stimulation on vascularized cardiac or other tissues in vivo.

5.
Front Neurosci ; 13: 418, 2019.
Article in English | MEDLINE | ID: mdl-31133776

ABSTRACT

Electrical stimulation of the cervical vagus nerve is an emerging treatment for inflammatory bowel disease (IBD). However, side effects from cervical vagal nerve stimulation (VNS) are often reported by patients. Here we hypothesized that stimulating the vagus nerve closer to the end organ will have fewer off-target effects and will effectively reduce intestinal inflammation. Specifically, we aimed to: (i) compare off-target effects during abdominal and cervical VNS; (ii) verify that VNS levels were suprathreshold; and (iii) determine whether abdominal VNS reduces chemically-induced intestinal inflammation in rats. An electrode array was developed in-house to stimulate and record vagal neural responses. In a non-recovery experiment, stimulation-induced off-target effects were measured by implanting the cervical and abdominal vagus nerves of anaesthetized rats (n = 5) and recording changes to heart rate, respiration and blood pressure during stimulation (10 Hz; symmetric biphasic current pulse; 320 nC per phase). In a chronic experiment, the efficacy of VNS treatment was assessed by implanting an electrode array onto the abdominal vagus nerve and recording in vivo electrically-evoked neural responses during the implantation period. After 14 days, the intestine was inflamed with TNBS (2.5% 2,4,6-trinitrobenzene sulphonic acid) and rats received therapeutic VNS (n = 7; 10 Hz; 320 nC per phase; 3 h/day) or no stimulation (n = 8) for 4.5 days. Stool quality, plasma C-reactive protein and histology of the inflamed intestine were assessed. Data show that abdominal VNS had no effect (two-way RM-ANOVA: P ≥ 0.05) on cardiac, respiratory and blood pressure parameters. However, during cervical VNS heart rate decreased by 31 ± 9 beats/minute (P ≥ 0.05), respiration was inhibited and blood pressure decreased. Data addressing efficacy of VNS treatment show that electrically-evoked neural response thresholds remained stable (one-way RM ANOVA: P ≥ 0.05) and therapeutic stimulation remained above threshold. Chronically stimulated rats, compared to unstimulated rats, had improved stool quality (two-way RM ANOVA: P < 0.0001), no blood in feces (P < 0.0001), reduced plasma C-reactive protein (two-way RM ANOVA: P < 0.05) and a reduction in resident inflammatory cell populations within the intestine (Kruskal-Wallis: P < 0.05). In conclusion, abdominal VNS did not evoke off-target effects, is an effective treatment of TNBS-induced inflammation, and may be an effective treatment of IBD in humans.

6.
J Neural Eng ; 15(4): 041004, 2018 08.
Article in English | MEDLINE | ID: mdl-29756600

ABSTRACT

OBJECTIVE: Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technology. APPROACH: The present review examines basic design principles associated with the development of a safe neural stimulator and describes the suite of preclinical safety studies that need to be considered when taking a device to clinical trial. MAIN RESULTS: Neural stimulators are active implantable devices that provide therapeutic intervention, sensory feedback or improved motor control via electrical stimulation of neural or neuro-muscular tissue in response to trauma or disease. Because of their complexity, regulatory bodies classify these devices in the highest risk category (Class III), and they are therefore required to go through a rigorous regulatory approval process before progressing to market. The successful development of these devices is achieved through close collaboration across disciplines including engineers, scientists and a surgical/clinical team, and the adherence to clear design principles. Preclinical studies form one of several key components in the development pathway from concept to product release of neural stimulators. Importantly, these studies provide iterative feedback in order to optimise the final design of the device. Key components of any preclinical evaluation include: in vitro studies that are focussed on device reliability and include accelerated testing under highly controlled environments; in vivo studies using animal models of the disease or injury in order to assess efficacy and, given an appropriate animal model, the safety of the technology under both passive and electrically active conditions; and human cadaver and ex vivo studies designed to ensure the device's form factor conforms to human anatomy, to optimise the surgical approach and to develop any specialist surgical tooling required. SIGNIFICANCE: The pipeline from concept to commercialisation of these devices is long and expensive; careful attention to both device design and its preclinical evaluation will have significant impact on the duration and cost associated with taking a device through to commercialisation. Carefully controlled in vitro and in vivo studies together with ex vivo and human cadaver trials are key components of a thorough preclinical evaluation of any new neural stimulator.


Subject(s)
Deep Brain Stimulation/methods , Equipment Design/methods , Implantable Neurostimulators , Animals , Deep Brain Stimulation/instrumentation , Deep Brain Stimulation/trends , Equipment Design/trends , Humans , Implantable Neurostimulators/trends , Nervous System Diseases/physiopathology , Nervous System Diseases/therapy , Treatment Outcome
7.
Invest Ophthalmol Vis Sci ; 59(3): 1410-1424, 2018 03 01.
Article in English | MEDLINE | ID: mdl-29625464

ABSTRACT

Purpose: Following successful clinical outcomes of the prototype suprachoroidal retinal prosthesis, Bionic Vision Australia has developed an upgraded 44-channel suprachoroidal retinal prosthesis to provide a wider field of view and more phosphenes. The aim was to evaluate the preclinical passive safety characteristics of the upgraded electrode array. Methods: Ten normal-sighted felines were unilaterally implanted with an array containing platinum electrodes (44 stimulating and 2 returns) on a silicone carrier near the area centralis. Clinical assessments (color fundus photos, optical coherence tomography, full-field electroretinography, intraocular pressure) were performed under anesthesia prior to surgery, and longitudinally for up to 20 weeks. Histopathology grading of fibrosis and inflammation was performed in two animals at 13 to 15 weeks. Results: Eight animals showed safe electrode array insertion (good retinal health) and good conformability of the array to the retinal curvature. Eight animals demonstrated good mechanical stability of the array with only minor (<2 disc diameters) lateral movement. Four cases of surgical or stability complications occurred due to (1) bulged choroid during surgery, (2) hemorrhage from a systemic bleeding disorder, (3) infection, and (4) partial erosion of thin posterior sclera. There was no change in retinal structure or function (other than that seen at surgery) at endpoint. Histopathology showed a mild foreign body response. Electrodes were intact on electrode array removal. Conclusions: The 44-channel suprachoroidal electrode array has an acceptable passive safety profile to proceed to clinical trial. The safety profile is expected to improve in human studies, as the complications seen are specific to limitations (anatomic differences) with the feline model.


Subject(s)
Choroid/surgery , Electrodes, Implanted , Microelectrodes , Prosthesis Implantation , Retina/surgery , Visual Prosthesis , Animals , Cats , Disease Models, Animal , Electrodes, Implanted/adverse effects , Prosthesis Implantation/adverse effects , Visual Prosthesis/adverse effects
8.
Artif Organs ; 40(3): E12-24, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26416723

ABSTRACT

Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.


Subject(s)
Magnets/chemistry , Prosthesis Implantation/methods , Retina/surgery , Visual Prosthesis/chemistry , Animals , Cats , Electrodes, Implanted , Hot Temperature , Magnetics/methods , Prosthesis Design , Retina/ultrastructure
9.
Biomaterials ; 53: 464-74, 2015.
Article in English | MEDLINE | ID: mdl-25890743

ABSTRACT

As the field of biomedical implants matures the functionality of implants is rapidly increasing. In the field of neural prostheses this is particularly apparent as researchers strive to build devices that interact with highly complex neural systems such as vision, hearing, touch and movement. A retinal implant, for example, is a highly complex device and the surgery, training and rehabilitation requirements involved in deploying such devices are extensive. Ideally, such devices will be implanted only once and will continue to function effectively for the lifetime of the patient. The first and most pivotal factor that determines device longevity is the encapsulation that separates the sensitive electronics of the device from the biological environment. This paper describes the realisation of a free standing device encapsulation made from diamond, the most impervious, long lasting and biochemically inert material known. A process of laser micro-machining and brazing is described detailing the fabrication of hermetic electrical feedthroughs and laser weldable seams using a 96.4% gold active braze alloy, another material renowned for biochemical longevity. Accelerated ageing of the braze alloy, feedthroughs and hermetic capsules yielded no evidence of corrosion and no loss of hermeticity. Samples of the gold braze implanted for 15 weeks, in vivo, caused minimal histopathological reaction and results were comparable to those obtained from medical grade silicone controls. The work described represents a first account of a free standing, fully functional hermetic diamond encapsulation for biomedical implants, enabled by gold active alloy brazing and laser micro-machining.


Subject(s)
Alloys , Biocompatible Materials , Diamond , Gold , Neural Prostheses , Zinc Oxide-Eugenol Cement , Animals , Guinea Pigs
10.
Clin Exp Ophthalmol ; 42(7): 665-74, 2014.
Article in English | MEDLINE | ID: mdl-24330322

ABSTRACT

BACKGROUND: Current surgical techniques for retinal prosthetic implantation require long and complicated surgery, which can increase the risk of complications and adverse outcomes. METHOD: The suprachoroidal position is known to be an easier location to access surgically, and so this study aimed to develop a surgical procedure for implanting a prototype suprachoroidal retinal prosthesis. The array implantation procedure was developed in 14 enucleated eyes. A full-thickness scleral incision was made parallel to the intermuscular septum and superotemporal to the lateral rectus muscle. A pocket was created in the suprachoroidal space, and the moulded electrode array was inserted. The scleral incision was closed and scleral anchor point sutured. In 9 of the 14 eyes examined, the device insertion was obstructed by the posterior ciliary neurovascular bundle. Subsequently, the position of this neurovascular bundle in 10 eyes was characterized. Implantation and lead routing procedure was then developed in six human cadavers. The array was tunnelled forward from behind the pinna to the orbit. Next, a lateral canthotomy was made. Lead fixation was established by creating an orbitotomy drilled in the frontal process of the zygomatic bone. The lateral rectus muscle was detached, and implantation was carried out. Finally, pinna to lateral canthus measurements were taken on 61 patients in order to determine optimal lead length. RESULTS: These results identified potential anatomical obstructions and informed the anatomical fitting of the suprachoroidal retinal prosthesis. CONCLUSION: As a result of this work, a straightforward surgical approach for accurate anatomical suprachoroidal array and lead placement was developed for clinical application.


Subject(s)
Choroid/surgery , Ophthalmologic Surgical Procedures , Prosthesis Implantation/methods , Visual Prosthesis , Cadaver , Female , Humans , Male , Materials Testing , Surgical Flaps , Suture Techniques , Tissue Donors
11.
Tissue Eng Part A ; 16(5): 1469-77, 2010 May.
Article in English | MEDLINE | ID: mdl-20001254

ABSTRACT

Branched vascular networks are a central component of scaffold architecture for solid organ tissue engineering. In this work, seven biomimetic principles were established as the major guiding technical design considerations of a branched vascular network for a tissue-engineered scaffold. These biomimetic design principles were applied to a branched radial architecture to develop a liver-specific vascular network. Iterative design changes and computational fluid dynamic analysis were used to optimize the network before mold manufacturing. The vascular network mold was created using a new mold technique that achieves a 1:1 aspect ratio for all channels. In vitro blood flow testing confirmed the physiologic hemodynamics of the network as predicted by computational fluid dynamic analysis. These results indicate that this biomimetic liver vascular network design will provide a foundation for developing complex vascular networks for solid organ tissue engineering that achieve physiologic blood flow.


Subject(s)
Biomimetic Materials/pharmacology , Blood Vessels/drug effects , Liver/blood supply , Liver/drug effects , Tissue Engineering/methods , Tissue Scaffolds/chemistry , Blood Circulation/drug effects , Blood Circulation/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...