Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Entropy (Basel) ; 26(4)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38667850

ABSTRACT

BACKGROUND: Early detection of atrial fibrillation (AF) is essential to prevent stroke and other cardiac and embolic complications. We compared the diagnostic properties for AF detection of the percentage of successive RR interval differences greater than or equal to 30 ms or 3.25% of the previous RR interval (pRR30 and pRR3.25%, respectively), and asymmetric entropy descriptors of RR intervals. Previously, both pRR30 and pRR3.25% outperformed many other heart rate variability (HRV) parameters in distinguishing AF from sinus rhythm (SR) in 60 s electrocardiograms (ECGs). METHODS: The 60 s segments with RR intervals were extracted from the publicly available Physionet Long-Term Atrial Fibrillation Database (84 recording, 24 h Holter ECG). There were 31,753 60 s segments of AF and 32,073 60 s segments of SR. The diagnostic properties of all parameters were analysed with receiver operator curve analysis, a confusion matrix and logistic regression. The best model with pRR30, pRR3.25% and total entropic features (H) had the largest area under the curve (AUC)-0.98 compared to 0.959 for pRR30-and 0.972 for pRR3.25%. However, the differences in AUC between pRR30 and pRR3.25% alone and the combined model were negligible from a practical point of view. Moreover, combining pRR30 and pRR3.25% with H significantly increased the number of false-negative cases by more than threefold. CONCLUSIONS: Asymmetric entropy has some potential in differentiating AF from SR in the 60 s RR interval time series, but the addition of these parameters does not seem to make a relevant difference compared to pRR30 and especially pRR3.25%.

2.
J Clin Med ; 12(2)2023 Jan 15.
Article in English | MEDLINE | ID: mdl-36675616

ABSTRACT

BACKGROUND: The ratio of the difference between neighboring RR intervals to the length of the preceding RR interval (x%) represents the relative change in the duration between two cardiac cycles. We investigated the diagnostic properties of the percentage of relative RR interval differences equal to or greater than x% (pRRx%) with x% in a range between 0.25% and 25% for the distinction of atrial fibrillation (AF) from sinus rhythm (SR). METHODS: We used 1-min ECG segments with RR intervals with either AF (32,141 segments) or SR (32,769 segments) from the publicly available Physionet Long-Term Atrial Fibrillation Database (LTAFDB). The properties of pRRx% for different x% were analyzed using the statistical procedures and metrics commonly used to characterize diagnostic methods. RESULTS: The distributions of pRRx% for AF and SR differ significantly over the whole studied range of x% from 0.25% to 25%, with particularly outstanding diagnostic properties for the x% range of 1.5% to 6%. However, pRR3.25% outperformed other pRRx%. Firstly, it had one of the highest and closest to perfect areas under the curve (0.971). For pRR3.25%, the optimal threshold for distinction AF from SR was set at 75.32%. Then, the accuracy was 95.44%, sensitivity was 97.16%, specificity was 93.76%, the positive predictive value was 93.85%, the negative predictive value was 97.11%, and the diagnostic odds ratio was 514. The excellent diagnostic properties of pRR3.25% were confirmed in the publicly available MIT-BIH Atrial Fibrillation Database. In a direct comparison, pRR3.25% outperformed the diagnostic properties of pRR31 (the percentage of successive RR intervals differing by at least 31 ms), i.e., so far, the best single parameter differentiating AF from SR. CONCLUSIONS: A family of pRRx% parameters has excellent diagnostic properties for AF detection in a range of x% between 1.5% and 6%. However, pRR3.25% outperforms other pRRx% parameters and pRR31 (until now, probably the most robust single heart rate variability parameter for AF diagnosis). The exquisite pRRx% diagnostic properties for AF and its simple computation make it well-suited for AF detection in modern ECG technologies (mobile/wearable devices, biopatches) in long-term monitoring. The diagnostic properties of pRRx% deserve further exploration in other databases with AF.

3.
J Clin Med ; 11(19)2022 Sep 27.
Article in English | MEDLINE | ID: mdl-36233572

ABSTRACT

BACKGROUND: We studied the diagnostic properties of the percentage of successive RR intervals differing by at least x ms (pRRx) as functions of the threshold value x in a range of 7 to 195 ms for the differentiation of atrial fibrillation (AF) from sinus rhythm (SR). METHODS: RR intervals were measured in 60-s electrocardiogram (ECG) segments with either AF (32,141 segments) or SR (32,769 segments) from the publicly available Physionet Long-Term Atrial Fibrillation Database (LTAFDB). For validation, we have used ECGs from the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) Atrial Fibrillation Database. The pRRx distributions in AF and SR in relation to x were studied by histograms, along with the mutual association by the nonparametric Spearman correlations for all pairs of pRRx, and separately for AF or SR. The optimal cutoff values for all pRRx were determined using the receiver operator curve characteristic. A nonparametric bootstrap with 5000 samples was used to calculate a 95% confidence interval for several classification metrics. RESULTS: The distributions of pRRx for x in the 7-195 ms range are significantly different in AF than in SR. The sensitivity, specificity, accuracy, and diagnostic odds ratios differ for pRRx, with the highest values for x = 31 ms (pRR31) rather than x = 50 (pRR50), which is most commonly applied in studies on heart rate variability. For the optimal cutoff of pRR31 (68.79%), the sensitivity is 90.42%, specificity 95.37%, and the diagnostic odds ratio is 194.11. Validation with the ECGs from the MIT-BIH Atrial Fibrillation Database confirmed our findings. CONCLUSIONS: We demonstrate that the diagnostic properties of pRRx depend on x, and pRR31 outperforms pRR50, at least for ECGs of 60-s duration.

4.
J Clin Med ; 11(14)2022 Jul 11.
Article in English | MEDLINE | ID: mdl-35887768

ABSTRACT

Heart rate is quite regular during sinus (normal) rhythm (SR) originating from the sinus node. In contrast, heart rate is usually irregular during atrial fibrillation (AF). Complete atrioventricular block with an escape rhythm, ventricular pacing, or ventricular tachycardia are the most common exceptions when heart rate may be regular in AF. Heart rate variability (HRV) is the variation in the duration of consecutive cardiac cycles (RR intervals). We investigated the utility of HRV parameters for automated detection of AF with machine learning (ML) classifiers. The minimum redundancy maximum relevance (MRMR) algorithm, one of the most effective algorithms for feature selection, helped select the HRV parameters (including five original), best suited for distinguishing AF from SR in a database of over 53,000 60 s separate electrocardiogram (ECG) segments cut from longer (up to 24 h) ECG recordings. HRV parameters entered the ML-based classifiers as features. Seven different, commonly used classifiers were trained with one to six HRV-based features with the highest scores resulting from the MRMR algorithm and tested using the 5-fold cross-validation and blindfold validation. The best ML classifier in the blindfold validation achieved an accuracy of 97.2% and diagnostic odds ratio of 1566. From all studied HRV features, the top three HRV parameters distinguishing AF from SR were: the percentage of successive RR intervals differing by at least 50 ms (pRR50), the ratio of standard deviations of points along and across the identity line of the Poincare plots, respectively (SD2/SD1), and coefficient of variation-standard deviation of RR intervals divided by their mean duration (CV). The proposed methodology and the presented results of the selection of HRV parameters have the potential to develop practical solutions and devices for automatic AF detection with minimal sets of simple HRV parameters. Using straightforward ML classifiers and the extremely small sets of simple HRV features, always with pRR50 included, the differentiation of AF from sinus rhythms in the 60 s ECGs is very effective.

SELECTION OF CITATIONS
SEARCH DETAIL