Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Radiother Oncol ; 188: 109906, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37690668

ABSTRACT

BACKGROUND AND PURPOSE: The impact of radiotherapy (RT) at ultra high vs conventional dose rate (FLASH vs CONV) on the generation and repair of DNA double strand breaks (DSBs) is an important question that remains to be investigated. Here, we tested the hypothesis as to whether FLASH-RT generates decreased chromosomal translocations compared to CONV-RT. MATERIALS AND METHODS: We used two FLASH validated electron beams and high-throughput rejoin and genome-wide translocation sequencing (HTGTS-JoinT-seq), employing S. aureus and S. pyogenes Cas9 "bait" DNA double strand breaks (DSBs) in HEK239T cells, to measure differences in bait-proximal repair and their genome-wide translocations to "prey" DSBs generated after various irradiation doses, dose rates and oxygen tensions (normoxic, 21% O2; physiological, 4% O2; hypoxic, 2% and 0.5% O2). Electron irradiation was delivered using a FLASH capable Varian Trilogy and the eRT6/Oriatron at CONV (0.08-0.13 Gy/s) and FLASH (1x102-5x106 Gy/s) dose rates. Related experiments using clonogenic survival and γH2AX foci in the 293T and the U87 glioblastoma lines were also performed to discern FLASH-RT vs CONV-RT DSB effects. RESULTS: Normoxic and physioxic irradiation of HEK293T cells increased translocations at the cost of decreasing bait-proximal repair but were indistinguishable between CONV-RT and FLASH-RT. Although no apparent increase in chromosome translocations was observed with hypoxia-induced apoptosis, the combined decrease in oxygen tension with IR dose-rate modulation did not reveal significant differences in the level of translocations nor in their junction structures. Furthermore, RT dose rate modality on U87 cells did not change γH2AX foci numbers at 1- and 24-hours post-irradiation nor did this affect 293T clonogenic survival. CONCLUSION: Irrespective of oxygen tension, FLASH-RT produces translocations and junction structures at levels and proportions that are indistinguishable from CONV-RT.

2.
bioRxiv ; 2023 Mar 27.
Article in English | MEDLINE | ID: mdl-37034651

ABSTRACT

The molecular and cellular mechanisms driving the enhanced therapeutic ratio of ultra-high dose-rate radiotherapy (FLASH-RT) over slower conventional (CONV-RT) radiotherapy dose-rate remain to be elucidated. However, attenuated DNA damage and transient oxygen depletion are among several proposed models. Here, we tested whether FLASH-RT under physioxic (4% O 2 ) and hypoxic conditions (≤2% O 2 ) reduces genome-wide translocations relative to CONV-RT and whether any differences identified revert under normoxic (21% O 2 ) conditions. We employed high-throughput rejoin and genome-wide translocation sequencing ( HTGTS-JoinT-seq ), using S. aureus and S. pyogenes Cas9 "bait" DNA double strand breaks (DSBs), to measure differences in bait-proximal repair and their genome-wide translocations to "prey" DSBs generated by electron beam CONV-RT (0.08-0.13Gy/s) and FLASH-RT (1×10 2 -5×10 6 Gy/s), under varying ionizing radiation (IR) doses and oxygen tensions. Normoxic and physioxic irradiation of HEK293T cells increased translocations at the cost of decreasing bait-proximal repair but were indistinguishable between CONV-RT and FLASH-RT. Although no apparent increase in chromosome translocations was observed with hypoxia-induced apoptosis, the combined decrease in oxygen tension with IR dose-rate modulation did not reveal significant differences in the level of translocations nor in their junction structures. Thus, Irrespective of oxygen tension, FLASH-RT produces translocations and junction structures at levels and proportions that are indistinguishable from CONV-RT.

3.
Int J Radiat Oncol Biol Phys ; 117(1): 96-104, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37001762

ABSTRACT

PURPOSE: The Audio-Visual Assisted Therapeutic Ambience in Radiotherapy (AVATAR) system was the first published radiation therapy (RT)-compatible system to reduce the need for pediatric anesthesia through video-based distraction. We evaluated the feasibility of AVATAR implementation and effects on anesthesia use, quality of life, and anxiety in a multicenter pediatric trial. METHODS AND MATERIALS: Pediatric patients 3 to 10 years of age preparing to undergo RT at 10 institutions were prospectively enrolled. Children able to undergo at least 1 fraction of RT using AVATAR without anesthesia were considered successful (S). Patients requiring anesthesia for their entire treatment course were nonsuccessful (NS). The PedsQL3.0 Cancer Module (PedsQL) survey assessed quality of life and was administered to the patient and guardian at RT simulation, midway through RT, and at final treatment. The modified Yale Preoperative Anxiety Scale (mYPAS) assessed anxiety and was performed at the same 3 time points. Success was evaluated using the χ2 test. PedsQL and mYPAS scores were assessed using mixed effects models with time points evaluated as fixed effects and a random intercept on the subject. RESULTS: Eighty-one children were included; median age was 7 years. AVATAR was successful at all 10 institutions and with photon and proton RT. There were 63 (78%) S patients; anesthesia was avoided for a median of 20 fractions per patient. Success differed by age (P = .04) and private versus public insurance (P < .001). Both patient (P = .008) and parent (P = .006) PedsQL scores significantly improved over the course of RT for patients aged 5 to 7. Anxiety in the treatment room decreased for both S and NS patients over RT course (P < .001), by age (P < .001), and by S versus NS patients (P < .001). CONCLUSIONS: In this 10-center prospective trial, anesthesia avoidance with AVATAR was 78% in children aged 3 to 10 years, higher than among age-matched historical controls (49%; P < .001). AVATAR implementation is feasible across multiple institutions and should be further studied and made available to patients who may benefit from video-based distraction.


Subject(s)
Anesthesia , Radiation Oncology , Humans , Child , Child, Preschool , Feasibility Studies , Prospective Studies , Quality of Life
4.
Radiother Oncol ; 175: 203-209, 2022 10.
Article in English | MEDLINE | ID: mdl-36030934

ABSTRACT

BACKGROUND AND PURPOSE: We describe a multicenter cross validation of ultra-high dose rate (UHDR) (>= 40 Gy/s) irradiation in order to bring a dosimetric consensus in absorbed dose to water. UHDR refers to dose rates over 100-1000 times those of conventional clinical beams. UHDR irradiations have been a topic of intense investigation as they have been reported to induce the FLASH effect in which normal tissues exhibit reduced toxicity relative to conventional dose rates. The need to establish optimal beam parameters capable of achieving the in vivo FLASH effect has become paramount. It is therefore necessary to validate and replicate dosimetry across multiple sites conducting UHDR studies with distinct beam configurations and experimental set-ups. MATERIALS AND METHODS: Using a custom cuboid phantom with a cylindrical cavity (5 mm diameter by 10.4 mm length) designed to contain three type of dosimeters (thermoluminescent dosimeters (TLDs), alanine pellets, and Gafchromic films), irradiations were conducted at expected doses of 7.5 to 16 Gy delivered at UHDR or conventional dose rates using various electron beams at the Radiation Oncology Departments of the CHUV in Lausanne, Switzerland and Stanford University, CA. RESULTS: Data obtained between replicate experiments for all dosimeters were in excellent agreement (±3%). In general, films and TLDs were in closer agreement with each other, while alanine provided the closest match between the expected and measured dose, with certain caveats related to absolute reference dose. CONCLUSION: In conclusion, successful cross-validation of different electron beams operating under different energies and configurations lays the foundation for establishing dosimetric consensus for UHDR irradiation studies, and, if widely implemented, decrease uncertainty between different sites investigating the mechanistic basis of the FLASH effect.


Subject(s)
Electrons , Radiometry , Humans , Phantoms, Imaging , Water , Alanine
5.
Int J Radiat Oncol Biol Phys ; 112(5): 1144-1153, 2022 04 01.
Article in English | MEDLINE | ID: mdl-34942312

ABSTRACT

PURPOSE: Our purpose was to evaluate the incidence of acute and late esophageal toxicity in patients with thoracic tumors near or abutting the esophagus treated with SABR. METHODS AND MATERIALS: Among patients with thoracic tumors treated with SABR, we identified those with tumors near or abutting the esophagus. Using the linear-quadratic model with an α/ß ratio of 10, we determined the correlation between dosimetric parameters and esophageal toxicity graded using the Common Terminology Criteria for Adverse Events, version 5.0. RESULTS: Out of 2200 patients treated with thoracic SABR, 767 patients were analyzable for esophageal dosimetry. We identified 55 patients with tumors near the esophagus (52 evaluable for esophagitis grade) and 28 with planning target volume (PTV) overlapping the esophagus. Dose gradients across the esophagus were consistently sharp. Median follow-up and overall survival were 16 and 23 months, respectively. Thirteen patients (25%) developed temporary grade 2 acute esophageal toxicity, 11 (85%) of whom had PTV overlapping the esophagus. Symptoms resolved within 1 to 3 months in 12 patients and 6 months in all patients. No grade 3 to 5 toxicity was observed. Only 3 patients (6%) developed late or persistent grade 2 dysphagia or dyspepsia of uncertain relationship to SABR. The cumulative incidence of acute esophagitis was 15% and 25% at 14 and 60 days, respectively. Acute toxicity correlated on univariate analysis with esophageal Dmax, D1cc, D2cc, Dmax/Dprescription, and whether the PTV was overlapping the esophagus. Esophageal Dmax (BED10) <62 Gy, D1cc (BED10) <48 Gy, D2cc (BED10) <43 Gy, and Dmax/Dprescription <85% were associated with <20% risk of grade 2 acute esophagitis. Only 2 local recurrences occurred. CONCLUSIONS: Although 25% of patients with tumors near the esophagus developed acute esophagitis (39% of those with PTV overlapping the esophagus), these toxicities were all grade 2 and all temporary. This suggests the safety and efficacy of thoracic SABR for tumors near or abutting the esophagus when treating with high conformity and sharp dose gradients.


Subject(s)
Esophagitis , Lung Neoplasms , Radiosurgery , Thoracic Neoplasms , Esophagitis/etiology , Humans , Lung Neoplasms/pathology , Radiosurgery/methods , Radiotherapy Dosage , Thoracic Neoplasms/complications
6.
Med Phys ; 48(11): 7450-7460, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34628666

ABSTRACT

PURPOSE: The RefleXion™ X1 is a novel radiotherapy system that is designed for image-guided radiotherapy, and eventually, biology-guided radiotherapy (BgRT). BgRT is a treatment paradigm that tracks tumor motion using real-time positron emission signals. This study reports the small-field measurement results and the validation of a Monte Carlo (MC) model of the first clinical RefleXion unit. METHODS: The RefleXion linear accelerator (linac) produces a 6 MV flattening filter free (FFF) photon beam and consists of a binary multileaf collimator (MLC) system with 64 leaves and two pairs of y-jaws. The maximum clinical field size achievable is 400 × 20 mm2 . The y-jaws provide either a 10 or 20 mm opening at source-to-axis distance (SAD) of 850 mm. The width of each MLC leaf at SAD is 6.25 mm. Percentage depth doses (PDDs) and relative beam profiles were acquired using an Edge diode detector in a water tank for field sizes from 12.5 × 10 to 100 × 20 mm2 . Beam profiles were also measured using films. Output factors of fields ranging from 6.25 × 10 to 100 × 20 mm2 were measured using W2 scintillator detector, Edge detector, and films. Output correction factors k of the Edge detector for RefleXion were calculated. An MC model of the linac including pre-MLC beam sources and detailed structures of MLC and lower y-jaws was validated against the measurements. Simulation codes BEAMnrc and GATE were utilized. RESULTS: The diode measured PDD at 10 cm depth (PDD10) increases from 53.6% to 56.9% as the field opens from 12.5 × 10 to 100 × 20 mm2 . The W2-measured output factor increases from 0.706 to 1 as the field opens from 6.25 × 10 to 100 × 20 mm2 (reference field size). The output factors acquired by diode and film differ from the W2 results by 1.65% (std = 1.49%) and 2.09% (std = 1.41%) on average, respectively. The profile penumbra and full-width half-maximum (FWHM) measured by diode agree well with the film results with a deviation of 0.60 mm and 0.73% on average, respectively. The averaged beam profile consistency calculated between the diode- and film-measured profiles among different depths is within 1.72%. By taking the W2 measurements as the ground truth, the output correction factors k for Edge detector ranging from 0.958 to 1 were reported. For the MC model validation, the simulated PDD10 agreed within 0.6% to the diode measurement. The MC-simulated output factor differed from the W2 results by 2.3% on average (std = 3.7%), while the MC simulated beam penumbra differed from the diode results by 0.67 mm on average (std = 0.42 mm). The MC FWHM agreed with the diode results to within 1.40% on average. The averaged beam profile consistency calculated between the diode and MC profiles among different depths is less than 1.29%. CONCLUSIONS: This study represents the first small-field dosimetry of a clinical RefleXion system. A complete and accurate MC model of the RefleXion linac has been validated.


Subject(s)
Radiotherapy, Image-Guided , Monte Carlo Method , Particle Accelerators , Radiometry , Radiotherapy Planning, Computer-Assisted
7.
Am J Clin Oncol ; 44(11): 559-564, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34534143

ABSTRACT

PURPOSE: The aim of this study was to report local failure (LF) outcomes and associated predictors in patients with oligometastatic colorectal cancer (CRC) treated with stereotactic ablative radiotherapy (SABR). MATERIALS AND METHODS: We retrospectively reviewed patients with CRC metastases to the brain, liver, spine, or lung treated with SABR between 2001 and 2016. Time to LF was summarized using cumulative incidence of LF curves with death as a competing risk. RESULTS: The analysis included a total of 130 patients and 256 lesions. Of the metastases treated, 129 (50%) were brain, 50 (20%) liver, 49 (19%) spine, and 28 (11%) lung. Median gross tumor volume was 24 mL for liver metastases, 2 mL for brain metastases, 4 mL for spine metastases, and 1 mL for lung metastases. The overall 1, 2, and 3-year cumulative incidence of LF rates were 21.6% (16.5, 27.1), 28.2% (22.3, 34.4), and 31.5% (25.2, 38.0), respectively. LF was highest among the liver metastases (1 y: 26.0%, 2 y: 38.5%), followed by spine (1 y: 25.1%, 2 y: 31.1%), brain (1 y: 20%, 2 y: 25.2%), and lung (1 y: 13.7%, 2 y: insufficient data). Metastases from right-sided primary CRC were significantly more likely to have LF (P=0.0146, HR=2.23). Biologically effective dose>70 Gy, defined using a standard linear quadratic model using α/ß ratio of 10 on the individual lesion level, and pre-SABR chemotherapy were also significant predictors of LF (P= 0.0009 and 0.018, respectively). CONCLUSIONS: CRC metastases treated with SABR had significantly higher rates of LF if they originated from right-sided primary CRC, compared with left-sided. Liver metastases had the highest rates of LF compared with other metastatic sites. Thus, CRC liver metastases and metastases from right-sided CRC may benefit from more aggressive radiotherapy.


Subject(s)
Colorectal Neoplasms/pathology , Colorectal Neoplasms/radiotherapy , Metastasectomy/methods , Neoplasm Recurrence, Local/radiotherapy , Radiosurgery , Ablation Techniques , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Neoplasm Metastasis , Radiosurgery/methods , Retrospective Studies
8.
J Appl Clin Med Phys ; 22(7): 128-136, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34042253

ABSTRACT

PURPOSE: Electron radiation therapy dose distributions are affected by irregular body surface contours. This study investigates the feasibility of three-dimensional (3D) cameras to substitute for the treatment planning computerized tomography (CT) scan by capturing the body surfaces to be treated for accurate electron beam dosimetry. METHODS: Dosimetry was compared for six electron beam treatments to the nose, toe, eye, and scalp using full CT scan, CT scan with Hounsfield Unit (HU) overridden to water (mimic 3D camera cases), and flat-phantom techniques. Radiation dose was prescribed to a depth on the central axis per physician's order, and the monitor units (MUs) were calculated. The 3D camera spatial accuracy was evaluated by comparing the 3D surface of a head phantom captured by a 3D camera and that generated with the CT scan in the treatment planning system. A clinical case is presented, and MUs were calculated using the 3D camera body contour with HU overridden to water. RESULTS: Across six cases the average change in MUs between the full CT and the 3Dwater (CT scan with HU overridden to water) calculations was 1.3% with a standard deviation of 1.0%. The corresponding hotspots had a mean difference of 0.4% and a standard deviation of 1.9%. The 3D camera captured surface of a head phantom was found to have a 0.59 mm standard deviation from the surface derived from the CT scan. In-vivo dose measurements (213 ± 8 cGy) agreed with the 3D-camera planned dose of 209 ± 6 cGy, compared to 192 ± 6 cGy for the flat-phantom calculation (same MUs). CONCLUSIONS: Electron beam dosimetry is affected by irregular body surfaces. 3D cameras can capture irregular body contours which allow accurate dosimetry of electron beam treatment as an alternative to costly CT scans with no extra exposure to radiation. Tools and workflow for clinical implementation are provided.


Subject(s)
Electrons , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
10.
Phys Med Biol ; 66(7)2021 04 06.
Article in English | MEDLINE | ID: mdl-33657537

ABSTRACT

Purpose. Radiation dose delivered to targets located near the upper-abdomen or in the thorax are significantly affected by respiratory-motion. Relatively large-margins are commonly added to compensate for this motion, limiting radiation-dose-escalation. Internal-surrogates of target motion, such as a radiofrequency (RF) tracking system, i.e. Calypso®System, are used to overcome this challenge and improve normal-tissue sparing. RF tracking systems consist of implanting transponders in the vicinity of the tumor to be tracked using radiofrequency-waves. Unfortunately, although the manufacture provides a universal quality-assurance (QA) phantom, QA-phantoms specifically for lung-applications are limited, warranting the development of alternative solutions to fulfil the tests mandated by AAPM's TG142. Accordingly, our objective was to design and develop a motion-phantom to evaluate Calypso for lung-applications that allows the Calypso®Beacons to move in different directions to better simulate truelung-motion.Methods and Materials.A Calypso lung QA-phantom was designed, and 3D-printed. The design consists of three independent arms where the transponders were attached. A pinpoint-chamber with a buildup-cap was also incorporated. A 4-axis robotic arm was programmed to drive the motion-phantom to mimic breathing. After acquiring a four-dimensional-computed-tomography (4DCT) scan of the motion-phantom, treatment-plans were generated and delivered on a Varian TrueBeam®with Calypso capabilities. Stationary and gated-treatment plans were generated and delivered to determine the dosimetric difference between gated and non-gated treatments. Portal cine-images were acquired to determine the temporal-accuracy of delivery by calculating the difference between the observed versus expected transponders locations with the known speed of the transponders' motion.Results.Dosimetric accuracy is better than the TG142 tolerance of 2%. Temporal accuracy is greater than, TG142 tolerance of 100 ms for beam-on, but less than 100 ms for beam-hold.Conclusions.The robotic QA-phantom designed and developed in this study provides an independent phantom for performing Calypso lung-QA for commissioning and acceptance testing of Calypso for lung treatments.


Subject(s)
Robotic Surgical Procedures , Humans , Lung/diagnostic imaging , Neonicotinoids , Phantoms, Imaging , Printing, Three-Dimensional , Thiazines
11.
Med Phys ; 48(1): 366-375, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33107049

ABSTRACT

PURPOSE: The dosimetric properties of inverse Compton (IC) x-ray sources were investigated to determine their utility for stereotactic radiation therapy. METHODS: Monte Carlo simulations were performed using the egs brachy user code of EGSnrc. Nominal IC source x-ray energies of 80 and 150 keV were considered in this work. Depth-dose and lateral dose profiles in water were calculated, as was dose enhancement in the bone. Further simulations were performed for brain and spine treatment sites. The impact of gold nanoparticle doping was also investigated for the brain treatment site. Analogous dose calculations were performed in a clinical treatment planning system using a clinical 6 MV photon beam model and were compared to the Monte Carlo simulations. RESULTS: Both 80 and 150 keV IC beams were observed to have sharp 80-20 penumbra (i.e., < 0.1 mm) with broad low-dose tails in water. For reference, the calculated penumbra for the 6 MV clinical beam was 3 mm. Maximum dose enhancement factors in bone of 3.1, 1.4, and 1.1 were observed for the 80, 150 keV, and clinical 6 MV beams, respectively. The plan quality for the single brain metastasis case was similar between the IC beams and the 6 MV beam without gold nanoparticles. As the concentration of gold within the target increased, the V12 Gy to the normal brain tissue and D max within the target volume significantly decreased and the conformity significantly improved, which resulted in superior plan quality over the clinical 6 MV beam plan. In the spine cases, the sharp penumbra and enhanced dose to bone of the IC beams produced superior plan quality (i.e., better conformity, normal tissue sparing, and spinal cord sparing) as compared to the clinical 6 MV beam plans. CONCLUSIONS: The findings from this work indicate that inverse Compton x-ray sources are well suited for stereotactic radiotherapy treatments due to their sharp penumbra and dose enhancement around high atomic number materials. Future work includes investigating the properties of intensity-modulated inverse Compton x-ray sources to improve the homogeneity within the target tissue.


Subject(s)
Metal Nanoparticles , Radiosurgery , Gold , Monte Carlo Method , Radiotherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , X-Rays
12.
Sci Rep ; 10(1): 21600, 2020 12 10.
Article in English | MEDLINE | ID: mdl-33303827

ABSTRACT

Radiation therapy is the most effective cytotoxic therapy for localized tumors. However, normal tissue toxicity limits the radiation dose and the curative potential of radiation therapy when treating larger target volumes. In particular, the highly radiosensitive intestine limits the use of radiation for patients with intra-abdominal tumors. In metastatic ovarian cancer, total abdominal irradiation (TAI) was used as an effective postsurgical adjuvant therapy in the management of abdominal metastases. However, TAI fell out of favor due to high toxicity of the intestine. Here we utilized an innovative preclinical irradiation platform to compare the safety and efficacy of TAI ultra-high dose rate FLASH irradiation to conventional dose rate (CONV) irradiation in mice. We demonstrate that single high dose TAI-FLASH produced less mortality from gastrointestinal syndrome, spared gut function and epithelial integrity, and spared cell death in crypt base columnar cells compared to TAI-CONV irradiation. Importantly, TAI-FLASH and TAI-CONV irradiation had similar efficacy in reducing tumor burden while improving intestinal function in a preclinical model of ovarian cancer metastasis. These findings suggest that FLASH irradiation may be an effective strategy to enhance the therapeutic index of abdominal radiotherapy, with potential application to metastatic ovarian cancer.


Subject(s)
Gastrointestinal Tract/radiation effects , Ovarian Neoplasms/radiotherapy , Radiation Injuries, Experimental/prevention & control , Radiotherapy/methods , Animals , Female , Gastrointestinal Tract/injuries , Gastrointestinal Tract/pathology , Mice , Mice, Inbred C57BL , Radiotherapy/adverse effects
13.
Radiat Res ; 194(6): 594-599, 2020 12 01.
Article in English | MEDLINE | ID: mdl-32991725

ABSTRACT

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.


Subject(s)
Brain/radiation effects , Electrons , Radiotherapy Dosage , Radiotherapy/methods , Child , Feasibility Studies , Humans , Monte Carlo Method , Software
14.
Radiat Res ; 194(6): 618-624, 2020 12 01.
Article in English | MEDLINE | ID: mdl-32853385

ABSTRACT

Radiation therapy, along with surgery and chemotherapy, is one of the main treatments for cancer. While radiotherapy is highly effective in the treatment of localized tumors, its main limitation is its toxicity to normal tissue. Previous preclinical studies have reported that ultra-high dose-rate (FLASH) irradiation results in reduced toxicity to normal tissues while controlling tumor growth to a similar extent relative to conventional-dose-rate (CONV) irradiation. To our knowledge this is the first report of a dose-response study in mice comparing the effect of FLASH irradiation vs. CONV irradiation on skin toxicity. We found that FLASH irradiation results in both a lower incidence and lower severity of skin ulceration than CONV irradiation 8 weeks after single-fraction hemithoracic irradiation at high doses (30 and 40 Gy). Survival was also higher after FLASH hemithoracic irradiation (median survival >180 days at doses of 30 and 40 Gy) compared to CONV irradiation (median survival 100 and 52 days at 30 and 40 Gy, respectively). No ulceration was observed at doses 20 Gy or below in either FLASH or CONV. These results suggest a shifting of the dose-response curve for radiation-induced skin ulceration to the right for FLASH, compared to CONV irradiation, suggesting the potential for an enhanced therapeutic index for radiation therapy of cancer.


Subject(s)
Radiotherapy/methods , Skin/radiation effects , Animals , Dose-Response Relationship, Radiation , Female , Mice , Mice, Inbred C57BL , Radiation Injuries, Experimental/mortality , Radiation Injuries, Experimental/physiopathology , Radiation Injuries, Experimental/prevention & control , Radiotherapy/adverse effects , Severity of Illness Index
15.
Pract Radiat Oncol ; 10(4): e272-e279, 2020.
Article in English | MEDLINE | ID: mdl-31935524

ABSTRACT

PURPOSE: Pediatric radiation therapy (RT) requires optimal immobilization that often necessitates daily anesthesia. To decrease anesthesia use, we implemented a novel audiovisual-assisted therapeutic ambience in RT (AVATAR) system that projects video onto a radiolucent screen within the child's line of vision to provide attentional diversion. We investigated its reduction on anesthesia use, payer charges, and treatment time, in addition to its impact on radiation delivery. METHODS AND MATERIALS: A 6-year retrospective analysis was performed among children undergoing RT (n = 224) 3 years before and 3 years after the introduction of AVATAR. The frequency of anesthesia use before and after AVATAR implementation, in addition to RT treatment times, were compared. The number of spared anesthesia treatments allowed for a charge to payer analysis. To document the lack of surface dose perturbation by AVATAR, a phantom craniospinal treatment course was delivered both with and without AVATAR. Additionally, an ion chamber course was delivered to document changes to the dose at depth. RESULTS: More children were able to avoid anesthesia use entirely in the post-AVATAR cohort compared with the pre-AVATAR cohort (73.2% vs 63.4%; P = .03), and fewer required anesthesia for each treatment (18.8% vs 33%; P = .03). AVATAR introduction reduced anesthesia use for all ages studied. Treatment time per session was reduced by 38% using AVATAR compared with anesthesia. There were 326 fewer anesthesia sessions delivered over 3 years after AVATAR was introduced, with an estimated savings of >$500,000. Optically stimulated luminescent dosimeters revealed a small increase in dose of 0.8% to 9.5% with AVATAR, whereas the use of a thermomolded face mask increased skin dose by as much as 58%. CONCLUSIONS: AVATAR introduction decreased anesthesia use in children undergoing RT. More children avoided anesthesia entirely, and fewer needed anesthesia for every treatment, resulting in a reduction in treatment time and savings of nearly $550,000 in approximately 3 years, with minimal perturbation of RT dose delivery.


Subject(s)
Anesthesia/methods , Audiovisual Aids/standards , Radiotherapy/economics , Radiotherapy/methods , Child , Child, Preschool , Female , Humans , Male , Retrospective Studies
16.
Pract Radiat Oncol ; 10(2): e91-e94, 2020.
Article in English | MEDLINE | ID: mdl-31574319

ABSTRACT

PURPOSE: Because children cannot reliably remain immobile during radiation therapy (RT) for cancer anatomy targeting requiring millimeter precision, daily anesthesia plays a large role in each RT session. Unfortunately, anesthesia is a source of financial burden for patients' families and is invasive and traumatic. This study attempts to assess the cost-savings benefit of audiovisual-assisted therapeutic ambiance in radiation therapy (AVATAR)-aided omission of pediatric anesthesia in RT. METHODS AND MATERIALS: The baseline time of anesthesia during RT was derived from documented anesthesia billing time during RT simulation at our institution and from the published literature. Current Procedural Terminology and relative value unit codes encompassing anesthesia-related charges from radiation oncology and anesthesia were analyzed in concert with this value to calculate the total cost of pediatric anesthesia per RT session. RESULTS: The mean number of RT fractions administered per patient with AVATAR-directed anesthesia omission at our institution was 19.0, similar to the 17.6 previously reported. At a mean anesthesia time exceeding 30 minutes (with mean RT duration of 4 weeks), the cost of pediatric anesthesia per RT fraction in non-AVATAR sessions was $1,904.35, yielding a total RT treatment anesthesia cost of $38,087.00 per patient (including simulation). Patients at our institution were not billed for AVATAR-assisted RT. CONCLUSIONS: The ability of AVATAR to obviate the need for daily anesthesia in pediatric RT provides substantial cost-savings. These findings argue for increased utilization of AVATAR and for analyses of RT targeting the accuracy of AVATAR versus conventional anesthesia-guided treatment of pediatric malignancies.


Subject(s)
Audiovisual Aids/standards , Health Care Costs/standards , Neoplasms/economics , Neoplasms/radiotherapy , Child , Child, Preschool , Female , Humans , Male
17.
J Appl Clin Med Phys ; 20(8): 56-64, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31423729

ABSTRACT

PURPOSE: To develop and implement an automated plan check (APC) tool using a Six Sigma methodology with the aim of improving safety and efficiency in external beam radiotherapy. METHODS: The Six Sigma define-measure-analyze-improve-control (DMAIC) framework was used by measuring defects stemming from treatment planning that were reported to the departmental incidence learning system (ILS). The common error pathways observed in the reported data were combined with our departmental physics plan check list, and AAPM TG-275 identified items. Prioritized by risk priority number (RPN) and severity values, the check items were added to the APC tool developed using Varian Eclipse Scripting Application Programming Interface (ESAPI). At 9 months post-APC implementation, the tool encompassed 89 check items, and its effectiveness was evaluated by comparing RPN values and rates of reported errors. To test the efficiency gains, physics plan check time and reported error rate were prospectively compared for 20 treatment plans. RESULTS: The APC tool was successfully implemented for external beam plan checking. FMEA RPN ranking re-evaluation at 9 months post-APC demonstrated a statistically significant average decrease in RPN values from 129.2 to 83.7 (P < .05). After the introduction of APC, the average frequency of reported treatment-planning errors was reduced from 16.1% to 4.1%. For high-severity errors, the reduction was 82.7% for prescription/plan mismatches and 84.4% for incorrect shift note. The process shifted from 4σ to 5σ quality for isocenter-shift errors. The efficiency study showed a statistically significant decrease in plan check time (10.1 ± 7.3 min, P = .005) and decrease in errors propagating to physics plan check (80%). CONCLUSIONS: Incorporation of APC tool has significantly reduced the error rate. The DMAIC framework can provide an iterative and robust workflow to improve the efficiency and quality of treatment planning procedure enabling a safer radiotherapy process.


Subject(s)
Automation , Neoplasms/radiotherapy , Quality Assurance, Health Care/standards , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/standards , Software , Checklist , Humans , Organs at Risk/radiation effects , Prospective Studies , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Total Quality Management
18.
Adv Radiat Oncol ; 3(3): 297-304, 2018.
Article in English | MEDLINE | ID: mdl-30202799

ABSTRACT

PURPOSE: The purpose of this study was to determine the impact of splenic and thoracic bone marrow irradiation on hematologic toxicity in the setting of chemoradiation therapy for esophageal cancer. METHODS AND MATERIALS: We analyzed 60 patients with carcinoma of the distal esophagus or gastroesophageal junction who received concurrent chemoradiation in the preoperative or definitive setting. Dosimetric and volumetric parameters were calculated for the spleen, thoracic spine, and posterior ribs. The primary endpoint was grade ≥3 hematologic toxicity (HT3+). Associations were assessed using logistic and linear regression models. RESULTS: Twenty-one patients (35%) experienced HT3+, including 18 patients with leukopenia and 5 with thrombocytopenia. Higher spleen V5-V20 was correlated with a lower risk of HT3+ on multivariable analysis (odds ratio: 0.83 per 10 cm3 increase in V10; P = .013). A dose-dependent decrease in spleen volume was observed after radiation therapy, and a greater decrease was independently associated with a lower risk of HT3+ (odds ratio: 0.93 per 1% volume decrease; P = .014). Dosimetric parameters of the thoracic spine were not significantly associated with HT3+. CONCLUSIONS: A greater decrease in spleen size after radiation therapy and a higher spleen V5-V20 were independently associated with a lower risk of severe hematologic toxicity. Splenic irradiation may mitigate leukopenia associated with chemoradiation therapy.

20.
J Neurooncol ; 133(2): 429-434, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28534154

ABSTRACT

Medulloblastoma patients are treated with surgery, radiation and chemotherapy. Radiation dose to the temporal lobe may be associated with neurocognitive sequelae. Longitudinal changes of temporal lobe cortical thickness may result from neurodevelopmental processes such as synaptic pruning. This study applies longitudinal image analysis to compare developmental change in cortical thickness in medulloblastoma (MB) patients who were treated by combined modality therapy to that of cerebellar juvenile pilocytic astrocytoma (JPA) patients who were treated by surgery alone. We hypothesized that the rates of developmental change in cortical thickness would differ between these two groups. This retrospective cohort study assessed changes in cortical thickness over time between MB and JPA patients. High-resolution magnetic resonance (MR) images of 14 MB and 7 JPA subjects were processed to measure cortical thickness of bilateral temporal lobe substructures. A linear mixed effects model was used to identify differences in substructure longitudinal changes in cortical thickness. The left temporal lobe exhibited overall increased cortical thickness in MB patients relative to JPA patients who showed overall cortical thinning (mean annual cortical thickness change: MB 0.14 mm/year versus JPA -0.018 mm/year across all substructures), particularly in the inferior temporal lobe substructures (p < 0.0001). The cortical thickness change of the right temporal lobe substructures exhibited similar, though attenuated trends (p = 0.002). MB patients exhibit overall increased cortical thickness rather than cortical thinning as seen in JPA patients and as expected in normal cortical development. These observations are possibly due to chemoradiation induced-disruption of normal neuronal mechanisms. Longitudinal image analysis may identify early biomarkers for neurocognitive function with routine imaging.


Subject(s)
Brain Neoplasms/radiotherapy , Cerebral Cortex/growth & development , Cerebral Cortex/pathology , Chemoradiotherapy/adverse effects , Medulloblastoma/radiotherapy , Radiation Injuries/pathology , Adolescent , Brain Neoplasms/pathology , Child , Child, Preschool , Female , Functional Laterality , Humans , Infant , Longitudinal Studies , Magnetic Resonance Imaging , Male , Medulloblastoma/pathology , Retrospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...