Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 100
Filter
1.
ACS Appl Nano Mater ; 7(6): 5956-5966, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38544505

ABSTRACT

Constant exposure to blue light emanating from screens, lamps, digital devices, or other artificial sources at night can suppress melatonin secretion, potentially compromising both sleep quality and overall health. Daytime exposure to elevated levels of blue light can also lead to permanent damage to the eyes. Here, we have developed blue light protective plasmonic contact lenses (PCLs) to mitigate blue light exposure. Crafted from poly(hydroxyethyl methacrylate) (pHEMA) and infused with silver nanoparticles, these contact lenses serve as a protective barrier to filter blue light. Leveraging the plasmonic properties of silver nanoparticles, the lenses effectively filtered out the undesirable blue light (400-510 nm), demonstrating substantial protection (22-71%) while maintaining high transparency (80-96%) for the desirable light (511-780 nm). The maximum protection level reaches a peak of 79% at 455 nm, aligned with the emission peak for the blue light sourced from LEDs in consumer displays. The presence of silver nanoparticles was found to have an insignificant impact on the water content of the developed contact lenses. The lenses maintained high water retention levels within the range of 50-70 wt %, comparable to commercial contact lenses. The optical performance of the developed lenses remains unaffected in both artificial tears and contact lens storage solution over a month with no detected leakage of the nanoparticles. Additionally, the MTT assay confirmed that the lenses were biocompatible and noncytotoxic, maintaining cell viability at over 85% after 24 h of incubation. These lenses could be a potential solution to protect against the most intense wavelengths emitted by consumer displays and offer a remedy to counteract the deleterious effects of prolonged blue light exposure.

2.
Cureus ; 15(10): e47251, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38021811

ABSTRACT

Alzheimer's disease (AD) is a neurodegenerative disease primarily affecting individuals aged 65 or above. AD leads to progressive cognitive and functional decline, affecting daily life activities. Amyloid plaques are the pathological hallmark of AD, resulting in the loss of neurons and their connections in the brain. For years, patients with AD were treated with pharmacotherapies having only symptomatic effects. Till 2023, no drug was approved for disease-modifying potential. The Food and Drug Administration approved Lecanemab and aducanumab as the first therapy with disease-modifying effects in 2023. Lecanemab has shown efficacy in several trials, with the potential to improve cognition in AD patients. In this article, we will discuss the treatment options for AD, emphasizing the newly approved monoclonal antibodies and their prospects.

3.
Light Sci Appl ; 12(1): 271, 2023 Nov 13.
Article in English | MEDLINE | ID: mdl-37957141

ABSTRACT

Smart contact lenses have recently gained traction due to their functionalization as noninvasive diagnostic and therapeutic wearables that can address several ocular diseases. Herein, multifunctional contact lenses exhibiting UV-transition and temperature-responsive capabilities were developed utilizing chromogenic materials that were integrated simultaneously into poly(2-hydroxyethyl methacrylate) (pHEMA) contact lenses. The functionalities of the contact lenses were optically evaluated in both their activated and non-activated states. Transition contact lenses offered excellent UV and blue light blocking capabilities (~45%) at their inactive states. When activated via UV exposure, the transparent lenses darkened instantaneously and absorbed portions of the visible light spectrum. The absorption intensity and transient discoloration of the transition lenses relied primarily on the utilized photochromic material. Likewise, the temperature-responsive contact lenses exhibited distinct colorimetric variations in response to temperature changes within the physiological range (33-38 °C). The maximum sensitivity of the thermochromic lens was 8% transmitted light per Celsius degree shift. Physiochemical and morphological analysis indicated the adequacy of the contact lenses. Hence, the multifunctional contact lenses can be deployed as smart wearables to manage ophthalmic deficiencies that are deterred by UV radiations and variations in ocular surface temperature.

4.
Micromachines (Basel) ; 14(10)2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37893392

ABSTRACT

The skin has emerge as a compelling subject for investigation owing to its accessibility and the relatively straightforward application of optical procedures to it. Diffusive reflection spectroscopy (DRS) was employed to study the influence of probe pressure on human skin. A comprehensive non-invasive study was conducted, which covers almost all the important body parts for in vivo measurements. Reflection spectra were measured for the fingertip, forearm, forehead, neck, and foot under a set of probe pressures (0-265 kPa). Importantly, each tissue type's unique composition and morphology influenced the shape, size, intensity, and position of the recorded peak, highlighting the tissue-specific responses to pressure. In addition, time-based reflection spectroscopy was also performed on the forearm under blood occlusion for 5 min to study the effect. DRS measurements were performed on volunteers of different skin tones, including dark, medium, and fair. Later, a change in the intensity of the oxyhemoglobin peak was confirmed using a green laser light of a wavelength of 532 nm. Besides the dermal studies, diffusive reflection spectroscopy was also employed to investigate the probe pressure effect on human nails. A probe pressure ranging from 0 to 385 kPa was applied for nail spectroscopy. The same trend of intensity change was observed following the previous measurements. The suggested sensing system may be crucial in applications requiring pressure sensing when the human body is subjected to varying pressures, such as exercise, weightlifting, and other sports.

5.
Sci Rep ; 13(1): 10823, 2023 Jul 04.
Article in English | MEDLINE | ID: mdl-37402807

ABSTRACT

Optical fiber (OF) sensors are critical optical devices with excellent sensing capabilities and the capacity to operate in remote and hostile environments. However, integrating functional materials and micro/nanostructures into the optical fiber systems for specific sensing applications has limitations of compatibility, readiness, poor control, robustness, and cost-effectiveness. Herein, we have demonstrated the fabrication and integration of stimuli-responsive optical fiber probe sensors using a novel, low-cost, and facile 3D printing process. Thermal stimulus-response of thermochromic pigment micro-powders was integrated with optical fibers by incorporating them into ultraviolet-sensitive transparent polymer resins and then printed via a single droplet 3D printing process. Hence, the thermally active polymer composite fibers were grown (additively manufactured) on top of the commercial optical fiber tips. Then, the thermal response was studied within the temperature range of (25-35 °C) and (25-31 °C) for unicolor and dual color pigment powders-based fiber-tip sensors, respectively. The unicolor (with color to colorless transition) and dual color (with color to color transition) powders-based sensors exhibited substantial variations in transmission and reflection spectra by reversibly increasing and decreasing temperatures. The sensitivities were calculated from the transmission spectra where average change in transmission spectra was recorded as 3.5% with every 1 °C for blue, 3% for red and 1% for orange-yellow thermochromic powders based optical fiber tip sensors. Our fabricated sensors are cost-effective, reusable, and flexible in terms of materials and process parameters. Thus, the fabrication process can potentially develop transparent and tunable thermochromic sensors for remote sensing with a much simpler manufacturing process compared to conventional and other 3D printing processes for optical fiber sensors. Moreover, this process can integrate micro/nanostructures as patterns on the optical fiber tips to increase sensitivity. The developed sensors may be employed as remote temperature sensors in biomedical and healthcare applications.

6.
Front Bioeng Biotechnol ; 11: 1105377, 2023.
Article in English | MEDLINE | ID: mdl-37304146

ABSTRACT

Decellularized corneas offer a promising and sustainable source of replacement grafts, mimicking native tissue and reducing the risk of immune rejection post-transplantation. Despite great success in achieving acellular scaffolds, little consensus exists regarding the quality of the decellularized extracellular matrix. Metrics used to evaluate extracellular matrix performance are study-specific, subjective, and semi-quantitative. Thus, this work focused on developing a computational method to examine the effectiveness of corneal decellularization. We combined conventional semi-quantitative histological assessments and automated scaffold evaluations based on textual image analyses to assess decellularization efficiency. Our study highlights that it is possible to develop contemporary machine learning (ML) models based on random forests and support vector machine algorithms, which can identify regions of interest in acellularized corneal stromal tissue with relatively high accuracy. These results provide a platform for developing machine learning biosensing systems for evaluating subtle morphological changes in decellularized scaffolds, which are crucial for assessing their functionality.

7.
ACS Biomater Sci Eng ; 9(7): 4381-4391, 2023 07 10.
Article in English | MEDLINE | ID: mdl-37364228

ABSTRACT

3D printing of multimaterial objects is an emerging field with promising applications. The layer-by-layer material addition technique used in 3D printing enables incorporation of distinct functionalized materials into the specialized devices. However, very few studies have been performed on the usage of multimaterial 3D printing for printable photonic and wearable devices. Here, we employ vat photopolymerization-based 3D printing to produce multimaterial contact lenses, offering enhanced multiband optical filtration, which can be valuable for tackling ocular conditions such as color blindness. A combination of hydroxyethyl methacrylate (HEMA) and polyethylene glycol diacrylate (PEGDA) was used as the base hydrogel for 3D printing. Atto565 and Atto488 dyes were added to the hydrogel for wavelength filtering, each dye suitable for a different type of color blindness. Multimaterial disks and contact lenses, with separate sections containing distinct dyes, were 3D-printed, and their optical properties were studied. The characteristics of multimaterial printing were analyzed, focusing on the formation of a uniform multimaterial interface. In addition, a novel technique was developed for printing multiple dyed materials in complex lateral geometrical patterns, by employing suitable variations in CAD models and the UV curing time. It was observed that the multimaterial printing process does not negatively affect the optical properties of the contact lenses. The printed multimaterial contact lenses offered a combined multi-band color blindness correction due to the two dyes used. The resulting optical spectrum was a close match to the commercially available color blindness correction glasses.


Subject(s)
Contact Lenses , Printing, Three-Dimensional , Hydrogels/chemistry , Software , Materials Testing
8.
Front Bioeng Biotechnol ; 11: 1133122, 2023.
Article in English | MEDLINE | ID: mdl-37180037

ABSTRACT

Introduction: Corneal disease is a leading cause of blindness globally that stems from various etiologies. High-throughput platforms that can generate substantial quantities of corneal grafts will be invaluable in addressing the existing global demand for keratoplasty. Slaughterhouses generate substantial quantities of underutilized biological waste that can be repurposed to reduce current environmentally unfriendly practices. Such efforts to support sustainability can simultaneously drive the development of bioartificial keratoprostheses. Methods: Scores of discarded eyes from the prominent Arabian sheep breeds in our surrounding region of the United Arab Emirates (UAE) were repurposed to generate native and acellular corneal keratoprostheses. Acellular corneal scaffolds were created using a whole-eye immersion/agitation-based decellularization technique with a widely available, eco-friendly, and inexpensive 4% zwitterionic biosurfactant solution (Ecover, Malle, Belgium). Conventional approaches like DNA quantification, ECM fibril organization, scaffold dimensions, ocular transparency and transmittance, surface tension measurements, and Fourier-transform infrared (FTIR) spectroscopy were used to examine corneal scaffold composition. Results: Using this high-throughput system, we effectively removed over 95% of the native DNA from native corneas while retaining the innate microarchitecture that supported substantial light transmission (over 70%) after reversing opacity, a well-established hallmark of decellularization and long-term native corneal storage, with glycerol. FTIR data revealed the absence of spectral peaks in the frequency range 2849 cm-1 to 3075 cm-1, indicating the effective removal of the residual biosurfactant post-decellularization. Surface tension studies confirmed the FTIR data by capturing the surfactant's progressive and effectual removal through tension measurements ranging from approximately 35 mN/m for the 4% decellularizing agent to 70 mN/m for elutes highlighting the effective removal of the detergent. Discussion: To our knowledge, this is the first dataset to be generated outlining a platform that can produce dozens of ovine acellular corneal scaffolds that effectively preserve ocular transparency, transmittance, and ECM components using an eco-friendly surfactant. Analogously, decellularization technologies can support corneal regeneration with attributes comparable to native xenografts. Thus, this study presents a simplified, inexpensive, and scalable high-throughput corneal xenograft platform to support tissue engineering, regenerative medicine, and circular economic sustainability.

9.
Polymers (Basel) ; 15(8)2023 Apr 07.
Article in English | MEDLINE | ID: mdl-37111961

ABSTRACT

Flexible photonic devices based on soft polymers enable real-time sensing of environmental conditions in various industrial applications. A myriad of fabrication techniques have been established for producing optical devices, including photo and electron-beam lithography, nano/femtosecond laser writing, and surface imprinting or embossing. However, among these techniques, surface imprinting/embossing is simple, scalable, convenient to implement, can produce nanoscale resolutions, and is cost-effective. Herein, we utilize the surface imprinting method to replicate rigid micro/nanostructures onto a commonly available PDMS substrate, enabling the transfer of rigid nanostructures into flexible forms for sensing at a nanometric scale. The sensing nanopatterned sheets were mechanically extended, and the extension was remotely monitored via optical methods. Monochromatic light (450, 532, and 650 nm) was transmitted through the imprinted sensor under various force/stress levels. The optical response was recorded on an image screen and correlated with the strain created by the applied stress levels. The optical response was obtained in diffraction pattern form from the flexible grating-based sensor and in an optical-diffusion field form from the diffuser-based sensor. The calculated Young's modulus in response to the applied stress, measured through the novel optical method, was found in a reasonable range compared to the reported range of PDMS (360-870 kPa) in the literature.

10.
Molecules ; 28(3)2023 Jan 31.
Article in English | MEDLINE | ID: mdl-36771005

ABSTRACT

The benefits of enclosing pH sensors into wound dressings include treatment monitoring of wounded skin and early detection of developing chronic conditions, especially for diabetic patients. A 3D printed re-entrant auxetic hydrogel wound dressing, doped with pH indicator phenol red dye, was developed and characterized. The re-entrant auxetic design allows wound dressing adhesion to complex body parts, such as joints on arms and legs. Tensile tests revealed a yield strength of 140 kPa and Young's modulus of 78 MPa. In addition, the 3D-printed hydrogel has a swelling capacity of up to 14%, limited weight loss to 3% in six days, and porosity of near 1.2%. A reasonable pH response resembling human skin pH (4-10) was obtained and characterized. The integration of color-changing pH indicators allows patients to monitor the wound's healing process using a smartphone. In addition to the above, the mechanical properties and their dependence on post-processing were studied. The results show that the resin composition and the use of post-treatments significantly affect the quality and durability of the wound dressings. Finally, a poly (acrylic acid) (PAA) and water-based adhesive was developed and used to demonstrate the performance of the auxetic wound dressing when attached to moving body joints.


Subject(s)
Bandages , Hydrogels , Humans , Hydrogels/chemistry , Skin/injuries , Printing, Three-Dimensional , Hydrogen-Ion Concentration
11.
ACS Appl Bio Mater ; 5(12): 5545-5553, 2022 12 19.
Article in English | MEDLINE | ID: mdl-36441920

ABSTRACT

Wound healing is a huge challenge worldwide causing enormous financial burden on healthcare systems. Although conventional wound dressings, such as hydrogels, bandages, and foams, facilitate wound healing, they lack the ability to monitor the wound healing process. Here, hydrogel wound dressings in the form of auxetic structures were developed by a digital light processing (DLP) printer. Paper-based colorimetric sensors were incorporated with the 3D printed auxetic hydrogel skin wound patches for monitoring the wound status through detecting pH levels and glucose concentrations. The paper-based sensors are profoundly cost-effective and were found to be capable of monitoring the wound's conditions. The developed wound dressings may assist in preventing escalation of the acute wounds into chronic stages in diabetics.


Subject(s)
Hydrogels , Soft Tissue Injuries , Humans , Hydrogels/therapeutic use , Bandages , Wound Healing , Skin , Printing, Three-Dimensional
12.
Sensors (Basel) ; 22(21)2022 Nov 04.
Article in English | MEDLINE | ID: mdl-36366186

ABSTRACT

A sensor for monitoring of the external corrosion of small-diameter aboveground oil and gas pipelines (called flowlines), based on fiber-optic strain sensing, is proposed. The working principle of our proposed sensor relies on the use of a pre-stressed sacrificial structure made of the same material as the pipeline and monitoring changes in the measured strain that occur due to deterioration caused by corrosion to the structure. We present the development of analytical equations that allow designing the sensor structure to achieve the desired strain values. The analysis was verified using commercial finite element analysis (FEA) software. The proposed sensor is simple and cost-effective and can be easily manufactured. It can be deployed on existing overground pipelines without any modification to the pipeline structure. While it is not capable of measuring the corrosion rate continuously, it can provide a measurement of the average corrosion rate over the life span of its sacrificial metal structure.

13.
Int J Mol Sci ; 23(19)2022 Oct 05.
Article in English | MEDLINE | ID: mdl-36233102

ABSTRACT

Computational chemistry, molecular docking, and drug design approaches, combined with the biochemical evaluation of the antitumor activity of selected derivatives of the thiouracil-based dihydroindeno pyrido pyrimidines against topoisomerase I and II. The IC50 of other cell lines including the normal human lung cell line W138, lung cancer cell line, A549, breast cancer cell line, MCF-7, cervical cancer, HeLa, and liver cancer cell line HepG2 was evaluated using biochemical methods. The global reactivity descriptors and physicochemical parameters were computed, showing good agreement with the Lipinski and Veber's rules of the drug criteria. The molecular docking study of the ligands with the topoisomerase protein provides the binding sites, binding energies, and deactivation constant for the inhibition pocket. Various biochemical methods were used to evaluate the IC50 of the cell lines. The QSAR model was developed for colorectal cell line HCT as a case study. Four QSAR statistical models were predicted between the IC50 of the colorectal cell line HCT to correlate the anticancer activity and the computed physicochemical and quantum chemical global reactivity descriptors. The predictive power of the models indicates a good correlation between the observed and the predicted activity.


Subject(s)
Antineoplastic Agents , Colorectal Neoplasms , Antineoplastic Agents/chemistry , Antineoplastic Agents/pharmacology , Cell Line, Tumor , Cell Proliferation , DNA Topoisomerases, Type I/metabolism , DNA Topoisomerases, Type II/metabolism , Drug Screening Assays, Antitumor , Humans , Molecular Docking Simulation , Molecular Structure , Pyrimidines/pharmacology , Quantitative Structure-Activity Relationship , Structure-Activity Relationship , Thiouracil/pharmacology
14.
Accid Anal Prev ; 176: 106792, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35952395

ABSTRACT

Bicyclists and pedestrians are two large vulnerable groups of road users. Many cities have allowed cyclists to share space with pedestrians on footpaths and off-road paths to reduce conflict with motor vehicles. The risk of bicyclist-pedestrian accidents is also increasing accordingly. Therefore, there is a need to understand the factors that affect the risk of injury in such accidents, especially to pedestrians who are considered more vulnerable. This paper presents a detailed investigation of bicyclist-pedestrian collisions and possible injury outcomes. The study has considered five levels of collision speed ranging from 10 km/h to 30 km/h, three pedestrian profiles (adult, child, and elderly) differentiated by their weight and height, three bicycles with different masses, and five impact directions. The bicyclist-pedestrian collision simulations have been analyzed based on four metrics: throw distance, peak head velocity on impact with the ground, head injury criterion (HIC) value, and the probability of severe head injury. For each simulation, the throw distance and peak head velocity on impact with the ground are extracted. Following that, the HIC and the probability of severe head injury to pedestrians are computed. The results show a significant effect of collision speed (p < 0.05) on all four metrics. The analysis has been further extended to study the effect of height and weight profile, bicycle mass, and impact directions on bicyclist-pedestrian collisions. According to the results, the impact directions largely influence the outcome of bicycle-pedestrian collisions. In general, direct impacts on pedestrian body center have been found to yield higher HIC values and probability of severe head injury to pedestrians than off-center impacts. Also, video analysis of simulated collisions has suggested that the accident mechanism depends on weight and height profiles (correlated with different age groups) and impact directions. Finally, recommendations have been proposed based on the study, including a speed limit of not more than 12 km/h for bicyclists on narrow shared paths and footpaths where risks of collisions with pedestrians are high. The results and analysis presented could be helpful for developing legislation to minimize conflicts between bicyclists and pedestrians on shared paths and to reduce potential injury to pedestrians.


Subject(s)
Accidents, Traffic , Bicycling , Craniocerebral Trauma , Pedestrians , Walking , Adult , Aged , Child , Humans , Accidents, Traffic/prevention & control , Bicycling/injuries , Body Height , Body Weight , Craniocerebral Trauma/epidemiology , Craniocerebral Trauma/etiology , Craniocerebral Trauma/prevention & control , Walking/injuries , Wounds and Injuries/etiology , Wounds and Injuries/prevention & control
15.
Sensors (Basel) ; 22(11)2022 May 24.
Article in English | MEDLINE | ID: mdl-35684610

ABSTRACT

We propose a sensor design for measurement of large strains where direct application of a fiber optic strain gauge is impossible due to the stiffness mismatch between the optical fiber and the structure under test. The sensor design is based on a rhombus type compliant mechanism, which functions to attenuate input strain and transfer it to the ends of the sensing beam with the mounted optical strain gauge. We developed an analytical model of the sensor, which allows us to relate actuation forces, input displacement/strain, and output strain. The analytical model was verified with the finite element analysis and validated against an experimental prototype. The prototype sensor was able to handle input strains exceeding ±2.5 × 105 µÎµ. Potential application areas of the proposed sensor include compliant elastomeric structures, wearables, and soft robotics.


Subject(s)
Fiber Optic Technology , Robotics , Finite Element Analysis , Optical Fibers
16.
Nanomaterials (Basel) ; 12(9)2022 Apr 27.
Article in English | MEDLINE | ID: mdl-35564192

ABSTRACT

Surface functionalization of metallic nanoparticles (NPs) with external groups can be engineered to fabricate sensors that are responsive to various stimuli like temperature, pH, and numerous ions. Herein, we report the synthesis of gold nanoparticles (GNPs) functionalized with 3-mercaptopropionic acid (GNPs-MPA) and the doping of these nanoparticles into hydrogel materials using the breathing-in/breathing-out (BI-BO) method. MPA has a carboxyl group that becomes protonated and, thus, ionized at a pH below its pKa (4.32); hence, the GNPs-MPA solutions and gels were mostly pH-responsive in the range of 3-5. Optical properties were assessed through ultraviolet-visible (UV-Vis) spectroscopy, namely: transmission and absorption, and the parameters used to quantify the pH changes were the full width at half maximum (FWHM) and position of surface plasmon resonance (SPR). The solutions and gels gradually changed their colors from red to indigo with pH decrementation from 5 to 3, respectively. Furthermore, the solutions' and doped gels' highest FWHM sensitivities towards pH variations were 20 nm and 55 nm, respectively, while the SPR's position sensitivities were 18 nm and 10 nm, respectively. Also, transmission and scanning electron microscopy showed synchronized dispersion and aggregation of NPs with pH change in both solution and gel forms. The gel exhibited excellent repeatability and reversibility properties, and its response time was instantaneous, which makes its deployment as a colorimetric pH-triggered sensor practical. To the best of our knowledge, this is the first study that has incorporated GNPs into hydrogels utilizing the BI-BO method and demonstrated the pH-dependent optical and colorimetric properties of the developed nanocomposites.

17.
ACS Biomater Sci Eng ; 8(5): 2111-2120, 2022 05 09.
Article in English | MEDLINE | ID: mdl-35468279

ABSTRACT

Integration of nanomaterials into hydrogels has emerged as a prominent research tool utilized in applications such as sensing, cancer therapy, and bone tissue engineering. Wearable contact lenses functionalized with nanoparticles have been exploited in therapeutics and targeted therapy. Here, we report the fabrication of gold and silver nanocomposite commercial contact lenses using a breathing-in/breathing-out (BI-BO) method, whereby a hydrated contact lens is shrunk in an aprotic solvent and then allowed to swell in an aqueous solution containing nanoparticles. The morphology and optical properties of the gold and silver nanoparticles were characterized through transmission electron microscopy and ultraviolet-visible spectroscopy. The transmission spectra of nanocomposite contact lenses indicated that the nanoparticles' loading amount within the lens depended primarily on the number of BI-BO cycles. Nanocomposites were stable for a minimum period of 1 month, and no nanoparticle leaching was observed. Wettability and water content analysis of the nanocomposites revealed that the contact lenses retained their intrinsic material properties after the fabrication process. The dispersion of the nanoparticles within the contact lens media was determined through scanning electron microscopy imaging. The nanocomposite lenses can be deployed in color filtering and antibacterial applications. In fact, the silver nanocomposite contact lens showed blue-light blocking capabilities by filtering a harmful high-energy blue-light range (400-450 nm) while transmitting the visible light beyond 470 nm, which facilitates enhanced night vision and color distinction. The ease of fabricating these nanocomposite contact lenses via the BI-BO method could enable the incorporation of nanoparticles with diverse morphologies into contact lenses for various biomedical applications.


Subject(s)
Contact Lenses , Metal Nanoparticles , Nanocomposites , Gold , Hydrogels/chemistry , Silver
18.
Front Med (Lausanne) ; 9: 858784, 2022.
Article in English | MEDLINE | ID: mdl-35445050

ABSTRACT

Diabetes mellitus is a chronic disease requiring a careful management to prevent its collateral complications, such as cardiovascular and Alzheimer's diseases, retinopathy, nephropathy, foot and hearing impairment, and neuropathy. Self-monitoring of blood glucose at point-of-care settings is an established practice for diabetic patients. However, current technologies for glucose monitoring are invasive, costly, and only provide single snapshots for a widely varying parameter. On the other hand, tears are a source of physiological information that mirror the health state of an individual by expressing different concentrations of metabolites, enzymes, vitamins, salts, and proteins. Therefore, the eyes may be exploited as a sensing site with substantial diagnostic potential. Contact lens sensors represent a viable route for targeting minimally-invasive monitoring of disease onset and progression. Particularly, glucose concentration in tears may be used as a surrogate to estimate blood glucose levels. Extensive research efforts recently have been devoted to develop smart contact lenses for continual glucose detection. The latest advances in the field are reviewed herein. Sensing technologies are described, compared, and the associated challenges are critically discussed.

19.
Polymers (Basel) ; 14(5)2022 Mar 03.
Article in English | MEDLINE | ID: mdl-35267835

ABSTRACT

Wounds are a major health concern affecting the lives of millions of people. Some wounds may pass a threshold diameter to become unrecoverable by themselves. These wounds become chronic and may even lead to mortality. Recently, 3D printing technology, in association with biocompatible hydrogels, has emerged as a promising platform for developing smart wound dressings, overcoming several challenges. 3D printed wound dressings can be loaded with a variety of items, such as antibiotics, antibacterial nanoparticles, and other drugs that can accelerate wound healing rate. 3D printing is computerized, allowing each level of the printed part to be fully controlled in situ to produce the dressings desired. In this review, recent developments in hydrogel-based wound dressings made using 3D printing are covered. The most common biosensors integrated with 3D printed hydrogels for wound dressing applications are comprehensively discussed. Fundamental challenges for 3D printing and future prospects are highlighted. Additionally, some related nanomaterial-based hydrogels are recommended for future consideration.

20.
Biosensors (Basel) ; 12(1)2022 Jan 13.
Article in English | MEDLINE | ID: mdl-35049668

ABSTRACT

Measuring pH has become a major key for determining health conditions, and food safety. The traditional pH assessment approaches are costly and offer low sensitivity. Here, a novel pH sensor based on a pH-responsive hydrogel has been developed. A Fresnel lens pattern was replicated on the surface of the pH-responsive hydrogel using the replica mould method. The pH sensors were tested in a pH range of 4-7. Introducing various pH solutions to the pH sensor led to volumetric shifts as the hydrogel swelled with pH. Consequently, the dimensions of the replicated Fresnel lens changed, modifying the focal length and the focus efficiency of the optical sensor. As a result, the measured optical power at a fixed distance from the sensor changed with pH. The optical sensor showed the best performance in the acidic region when pH changed from 4.5 to 5.5, in which the recorded power increased by 13%. The sensor exhibited high sensitivity to pH changes with a short respond time in a reversible manner. The developed pH optical sensor may have applications in medical point-of-care diagnostics and wearable continuous pH detection devices.


Subject(s)
Hydrogels , Wearable Electronic Devices , Hydrogen-Ion Concentration
SELECTION OF CITATIONS
SEARCH DETAIL
...