Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
J Perinat Med ; 51(7): 913-919, 2023 Sep 26.
Article in English | MEDLINE | ID: mdl-37097317

ABSTRACT

OBJECTIVES: The present study aimed to evaluate the performance of QuantusFLM® software, which performs quantitative ultrasound analysis of fetal lung texture, in predicting lung maturity in fetuses of diabetic mothers. METHODS: The patients included in this study were between 34 and 38 weeks and 6 days gestation and were divided into two groups: (1) patients with diabetes on medication and (2) control. The ultrasound images were performed up to 48 h prior to delivery and analyzed using QuantusFLM® software, which classified each fetus as high or low risk for neonatal respiratory morbidity based on lung maturity or immaturity. RESULTS: A total of 111 patients were included in the study, being 55 in diabetes and 56 in control group. The pregnant women with diabetes had significantly higher body mass index (27.8 kg/m2 vs. 25.9 kg/m2, respectively, p=0.02), increased birth weight (3,135 g vs. 2,887 g, respectively, p=0.002), and a higher rate of labor induction (63.6 vs. 30.4 %, respectively, p<0.001) compared to the control group. QuantusFLM® software was able to predict lung maturity in diabetes group with 96.4 % accuracy, 96.4 % sensitivity and 100 % positive predictive value. Considering the total number of patients, the software demonstrated accuracy, sensitivity, specificity, positive predictive value and negative predictive value of 95.5 , 97.2, 33.3, 98.1 and 25 %, respectively. CONCLUSIONS: QuantusFLM® was an accurate method for predicting lung maturity in normal and DM singleton pregnancies and has the potential to aid in deciding the timing of delivery for pregnant women with DM.


Subject(s)
Diabetes Mellitus , Lung , Infant, Newborn , Humans , Pregnancy , Female , Lung/diagnostic imaging , Ultrasonography, Prenatal/methods , Prospective Studies , Ultrasonography , Gestational Age
2.
Ultrasound Med Biol ; 48(1): 20-26, 2022 01.
Article in English | MEDLINE | ID: mdl-34607759

ABSTRACT

The present study aimed to evaluate the performance of QuantusFLM software, which performs quantitative analysis of lung tissue texture through ultrasound images, in predicting lung maturity in fetal growth restriction (FGR). We included patients with singleton gestations between 34 and 38 6/7 wk and divided them into two groups: FGR and control (appropriate for gestational age [AGA]). The images were captured by ultrasound according to a specific protocol up to 48 h before delivery and analyzed with QuantusFLM software. The main clinical outcome evaluated was lung maturity (i.e., the absence of neonatal respiratory morbidity). We included 111 patients; one was excluded because of low image quality, leaving 55 patients in each group. The FGR group had a lower birth weight (2207 g vs. 2891 g, p < 0.001) and a longer stay in the neonatal intensive care unit (NICU) (10 d vs. 5 d, p = 0.043). QuantusFLM software was able to predict lung maturity in FGR with accuracy, sensitivity, specificity and positive and negative predictive values of 94.5%, 96.2%, 50%, 98.1% and 33.3%, respectively. QuantusFLM had good accuracy in predicting lung maturity in FGR with reliability in identifying pulmonary maturity.


Subject(s)
Fetus , Ultrasonography, Prenatal , Female , Fetal Growth Retardation/diagnostic imaging , Gestational Age , Humans , Infant, Newborn , Lung/diagnostic imaging , Pregnancy , Reproducibility of Results
3.
Data Brief ; 34: 106746, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33532526

ABSTRACT

The genus Klebsiella comprises species that cause nosocomial and community-acquired infections. A dataset was created to compile the sequence type (ST) and capsule type (K-locus) information predicted for 172 worldwide isolates of Klebsiella spp. whose complete genomes could be retrieved from the GenBank (NCBI) repository. The dataset also includes information related to one multidrug-resistant strain (B31) isolated from a patient who was admitted to an intensive care unit in the Northeast region of Brazil. This strain was phenotypically characterized and submitted to whole-genome sequencing and comparative genomics analysis as we recently reported [1]. The dataset also compiles information on Pathogenicity Islands (PIs), Resistance Islands (RIs) and Miscellaneous Islands (MIS) present in the genome of strain B31. The information provided here may support outbreak prevention policies and future epidemiological studies involving Klebsiella spp.

4.
Mem Inst Oswaldo Cruz ; 115: e200287, 2021.
Article in English | MEDLINE | ID: mdl-33533869

ABSTRACT

BACKGROUND: The heat-labile nature of Dengue virus (DENV) in serum samples must be considered when applying routine diagnostic tests to avoid issues that could impact the accuracy of test results with direct implications for case management and disease reporting. OBJECTIVES: To check if pre-analytical variables, such as storage time and temperature, have an impact on the accuracy of the main routine diagnostic tests for dengue. METHODS: Virus isolation, reverse transcription real-time polymerase chain reaction (RT-PCR) and NS1 enzyme-linked immunosorbent assay (ELISA) were evaluated using 84 samples submitted to different pre-analytical conditions. FINDINGS: Sensitivity and negative predictive value were directly affected by sample storage conditions. RT-PCR and virus isolation showed greater dependence on well-conserved samples for an accurate diagnosis. Interestingly, even storage at -30ºC for a relatively short time (15 days) was not adequate for accurate results using virus isolation and RT-PCR tests. On the other hand, NS1 ELISA showed no significant reduction in positivity for aliquots tested under the same conditions as in the previous tests. MAIN CONCLUSIONS: Our results support the stability of the NS1 marker in ELISA diagnosis and indicate that the accuracy of routine tests such as virus isolation and RT-PCR is significantly affected by inadequate transport and storage conditions of serum samples.


Subject(s)
Antigens, Viral/blood , Dengue Virus/isolation & purification , Dengue/diagnosis , Enzyme-Linked Immunosorbent Assay/methods , Immunologic Tests/methods , Reverse Transcriptase Polymerase Chain Reaction/methods , Viral Nonstructural Proteins/immunology , Antibodies, Viral/blood , Antigens, Viral/immunology , Dengue/blood , Dengue/virology , Dengue Virus/genetics , Dengue Virus/immunology , Humans , Predictive Value of Tests , Sensitivity and Specificity , Viral Nonstructural Proteins/genetics
5.
Gene ; 772: 145386, 2021 Mar 10.
Article in English | MEDLINE | ID: mdl-33373662

ABSTRACT

The emergence of community acquired infections increases the public health concern on K. pneumoniae and closely related bacteria among which antimicrobial resistance spreads. We report a multidrug-resistant K. pneumoniae isolate, B31, of a patient infected in the community and admitted to an intensive care unit in Northeast Brazil. Antimicrobial susceptibility and genome information were thoroughly investigated to characterize B31 in front of 172 sequenced strains of different countries. Assigned to the Sequence Type 15, which is globally spread, B31 presented extended spectrum beta-lactamase, tigecycline and ciprofloxacin resistance. Genome sequencing revealed most resistance genes being carried by plasmids with high dissemination potential. The absence of main virulence factors, like yersiniabactin and colibactin, apparently suggests a mild pathogenic strain which, on the contrary, persisted and caused severe infection in a previously healthy patient. The present study contributes to unveil the unclear genomic scenario of virulent and multidrug-resistant K. pneumoniae in Brazil.


Subject(s)
Community-Acquired Infections/microbiology , Drug Resistance, Multiple, Bacterial , Klebsiella Infections/microbiology , Klebsiella pneumoniae/classification , Whole Genome Sequencing/methods , Adult , Ciprofloxacin/pharmacology , Female , Genome, Bacterial , High-Throughput Nucleotide Sequencing , Humans , Klebsiella pneumoniae/genetics , Multilocus Sequence Typing , Plasmids/genetics , Tigecycline/pharmacology
8.
Mem. Inst. Oswaldo Cruz ; 115: e200287, 2020. tab, graf
Article in English | LILACS | ID: biblio-1154869

ABSTRACT

BACKGROUND The heat-labile nature of Dengue virus (DENV) in serum samples must be considered when applying routine diagnostic tests to avoid issues that could impact the accuracy of test results with direct implications for case management and disease reporting. OBJECTIVES To check if pre-analytical variables, such as storage time and temperature, have an impact on the accuracy of the main routine diagnostic tests for dengue. METHODS Virus isolation, reverse transcription real-time polymerase chain reaction (RT-PCR) and NS1 enzyme-linked immunosorbent assay (ELISA) were evaluated using 84 samples submitted to different pre-analytical conditions. FINDINGS Sensitivity and negative predictive value were directly affected by sample storage conditions. RT-PCR and virus isolation showed greater dependence on well-conserved samples for an accurate diagnosis. Interestingly, even storage at -30ºC for a relatively short time (15 days) was not adequate for accurate results using virus isolation and RT-PCR tests. On the other hand, NS1 ELISA showed no significant reduction in positivity for aliquots tested under the same conditions as in the previous tests. MAIN CONCLUSIONS Our results support the stability of the NS1 marker in ELISA diagnosis and indicate that the accuracy of routine tests such as virus isolation and RT-PCR is significantly affected by inadequate transport and storage conditions of serum samples.


Subject(s)
Humans , Immunologic Tests/methods , Enzyme-Linked Immunosorbent Assay/methods , Viral Nonstructural Proteins/immunology , Reverse Transcriptase Polymerase Chain Reaction/methods , Dengue/diagnosis , Dengue Virus/isolation & purification , Antigens, Viral/blood , Predictive Value of Tests , Sensitivity and Specificity , Viral Nonstructural Proteins/genetics , Dengue/blood , Dengue/virology , Dengue Virus/genetics , Dengue Virus/immunology , Antibodies, Viral/blood , Antigens, Viral/immunology
9.
Sci Rep ; 9(1): 16336, 2019 11 08.
Article in English | MEDLINE | ID: mdl-31704997

ABSTRACT

Exfoliative toxins (ETs) are secreted virulence factors produced by staphylococci. These serine proteases specifically cleave desmoglein 1 (Dsg1) in mammals and are key elements in staphylococcal skin infections. We recently identified a new et gene in S. aureus O46, a strain isolated from ovine mastitis. In the present study, we characterized the new et gene at a genetic level and the enzymatic activity of the deduced protein. The S. aureus O46 genome was re-assembled, annotated and compared with other publicly available S. aureus genomes. The deduced amino acid sequence of the new et gene shared 40%, 53% and 59% sequence identity to those of ETA, ETB and ETD, respectively. The new et gene shared the same genetic vicinity and was similar in other S. aureus strains bearing this gene. The recombinant enzyme of the new et gene caused skin exfoliation in vivo in neonatal mice. The new et-gene was thus named ete, encoding a new type (type E) of exfoliative toxin. We showed that ETE degraded the extracellular segments of Dsg1 in murine, ovine and caprine epidermis, as well as in ovine teat canal epithelia, but not that in bovine epidermis. We further showed that it directly hydrolyzed human and swine Dsg1 as well as murine Dsg1α and Dsg1ß, but not canine Dsg1 or murine Dsg1γ. Molecular modeling revealed a correlation between the preferred orientation of ETE docking on its Dsg1 cleavage site and species-specific cleavage activity, suggesting that the docking step preceding cleavage accounts for the ETE species-specificity. This new virulence factor may contribute to the bacterial colonization on the stratified epithelia in certain ruminants with mastitis.


Subject(s)
Host Specificity , Staphylococcus aureus/metabolism , Toxins, Biological/metabolism , Amino Acid Sequence , Animals , Extracellular Space/metabolism , Genome, Bacterial/genetics , Hydrolysis , Mice , Molecular Docking Simulation , Protein Conformation , Ruminants/microbiology , Staphylococcus aureus/genetics , Staphylococcus aureus/physiology , Toxins, Biological/chemistry
10.
Taiwan J Obstet Gynecol ; 58(1): 15-28, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30638470

ABSTRACT

The aim of the current review is to report a-CGH abnormalities identified in fetuses with prenatally diagnosed fetal malformations in whom a normal karyotype was diagnosed with conventional cytogenetic analysis. A systematic electronic search of databases (PubMed/Medline, EMBASE/SCOPUS) has been conducted from inception to May, 2017. Bibliographic analysis has been performed according to PRISMA statement for review. The following keywords were used: 'array-CGH' and 'fetal malformations" and "prenatal diagnosis"; alternatively, "microarray", "oligonucleotide array", "molecular biology", "antenatal diagnostics", "fetal diagnostics", "congenital malformations" and "ultrasound" were used to capture both "a-CGH" and "prenatal". One-hundred and twelve fetuses with prenatally diagnosed fetal malformations with normal karyotyping and a-CGH abnormalities detected are described. Single or multiple microarray abnormalities diagnosed have been classified in relation to different organ/system affected. The most frequent a-CGH abnormalities were detected in cases of congenital heart diseases (CDHs), multiple malformations and central nervous system (CNS) malformations. Maternal or paternal carrier-state was seen in 19.64% (22/112), of cases while the number of reported de novo mutations accounted for 46.42% (52/112) of all CNVs microarray abnormalities. Array-comparative genomic hydridization (a-CGH) may become an integral and complemantary genetic testing when fetal malformations are detected prenatally in fetuses with normal cytogenetic karyotype. In addition, a-CGH enables the identification of CNVs and VOUS and improves the calculation of recurrent risk and the genetic counseling.


Subject(s)
Abnormalities, Multiple/genetics , Chromosome Aberrations/embryology , Comparative Genomic Hybridization , Heart Defects, Congenital/genetics , Oligonucleotide Array Sequence Analysis , Prenatal Diagnosis/methods , Abnormalities, Multiple/diagnosis , Central Nervous System/abnormalities , Central Nervous System/embryology , Female , Heart Defects, Congenital/diagnosis , Humans , Karyotyping/methods , Maternal Age , Pregnancy , Risk Factors
11.
Arch Gynecol Obstet ; 295(5): 1061-1077, 2017 May.
Article in English | MEDLINE | ID: mdl-28285426

ABSTRACT

BACKGROUND: Fetal growth restriction (FGR) is a condition that affects 5-10% of pregnancies and is the second most common cause of perinatal mortality. This review presents the most recent knowledge on FGR and focuses on the etiology, classification, prediction, diagnosis, and management of the condition, as well as on its neurological complications. METHODS: The Pubmed, SCOPUS, and Embase databases were searched using the term "fetal growth restriction". RESULTS: Fetal growth restriction (FGR) may be classified as early or late depending on the time of diagnosis. Early FGR (<32 weeks) is associated with substantial alterations in placental implantation with elevated hypoxia, which requires cardiovascular adaptation. Perinatal morbidity and mortality rates are high. Late FGR (≥32 weeks) presents with slight deficiencies in placentation, which leads to mild hypoxia and requires little cardiovascular adaptation. Perinatal morbidity and mortality rates are lower. The diagnosis of FGR may be clinical; however, an arterial and venous Doppler ultrasound examination is essential for diagnosis and follow-up. There are currently no treatments to control FGR; the time at which pregnancy is interrupted is of vital importance for protecting both the mother and fetus. CONCLUSION: Early diagnosis of FGR is very important, because it enables the identification of the etiology of the condition and adequate monitoring of the fetal status, thereby minimizing risks of premature birth and intrauterine hypoxia.


Subject(s)
Fetal Growth Retardation , Female , Fetal Development , Fetal Growth Retardation/diagnosis , Fetal Growth Retardation/etiology , Fetal Growth Retardation/therapy , Fetal Hypoxia , Fetus/innervation , Gestational Age , Humans , Infant, Newborn , Perinatal Mortality , Placenta/physiopathology , Placental Insufficiency , Placentation , Pregnancy , Ultrasonography, Prenatal
12.
J Matern Fetal Neonatal Med ; 30(5): 568-573, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27075298

ABSTRACT

OBJECTIVE: To establish reference ranges of the fetal adrenal gland (AG) and fetal zone (FZ) volumes using three-dimensional ultrasound (3DUS). METHODS: We performed a prospective cross-sectional study with 204 normal singleton pregnancies between 24 and 37 + 6 weeks of gestation. The fetal AG and FZ volumes were obtained using the virtual organ computer-aided analysis method with a 30° rotation. To establish reference ranges as the function of gestational age (GA), quantile regression was performed with the adjusted coefficient of determination (R2). Intra- and inter-observer repeatability was performed using the intraclass correlation coefficient (ICC). RESULTS: The mean results of fetal AG and FZ values were 0.42 cm3 (0.04-1.22) and 0.10 cm3 (0.02-0.47), respectively. The best-fit quantile regression models for fetal AG and FZ volumes as the function of GA were in first-degree models: AG = -0.937 + 0.041 × GA (R2 = 0.124) and FZ = -0.201 + 0.009 × GA (R2 = 0.127), respectively. We observed good intra-observer repeatability of fetal AG and FZ volumes, with an ICC of 0.996 and 0.989, respectively. We also observed good inter-observer repeatability, with an ICC of 0.972 and 0.966 for AG and FZ, respectively. CONCLUSION: The reference ranges of AG and FZ volumes using 3DUS between 24 and 37 + 6 weeks of gestation were established and exhibited good repeatability.


Subject(s)
Adrenal Glands/anatomy & histology , Fetal Development , Fetus/anatomy & histology , Imaging, Three-Dimensional/methods , Ultrasonography, Prenatal/methods , Adult , Biomarkers , Cross-Sectional Studies , Female , Gestational Age , Humans , Organ Size , Pregnancy , Prospective Studies , Reference Values , Reproducibility of Results , Young Adult
13.
Med Ultrason ; 18(2): 207-13, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27239656

ABSTRACT

AIM: To evaluate the modified myocardial performance index (Mod-MPI) in foetuses with growth restriction and compare this index with appropriate for gestational age foetuses. MATERIAL AND METHODS: A prospective cross-sectional case-control study was conducted involving 76 singleton foetuses between 24 and 34 weeks of gestation divided into three groups (24 appropriate growth foetuses, 30 foetuses with estimated weight between the 3rd and 10th percentiles and 22 foetuses with estimated weight < 3rd percentile, according to the Hadlock table). The Mod-MPI was obtained in the plane of the four chamber view, and the spectral Doppler sample volume was placed in the lateral wall of the aorta, close to the mitral valve. Doppler of umbilical artery was normal in all cases. Analysis of variance (ANOVA) was used to compare the groups and the intra-class correlation coefficient (ICC) was used to assess intra- and inter-observer reproducibility. RESULTS: The mean Mod-MPI in the groups of appropriate for gestational age, estimated weight between the 3rd and 10th percentiles, and estimated weight < 3rd percentile was 0.32 +/- 0.05, 0.35 +/- 0.05 and 0.36 +/- 0.06, respectively; there was no statistical difference between the groups (p = 0.072). There was good intra- and inter-observer reproducibility (ICC = 0.726 and 0.760, respectively). CONCLUSION: Mod-MPI was not significantly different between foetuses appropriate for gestational age and those with growth restriction. Mod-MPI proved to be a feasible and reproducible technique.


Subject(s)
Echocardiography, Doppler/methods , Fetal Growth Retardation/physiopathology , Fetal Heart/diagnostic imaging , Fetal Heart/physiopathology , Ultrasonography, Prenatal/methods , Adult , Case-Control Studies , Cross-Sectional Studies , Female , Gestational Age , Humans , Pregnancy , Pregnancy Trimester, Third , Prospective Studies , Reproducibility of Results , Young Adult
14.
J Ultrasound Med ; 34(8): 1397-405, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26206825

ABSTRACT

OBJECTIVES: To assess intracranial structure volumes by 3-dimensional (3D) sonography in fetuses with growth restriction. METHODS: We conducted a prospective cross-sectional case-control study involving 59 fetuses with growth restriction (38 fetuses with estimated weight <3rd percentile and 21 fetuses with estimated weight between 3rd and 10th percentiles, according to Hadlock et al [Radiology 1984; 150:535-540]) and 54 controls between 24 and 34 weeks' gestation. The following fetal intracranial structure volumes were assessed: cerebellum, brain, and frontal region. The volume was assessed by 3D sonography using the extended imaging virtual organ computer-aided analysis method with 10 sequential planes. Analysis of variance was used to compare fetal groups. The intraclass correlation coefficient was used to assess intraobserver and interobserver reproducibility. RESULTS: Statistical significance between the brain, frontal region, and cerebellar volumes and a relationship between the frontal region and the brain in fetuses with estimated weights below the 3rd percentile and controls were observed (P < .001; P < .001; and P = .002; and P = .008, respectively). Good intraobserver and interobserver reproducibility was observed for the fetal brain, frontal region, and cerebellar volumes, with intraclass correlation coefficients of 0.998, 0.997, 0.997, 0.999, 0.997, and 0.998, respectively. CONCLUSIONS: The intracranial structure volumes assessed by 3D sonography using the extended imaging virtual organ computer-aided analysis method were reduced in fetuses with growth restriction (estimated weight <3rd percentile).


Subject(s)
Brain/embryology , Brain/pathology , Fetal Growth Retardation/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Ultrasonography, Prenatal/methods , Female , Humans , Male , Observer Variation , Organ Size , Pregnancy , Reproducibility of Results , Sensitivity and Specificity , User-Computer Interface
15.
J Obstet Gynaecol Res ; 41(9): 1330-6, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26044926

ABSTRACT

AIM: The aim of this study was to assess the Doppler parameters of the ophthalmic artery of pregnant women carrying fetuses with growth restriction (FGR) compared with normal fetuses. MATERIAL AND METHODS: A prospective cross-sectional study was conducted with 120 pregnant women (60 FGR and 60 normal fetuses) between 32 and 40 weeks of gestation. FGR diagnosis was based on an estimated fetal weight below the 10th percentile of the Hadlock curve. Ophthalmic artery Doppler images were obtained with a linear transducer, with color Doppler examination of the region medial to the optic nerve. The following indices were obtained: pulsatility index, resistance index, peak systolic velocity, second peak velocity (P2), end diastolic velocity, and P2 / peak systolic velocity ratio. The Mann-Whitney U-test and Student's t-test were used to compare the groups with regard to quantitative variables, and the χ(2) -test was used for categorical variables. RESULTS: Pulsatility index and resistance index were significantly lower in pregnant women with FGR than in those with normal fetuses, with P < 0.001 in both indices. P2 and end diastolic velocity were significantly higher in pregnant women with FGR than in those with normal fetuses (P = 0.002 and P = 0.004, respectively). The P2 / peak systolic velocity ratio was significantly higher in the FGR group than in the control group (P < 0.001). In FGR subgroups, with (17 fetuses) and without (43 fetuses) uterine artery Doppler abnormalities, no significant changes were observed between the groups. CONCLUSION: In the third trimester of pregnancy, we observed significant differences in the ophthalmic artery Doppler parameters of pregnant women with FGR compared with those with normal fetuses.


Subject(s)
Fetal Growth Retardation/diagnostic imaging , Ophthalmic Artery/diagnostic imaging , Adult , Case-Control Studies , Cross-Sectional Studies , Echocardiography, Doppler , Female , Fetal Growth Retardation/physiopathology , Gestational Age , Humans , Ophthalmic Artery/physiopathology , Pregnancy , Pregnancy Trimester, Third , Prospective Studies , Ultrasonography, Prenatal , Young Adult
16.
J Matern Fetal Neonatal Med ; 28(9): 1047-52, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25001426

ABSTRACT

OBJECTIVE: To assess the usefulness of estimating fetal upper arm and thigh volumes as predictors of low postnatal body mass index (BMI) using three-dimensional ultrasonography (3DUS) with extended imaging virtual organ computer-aided analysis (XI VOCAL). METHODS: This prospective cross-sectional study analyzed 300 singleton pregnancies between 33 and 41 weeks of gestation. The Hadlock 4 formula was used to estimate fetal weight. The XI VOCAL 10 planes method was used to assess fetal upper arm and thigh volumes. After delivery, the newborns' BMI was evaluated and considered low (≤10th percentile) or normal (>10th percentile). We determined receiver operating characteristics (ROC) curves and respective areas under the curves for the percentiles of fetal weight and fetal thigh and upper arm volumes. RESULTS: Of the 300 newborns, BMI was ≤10th percentile for 21 and >10th percentile for 279 newborns. The area under the ROC curve for fetal weight, obtained using the Hadlock formula, and fetal upper arm and thigh volumes, obtained by 3DUS, were 0.801, 0.930 and 0.924, respectively. We determined the sensitivity and specificity of the three parameters for predicting low postnatal BMI and found values of 85.70% and 65.60%, respectively, for fetal weight, 90.48% and 88.17%, respectively, for fetal thigh volume, and 76.19% and 92.47%, respectively, for fetal upper arm volume. CONCLUSION: Fetal upper arm and thigh volumes estimated using 3DUS with XI VOCAL were effective predictors of low postnatal BMI.


Subject(s)
Body Mass Index , Imaging, Three-Dimensional , Infant, Low Birth Weight , Ultrasonography, Prenatal/methods , Adult , Algorithms , Arm/diagnostic imaging , Cross-Sectional Studies , Female , Humans , Infant, Newborn , Male , Pregnancy , Prospective Studies , ROC Curve , Thigh/diagnostic imaging , Young Adult
17.
J Obstet Gynaecol Res ; 39(9): 1374-82, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23822541

ABSTRACT

AIM: The aim of this study was to evaluate the passage of fetal erythrocytes into the maternal circulation after invasive obstetric procedures, using the Kleihauer-Betke test, flow cytometry and α-fetoprotein concentration in maternal blood. MATERIAL AND METHODS: This was a prospective descriptive study on patients who underwent: amniocentesis, cordocentesis, chorionic villus sample, amniotic infusion, bladder drainage and ventricular-amniotic shunt to investigate the karyotype; treatment for hydrocephalus, oligohydramnios, obstructive uropathy and polyhydramnios; and investigation of lung maturity. Maternal blood samples were collected before and 60 min after the invasive obstetric procedure in order to evaluate the passage of fetal erythrocytes using the Kleihauer-Betke test, flow cytometry and α-fetoprotein concentration. RESULTS: In total, 43 invasive obstetric procedures were performed. The procedures performed were: 27 cases of amniocentesis (62.7%), seven cases of cordocentesis (16.2%), four chorionic villus samples (9.4%), two amniotic infusions (4.7%), two ventricular-amniotic shunts and one bladder drainage (2.3%). After one case of cordocentesis with two puncture attempts via the placenta, a significant increase in fetal erythrocytes was detected using the three methods. After another cordocentesis with one puncture via the placenta, a significant increase in fetal erythrocytes was detected using flow cytometry and α-fetoprotein concentration, but not through the Kleihauer-Betke test. The other 41 samples did not show any significant increase in fetal erythrocytes in the maternal blood. CONCLUSION: Invasive obstetric procedures performed during prenatal care are safe when performed by experienced professionals with the proper technique, with minimal chance of passage of fetal erythrocytes into the maternal compartment.


Subject(s)
Amniocentesis/adverse effects , Chorionic Villi Sampling/adverse effects , Cordocentesis/adverse effects , Fetal Diseases/diagnosis , Fetomaternal Transfusion/etiology , Maternal-Fetal Exchange , Pregnancy Complications/diagnosis , Adolescent , Adult , Erythrocytes , Female , Fetal Diseases/blood , Fetomaternal Transfusion/blood , Humans , Pregnancy , Pregnancy Complications/blood , Prospective Studies , Young Adult
18.
Case Rep Pediatr ; 2012: 969860, 2012.
Article in English | MEDLINE | ID: mdl-23091766

ABSTRACT

Cloacal malformation is an extremely rare fetal pathological condition that presents as a variety of defects. It predominantly affects females, with prevalence of 1 in 50,000 births. Prenatal ultrasonography on a 20-year-old caucasian woman (G4P1A2) at 33 weeks of pregnancy showed the fetus having a large cystic mass in the lower abdomen with a single septum, bilateral hydronephrosis, ambiguous genitalia, and a single umbilical artery. The pregnancy developed accentuated oligohydramnios, and presence of a fetal brain-sparing effect was diagnosed using arterial Doppler velocimetry. The newborn showed abdominal distension, ambiguous genitalia, and rectal atresia, with a single perineal opening. Pelvic ultrasound done on the first day after delivery revealed the presence of a large retrovesical septated cystic mass of dense content in the fetal abdomen, and bilateral hydronephrosis. Hysterotomy was performed, and 70 mL of dense liquid was drained through an abdominal colostomy. The infant died on the 27th day of life as a result of infectious complications. Prenatal diagnosing of female urogenital anomalies is usually difficult because of their rarity, different types of manifestation, and lack of characteristic ultrasound signs. Presence of a septated cyst with dense content in the fetal abdomen confirms the finding of hydrometrocolpos, thus raising clinical suspicion of a cloacal anomaly.

19.
J Clin Imaging Sci ; 2: 30, 2012.
Article in English | MEDLINE | ID: mdl-22754744

ABSTRACT

Schizencephaly is a brain-destructive lesion relating to clefts in the fetal brain that usually communicate with the ventricular system, subarachnoid space, or both. It presents as two types: Type I (closed) and Type II (open). During pregnancy, it may be suspected in the course of ultrasonography, which highlights ventricular dilatation and brain abnormalities. Usually, the diagnosis is confirmed postnatally using trans-fontanel ultrasonography. The etiology of schizencephaly is still unknown, but it may be derived from a primary disorder of brain development or from bilateral middle cerebral artery occlusion. Many causative agents including vascular insult, infections, toxins, and medications have been associated with this malformation. We present a pictorial essay of six cases of schizencephaly that were suspected on prenatal ultrasound scans and confirmed postnatally by trans-fontanel, two-dimensional and three-dimensional ultrasonography.

20.
J Clin Imaging Sci ; 2: 22, 2012.
Article in English | MEDLINE | ID: mdl-22616039

ABSTRACT

Amniotic band syndrome is characterized by a build-up of bands and strings of fibrous tissue that adhere to the fetus and can compress parts of the fetus, thus causing malformations and even limb amputation while the fetus is still in the uterus. The clinical manifestations are extremely variable and their extent may range from a single abnormality, like a constriction ring, to multiple abnormalities. Such abnormalities are generally diagnosed at the end of the first or the beginning of the second trimester using two-dimensional ultrasonography (2DUS). Three-dimensional ultrasonography (3DUS) in rendering mode allows spatial analysis of the fetus and amniotic band, thus enabling better comprehension of this pathological condition and better counseling for the parents. There has not previously been any evidence to show that 3DUS would be useful in cases of late diagnosis (third trimester) of amniotic band syndrome. In the present case, a primigravid woman underwent her second obstetric ultrasound scan in the 34(th) week, from which we observed two bands in contact with the right forearm, but with normal movement of this limb and its fingers. 3DUS made it possible to see the spatial relationship of these bands to the fetal body, thereby confirming their adherence to the limb. After the birth, the prenatal diagnosis of amniotic band syndrome without limb constriction was confirmed. A surgical procedure was carried out on the third day after birth to excise the bands, and the newborn was then discharged in a good general condition.

SELECTION OF CITATIONS
SEARCH DETAIL
...