Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
STAR Protoc ; 5(3): 103299, 2024 Sep 07.
Article in English | MEDLINE | ID: mdl-39244756

ABSTRACT

Mesoscale to nanoscale three-dimensional (3D) fabrication mostly requires complicated industry processing techniques. Here, we present a protocol for 3D shaping control by solidifying a water-based TiO2 nanofluid drop on a polygonal wettability-patterned surface. We detail the steps for preparing stable TiO2 nanofluid and wettability-patterned surfaces. We then describe the experimental procedure to obtain various and precise 3D morphologies by adjusting the deposited TiO2 nanofluid drop volume. This protocol provides a promising technique for future 3D manufacturing. For complete details on the use and execution of this protocol, please refer to Jiang et al.1.

2.
Anal Chim Acta ; 1288: 342170, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38220301

ABSTRACT

The dye-doped silica nanoparticles-based electrogenerated chemiluminescence (ECL) has been widely explored for analytical purposes due to its high sensitivity, simplicity and wide dynamic concentration range. However, only a few of dye molecules located at the near surface of nanoparticles can participate in the ECL reaction due to the poor conductivity of silica nano-matrix. In addition, the ECL signal is easy to be affected by environmental interference, which results in poor accuracy. Herein, a ratiometric ECL sensing method is established based on the electrochemically controlled release of lucigenin molecules from silica/chitosan/lucigenin composite nanoparticles (Lu/CS NPs) with the aid of sulfide ions. Firstly, H+ produced from the electrochemical oxidation of HS- ions can combine with SiO- and displace lucigenin from Lu/CS NPs. The released lucigenin molecules react with the reactive oxygen species (ROS) generated from the electroreduction of dissolved oxygen to produce the cathodic ECL signal. In addition, the excited elemental sulfur from the electrooxidation of HS- ions transfers its energy to lucigenin molecules and makes them be excited to produce energy-transfer anodic ECL signal. Based on these findings, a ratiometric ECL sensor is developed taking the anodic ECL intensity of lucigenin as a reference signal for the cathodic ECL of lucigenin. The proposed ratiometric ECL sensor has been successfully applied to the detection of let-7a with a wide linear range of 0.1-9.0 pM, a low detection limit of 28 fM, high selectivity and good reproducibility. Moreover, the developed approach was used to detect let-7a in human serum composite samples with good recoveries.


Subject(s)
Acridines , Chitosan , MicroRNAs , Nanoparticles , Humans , Silicon Dioxide/chemistry , Chitosan/chemistry , Luminescence , Delayed-Action Preparations , Reproducibility of Results , Nanoparticles/chemistry , Ions , Luminescent Measurements/methods
SELECTION OF CITATIONS
SEARCH DETAIL