Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 258
Filter
1.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584394

ABSTRACT

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
2.
Eur Heart J ; 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38594778

ABSTRACT

BACKGROUND AND AIMS: Contemporary multicentre data on clinical and diagnostic spectrum and outcome in myocarditis are limited. Study aims were to describe baseline features, 1-year follow-up, and baseline predictors of outcome in clinically suspected or biopsy-proven myocarditis (2013 European Society of Cardiology criteria) in adult and paediatric patients from the EURObservational Research Programme Cardiomyopathy and Myocarditis Long-Term Registry. METHODS: Five hundred eighty-one (68.0% male) patients, 493 adults, median age 38 (27-52) years, and 88 children, aged 8 (3-13) years, were divided into 3 groups: Group 1 (n = 233), clinically suspected myocarditis with abnormal cardiac magnetic resonance; Group 2 (n = 222), biopsy-proven myocarditis; and Group 3 (n = 126) clinically suspected myocarditis with normal or inconclusive or no cardiac magnetic resonance. Baseline features were analysed overall, in adults vs. children, and among groups. One-year outcome events included death/heart transplantation, ventricular assist device (VAD) or implantable cardioverter defibrillator (ICD) implantation, and hospitalization for cardiac causes. RESULTS: Endomyocardial biopsy, mainly right ventricular, had a similarly low complication rate in children and adults (4.7% vs. 4.9%, P = NS), with no procedure-related death. A classical myocarditis pattern on cardiac magnetic resonance was found in 31.3% of children and in 57.9% of adults with biopsy-proven myocarditis (P < .001). At 1-year follow-up, 11/410 patients (2.7%) died, 7 (1.7%) received a heart transplant, 3 underwent VAD (0.7%), and 16 (3.9%) underwent ICD implantation. Independent predictors at diagnosis of death or heart transplantation or hospitalization or VAD implantation or ICD implantation at 1-year follow-up were lower left ventricular ejection fraction and the need for immunosuppressants for new myocarditis diagnosis refractory to non-aetiology-driven therapy. CONCLUSIONS: Endomyocardial biopsy was safe, and cardiac magnetic resonance using Lake Louise criteria was less sensitive, particularly in children. Virus-negative lymphocytic myocarditis was predominant both in children and adults, and use of immunosuppressive treatments was low. Lower left ventricular ejection fraction and the need for immunosuppressants at diagnosis were independent predictors of unfavourable outcome events at 1 year.

3.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-38195003

ABSTRACT

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/epidemiology , Arrhythmogenic Right Ventricular Dysplasia/therapy , Retrospective Studies , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Risk Factors , North America/epidemiology , Europe/epidemiology
4.
Eur J Prev Cardiol ; 31(4): 486-495, 2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38198223

ABSTRACT

AIMS: Right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs) have been associated with the presence of non-ischaemic left ventricular scar (NLVS) in athletes. The aim of this cross-sectional study was to identify clinical and electrocardiogram (ECG) predictors of the presence of NLVS in athletes with RBBB VAs. METHODS AND RESULTS: Sixty-four athletes [median age 39 (24-53) years, 79% males] with non-sustained RBBB VAs underwent cardiac magnetic resonance (CMR) with late gadolinium enhancement in order to exclude the presence of a concealed structural heart disease. Thirty-six athletes (56%) showed NLVS at CMR and were assigned to the NLVS positive group, whereas 28 athletes (44%) to the NLVS negative group. Family history of cardiomyopathy and seven different ECG variables were statistically more prevalent in the NLVS positive group. At univariate analysis, seven ECG variables (low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I-aVL, negative T waves in precordial leads V4-V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads) proved to be statistically associated with the finding of NLVS; these were grouped together in a score. A score ≥2 was proved to be the optimal cut-off point, identifying NLVS athletes in 92% of cases and showing the best accuracy (86% sensitivity and 100% specificity, respectively). However, a cut-off ≥1 correctly identified all patients with NLVS (absence of false negatives). CONCLUSION: In athletes with RBBB morphology non-sustained VAs, specific ECG abnormalities at 12-lead ECG can help in detecting subjects with NLVS at CMR.


In athletes with right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs), the presence of a non-ischaemic left ventricular scar (NLVS) may be highly suspected if one or more of the following electrocardiogram (ECG) characteristics are present at the 12-lead resting ECG: low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I­aVL, negative T waves in precordial leads V4­V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads. This score should be externally validated in a larger population of athletes with VAs. In athletes with RBBB morphology non-sustained Vas, attention should be placed on the 12-lead resting ECG to suspect the presence of an NLVS. In athletes with RBBB VAs and the presence of one or more of the identified ECG characteristics, a cardiac magnetic resonance with late gadolinium enhancement is useful to rule out an NLVS.


Subject(s)
Bundle-Branch Block , Ventricular Premature Complexes , Male , Humans , Adult , Female , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/etiology , Cicatrix/pathology , Contrast Media , Cross-Sectional Studies , Gadolinium , Electrocardiography
5.
medRxiv ; 2023 Dec 06.
Article in English | MEDLINE | ID: mdl-38106113

ABSTRACT

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

6.
Circulation ; 148(20): 1543-1555, 2023 11 14.
Article in English | MEDLINE | ID: mdl-37830188

ABSTRACT

BACKGROUND: Brugada syndrome poses significant challenges in terms of risk stratification and management, particularly for asymptomatic patients who comprise the majority of individuals exhibiting Brugada ECG pattern (BrECG). The aim of this study was to evaluate the long-term prognosis of a large cohort of asymptomatic patients with BrECG. METHODS: Asymptomatic patients with BrECG (1149) were consecutively collected from 2 Italian centers and followed-up at least annually for 2 to 22 years. For the 539 asymptomatic patients (men, 433 [80%]; mean age, 46±13 years) with spontaneous type 1 documented on baseline ECG (87%) or 12-lead 24-hour Holter monitoring (13%), an electrophysiologic study (EPS) was proposed; for the 610 patients with drug-induced-only type 1 (men, 420 [69%]; mean age, 44±14 years), multiple ECGs and 12-lead Holter were advised in order to detect the occurrence of a spontaneous type-1 BrECG. Arrhythmic events were defined as sudden death or documented ventricular fibrillation or tachycardia. RESULTS: Median follow-up was 6 (4-9) years. Seventeen (1.5%) arrhythmic events occurred in the overall asymptomatic population (corresponding to an event-rate of 0.2% per year), including 16 of 539 (0.4% per year) in patients with spontaneous type-1 BrECG and 1 of 610 in those with drug-induced type-1 BrECG (0.03% per year; P<0.001). EPS was performed in 339 (63%) patients with spontaneous type-1 BrECG. Patients with spontaneous type-1 BrECG and positive EPS had significantly higher event rates than patients with negative EPS (7 of 103 [0.7% per year] versus 4 of 236 [0.2% per year]; P=0.025). Among 200 patients who declined EPS, 5 events (0.4% per year) occurred. There was 1 device-related death. CONCLUSIONS: The entire population of asymptomatic patients with BrECG exhibits a relatively low event rate per year, which is important in view of the long life expectancy of these young patients. The presence of spontaneous type-1 BrECG associated with positive EPS identifies a subgroup at higher risk. Asymptomatic patients with drug-induced-only BrECG have a minimal arrhythmic risk, but ongoing follow-up with 12-lead Holter monitoring is recommended to detect the appearance of spontaneous type-1 BrECG pattern.


Subject(s)
Brugada Syndrome , Male , Humans , Adult , Middle Aged , Prospective Studies , Prognosis , Arrhythmias, Cardiac/complications , Electrocardiography , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Risk Assessment
7.
Diagnostics (Basel) ; 13(18)2023 Sep 05.
Article in English | MEDLINE | ID: mdl-37761231

ABSTRACT

A 50-year-old Caucasian man arrived at the emergency department presenting paucisymptomatic atrial fibrillation. Once discharged after the appropriate treatments, the patient continued to have paucisymptomatic episodes. For this reason, he was provided with the Cardionica device which made it possible to better investigate the type of arrhythmic episodes, in order to tailor his therapy and to finally restore a normal sinus rhythm in the patient.

8.
JACC Clin Electrophysiol ; 9(12): 2615-2627, 2023 12.
Article in English | MEDLINE | ID: mdl-37768253

ABSTRACT

BACKGROUND: Electrocardiographic (ECG) findings in arrhythmogenic left ventricular cardiomyopathy (ALVC) are limited to small case series. OBJECTIVES: This study aimed to analyze the ECG characteristics of ALVC patients and to correlate ECG with cardiac magnetic resonance and genotype data. METHODS: We reviewed data of 54 consecutive ALVC patients (32 men, age 39 ± 15 years) and compared them with 84 healthy controls with normal cardiac magnetic resonance. RESULTS: T-wave inversion was often noted (57.4%), particularly in the inferior and lateral leads. Low QRS voltages in limb leads were observed in 22.2% of patients. The following novel ECG findings were identified: left posterior fascicular block (LPFB) (20.4%), pathological Q waves (33.3%), and a prominent R-wave in V1 with a R/S ratio ≥0.5 (24.1%). The QRS voltages were lower in ALVC compared with controls, particularly in lead I and II. At receiver-operating characteristic analysis, the sum of the R-wave in I to II ≤8 mm (AUC: 0.909; P < 0.0001) and S-wave in V1 plus R-wave in V6 ≤12 mm (AUC: 0.784; P < 0.0001) effectively discriminated ALVC patients from controls. It is noteworthy that 4 of the 8 patients with an apparently normal ECG were recognized by these new signs. Transmural late gadolinium enhancement was associated to LPFB, a R/S ratio ≥0.5 in V1, and inferolateral T-wave inversion, and a ringlike pattern correlated to fragmented QRS, SV1+RV6 ≤12 mm, low QRS voltage, and desmoplakin alterations. CONCLUSIONS: Pathological Q waves, LPFB, and a prominent R-wave in V1 were common ECG signs in ALVC. An R-wave sum in I to II ≤8 mm and SV1+RV6 ≤12 mm were specific findings for ALVC phenotypes compared with controls.


Subject(s)
Cardiomyopathies , Contrast Media , Male , Humans , Young Adult , Adult , Middle Aged , Gadolinium , Electrocardiography , Arrhythmias, Cardiac , Bundle-Branch Block
9.
Europace ; 25(10)2023 10 05.
Article in English | MEDLINE | ID: mdl-37776313

ABSTRACT

AIMS: To assess the impact of MultiPoint™ Pacing (MPP) in cardiac resynchronization therapy (CRT) non-responders after 6 months of standard biventricular pacing (BiVP). METHODS AND RESULTS: The trial enrolled 5850 patients who planned to receive a CRT device. The echocardiography core laboratory assessed CRT response before implant and after 6 months of BiVP; non-response to BiVP was defined as <15% relative reduction in left ventricular end-systolic volume (LVESV). Echocardiographic non-responders were randomized in a 1:1 ratio to receive MPP (541 patients) or continued BiVP (570 patients) for an additional 6 months and evaluated the conversion rate to the echocardiographic response. The characteristics of both groups at randomization were comparable. The percentage of non-responder patients who became responders to CRT therapy was 29.4% in the MPP arm and 30.4% in the BIVP arm (P = 0.743). In patients with ≥30 mm spacing between the two left ventricular pacing sites (MPP-AS), identified during the first phase as a potential beneficial subgroup, no significant difference in the conversion rate was observed. CONCLUSION: Our trial shows that ∼30% of patients, who do not respond to CRT in the first 6 months, experience significant reverse remodelling in the following 6 months. This finding suggests that CRT benefit may be delayed or slowly incremental in a relevant proportion of patients and that the percentage of CRT responders may be higher than what has been described in short-/middle-term studies. MultiPoint™ Pacing does not improve CRT response in non-responders to BiVP, even with MPP-AS.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Treatment Outcome , Prospective Studies , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Cardiac Resynchronization Therapy Devices , Ventricular Function, Left/physiology
10.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37656991

ABSTRACT

AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1 h/day and periods with an AHRE burden ≥20 h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1 h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1 h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20 h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1 h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20 h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Heart Failure , Humans , Algorithms , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Heart Atria , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/therapy
11.
Front Cardiovasc Med ; 10: 1115328, 2023.
Article in English | MEDLINE | ID: mdl-37529713

ABSTRACT

Aims: Supraventricular tachycardias may trigger atrial fibrillation (AF). The aim of the study was to evaluate the prevalence of supraventricular tachycardia (SVT) inducibility in patients referred for AF ablation and to evaluate the effects of SVT ablation on AF recurrences. Methods and results: 249 patients (mean age: 54 ± 14 years) referred for paroxysmal AF ablation were studied. In all patients, only AF relapses had been documented in the clinical history. 47 patients (19%; mean age: 42 ± 11 years) had inducible SVT during the electrophysiological study and underwent an ablation targeted only at SVT suppression. Ablation was successful in all 47 patients. The ablative procedures were: 11 slow-pathway ablations for atrioventricular nodal re-entrant tachycardia; 6 concealed accessory pathway ablations for atrioventricular re-entrant tachycardia; 17 focal ectopic atrial tachycardia ablations; 13 with only one arrhythmogenic pulmonary vein. No recurrences of SVT were observed during the follow-up (32 ± 18 months). 4 patients (8.5%) showed recurrence of at least one episode of AF. Patients with inducible SVT had less structural heart disease and were younger than those without inducible SVT. Conclusion: A significant proportion of candidates for AF ablation are inducible for an SVT. SVT ablation showed a preventive effect on AF recurrences. Those patients should be selected for simpler ablation procedures tailored only to the triggering arrhythmia suppression.

12.
Pacing Clin Electrophysiol ; 46(9): 1049-1055, 2023 09.
Article in English | MEDLINE | ID: mdl-37527153

ABSTRACT

BACKGROUND: Intermittent ventricular pre-excitation was considered a low-risk marker for sudden death. However, to date, some studies do not exclude the existence of accessory pathways (APs) with high-risk intermittent antegrade conductive properties. According to current European Guidelines, high-risk features of APs are antegrade pathway conduction ≤250 ms in baseline or during the adrenergic stimulus, inducibility of atrioventricular reciprocating tachycardias (AVRT), inducibility of pre-excited atrial fibrillation (AF), and presence of multiple APs. For all of these transcatheter ablation is recommended. The aim of our study was to evaluate the existence of differences in risk characteristics between patients with intermittent pre-excitation (IPX) and those with persistent pre-excitation (PPX), from a sample of adults with ventricular pre-excitation and symptoms like palpitations. METHODS: 293 adults [IPX: 51 (17.4%); PPX: 242 (82.6%)] underwent electrophysiological study and then catheter ablation of their APs if arrhythmia inducibility (AVRT/AF) was noted, or, conversely, if it was appreciated a fast AP antegrade conduction, in baseline or during intravenous isoproterenol infusion, or if multiple APs were detected. RESULTS: There were no statistically significant differences in demographic characteristics (age and gender), AVRT/AF inducibility, antegrade conductive properties, the prevalence of multiple APs, and APs locations between IPX and PPX patients. CONCLUSIONS: In our study, patients with IPX did not show significant differences in clinical and electrophysiological features versus PPX patients.


Subject(s)
Accessory Atrioventricular Bundle , Atrial Fibrillation , Catheter Ablation , Pre-Excitation Syndromes , Wolff-Parkinson-White Syndrome , Humans , Adult , Accessory Atrioventricular Bundle/surgery , Atrial Fibrillation/surgery , Risk Factors , Electrocardiography
13.
Front Cardiovasc Med ; 10: 1178163, 2023.
Article in English | MEDLINE | ID: mdl-37404739

ABSTRACT

Cardiomyopathies are a heterogeneous group of pathologies characterized by structural and functional alterations of the heart. Recent technological advances in cardiovascular imaging offer an opportunity for deep phenotypic and etiological definition. Electrocardiogram (ECG) is the first-line diagnostic tool in the evaluation of both asymptomatic and symptomatic individuals. Some electrocardiographic signs are pathognomonic or fall within validated diagnostic criteria of individual cardiomyopathy such as the inverted T waves in right precordial leads (V1-V3) or beyond in individuals with complete pubertal development in the absence of complete right bundle branch block for the diagnosis of arrhythmogenic cardiomyopathy of the right ventricle (ARVC) or the presence of low voltages typically seen in more than 60% of patients with amyloidosis. Most other electrocardiographic findings such as the presence of depolarization changes including QRS fragmentation, the presence of epsilon wave, the presence of reduced or increased voltages as well as alterations in the repolarization phase including the negative T waves in the lateral leads, or the profound inversion of the T waves or downsloping of the ST tract are more non-specific signs which can however raise the clinical suspicion of cardiomyopathy in order to initiate a diagnostic procedure especially using imaging techniques for diagnostic confirmation. Such electrocardiographic alterations not only have a counterpart in imaging investigations such as evidence of late gadolinium enhancement on magnetic resonance imaging, but may also have an important prognostic value once a definite diagnosis has been made. In addition, the presence of electrical stimulus conduction disturbances or advanced atrioventricular blocks that can be seen especially in conditions such as cardiac amyloidosis or sarcoidosis, or the presence of left bundle branch block or posterior fascicular block in dilated or arrhythmogenic left ventricular cardiomyopathies are recognized as a possible expression of advanced pathology. Similarly, the presence of ventricular arrhythmias with typical patterns such as non-sustained or sustained ventricular tachycardia of LBBB morphology in ARVC or non-sustained or sustained ventricular tachycardia with an RBBB morphology (excluding the "fascicular pattern") in arrhythmogenic left ventricle cardiomyopathy could have a significant impact on the course of each disease. It is therefore clear that a learned and careful interpretation of ECG features can raise suspicion of the presence of a cardiomyopathy, identify diagnostic "red flags" useful for orienting the diagnosis toward specific forms, and provide useful tools for risk stratification. The purpose of this review is to emphasize the important role of the ECG in the diagnostic workup, describing the main ECG findings of different cardiomyopathies.

15.
Europace ; 25(7)2023 07 04.
Article in English | MEDLINE | ID: mdl-37466354

ABSTRACT

AIMS: Left ventricular scar is an arrhythmic substrate that may be missed by echocardiography and diagnosed only by cardiac magnetic resonance (CMR), which is a time-consuming and expensive imaging modality. Premature ventricular complexes (PVCs) with a right-bundle-branch-block (RBBB) pattern are independent predictors of late gadolinium enhancement (LGE) but their positive predictive value is low. We studied which electrocardiographic features of PVCs with an RBBB pattern are associated with a higher probability of the absence of an underlying LGE. METHODS: The study included 121 athletes (36 ± 16 years; 48.8% men) with monomorphic PVCs with an RBBB configuration and normal standard clinical investigations who underwent CMR. LGE was identified in 35 patients (29%), predominantly in those with PVCs with a superior/intermediate axis (SA-IntA) compared to inferior axis (IA) (38% vs. 10%, P = 0.002). Among patients with SA-IntA morphology, the contemporary presence of qR pattern in lead aVR and V1 was exclusively found in patients without LGE at CMR (51.0% vs. 0%, P < 0.0001). Among patients with IA, the absence of LGE correlated to a narrow ectopic QRS (145 ± 16 vs. 184 ± 27 msec, P < 0.001). CONCLUSIONS: Among athletes with apparently idiopathic PVCs with a RBBB configuration, the presence of a concealed LGE at CMR was documented in 29% of cases, mostly in those with a SA-IntA. In our experience, the contemporary presence of qR pattern in lead aVR and V1 in PVCs with RBBB/SA-IntA morphology or, on the other hand, a relatively narrow QRS in PVCs with an IA, predicted absence of LGE.


Subject(s)
Cicatrix , Ventricular Premature Complexes , Male , Humans , Female , Contrast Media , Gadolinium , Heart Ventricles/diagnostic imaging , Electrocardiography/methods , Bundle-Branch Block , Athletes
16.
J Cardiovasc Med (Hagerstown) ; 24(7): 453-460, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37285276

ABSTRACT

BACKGROUND: The noninferiority of left ventricular pacing alone (LVp) compared with biventricular pacing (BIV) has not been yet definitely documented. In this study, we reviewed all the original echocardiographic measures of the Biventricular versus Left Univentricular Pacing with ICD Back-up in Heart Failure Patients (B-LEFT HF) trial in order to investigate mechanisms underlying LV remodelling with both pacing modalities. METHODS: Patients with New York Heart Association functional class (NYHA) III or IV despite optimal medical therapy, LVEF 35% or less, left ventricular end-diastolic diameter (LVEDD) more than 55 mm, QRS duration at least 130 ms were randomized to BIV or LVp for 6 months. The primary end point was a composite of at least 1 point decrease in NYHA class and at least 5 mm decrease in left ventricular end-systolic diameter (LVESD). An additional end point was a LVp reverse remodelling defined as at least 10% decrease in LVESD. Mitral regurgitation and all echocardiographic measures were reassessed after 6-month follow-up. RESULTS: One hundred and forty-three patients were enrolled. Seventy-six patients were in the BIV and 67 were in the LVp group. Left ventricular volumes decreased significantly without difference between groups (P = 0.8447). Similarly, left ventricular diameters decreased significantly in both groups with a significant decrease in LVESD with BIV (P < 0.0001), but not with LVp (P = 0.1383). LVEF improved in both groups without difference (P = 0.8072). Mitral regurgitation did not improve either with BIV, or with LVp. CONCLUSION: The echocardiographic sub-analysis of B-LEFT study showed the substantial equivalence of LVp in favouring left ventricular reverse remodelling as compared with BIV.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Mitral Valve Insufficiency , Humans , Cardiac Pacing, Artificial , Mitral Valve Insufficiency/therapy , Stroke Volume , Echocardiography , Heart Failure/diagnostic imaging , Heart Failure/therapy , Cardiac Resynchronization Therapy/adverse effects , Treatment Outcome , Randomized Controlled Trials as Topic
17.
ESC Heart Fail ; 10(4): 2469-2478, 2023 08.
Article in English | MEDLINE | ID: mdl-37278122

ABSTRACT

AIMS: The HeartLogic algorithm combines multiple implantable defibrillator (ICD) sensor data and has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation in cardiac resynchronization therapy (CRT-D) patients. We evaluated the performance of this algorithm in non-CRT ICD patients and in the presence of co-morbidities. METHODS AND RESULTS: The HeartLogic feature was activated in 568 ICD patients (410 with CRT-D) from 26 centres. The median follow-up was 26 months [25th-75th percentile: 16-37]. During follow-up, 97 hospitalizations were reported (53 cardiovascular) and 55 patients died. We recorded 1200 HeartLogic alerts in 370 patients. Overall, the time IN the alert state was 13% of the total observation period. The rate of cardiovascular hospitalizations or death was 0.48/patient-year (95% CI: 0.37-0.60) with the HeartLogic IN the alert state and 0.04/patient-year (95% CI: 0.03-0.05) OUT of the alert state, with an incidence rate ratio of 13.35 (95% CI: 8.83-20.51, P < 0.001). Among patient characteristics, atrial fibrillation (AF) on implantation (HR: 1.62, 95% CI: 1.27-2.07, P < 0.001) and chronic kidney disease (CKD) (HR: 1.53, 95% CI: 1.21-1.93, P < 0.001) independently predicted alerts. HeartLogic alerts were not associated with CRT-D versus ICD implantation (HR: 1.03, 95% CI: 0.82-1.30, P = 0.775). Comparisons of the clinical event rates in the IN alert state with those in the OUT of alert state yielded incidence rate ratios ranging from 9.72 to 14.54 (all P < 0.001) in all groups of patients stratified by: CRT-D/ICD, AF/non-AF, and CKD/non-CKD. After multivariate correction, the occurrence of alerts was associated with cardiovascular hospitalization or death (HR: 1.92, 95% CI: 1.05-3.51, P = 0.036). CONCLUSIONS: The burden of HeartLogic alerts was similar between CRT-D and ICD patients, while patients with AF and CKD seemed more exposed to alerts. Nonetheless, the ability of the HeartLogic algorithm to identify periods of significantly increased risk of clinical events was confirmed, regardless of the type of device and the presence of AF or CKD.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Heart Failure/epidemiology , Heart Failure/therapy , Atrial Fibrillation/etiology , Algorithms , Morbidity
18.
J Cardiovasc Dev Dis ; 10(6)2023 Jun 11.
Article in English | MEDLINE | ID: mdl-37367420

ABSTRACT

Atrial fibrillation (AF) is the most common cause of hospital admission among all arrhythmias in the general population. Moreover, AF represents the most common arrhythmia in the athletic population as well. The complex but fascinating relationship between sport and atrial fibrillation has not yet been fully clarified. Although the benefits of moderate physical activity in controlling cardiovascular risk factors and in reducing the risk of atrial fibrillation have been widely demonstrated, some concerns have been raised about the potential adverse effects of physical activity. Endurance activity in middle-aged men athletes appears to increase the risk of AF. Several different physiopathological mechanisms may explain the increased risk of AF in endurance athletes, including the imbalance of the autonomic nervous system, changes in left atrial size and function and presence of atrial fibrosis. The goal of this article is to review the epidemiology, pathophysiology and clinical management for AF in athletes, including pharmacological and electrophysiological strategies.

19.
J Arrhythm ; 39(3): 310-314, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37324770

ABSTRACT

Advances in cardiac implantable electronic devices (CIEDs) have prolonged life expectancy in various medical settings. However, the issue of hypersensitivity to components of CIEDs is still a concern. Since 1970, allergic reactions to metallic and nonmetallic components of CIEDs have been reported. Hypersensitivity reactions to medical devices are rare and not fully understood. In some cases, diagnosis and treatment are difficult. Cardiologists should always keep in mind pacemaker allergy when a patient appears with wound complications and no signs of infection. Patch testing should be tailored toward the specific biomaterials used in a device, in addition to testing with standard screening allergens in select cases.

20.
J Cardiovasc Electrophysiol ; 34(6): 1386-1394, 2023 06.
Article in English | MEDLINE | ID: mdl-37194742

ABSTRACT

INTRODUCTION: Brugada syndrome (BrS) has a dynamic ECG pattern that might be revealed by certain conditions such as fever. We evaluated the incidence and management of ventricular arrhythmias (VAs) related to COVID-19 infection and vaccination among BrS patients carriers of an implantable loop recorder (ILR) or implantable cardioverter-defibrillator (ICD) and followed by remote monitoring. METHODS: This was a multicenter retrospective study. Patients were carriers of devices with remote monitoring follow-up. We recorded VAs 6 months before COVID-19 infection or vaccination, during infection, at each vaccination, and up to 6-month post-COVID-19 or 1 month after the last vaccination. In ICD carriers, we documented any device intervention. RESULTS: We included 326 patients, 202 with an ICD and 124 with an ILR. One hundred and nine patients (33.4%) had COVID-19, 55% of whom developed fever. Hospitalization rate due to COVID-19 infection was 2.76%. After infection, we recorded only two ventricular tachycardias (VTs). After the first, second, and third vaccines, the incidence of non-sustained ventricular tachycardia (NSVT) was 1.5%, 2%, and 1%, respectively. The incidence of VT was 1% after the second dose. Six-month post-COVID-19 healing or 1 month after the last vaccine, we documented NSVT in 3.4%, VT in 0.5%, and ventricular fibrillation in 0.5% of patients. Overall, one patient received anti-tachycardia pacing and one a shock. ILR carriers had no VAs. No differences were found in VT before and after infection and before and after each vaccination. CONCLUSIONS: From this large multicenter study conducted in BrS patients, followed by remote monitoring, the overall incidence of sustained VAs after COVID-19 infection and vaccination is relatively low.


Subject(s)
Brugada Syndrome , COVID-19 , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/epidemiology , Brugada Syndrome/therapy , Retrospective Studies , Incidence , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/prevention & control , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/therapy , Registries , Vaccination , Follow-Up Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...