Results 1 - 20 de 36
Filter
1.
Anal Bioanal Chem ; 416(9): 2335-2358, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38236394

ABSTRACT

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health, Office of Dietary Supplements (NIH ODS), introduced the first Standard Reference Material® (SRM) for determining vitamin D metabolites in 2009 motivated by significant concerns about the comparability and accuracy of different assays to assess vitamin D status. After 14 years, a suite of five serum matrix SRMs and three calibration solution SRMs are available. Values were also assigned for vitamin D metabolites in five additional SRMs intended primarily to support measurements of other clinical diagnostic markers. Both the SRMs and the certification approach have evolved from significant exogenous serum content to primarily endogenous content and from value assignment by combining the results of multiple analytical methods to the use of measurements exclusively from reference measurement procedures (RMPs). The impact of the availability of these SRMs can be assessed by both the distribution information (sales) and by reports in the scientific literature describing their use for method validation, quality control, and research. In this review, we describe the development of these SRMs, the evolution in design and value assignment, the expansion of information reported, and SRM use in validating analytical methods and providing quality assurance within the vitamin D measurement community.


Subject(s)
Vitamin D , Vitamins , Quality Control , Reference Standards , Dietary Supplements/analysis
2.
Clin Chem ; 69(11): 1227-1237, 2023 11 02.
Article in English | MEDLINE | ID: mdl-37725906

ABSTRACT

It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.


Subject(s)
Clinical Laboratory Services , Laboratory Proficiency Testing , Humans , Reference Standards , Reagent Kits, Diagnostic
3.
Clin Chem ; 69(9): 966-975, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37566391

ABSTRACT

A secondary higher-order calibrator is required to be commutable with clinical samples to be suitable for use in the calibration hierarchy of an end-user clinical laboratory in vitro diagnostic medical device (IVD-MD). Commutability is a property of a reference material that means results for a reference material and for clinical samples have the same numeric relationship, within specified limits, across the measurement procedures for which the reference material is intended to be used. Procedures for assessing commutability have been described in the literature. This report provides recommendations for establishing a quantitative criterion to assess the commutability of a certified reference material (CRM). The criterion is the maximum allowable noncommutability bias (MANCB) that allows a CRM to be used as a calibrator in a calibration hierarchy for an IVD-MD without exceeding the maximum allowable combined standard uncertainty for a clinical sample result (umaxCS). Consequently, the MANCB is derived as a fraction of the umaxCS for the measurand. The suitability of an MANCB for practical use in a commutability assessment is determined by estimating the number of measurements of clinical samples and CRMs required based on the precision performance and nonselectivity for the measurand of the measurement procedures in the assessment. Guidance is also provided for evaluating indeterminate commutability conclusions and how to report results of a commutability assessment.

4.
J Steroid Biochem Mol Biol ; 231: 106318, 2023 07.
Article in English | MEDLINE | ID: mdl-37169270

ABSTRACT

Ninety archived human serum samples from the Vitamin D External Quality Assessment Scheme (DEQAS) were analyzed using a reference measurement procedure (RMP) based on isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS) for the determination of 24,25-dihydroxyvitamin D3 [24,25(OH)2D3]. These 24,25(OH)2D3 results, in conjunction with concentration values assigned using RMPs for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3], provide a valuable resource for assessing the accuracy of measurements for 24,25(OH)2D3 and for investigating the relationship between 24,25(OH)2D3 and 25(OH)D3. Results for 24,25(OH)2D3 using the RMP were compared to DEQAS consensus values demonstrating that the consensus values were not sufficient to assess the accuracy of measurements among different laboratories and methods. A multivariable regression analysis approach using historical DEQAS consensus values for various total 25(OH)D assays was used to assess the contribution of 24,25(OH)2D3 concentration on the assay response. The response of several ligand binding assays for total 25(OH)D was shown to be impacted by the presence of 24,25(OH)2D3.


Subject(s)
Tandem Mass Spectrometry , Vitamin D , Humans , Chromatography, Liquid , Tandem Mass Spectrometry/methods , Vitamins , Calcifediol , 24,25-Dihydroxyvitamin D 3
5.
Anal Bioanal Chem ; 415(5): 809-821, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36507958

ABSTRACT

The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.


Subject(s)
Folic Acid , Tandem Mass Spectrometry , Humans , Folic Acid/analysis , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Reference Standards , Ascorbic Acid
6.
Anal Bioanal Chem ; 414(1): 333-349, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34432104

ABSTRACT

An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays used for the determination of serum total 25-hydroxyvitamin D (25(OH)D), which is the sum of 25-hydroxyvitamin D2 (25(OH)D2) and 25-hydroxyvitamin D3 (25(OH)D3). A set of 50 single-donor samples was assigned target values for concentrations of 25(OH)D2, 25(OH)D3, 3-epi-25-hydroxyvitamin D3 (3-epi-25(OH)D3), and 24R,25-dihydroxyvitamin D3 (24R,25(OH)2D3) using isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 1 includes results from 14 laboratories using 14 custom LC-MS/MS assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 53% of the LC-MS/MS assays met the VDSP criterion of mean % bias ≤ |±5%|. For the LC-MS/MS assays not meeting the ≤ |±5%| criterion, four assays had mean % bias of between 12 and 21%. Based on multivariable regression analysis using the concentrations of the four individual vitamin D metabolites in the 50 single-donor samples, the performance of several LC-MS/MS assays was found to be influenced by the presence of 3-epi-25(OH)D3. The results of this interlaboratory study represent the most comprehensive comparison of LC-MS/MS assay performance for serum total 25(OH)D and document the significant impact of the lack of separation of 3-epi-25(OH)D3 and 25(OH)D3 on assay performance, particularly with regard to mean % bias.


Subject(s)
Tandem Mass Spectrometry , Vitamin D , 25-Hydroxyvitamin D 2 , Chromatography, Liquid/methods , Reference Standards , Tandem Mass Spectrometry/methods , Vitamin D/analogs & derivatives
7.
Anal Bioanal Chem ; 414(1): 351-366, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34435207

ABSTRACT

An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25-hydroxyvitamin D3 [3-epi-25(OH)D3], and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 50% of the ligand binding assays achieved the VDSP criterion of mean % bias ≤ |± 5%|. For the 13 unique ligand binding assays evaluated in this study, only 4 assays were consistently within ± 5% mean bias and 4 assays were consistently outside ± 5% mean bias regardless of the laboratory performing the assay. Based on multivariable regression analysis using the concentrations of individual vitamin D metabolites in the 50 single-donor samples, most assays underestimate 25(OH)D2 and several assays (Abbott, bioMérieux, DiaSorin, IDS-EIA, and IDS-iSYS) may have cross-reactivity from 24R,25(OH)2D3. The results of this interlaboratory study represent the most comprehensive comparison of 25(OH)D ligand binding assays published to date and is the only study to assess the impact of 24R,25(OH)2D3 content using results from a reference measurement procedure.


Subject(s)
Tandem Mass Spectrometry , Vitamin D , 25-Hydroxyvitamin D 2 , Chromatography, Liquid , Ligands , Reference Standards , Vitamin D/analogs & derivatives
8.
Anal Bioanal Chem ; 414(2): 1015-1028, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34750644

ABSTRACT

The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at -40 °C prior to distribution and the participants are instructed to store the samples frozen at -20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC-MS/MS assays, the differences in the results for the ambient- and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays.


Subject(s)
Freezing , Vitamin D/analogs & derivatives , Vitamin D/blood , Chromatography, Liquid/methods , Humans , Tandem Mass Spectrometry/methods
9.
Clin Chem ; 67(12): 1590-1605, 2021 11 26.
Article in English | MEDLINE | ID: mdl-34633037

ABSTRACT

BACKGROUND: The JCTLM created a Task Force on Reference Measurement System Implementation (TF-RMSI) to provide guidance on metrological traceability implementation for the in vitro diagnostics (IVD) community. CONTENT: TF-RMSI investigated the reference measurement systems (RMS) for 13 common measurands by applying the following procedural steps: (a) extracting data from the JCTLM database of available certified reference materials (CRMs) and reference measurement procedures (RMPs); (b) describing the RMS to which each recruited CRM or RMP belongs; (c) identifying the intended use of the CRMs, and, if used as a common calibrator for IVD measuring systems and/or trueness assessment of field methods was included, checking the CRM's certificate for information about commutability with clinical samples; and (d) checking if the CRM or RMP measurement uncertainty (MU) has the potential to be small enough to avoid significantly affecting the analytical performance specifications (APS) for MU of clinical sample results when the MU from the IVD calibrator and from the end-user measuring system were combined. SUMMARY: We produced a synopsis of JCTLM-listed higher-order CRMs and RMPs for the selected measurands, including their main characteristics for implementing traceability and fulfilling (or not) the APS for suitable MU. Results showed that traceability to higher-order references can be established by IVD manufacturers within the defined APS for most of the 13 selected measurands. However, some measurands do not yet have suitable CRMs for use as common calibrators. For these measurands, splitting clinical samples with a laboratory performing the RMP may provide a practical alternative for establishing a calibration hierarchy.


Subject(s)
Laboratories , Calibration , Databases, Factual , Humans , Reference Standards , Uncertainty
10.
Anal Bioanal Chem ; 413(20): 5067-5084, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34184102

ABSTRACT

An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.


Subject(s)
Societies, Medical/standards , Vitamin D/analogs & derivatives , Vitamin D/chemistry , Humans , Reference Standards , Specimen Handling , Vitamin D/blood
11.
J Steroid Biochem Mol Biol ; 212: 105917, 2021 09.
Article in English | MEDLINE | ID: mdl-34010687

ABSTRACT

An intralaboratory study assessing assay variability and bias for determination of serum total 25-hydroxyvitamin D [25(OH)D] was conducted by the Vitamin D Standardization Program (VDSP). Thirteen assays for serum total 25(OH)D were evaluated in a single laboratory including 11 unique immunoassays and one liquid chromatography - tandem mass spectrometry (LC-MS/MS) assay. Fifty single-donor serum samples, including eight samples with high concentrations of 25(OH)D2 (> 30 nmol/L), were assigned target values for 25(OH)D2 and 25(OH)D3 using reference measurement procedures (RMP). Using four replicate measurements for each sample, the mean total percent coefficient of variation (%CV) and mean % bias from the target values were determined for each assay using the 50 single-donor samples and a 42-sample subset, which excluded 8 high 25(OH)D2 concentration samples, and compared with VDSP performance criteria of ≤ 10 % CV and ≤ ±5 % mean bias. All 12 assays achieved the performance criterion for % CV, and 9 of the 12 assays were within ≤ ±5 % mean bias. The Fujirebio Inc. assay exhibited the lowest %CV and highest percentage of individual measurements within ≤ ±5 % mean bias. Ten immunoassays exhibited changes in response due to the high 25(OH)D2 samples with Abbott, Biomérieux, DiaSorin, DIAsource, and IDS-iSYS assays having the largest deviations. The Fujirebio Inc. and Beckman Coulter assays were only minimally affected by the presence of the high 25(OH)D2 samples. Samples with high concentrations of 25(OH)D2 provided a critical performance test for immunoassays indicating that some assays may not have equal response or recovery for 25(OH)D2 and 25(OH)D3.


Subject(s)
Biological Assay/standards , Immunoassay/standards , Vitamin D/analogs & derivatives , Vitamins/blood , Bias , Chromatography, Liquid , Humans , Laboratories , Reference Standards , Reproducibility of Results , Tandem Mass Spectrometry , Vitamin D/blood
12.
Clin Chem ; 66(6): 769-778, 2020 06 01.
Article in English | MEDLINE | ID: mdl-32335671

ABSTRACT

Establishing metrological traceability to an assigned value of a matrix-based certified reference material (CRM) that has been validated to be commutable among available end-user measurement procedures (MPs) is central to producing equivalent results for the measurand in clinical samples (CSs) irrespective of the clinical laboratory MPs used. When a CRM is not commutable with CSs, the bias due to noncommutability will be propagated to the CS results causing incorrect metrological traceability to the CRM and nonequivalent CS results among different MPs. In a commutability assessment, a conclusion that a CRM is commutable or noncommutable for use with a specific MP is made when the difference in bias between the CRM and CSs meets or does not meet a criterion for that specific MP when compared to other MPs. A conclusion regarding commutability or noncommutability requires that the magnitude of the difference in bias observed in the commutability assessment remains unchanged over time. This conclusion requires the CRM to be stable and no substantive changes in the MPs. These conditions should be periodically reverified. If an available CRM is determined to be noncommutable for a specific MP, that CRM can be used in the calibration hierarchy for that MP when an appropriately validated MP-specific correction for the noncommutability bias is included. We describe with examples how a MP-specific correction and its uncertainty can be developed and applied in a calibration hierarchy to achieve metrological traceability of results for CSs to the CRM's assigned value.


Subject(s)
Bias , Guidelines as Topic , Reagent Kits, Diagnostic/standards , Calibration , Humans , Reference Standards
13.
Clin Chem Lab Med ; 58(3): 368-374, 2020 02 25.
Article in English | MEDLINE | ID: mdl-31665109

ABSTRACT

Manufacturers of in vitro diagnostic medical devices, clinical laboratories, research laboratories and calibration laboratories require commutable reference materials that can be used in the calibration hierarchies of medical laboratory measurement procedures used for human specimens to establish metrological traceability to higher order reference systems. Commutable materials are also useful in external quality assessment surveys. In order to achieve these goals, matrix-based reference materials with long-term stability, appropriate measurand concentrations and commutability with individual human specimens are required. The Clinical and Laboratory Standards Institute (CLSI) guideline C37-A (now archived) provided guidance to prepare commutable pooled serum reference materials for use in the calibration hierarchies of cholesterol measurement procedures. Experience using the C37-A guideline has identified a number of technical enhancements as well as applications to measurands other than cholesterol. This experience is incorporated into this updated protocol to ensure the procedure will continue to meet the needs of the medical laboratory. The updated protocol describes a procedure for preparing frozen human serum units or pools with minimal matrix alterations that are likely to be commutable with individual human serum samples. The protocol provides step-by-step guidance for the planning phase, collection of individual serum units, processing the units, qualifying the units for use in a pool and frozen storage of aliquots of pooled sera to manufacture frozen serum pools. Guidance on how to perform quality control of the final product and suggestions on documentation are also provided.


Subject(s)
Blood Chemical Analysis/standards , Blood Specimen Collection/methods , Documentation , Serum/chemistry , Humans , Reference Values
14.
Anal Bioanal Chem ; 411(28): 7341-7355, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31667564

ABSTRACT

Over two decades, the Organic Analysis Working Group (OAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) has organized a number of comparisons for clinically relevant small molecule organic biomarkers. The aim of the OAWG community is to be part of the coordinated international movement towards accuracy and comparability of clinical measurements that will, in turn, minimize the wastage of repeat testing and unnecessary therapy to create a sustainable healthcare industry. International and regional directives/requirements on metrological traceability of calibrators and control materials are in place. Metrology institutes worldwide maintain infrastructure for the practical realization of metrological traceability and demonstrate the equivalence of their measurement capabilities through participation in key comparisons organized under the auspices of the CCQM. These institutes provide certified reference materials, as well as other dedicated value-assignment services benefiting the in-vitro diagnostic (IVD) industry, reference (calibration) laboratories and the clinical chemistry laboratories. The roles of these services in supporting national, regional, and international activities to ensure the metrological traceability of clinical chemistry measurements are described. Graphical abstract.


Subject(s)
Biomarkers/analysis , Organic Chemicals/analysis , Small Molecule Libraries/analysis , Calibration , Clinical Chemistry Tests , Humans , In Vitro Techniques , Reference Standards , Reproducibility of Results
15.
Anal Bioanal Chem ; 410(9): 2321-2329, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29435636

ABSTRACT

Dietary fatty acids can be both beneficial and detrimental to human health depending on the degree and type of saturation. Healthcare providers and research scientists monitor the fatty acid content of human plasma and serum as an indicator of health status and diet. In addition, both the Centers for Disease Control & Prevention (CDC) and the National Institutes of Health - Office of Dietary Supplements are interested in circulating fatty acids (FAs) because they may be predictive of coronary heart disease. The National Institute of Standards and Technology (NIST) provides a wide variety of reference materials (RMs) and Standard Reference Materials® (SRM®s) including blood, serum, plasma, and urine with values assigned for analytes of clinical interest. NIST SRM 2378 Fatty Acids in Frozen Human Serum was introduced in 2015 to help validate methods used for the analysis of FAs in serum, and consists of three different pools of serum acquired from (1) healthy donors who had taken fish oil dietary supplements (at least 1000 mg per day) for at least one month (level 1 material), (2) healthy donors who had taken flaxseed oil dietary supplements (at least 1000 mg per day) for at least one month (level 2 material), and (3) healthy donors eating "normal" diets who had not taken dietary supplements containing fish or plant oils (level 3 material). The use of dietary supplements by donors provided SRMs with natural endogenous ranges of FAs at concentrations observed in human populations. Results from analyses using two methods at NIST, including one involving a novel microwave-assisted acid hydrolysis procedure, and one at the CDC are presented here. These results and their respective uncertainties were combined to yield certified values with expanded uncertainties for 12 FAs and reference values with expanded uncertainties for an additional 18 FAs.


Subject(s)
Chromatography, Gas/methods , Dietary Supplements , Fatty Acids/blood , Flame Ionization/methods , Gas Chromatography-Mass Spectrometry/methods , Blood Preservation , Chromatography, Gas/standards , Cryopreservation , Dietary Supplements/analysis , Fatty Acids/standards , Fatty Acids, Unsaturated/blood , Fatty Acids, Unsaturated/standards , Fish Oils/administration & dosage , Fish Oils/blood , Flame Ionization/standards , Freezing , Gas Chromatography-Mass Spectrometry/standards , Humans , Plant Oils/administration & dosage , Plant Oils/analysis , Reference Standards
16.
Clin Chem ; 64(3): 447-454, 2018 03.
Article in English | MEDLINE | ID: mdl-29348163

ABSTRACT

Commutability is a property of a reference material (RM) that relates to the closeness of agreement between results for an RM and results for clinical samples (CSs) when measured by ≥2 measurement procedures (MPs). Commutability of RMs used in a calibration traceability scheme is an essential property for them to be fit for purpose. Similarly, commutability of trueness controls or external quality assessment samples is essential when those materials are used to assess trueness of results for CSs. This report is part 1 of a 3-part series describing how to assess commutability of RMs. Part 1 defines commutability and addresses critical components of the experimental design for commutability assessment, including selection of individual CSs, use of pooled CSs, qualification of MPs for inclusion, establishing criteria for the determination that an RM is commutable, generalization of commutability conclusions to future measurements made with the MPs included in the assessment, and information regarding commutability to be included in the certificate for an RM. Parts 2 and 3 in the series present 2 different statistical approaches to commutability assessment that use fixed criteria related to the medical decisions that will be made using the laboratory test results.


Subject(s)
Clinical Laboratory Techniques/standards , Calibration , Humans , Reference Standards
17.
Clin Chem ; 64(3): 465-474, 2018 03.
Article in English | MEDLINE | ID: mdl-29348164

ABSTRACT

A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator based on its ability to fulfill its intended use in a calibration traceability scheme to produce equivalent clinical sample (CS) results among different measurement procedures (MPs) for the same measurand. Three sources of systematic error are elucidated in the context of creating the calibration model for translating MP signals to measurand amounts: calibration fit, calibrator level trueness, and commutability. An example set of 40 CS results from 7 MPs is used to illustrate estimation of bias and variability for each MP. The candidate RM is then used to recalibrate each MP, and its effectiveness in reducing the systematic error among the MPs within an acceptable level of equivalence based on medical requirements confirms its commutability for those MPs. The RM is declared noncommutable for MPs for which, after recalibration, the CS results do not agree with those from other MPs. When a lack of agreement is found, other potential causes, including lack of calibration fit, should be investigated before concluding the RM is noncommutable. The RM is considered fit for purpose for those MPs where commutability is demonstrated.


Subject(s)
Clinical Laboratory Techniques/standards , Reference Standards , Bias , Calibration , Humans
18.
Clin Chem ; 64(3): 455-464, 2018 03.
Article in English | MEDLINE | ID: mdl-29348165

ABSTRACT

A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator, trueness control, or external quality assessment sample based on the difference in bias between an RM and clinical samples (CSs) measured using 2 different measurement procedures (MPs). This difference in bias is compared with a criterion based on a medically relevant difference between an RM and CS results to make a conclusion regarding commutability. When more than 2 MPs are included, the commutability is assessed pairwise for all combinations of 2 MPs. This approach allows the same criterion to be used for all combinations of MPs included in the assessment. The assessment is based on an error model that allows estimation of various random and systematic sources of error, including those from sample-specific effects of interfering substances. An advantage of this approach is that the difference in bias between an RM and the average bias of CSs at the concentration (i.e., amount of substance present or quantity value) of the RM is determined and its uncertainty estimated. An RM is considered fit for purpose for those MPs for which commutability is demonstrated.


Subject(s)
Clinical Laboratory Techniques/standards , Bias , Clinical Laboratory Techniques/statistics & numerical data , Data Interpretation, Statistical , Humans , Reference Standards , Specimen Handling/standards , Uncertainty
19.
J AOAC Int ; 100(5): 1260-1276, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-28863788

ABSTRACT

Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.


Subject(s)
25-Hydroxyvitamin D 2/blood , Blood Chemical Analysis/standards , Humans , National Institutes of Health (U.S.) , Quality Control , United States , Vitamin D
20.
J AOAC Int ; 100(5): 1230-1233, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-28766476

ABSTRACT

The Vitamin D Standardization Program (VDSP) has collaborated with numerous groups and agencies to assemble a set of tools, i.e., a reference measurement system, that can be used to establish the traceability of 25-hydroxyvitamin D [25(OH)D] assays to relevant reference measurement procedures and reference materials. This is done with the goal of verifying end-user laboratory performance using precise statistical criteria to determine whether a specific assay is standardized. The purpose of this paper was to outline a set of steps that routine clinical and research laboratories can use to standardize their 25(OH)D assays using these tools. These steps apply to laboratories using commercially developed immunoassay measurement systems as well as in-house assays, usually based on high HPLC or LC tandem MS measurement systems. The steps are (1) initial calibration, (2) initial assessment of accuracy and bias, (3) assessment of total percent CV and mean bias, (4) use of trueness controls, and (5) participation in accuracy-based performance testing and/or external quality assessment schemes. The goal of each laboratory assay is to have a total CV of ≤10% and mean bias of ≤5%. Rigorous and less rigorous but low-cost options for meeting these statistical criteria are provided. Research laboratories who infrequently measure 25(OH)D are advised to repeat steps 1-4 for every measurement cycle. For users of commercial immunoassays who have relatively little control over standardization, we present an option for using trueness controls to develop a master equation that can be used to standardize results to the reference methods.


Subject(s)
Blood Chemical Analysis/standards , Vitamin D/analogs & derivatives , Chromatography, High Pressure Liquid/standards , Chromatography, Liquid/standards , Humans , Immunoassay/standards , Reference Standards , Tandem Mass Spectrometry/standards , Vitamin D/blood