Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Heart Rhythm ; 2024 May 27.
Article in English | MEDLINE | ID: mdl-38810922

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) and very high-power short-duration (vHPSD) radiofrequency ablation are the most recently introduced technologies for atrial fibrillation (AF) ablation. The procedural performance, safety, and effectiveness of PFA vs vHPSD are currently unknown. OBJECTIVE: The study aimed to compare PFA with vHPSD for the treatment of paroxysmal or persistent AF. METHODS: We conducted an observational, multicenter study enrolling 534 consecutive patients (63 ± 9 years; 36% female) with paroxysmal (n = 368 [69%]) or persistent (n = 166 [31%]) AF undergoing ablation by either PFA (Farawave; n = 192) or vHPSD (90 W/4 seconds; QDOT Micro; n = 342) between 2020 and 2023. Atrial tachyarrhythmia recurrence after a 1-month blanking period was the primary efficacy end point and was assessed both overall and in propensity score-matched patients. The primary safety end point was a composite of procedure-related complications. RESULTS: Successful pulmonary vein isolation was achieved in all patients, with shorter procedure duration (PFA,70 minutes; vHPSD, 100 minutes; P < .001) but longer fluoroscopy time (PFA, 15 minutes; vHPSD, 7 minutes; P < .001) in the PFA group. PFA was associated with more frequent use of general anesthesia (P < .001). Primary safety outcome events occurred in 19 patients (3.5%), with similar prevalence in both groups (PFA, 4%; vHPSD, 3%; P = .745). After a median follow-up of 12 (9-12) months, survival free from recurrent atrial tachyarrhythmia was similar between the PFA and vHPSD groups, both overall (12-month estimate: PFA, 75%; vHPSD, 76%; log-rank P = .73) and in propensity score-matched patients (n = 342; 12-month estimate: PFA, 75%; vHPSD, 77%; log-rank P = .980). CONCLUSION: In a large, multicenter experience, PFA was associated with more common use of general anesthesia, shorter procedural times, and longer fluoroscopy exposure compared with vHPSD ablation, with both techniques displaying superimposable safety and efficacy.

2.
J Clin Med ; 13(7)2024 Mar 24.
Article in English | MEDLINE | ID: mdl-38610635

ABSTRACT

There are no investigations about the outcomes of idiopathic PVC catheter ablation (CA) in athletes compared to the sedentary population. We conducted a prospective single-centre observational study. The primary and secondary procedural outcomes were the post-ablation reduction of premature ventricular contractions (PVCs) in an athletes vs. non-athletes group and in agonist vs. leisure-time athletes. The third was the evaluation of the resumption of physical activity and the improvement of symptoms in agonist and leisure-time athletes. From January 2020 to October 2022 we enrolled 79 patients with RVOT/LVOT/fascicular PVC presumed origin. The median percentage of decrease between the pre-procedure and post-procedure Holter monitoring in the non-athletes group was 96 (IQR 68-98) and 98 in the athletes group (IQR 92-99) (p = 0.08). Considering the athletes, the median percentage of decrease in the number of PVCs was 98 (IQR 93-99) and 98 (IQR 87-99), respectively, in leisure-time and agonistic athletes (p = 0.42). Sixteen (70%) leisure time and seventeen (90%) agonist athletes (p = 0.24) have resumed physical activity 3 months after PVC CA; among agonistic athletes, 59% have resumed competitive physical activity. Many leisure-time (88%) and agonist (70%) athletes experienced an improvement in symptoms after ablation. PVC CA was effective and safe in both groups, reducing symptoms and allowing a quick and safe return to sports activities in athletes.

3.
J Interv Card Electrophysiol ; 67(3): 549-557, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37584862

ABSTRACT

BACKGROUND: The clinical performance of high-power, short-duration (HPSD) pulmonary vein isolation (PVI) with the novel flexible tip TactiFlex™ (TFSE) catheter, as compared to standard-power, long-duration (SPLD) PVI using the TactiCath™ (TCSE) catheter among patients undergoing catheter ablation (CA) of atrial fibrillation (AF) is currently unknown. METHODS: We conducted a prospective, observational, single-centre study including 40 consecutive patients undergoing PVI for paroxysmal/persistent AF, using HPSD ablation with the novel TFSE catheter (HPSD/TFSE group). Based on propensity score-matching, forty patients undergoing SPLD PVI with the TCSE catheter were identified (SPLD/TCSE group). In the HPSD/TFSE group, RF lesions were performed by delivering 40-50 W for 10-20 s, while in the SPLD/TCSE group, RF power was 30-35 W, targeting a lesion size index (LSI) of 4.0-5.5. The co-primary study outcomes were time required to complete PVI and first pass isolation (FPI). RESULTS: PVI was achieved in 100% of patients in both groups, and no major adverse events were observed. Remarkably, PVI time was shorter in the HPSD/TFSE, compared to the SPLD/TCSE group(9 [7-9] min vs. 50 [37-54] min; p < 0.001), while FPI rate was non-significantly higher in the former group(91% [146/160] vs 83% [134/160]; p = 0.063). Shorter procedural (108 [91-120] min vs. 173 [139-187] min, p < 0.001), total RF (9 [7-11] min vs. 43 [32-53] min, p < 0.001), fluoroscopy times(15 [10-19] min vs. 18 [13-26] min, p = 0.014), and lower DAP (1461 [860-2181] vs. 7200 [3400-20,800], p < 0.001) were recorded in the HPSD/TFSE group. A higher average impedance drop was obtained with HPSD/TFSE CA(17[17-18]Ω vs. 16 [15-17] Ω, p < 0.001). CONCLUSIONS: In our initial clinical experience, HPSD PVI with the TFSE catheter proved faster than SPLD PVI with the TCSE catheter, at least equally effective in terms of FPI, and it was associated with greater impedance drop.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Catheter Ablation/adverse effects , Catheters , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
4.
Article in English | MEDLINE | ID: mdl-38087147

ABSTRACT

BACKGROUND: Several novel technologies allowing catheter ablation (CA) with a favorable safety/efficacy profile have been recently developed, but not yet extensively clinically tested in the setting of ventricular tachycardia CA. METHODS: In this technical report, we overview technical aspects and preclinical/clinical information concerning the application of three novel CA technologies in the ventricular milieu: a pulsed field ablation (PFA) generator (CENTAURI™, Galaxy Medical) to be used with linear, contact force-sensing radiofrequency ablation catheters; a contact force-sensing radiofrequency ablation catheter equipped with six thermocouples and three microelectrodes (QDOT Micro™, Biosense-Webster), allowing high-resolution mapping and temperature-controlled CA; and a flexible and mesh-shaped irrigation tip, contact force-sensing radiofrequency ablation catheter (Tactiflex, Abbott). We also report three challenging VT cases in which CA was performed using these technologies. RESULTS: The CENTAURI system was used with the Tacticath™ (Abbott) ablation catheter to perform ventricular PFA in a patient with advanced heart failure, electrical storm, and a deep intramural septal substrate. Microelectrode mapping using QDOT Micro™ helped to refine substrate assessment in a VT patient with congenitally corrected transposition of the great arteries, and allowed the identification of the critical components of the VT circuit, which were successfully ablated. Tactiflex™ was used in two challenging CA cases (one endocardial and one epicardial), allowing acute and mid-term control of VT episodes without adverse events. CONCLUSION: The ideation and development of novel technologies initially intended to treat atrial arrhythmias and successfully implemented in the ventricular milieu is contributing to the progressive improvement in the clinical benefits derived from VT CA, making this procedure key for successful management of increasingly complex patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...