Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Sensors (Basel) ; 24(7)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38610371

ABSTRACT

Dielectric characterization is extremely promising in medical contexts because it offers insights into the electromagnetic properties of biological tissues for the diagnosis of tumor diseases. This study introduces a promising approach to improve accuracy in the dielectric characterization of millimeter-sized biopsies based on the use of a customized electromagnetic characterization system by adopting a coated open-ended coaxial probe. Our approach aims to accelerate biopsy analysis without sample manipulation. Through comprehensive numerical simulations and experiments, we evaluated the effectiveness of a metal-coating system in comparison to a dielectric coating with the aim for replicating a real scenario: the use of a needle biopsy core with the tissue inside. The numerical analyses highlighted a substantial improvement in the reconstruction of the dielectric properties, particularly in managing the electric field distribution and mitigating fringing field effects. Experimental validation using bovine liver samples revealed highly accurate measurements, particularly in the real part of the permittivity, showing errors lower than 1% compared to the existing literature data. These results represent a significant advancement for the dielectric characterization of biopsy specimens in a rapid, precise, and non-invasive manner. This study underscores the robustness and reliability of our innovative approach, demonstrating the convergence of numerical analyses and empirical validation.


Subject(s)
Electricity , Animals , Cattle , Reproducibility of Results , Biopsy
2.
Diagnostics (Basel) ; 13(18)2023 Sep 21.
Article in English | MEDLINE | ID: mdl-37761382

ABSTRACT

Dielectric characterization has significant potential in several medical applications, providing valuable insights into the electromagnetic properties of biological tissues for disease diagnosis, treatment planning, and monitoring of therapeutic interventions. This work presents the use of a custom-designed electromagnetic characterization system, based on an open-ended coaxial probe, for discriminating between benign and malignant breast tissues in a clinical setting. The probe's development involved a well-balanced compromise between physical feasibility and its combined use with a reconstruction algorithm known as the virtual transmission line model (VTLM). Immediately following the biopsy procedure, the dielectric properties of the breast tissues were reconstructed, enabling tissue discrimination based on a rule-of-thumb using the obtained dielectric parameters. A comparative analysis was then performed by analyzing the outcomes of the dielectric investigation with respect to conventional histological results. The experimental procedure took place at Complejo Hospitalario Universitario de Toledo-Hospital Virgen de la Salud, Spain, where excised breast tissues were collected and subsequently analyzed using the dielectric characterization system. A comprehensive statistical evaluation of the probe's performance was carried out, obtaining a sensitivity, specificity, and accuracy of 81.6%, 61.5%, and 73.4%, respectively, compared to conventional histological assessment, considered as the gold standard in this investigation.

SELECTION OF CITATIONS
SEARCH DETAIL
...