1.
J Ophthalmol ; 2015: 131970, 2015.
Article in English | MEDLINE | ID: mdl-26495134

ABSTRACT

Purpose. To evaluate the safety and efficacy of adding brinzolamide 1%/timolol maleate 0.5% fixed combination (BTFC) to a prostaglandin analog (PGA). Methods. This was a 12-week, open-label, single-arm study of patients with open-angle glaucoma or ocular hypertension with intraocular pressure (IOP) not sufficiently controlled after ≥4 weeks of PGA monotherapy. The primary outcome was mean IOP change from baseline at week 12. Other outcomes included IOP change from baseline at week 4, percentage of patients achieving IOP ≤18 mmHg at week 12, and patient experience survey responses at week 12. Results. Forty-seven patients were enrolled and received treatment. The most commonly used PGAs were latanoprost (47%) and travoprost (32%). Mean ± SD IOP was decreased at week 12 (17.2 ± 4.1 mmHg) compared with baseline (23.1 ± 3.0 mmHg; P < 0.001, paired t-test); IOP at week 4 was 17.2 ± 3.3 mmHg. At week 12, 70% of patients achieved IOP ≤18 mmHg. Patient-reported symptoms (e.g., pain and redness) were mostly unchanged from baseline. Twenty-eight adverse events (AEs) were reported; the most frequently reported AE was headache (3 events in 2 patients). Conclusion. Adjunctive BTFC + PGA therapy was effective and well tolerated. IOP decreased by 6 mmHg at weeks 4 and 12.

3.
Invest Ophthalmol Vis Sci ; 50(9): 4135-41, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19357360

ABSTRACT

PURPOSE: To assess the repeatability and reproducibility of central corneal thickness (CCT) measurements obtained by combined scanning-slit/Placido-disc topography (Orbscan II; Bausch & Lomb, Rochester, NY) after laser in situ keratomileusis (LASIK) and to compare the results with another noncontact method, specular microscopy (SP-2000P; Topcon, Tokyo, Japan). METHODS: To analyze intrasession repeatability, one examiner measured 22 postmyopic LASIK eyes 10 times successively in the shortest time possible, using both devices randomly. To study intersession reproducibility, the same operator obtained measurements from another 50 eyes with stable refraction in two consecutive visits at the same time of the day between 6 and 9 months after myopic LASIK. Any association between residual stromal bed thickness and measurement variability was recorded and evaluated. RESULTS: For intrasession repeatability, Orbscan II and Topcon SP-2000P CCT measurements showed a repeatability of 20.2 (4.3%) and 12.8 (2.6%) microm, respectively. Both devices yielded excellent intraclass correlation coefficients (ICC; 0.98 and 0.99, respectively). For intersession reproducibility, no difference in CCT measurements was found. The coefficient of intersession reproducibility were 6.7% (29.5 microm) for Orbscan II and 4.3% (19.5 microm) for Topcon SP-2000P CCT measurements. The ICCs (0.95 and 0.96, respectively) indicated good intersession reliability. Repeatability and reproducibility with both devices were unrelated to stromal bed thickness. CONCLUSIONS: Both noncontact pachymeters provide repeatable CCT measurements in transparent postmyopic LASIK corneas after the early postoperative period. Intersession variations in CCT of more than 29 microm with the Orbscan II and 19 microm with the Topcon SP-2000P may reflect true corneal change. These estimates should help investigators and clinicians differentiate actual CCT modification from measurement variability.


Subject(s)
Cornea/pathology , Diagnostic Techniques, Ophthalmological , Keratomileusis, Laser In Situ , Lasers, Excimer/therapeutic use , Adult , Body Weights and Measures , Cornea/surgery , Female , Follow-Up Studies , Humans , Male , Middle Aged , Myopia/surgery , Postoperative Period , Prospective Studies , Refraction, Ocular/physiology , Reproducibility of Results , Surgical Flaps , Tomography/methods , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL